HomeMy WebLinkAboutAPPROVED REVISION - 14604.5 Single Hung Window
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL14604-R10
Application Type Revision
Code Version 2020
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the
Commission if necessary.
Comments
Archived
Product Manufacturer Eastern Architectural Systems
Address/Phone/Email 16341 Domestic Ave.
Ft. Myers, FL 33912
(800) 432-2204 Ext 4305
jflesher@easternmetal.com
Authorized Signature James Flesher
jflesher@easternmetal.com
Technical Representative Jim Flesher
Address/Phone/Email 10030 Bavaria Rpad
Fort Myers, FL 33913
(800) 432-2204
jflesher@easternmetal.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
Referenced Standard and Year (of Standard)Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2011
ASTM E1886 2012
ASTM E1996 2012
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL14604_R10_Equiv_FL14604 AAMA EQ.pdf
FL14604_R10_Equiv_FL14604 ASTM EQ.pdf
Product Approval Method Method 1 Option A
Date Submitted 10/24/2020
Date Validated 10/26/2020
Date Pending FBC Approval
Date Approved 11/03/2020
Summary of Products
FL #Model, Number or Name Description
14604.1 Series 1431 Non-Impact Vinyl SH Nailing Fin Series 1431 Non-Impact Vinyl SH Nailing Fin
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Configuration: O/X Vent Size: W-44.38" H-35" Glazing: 3/4" Overall I.G.
Certification Agency Certificate
FL14604_R10_C_CAC_NI010607-R3.pdf
Quality Assurance Contract Expiration Date
12/31/2024
Installation Instructions
FL14604_R10_II_08-00556B.pdf
Verified By: Luis R. Lomas, P.E. Florida P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14604_R10_AE_510945A.pdf
Created by Independent Third Party: Yes
14604.2 Series 1441 Non-Impact Vinyl SH Flange Series 1441 Non-Impact Vinyl SH Flange
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Configuration: O/X Vent Size: W-50.38" H-35.13" Glazing: 3/4" Overall
I.G.
Certification Agency Certificate
FL14604_R10_C_CAC_NI010813-R3.pdf
Quality Assurance Contract Expiration Date
04/30/2024
Installation Instructions
FL14604_R10_II_08-00558C.pdf
Verified By: Luis R. Lomas, P.E. Florida P.E. 61514
Created by Independent Third Party: Yes
Evaluation Reports
FL14604_R10_AE_510947B.pdf
Created by Independent Third Party: Yes
14604.3 Series 2451 Impact Vinyl SH Nailing Fin Series 2451 Impact Vinyl SH Nailing Fin
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: Configuration: O/X Max. Frame Size: W-48" H-72" Max. Vent Size: W-
44.25" H-35" Glazing: 3/4" Overall Laminated IG
Certification Agency Certificate
FL14604_R10_C_CAC_NI012533-R2.pdf
Quality Assurance Contract Expiration Date
02/28/2022
Installation Instructions
FL14604_R10_II_08-00562B.pdf
Verified By: Luis R. Lomas, P.E. Florida P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14604_R10_AE_510951A.pdf
Created by Independent Third Party: Yes
14604.4 Series 2451 Impact Vinyl SH Nailing Fin Series 2451 Impact Vinyl SH Nailing Fin
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: Configuration: O/X Max. Frame Size: W-48" H-72" Glazing: 3/4" Overall
Laminated IG
Certification Agency Certificate
FL14604_R10_C_CAC_NI013364.02-R1.pdf
Quality Assurance Contract Expiration Date
09/30/2024
Installation Instructions
FL14604_R10_II_08-02914.pdf
Verified By: Luis R. Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14604_R10_AE_513739A.pdf
Created by Independent Third Party: Yes
14604.5 Series 2461 Impact Vinyl SH Flange Series 2461 Impact Vinyl SH Flange
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: O/X Max. Frame Size: W-53 1/8" H-72" Glazing: 3/4" Overall Laminated IG
Certification Agency Certificate
FL14604_R10_C_CAC_NI013364.03-R1.pdf
Quality Assurance Contract Expiration Date
09/30/2024
Installation Instructions
FL14604_R10_II_08-02915.pdf
Verified By: Luis R. Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14604_R10_AE_513740A.pdf
Created by Independent Third Party: Yes
14604.6 Series 2461 Impact Vinyl SH Flange Series 2461 Impact Vinyl SH Flange
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: Configuration: O/X Vent Size: W-51" H-34.5" Glazing: 3/4" Overall
Laminated IG
Certification Agency Certificate
FL14604_R10_C_CAC_NI012533.01-R3.pdf
Quality Assurance Contract Expiration Date
02/28/2022
Installation Instructions
FL14604_R10_II_08-00564B.pdf
Verified By: Luis R. Lomas, P.E. Florida P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14604_R10_AE_510953B.pdf
Created by Independent Third Party: Yes
14604.7 Series FWI 1000 Impact Aluminum SH Series FWI 1000 Impact Aluminum SH
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See drawing 08-02476 for design pressures. GLASS INTERLAYER
COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE
ACCORDING TO MIAMI-DADE FOR EASTMAN INTERLAYERS
Certification Agency Certificate
FL14604_R10_C_CAC_NI009020.01-R3.pdf
FL14604_R10_C_CAC_NI009020.02-R2.pdf
FL14604_R10_C_CAC_NI009020.03-R2.pdf
FL14604_R10_C_CAC_NI010670.01-R1.pdf
FL14604_R10_C_CAC_NI010670-R2.pdf
Quality Assurance Contract Expiration Date
04/30/2021
Installation Instructions
FL14604_R10_II_08-02476A.pdf
Verified By: Luis R. Lomas, P.E. Florida P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL14604_R10_AE_513232B.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the
office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter
455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If
you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
CERTIFICATION NO: NI013364.03-R1
DATE: 01/17/2017
CERTIFICATION PROGRAM: Structural
COMPANY: Eastern
CODE: 1783-1
REVISION DATE: 04/29/2018
To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Eastern Architectural Systems Series “2461 SH”
16341 Domestic Avenue Vinyl Single Hung Window
Ft. Myers, FL 33912 w/Equal Leg Frame
Configuration: O/X
Glazing: IG-1/8" Annealed Glass/Laminate-1/8" Annealed
Glass/0.090" Eastman Interlayer/1/8" Annealed Glass
Frame: W-1349mm(53.13") H-1829mm(72")
Sash: W-1295mm(51") H-876mm(34.5")
DLO: W-1222mm(48.13") H-829mm(32.63")
SPECIFICATION PRODUCT RATING
AAMA 506-08
ASTM E1886-02/E1996-02
AAMA/WDMA/CSA 101/I.S.2/A440-05
H-R50 1349 x 1829 (53 x 72)
Design Pressure: ±2400 Pa (±50 psf)
Water Penetration Resistance Test Pressure: 359 Pa(7.5 psf)
Wind Zone 4 - Missile Level D
Product Tested By: Element Materials Technology
Report No: ESP009376P-8R/010455P-8R/CTLA 2062W-8/W-1797
Expiration Date:September 30, 2024
Administrator’s Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
NOTICE OF PRODUCT CERTIFICATION
L. Roberto Lomas P.E. Engineering Evaluation Report
1432 Woodford Rd.
Lewisville, NC 27023 Report No.: 513740A
434-688-0609
rllomas@lrlomaspe.com
1 of 1 Luis R. Lomas, P.E.
FL No.: 62514
10/19/2020
Manufacturer: Eastern Architectural Systems
16341 Domestic Ave.
FT Myers, FL 33912
Product Line: Series 2461 Vinyl Flange Frame Single Hung Window - Impact
Compliance:
The above mentioned product has been evaluated for compliance with the requirements o f the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a). The product listed
herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-02915 prepared, signed and sealed by Luis Roberto Lomas P.E.
2. Test Report No: CTLA 2062W-8 signed and sealed by Ramesh Patel, P.E.
Certified Testing Laboratories, Orlando, FL
ASTM E1886/ E1996 Large Missile Impact Test, Level D, Wind Zone 4
Cyclic Load Test, ±50.0 psf. design pressure
3. Test Report No.: ESP009376P-8R signed and sealed by Ramesh Patel, P.E.
Element Materials Technology, Wausau, WI
AAMA/WDMA/CSA 101/I.S.2/A440
Design pressure: ±50.0psf
Water penetration resistance 7.5psf
4. Anchor calculations, report number 513740-1, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
Maximum design pressure: ±50.0psf
Maximum unit size: 53 1/8" x 72”
Units must be glazed per ASTM E1300 see installation instructions for glass details.
This product is not rated to be used in the HVHZ.
This product is impact resistant and does not require impact protection in wind borne debris regions.
Frame material to be rigid PVC.
Installation:
Units must be installed in accordance with manufacturer’s installation instructions and approval document, 08-02915.
Certification of Independence:
Please note that I don’t have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don’t have nor will acquire a financial interest in any other entit y
involved in the approval process of the listed product(s).
A. (2) FS-550 SPRING LOADED BALANCE SYSTEM AT EACH JAMB
B. (2) METALLIC TILT LATCH SPRING LOADED AT 1 1/2" FROM EACH SASH TOP RAIL
C. (2) ALUMINUM IMPACT CLIP REINFORCEMENT AT 1 1/2" FROM EACH SASH TOP RAIL
D. (2) CAST ALUMINUM CAM LOCKS AT 10" FROM EACH JAMB ON SASH TOP RAIL
E. EXTRUDED ALUMINUM REINFORCEMENT AT FIXED MEETING RAIL
F. EXTRUDED ALUMINUM REINFORCEMENT AT SASH STILES & RAILS
G. (2) METALLIC SILL INTERLOCKS AT FRAME SILL 15" FROM EACH SILL CORNER
HARDWARE SCHEDULE