Loading...
HomeMy WebLinkAboutProject Informationct Summary Job: -� wrightsoft® Entire House � Date: Jan 11, ao1� By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM Prooect Information For: TOM & SHARON ENGLISH 5339 MONTEGO CIRCLE LOT #361, FT. PIERCE, FL 34949 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15215 Btuh Structure 20941 Btuh Ducts 5102 Btuh Ducts 7707 Btuh Central vent (20 cfm) 628 Btuh Central vent (20 cfm) 336 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20945 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenfsensible load 0.95 27535 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1834 Btuh Ducts 2085 Btuh Central vent (20 cfm) 853 Btuh Heating Coolingg Outside air load 4772 Btuh Area (ft2 1478 1476 Equipment latent Volume ?ft.) 10206 10206 Air changes/hour 0.45 0.23 Equipment total load 32307 Btuh Equiv. AVF (cfm) 77 39 Req. total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make THERMAL ZONE Trade Trade Model Cond 4ZAH-36JO AHRI ref Coil AHRI ref Efficiency 100 EFF Efficiency 11.0 EER, 13 SEER Heating input 5.7 kW Sensible cooling 24500 Btuh Heating output 19544 Btuh Latent cooling. 10500 Btuh Temperature rise 15 OF Total cooling 35000 Btuh Actual air flow 1167 cfm Actual air flow 1167 cfm Air flow factor 0.057 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft' 2017-Jan-1114:19:49 .� 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ACCK ...Quick Calcs\Documents\ENGLISH, TOM & SHARON.rup Cale = MJ8 Front Doorfaces: N - - wrightsoft" Right-J® Worksheet Job: Entire House Date: Jan 11, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House EXISTING 2 Exposed wall 162.0 ft 117.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 896.0 ft 5 Room area 1134.0 ft2 896.0 ft2 Ty Construction U-value Or HTM Area (ft5 Load Area (ft5 Load number (Btuh/ft? °F) (Btuh/ft2) or pedmeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6%J�j128-0sw 0.097 ne 2.72 2.58 189 148 402 382 36 15 41 39 2 glazing, clr low-e 0.650 ne 18.20 15.14 20 0 364 303 0 0 0 0 11DO 0.390 ne 10.92 11.31 21 21 229 238 21 21 229 238 WI 12B-Osw 0.097 se Z72 2.58 540 507 1377 1308 414 387 1051 999 11 - EjIA-clom 1.270 se 35.56 70.95 27 0 960 1916 27 0 960 1916 �--G 2 glazing, clr low-e 0.650 se 18.20 10.53 6 5 109 63 0 0 0 0 126-0sw 0.097 sw 2.72 2.58 189 124 337 320 189 124 337 320 1A-clom 1.270 sw 35.56 70.95 24 0 853 1703 24 0 853 1703 IA-clomd 1.270 sw 35.56 70.95 41 0 1451 2895 41 0 1451 2895 W 12B-Osw 0.097 nw 2.72 2.58 540 492 1336 1269 414 366 994 944 L-G 1A-clom 1.270 nw 35.56 70.43 48 0 1707 3381 48 0 1707 3381 C 17A-17zd 0.048 - 1.34 1.66 1134 1134 1524 1878 896 896 1204 1484 F 19A-19bstp 0.049 - 1.08 0.58 896 696 963 516 896 896 963 516 F 22A4pl 0.989 - 27.69 0.00 238 45 1246 0 0 0 0 0 6 c) AED excursion 1895 1891 Envelope loss/gain 12860 18066 9791 16324 12 a) Infiltration 2355 645 1701 466 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 2000 2000 Subtotal (lines 6 to 13) 15215 20941 11493 19020 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 15215 20941 11493 19020 15 Duct loads 34% 37% 5102 7707 34% 37% 3853 7000 Total room load 20317 28647 15346 26020 Air required (cfm) 1167 1167 881 1060 to meet J 8th Ed. A -F- wrightsoft' 2017-Jan-11 14:e I Right-Suile® Universal 2017 17.0.14 RSU08101 Page ...Quick CalcslDocuments\ENGLISH, TOM & SHARON.rup Calc = MJ8 Front Door faces: N -OLrF wrightsoft' Ri ht-M Woritsheet Job: g Date: Jan 11, 2017 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name NEW BEDROOM NEW BATH 2 Exposed wall 36.0 ft 9.0ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 184.0 ft 9.0 x 6.0 ft 5 Room area 184.0 ft2 54.0 ftz Ty Construction U-value Or HTM Area M Load Area (ft� Load number (Btuh/f?Z °F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1213-0sw 0.097 ne 2.72 2.58 153 133 361 343 0 0 0 0 2 glazing, clr low-e 0.650 ne 18.20 15.14 20 0 364 303 0 0 0 0 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 12B-Osw 0.097 se 2.72 2.58 45 45 122 116 81 75 204 194 11 T IA -clam 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 10.53 0 0 0 0 6 5 109 63 V+J 12B-0sw 0.097 sw 2.72 2.58 0 0 0 0 0 0 0 0 -1A-c1om 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 I�-GG 1A-c1omd 1.270 sw 35.56 70.95 0 0 0 0 0 0 0 0 W 128-0sw 0.097 nw 2.72 2.58 126 126 342 325 0 0 0 0 L- G 1A-ciom 1.270 nw 35.56 70.43 0 0 0 0 0 0 0 0 C 17A-17zd 0.046 - 1.34 1.66 184 184 247 305 54 54 73 89 F 19A-19bstp 0.049 - 1.08 0.58 0 0 0 0 0 0 0 0 F 22A4pl 0.989 - 27.69 0.00 184 36 997 0 54 9 249 0 6 c) AED excursion -10 13 Envelope loss/gain 2434 1382 635 359 12 a) Infiltration 523 143 131 36 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 2957 1526 766 395 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2957 1526 766 395 15 Duct loads 34% 37% 992 562 34% 37% 257 145 Total room load 3949 L 2087 1 1022 540 Air required (cfm) I 227 85 1 59 22 L meet all -Fk wrightsoft- 2017-Jan-11 14:19:49 Right-Sufte® Universal 2017 17.0.14 RSU08101 Page 2 ...Quick Calcs%Documents\ENGLISH, TOM & SHARON.rup Calc = MJ8 Front Door faces: N