HomeMy WebLinkAboutEPL Display CardFORM R405-2014 ENERGY PERFORMANCE LE�/E / �+ kTiff DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*'= 100 The lower the EnergyPerformance Index, the more efficient the home.. Fort Pierce, FL, 1. New construction or existing New (From Plans) .9. Wall Types Insulation Area +� 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=11.0 1200.00 ft2_ b. Concrete Block - Int Insul, Exterior R=4.1 914.33 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11..0 290.33 ft2 4. Number of Bedrooms - 4 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1300.00 ft2 6. Conditioned floor. area (ft2) 2195 b. N/A . R= ft2 c. N/A R= ft2 7. Windows- Description Area a. U-Factor: Dbl, U=0.54 232.09 ft2 11. Ducts a:. Sup: Attic, Ret: 2nd Floor; AH: 2nd Floor z R ft 6 439 SHGC: SHGC=0.24 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.6 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 32.8 HSPF:8.20 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.240 8. Floor Types Insulation Area 14. Hot water systems Cap: 50 gallons a. Slab -On -Grade Edge Insulation_ R=0.0 920.00 ft 2 a. Electric EF: 0.9 b. Floor Over Other Space R=0.0 895.00 ft2 c. other (see details) R= 380.00 ft2 b. Conservation features. None 15. Credits Pstat I certify that this home has compli ith the Construction through the ab ener savir in this home before final i pectio . Othe based on installed Co . comq ' nt featur z Builder Signature: Address of New Home: /-j3(o Q Energy Efficiency Code, for Building as. which will be installed (or exceeded) w EYL Display Card will be completed Date: 7-.)-r G✓' City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492.or seethe EnergyGauge web site at energygauge.com for information and a list of certified Raters. For, information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required -by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/27/2017-2:29 PM EnergyGauge® USA - FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 9 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION . Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 007 2195 B RHG Flex - E Builder Name: One Stop Cooling and Heating Street: }�Qg g'a p"a" t&z4C(�C4C-, Permit Office: St. Lucie City, State, Zip: Fort Pierce , FL , Permit Number:: Owner: Ryan Homes Jurisdiction: 661000 Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 1. New construction or existing New (From Plans) 9. Wall Types (2404.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood; Exterior R=11.0 1200.00 ftz b. Concrete Block-`Int-Insul, Exterior R=4.1 914.33 ftz 3. ' Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 290.33 ft2 4. Number of Bedrooms 4 d. N/A R= ftz 10. Ceiling Types (1300.0 sqft.) Insulation Area 5. Is this a worst case? No a: "Under Attic (Vented) R=30.0 ' 1300.00 ftz 6. Conditioned floor area above grade (ftz) 2195 b. N/A " R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(232.1 sqft.) Description Area a. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 439' a. U-Factor: Dbl, U=0.54 232.09 ftz SHGC: SHGC=0.24 b. U-Factor: N/A ftz 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.6 SEER:14.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U.-Factor: N/A ftz a. Electric Heat Pump 32.8 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 6.240. 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2195.0. sqft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 920.00 ftz b. Conservation features b. Floor Over Other Space R=0.0 895.00 ftz None o. other (see details) R= 380.00 ftz 15. Credits . Pstat Total Proposed Modified'Loads: '69.45' Glass/Floor Area: 0.106 PASS •Total Baseline Loads: 69.73 I hereby certify that the'plans And 'specifications covered by Review of the plans and kiE ft this calculation are in compliance with the Florida Energy specifications covered by this , - 0 Code. Digitally signed by Michael calculation indicates compliance p Michael Conway Cconway with the Florida Energy Code. Date: 2017.07.27 14:31:56 -04'00' PREPARED BY: ��l Before construction is completed DATE: this building will be inspected for compliance -with Section 551908 i I he certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. :; ;_� - •' CQD with yq'S¢ OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires -an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a. proposed duct leakage On requires a Duct Leakage'Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.080 On for whole house. 7/27/2017 2:29 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software I I Page 1 of 4 FORM R405-20.14 PROJECT Title: Lot 007 2195 B RHG Flex - E Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2195 Lot # 007 - Owner: Ryan Homes Total Stories: 2 Block/SubDivision: Oakland Lake Pa # of Units: 1 Worst Case: No PlatBook: Builder Name: One Stop Cooling and Heatin Rotate Angle: 0 Street: Permit Office: St. Lucie Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp . v Design Location . TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI . 2 39 90, 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blocki 2195 18204 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 920 8004 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 1275 10200 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor over Garage 2nd Floor ---- ---- 380 ftz 11 0.29 0 0.71 2 Slab -On -Grade Edge Insulatio 1st Floor 105.5 ft 0 920 ftz ---- 0.29 0 0.71 3 Floor Over Other Space 2nd Floor ---- ---- 895 ftz 0 0.29 0 0.71 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1408 ftz 0 ftz Dark 0.6 N 0.6 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1300 ftz N N 7/27/2017 2:29 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) 1st Floor 30 Blown 1300 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Frame - Wood 2nd Floor 11 35 0 8 0 280.0 ft2 0 0.25 0.6 0 2 N Exterior Concrete Block - Int Insul 1 st Floor 4.1 16 0 8 8 138.7 ft2 0 0 0.6 0 3 E Exterior Frame - Wood 2nd Floor 11 40 0 8 - 0 320.0 ft2 0 0.25 0.6 0 4 E Exterior Concrete Block - Int Insul 1 st Floor 4.1 20 0 8 8 173.3 ft2 0 0 0.6 0 5 S Exterior Frame - Wood 2nd Floor 11 35 0 8 0 -280.0 ft2 0 0.25 0.6 0 6 S Exterior Concrete Block - Int Insul 1st Floor 4.1 29 6 8 8 255.7 ft2 0 0 0.6 0 7 W Exterior Frame - Wood 2nd Floor 11 40 0 8 0 320.0 ft2 0 0.25 0.6 0 8 W Exterior Concrete Block - Int Insul 1st Floor 4.1 40 0 `8 8 346.7 ft2 0 0 0.6 0 9 Garage Frame - Wood 1 st Floor 11 33 6 _8 8 290.3 ft2 0 0.25 0.6 0 DOORS # Ornt Door Type Space Storms U-Value. Width Height Area Ft In Ft In 1 E Insulated 1st Floor None .4 3 6 8 20 ft2 2 Wood 1st Floor None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is'the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 n 1 Metal Low-E Double Yes 0.54 0.24 1 5.3ft2 1 ft 0 in 1 ft 0 in. Drapes/blinds None 2 e 3 Metal Low-E Double Yes 0.54 0.24 8.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 3 e 3 Metal Low-E Double Yes 0.54 '0.24 61.2 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 e 4 Metal Low-E Double Yes 0.54 0.24 23.4 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 w 7 Metal Low-E Double Yes 0.54 0.24 . 45.9 ft2 1 ft 0 in 1 ft 0 in . Drapes/blinds None 6 w 8 Metal Low-E Double Yes 0.54 0.24 45.0 ft2 1 ft 0 in 1 ft 0 in Drapess/blinds None 7 W 8 Metal Low-E Double Yes 0.54 0.24 33.3 ft2 1 ft 0 in 1 ft 0 in -None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 444 ft2 384 ft2 64 ft 8.7 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000211 1213.6 66.62 125.3 .1894 4 7/27/2017 2:29 PM EnergyGauge@ USA - FlaRes2014 Section 13405.4.1 Compliant Software Page 8 of 4 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 32.8 kBtu/hr 1 sys#1 COOLING SYSTEM.. # System Type. Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 34.6 kBtu/hr 1038 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 439 ftz 2nd Floor .109.75 Proposed Qn 2nd Floor --- cfm 175.6 cfm 0.08 0.50 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[ Heatin[X} Jan H Feb Mar Jan Feb X� Mar Apr E APr f May Jun Jul Au Mayf Jun Jul AuSep. Se Oct Oct Nov Nov Dec Dec Venting[ ] Jan Feb Xl Mar lXl Apr l May l Jun Jul Aug Se Oct X Nov Dee Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling,(WD) AM. 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 .78 78 78 '78 78 .78 78 78 Heating (W D) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/27/2017 2:29 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Fort Pierce , FL , MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085, Florida Statues] requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2, and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. O R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors. no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400'or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed. to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior will or ceiling covering. ' 13 R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing (Mandatory)AII ducts, air handlers, and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post -construction or rough -in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes, or as authorized by Florida Statutes, to be "substantially leak free" by either of the following: 1. Post -construction test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. 2. Rough -in test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa) across the system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm (85 Umin) per 100 square feet (9.29 m2) of conditioned floor area. Exceptions: The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 7/27/2017 2:29 PM EnergyGauge@ USA FlaRes2014 - Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS (Continued) R403.2.3 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 55°F (13°C) shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems (Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3.1/2 inches (89 mm) in the,hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies (Mandatory). O R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 600C). • R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table 0404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol, Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment (Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation'of the building-. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible.and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors which affect equipment sizing. System sizing calculations shall not include loads created. by local intermittent mechanical ventilation such as 'standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that.its total capacity is not less than the calculated total load, but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 7/27/2017 2:29 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403:6.1.1 Cooling equipment capacity. (continued) The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling -only equipment. This selection shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(sf is installed in an unconditioned space. Exceptions: Attached single- and multi -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80.percent of that load. When signed and sealed by a Florida -registered engineer, in attached single- and multi -family units, the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section 11403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the.following options: A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. ' A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls (Mandatory). Snow and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F, and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools, inground spas and portable spas (Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15. The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on -off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil -fired pool and spa heaters. All gas- and oil -fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site -recovered energy, such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment (Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low -voltage lighting shall not be required to utilize high -efficacy lamps. O R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights .❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY.' Ceilings shall have minimum insulation of R-19. Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is, allowed. 7/27/2017 2:29 PM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Com Page 3 of 3