Loading...
HomeMy WebLinkAboutRevisionOFFICE USE ONLY: ' DATE FILED: I l REVISION FEE: PERMIT # RECEIPT if PLANNING & DHVI%@M NT`SERTI+CE BUILDING & CODE REGULATION DMSION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 FAX (772) 462-1578 APPLICATION FOR BUII,DING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE ,. _ //�� ADDRESS: .53-3 % 1,bo! EGG C_..1kcj.,c /-L 34 e/s L1 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: GCJj� 1,� l2c-i= CRf= 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #:Cff-0Sb ST. LUCIE COUNTY CERT. #: 7�®� BUSINESS NAME: R45 5O z A 9f-1IL1S T,(9rC QUALIFIERS NAME: ADDRESS: . ! CITY: _S 645' ►4A-Y STATE: �L ZIP: PHONE (DAYTIME): 2.1=2 12 35 -<-W*7n FAX: 4. OWNERBUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE: 5. ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): Revised 07/22/2014 STATE: FAX: STATE: ' FAX: ZIP: ZIP: ,,Y, .ppt ?y ;�` � „r.s� a. �� .�� ''��;� ' � •�� :;;ice Florida Building Code Online `villa Department« BCIS Home Log In I User Registration Hot Topics Submit Surcharge Slats & Facts Business/�'� Professi ' dalUSER: Approval Public User a Regulation Product Annroval Monu > ProA i t or Anoll a[lon S arch > Bppli ation I rst > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email FL17443 New 2014 Approved 3 A TAYLOR ROOFING 302 Melton Drive FT PIERCE, FL 34982 (772)466-4040 Flvalidation@yahoo.com jtie, Cody I � 1� Page 1 of 2 EVA, Publications FBC Staff BCIS Site Map Unks Search rica �i �.fvS AIND ALL PROPOSED WORK BARE 13UDJECT TO ANY CORRECTIONS . REQUIRED 1131Y FIELD INSPECTORS THAT :•. MA"I BE'NECESSPARY, IN ORDERTO: 6iCf�'� L�r. Irt :! LA?.PLICAL as CODES:'' Kyle Taylor 1 190 — —"A15 flvalidation@yahoo.com S d. LITC7E C'0IT'TTa' PUT—ITI°T0 DIVISION RF tJF�T'WED FOR � >`,L4XCE DATE 11 r'LY.�S A TD PE'TUAITFP�dIi�JST kE XEPT ON JOB Category cz:ii; Subcategoryg Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer F Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Locke Bowden Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/11/2021 Validated By Hermes F. Norero, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL17443 . RO COI Certificate of Indeoend Locke Bowden P.E..odf Referenced Standard and Year (of Standard) Standard ULS80 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Year 2006 CONCEALED FASTENERS OR ATTACHME0 ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD Method 1 Option D https://Horidabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtCUGgvjQiz6A%2brQi3pbzvra%2b%2fl bg7g2KOBRzEzIHXSCw%3d%3d July 28, 2015 Florida Building Code Online Page 2 of 2 t Date Submitted 03/02/2015 Date Validated 03/02/2015 Date Pending FBC Approval 03/05/2015 Date Approved 04/15/2015 Summary_ -of Products --------------- FL # Model, Number or Name Description i 17443.1 15 V Crimp 26GA 1/2" rib height over 15/32" plywood i ...,1-- - -- — _ ..— ---- --- -- -_---._. _ _.... _ —_ - ----- ------ - - i Limits of Use Installation Instructions Approved for use in HVHZ: No FL17443 RO II 5 V Crimp Fastening Detail.pdf Approved for use outside HVHZ: Yes Verified By: PRI Construction Materials Technologies, LLC Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-129.25 Evaluation Reports i Other:-129.25 @ 6" o.c. -69.25 @16" o.c. margin of safety FL17443 RO AE FL 17443 ] A Taylor Roofing 5 V Crimp 1; 2:1 with 24" max. coverage Install per manufacturers detail. Report-ss.pdf I Not for use in HVHZ. Created by Independent Third Party: Yes Cnnract ll<:; 1940 Nnrth Monroe Street_ Tallahaccpe FI 77199 Phnne• RSn-4R7-IR74 The State of Florida Is an AA/EEO employer. rnnvrlght M117- n11 State of Florida :: Privacv Statement :: Arree<Ihility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. Pursuant to Section 455.2750), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick bgm. Product Approval Accepts: ® et1 USEW CreditSCarFdE https://floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgtCUGgvjQiz6A%2brQi3pbzvra°/92b%2flbg7g2KOBRzEzIHXSCw%3d°/a3d July28,2015 File Comb CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Certificate of Authorization No, 29824 17520 Edinburgh Drive Tampa, FL 33647 (813)480-3421 2010 FLORIDA BUILDING CODE Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued May 7, 2014 1 Owens Corning Parkway Toledo, OH 43657 (800)438-7465 www. owenscorn i n.g. corn Manufacturing Location: Brentwood, NH Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.2.4. 1507.2.9.2, 1507.3.3, 1507.5.3 Properties: Physical properties REFERENCES E02M Report No. Standard Year PRI Construction Materials Technologies (TST6049) NEI-039-02-01 ASTM 0 1970 2001 PRI Construction Materials Technologles (TST6049) NEI-042-02-01 REV2 ASTM D 1970 2001 PRI Construction Materials Technologies (TST6049) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) NEI.045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST6049) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5049) NEI-093-02-02 ASTM D 1970 2001 PRI Construction Materials Technologies (TST6049) OCF-213-02-01 ASTM D 1623 2009 PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock® G WeatherLockO G is an ASTM D 1970 self-adhesive underayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® G is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLockV Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- sq. rolls with nominal dimensions of 3-ft x 33,3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft WeatherLock® Mat is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® WeatherLock® Specialty is an ASTM D 1970 self-adhesive underlayment constructed Specialty Tile 8 Metal from SBS modified asphalt and surfaced with a non -woven polyester fabric. The product is supplied in 2 sq. rolls with. nominal dimensions of 3-ft x 66.7-ft and 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. OCR14002 FL9777-R3 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 9N-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. e CREEK TECHNICAL SERVICES, LLC OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock(D Self -Sealing Ice & Water Barriers WeatherLock® WeatherLock® Specialty Tile & Metal is permitted to be used with mechanically fastened Specialty Tile & Metal asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or (continued) shingles, and slate roofing as prescribed in the FBC_ WeatherLock® Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either 3MTM 2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TILE BONDTm Roof Tile Adhesive (The Dow Chemical Company) up to a maximum design pressure of A5 psf and in accordance with the system approval. Exposure on the roof deck shall be limited to a maximum 90 days. PRODUCT APPLICATION Min. Roof Slope: Application: Min. Application Temperature: GENERAL LIMITATIONS The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12, Tiles shall not be stacked greater than 10 tiles per stack. 2:12 or in accordance in with FBC Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed direct -to -plywood decking with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6" staggered end laps. End laps for WeatherLock® Specialty Tile & Metal shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to nail the underlayment 18-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads Flush to the top surface of the underlayment). WeatherLock® Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. For valley applications, the roll shall be applied centered along the valley prior to installing the underlayment at the eave. For eave protection, the underlayment should extend to a point 24-inches inside the exterior wall. The underlayment shall be installed over metal drip edge at the eave, and under the drip edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible to install the underlayment under the drip edge in accordance Section 1507.2.9.3. 40"F; Contact the manufacturer when installing at temperatures below the minimum application temperature. 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluaton. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. OCR14001 FL9777-R3 2 of 3 This evaluation report is provided for State of Florida product approval under Rule SIG20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. , X _ . Ar CREEKOWENS Weathe CORNING ROOFING AND ASPHALT LLC WeatherLocke Self -Sealing Ice &Water Barriers TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein have demonstrated compliance with the 2010 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. �11%J1urlr1rri R, p G -" c EN No 74021 zo1420:1po5.a7 ��, STATE OF .:��►� ��i:.. /� -� .. O R t 0 P C?��` ,"�Ak- Zachary R. Priest, P.E. Florida Registration No. 21 , ��, Organ ationNo. ANE9641 CERTIFICATION OF -INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial Interest In any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14001 FL9777-R3 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. File Copy Locke Bowden, P.E. 9450 Alysbury Place Montgomery, AL 36117 FL # 17443 JA Taylor Roofing Inc 302 Melton Drive Fort Pierce, FL 34982 Product: 5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel, 24" net coverage, 26GA min. over min.] 5/32" thick CDX plywood decks. Compliance: Florida Building Code (FBC) 2014; Section 1504.3.2, Section 1507.2.8, Section 1507.4.3 UL580 "Tests for. Uplift Resistance" Description: Architectural metal roof panel, 26 gauge metal panels; over min. 15/32"CDX plywood and shall comply with Florida Building Code 2014, Section 1507.4.3 Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1507.4.2 -Deck-Slope 2:12 or greater and shall be compliant with Florida Building Code 2014, Section 1507.4.2. Design Pressure:-129.25 psf @ 6"o.c. and-69.25psf @16" o.c.; Fasten along the crown of the rib in the center of panel and along the.lap. Design pressure includes safety factor =2.0. First fastener to be within 3" of panel- edges. Min. 8d x 2" annular ring shank nails spaced 6" o.c. reroofing, with less than 19/32" plywood 9min. 15/32"), this attachment is to be used in addition to existing attachment. Deck attachment to be by other design professional. Underlayment: approved product in compliance with FBC 2014, Section 1507.2.8 Thru-fastened over, min.15/32" plywood Fasteners: #9-15 HWH corrosion resistant fasteners with sealing washers, metal to wood connections with fastener length to penetrate 5/16" through substrate per Florida Building Code 2014, Section 1507.4.4 Conditions of Use: Not for use in HVHZ. Install per manufacturer's instructions and must be designed In compliance with Florida Building Code 2014. Manufacturer is compliant with Rule 61G20-3; wherein manufacturer complies under a quality assurance program audited by approved Quality Assurance Entity; Keystone Certifications valid thru 4/11/2021 Evidence Submitted: a. UL 580/TAS 125 Tests for Uplift Resistance b. Reference -Test Report 0224=0501-06 Hurricane Test Laboratory ��ti�t,tt„r�r� C. Test equivalency standard - the UL 580-94 test standard is equiA, nao ®t gf,5A0-06 d. Quality Assurance -Procedures and Documentation %CENSF ° �;���'��� No.4�3"/04 -_ O o STATr��v"-T 0 FL This report does not guarantee or warranty any product validated.or installed. Manufacturer's warranty applies. 5 V Crimp Fastener- #9-15 corrosion resistant w/sealing washers 24" coverage Fastener: #9 x 15 corrosion resistant with sealing washers in Compliance with 2014 Florida Building Code, Section 1507.4.4 Perimeter fastening: 6"o.c. Main Field fastening12"o.c. Panel Width: 26" Panel Coverage: 24"maximum 26 GA Architectural Metal Roof panel