Loading...
HomeMy WebLinkAboutAPPROVED REVISION - 14604.5 Single Hung Window BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL14604-R10 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800) 432-2204 Ext 4305 jflesher@easternmetal.com Authorized Signature James Flesher jflesher@easternmetal.com Technical Representative Jim Flesher Address/Phone/Email 10030 Bavaria Rpad Fort Myers, FL 33913 (800) 432-2204 jflesher@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard)Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E1886 2012 ASTM E1996 2012 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL14604_R10_Equiv_FL14604 AAMA EQ.pdf FL14604_R10_Equiv_FL14604 ASTM EQ.pdf Product Approval Method Method 1 Option A Date Submitted 10/24/2020 Date Validated 10/26/2020 Date Pending FBC Approval Date Approved 11/03/2020 Summary of Products FL #Model, Number or Name Description 14604.1 Series 1431 Non-Impact Vinyl SH Nailing Fin Series 1431 Non-Impact Vinyl SH Nailing Fin Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configuration: O/X Vent Size: W-44.38" H-35" Glazing: 3/4" Overall I.G. Certification Agency Certificate FL14604_R10_C_CAC_NI010607-R3.pdf Quality Assurance Contract Expiration Date 12/31/2024 Installation Instructions FL14604_R10_II_08-00556B.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R10_AE_510945A.pdf Created by Independent Third Party: Yes 14604.2 Series 1441 Non-Impact Vinyl SH Flange Series 1441 Non-Impact Vinyl SH Flange Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configuration: O/X Vent Size: W-50.38" H-35.13" Glazing: 3/4" Overall I.G. Certification Agency Certificate FL14604_R10_C_CAC_NI010813-R3.pdf Quality Assurance Contract Expiration Date 04/30/2024 Installation Instructions FL14604_R10_II_08-00558C.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 61514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R10_AE_510947B.pdf Created by Independent Third Party: Yes 14604.3 Series 2451 Impact Vinyl SH Nailing Fin Series 2451 Impact Vinyl SH Nailing Fin Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Configuration: O/X Max. Frame Size: W-48" H-72" Max. Vent Size: W- 44.25" H-35" Glazing: 3/4" Overall Laminated IG Certification Agency Certificate FL14604_R10_C_CAC_NI012533-R2.pdf Quality Assurance Contract Expiration Date 02/28/2022 Installation Instructions FL14604_R10_II_08-00562B.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R10_AE_510951A.pdf Created by Independent Third Party: Yes 14604.4 Series 2451 Impact Vinyl SH Nailing Fin Series 2451 Impact Vinyl SH Nailing Fin Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Configuration: O/X Max. Frame Size: W-48" H-72" Glazing: 3/4" Overall Laminated IG Certification Agency Certificate FL14604_R10_C_CAC_NI013364.02-R1.pdf Quality Assurance Contract Expiration Date 09/30/2024 Installation Instructions FL14604_R10_II_08-02914.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R10_AE_513739A.pdf Created by Independent Third Party: Yes 14604.5 Series 2461 Impact Vinyl SH Flange Series 2461 Impact Vinyl SH Flange Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: O/X Max. Frame Size: W-53 1/8" H-72" Glazing: 3/4" Overall Laminated IG Certification Agency Certificate FL14604_R10_C_CAC_NI013364.03-R1.pdf Quality Assurance Contract Expiration Date 09/30/2024 Installation Instructions FL14604_R10_II_08-02915.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R10_AE_513740A.pdf Created by Independent Third Party: Yes 14604.6 Series 2461 Impact Vinyl SH Flange Series 2461 Impact Vinyl SH Flange Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Configuration: O/X Vent Size: W-51" H-34.5" Glazing: 3/4" Overall Laminated IG Certification Agency Certificate FL14604_R10_C_CAC_NI012533.01-R3.pdf Quality Assurance Contract Expiration Date 02/28/2022 Installation Instructions FL14604_R10_II_08-00564B.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R10_AE_510953B.pdf Created by Independent Third Party: Yes 14604.7 Series FWI 1000 Impact Aluminum SH Series FWI 1000 Impact Aluminum SH Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See drawing 08-02476 for design pressures. GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR EASTMAN INTERLAYERS Certification Agency Certificate FL14604_R10_C_CAC_NI009020.01-R3.pdf FL14604_R10_C_CAC_NI009020.02-R2.pdf FL14604_R10_C_CAC_NI009020.03-R2.pdf FL14604_R10_C_CAC_NI010670.01-R1.pdf FL14604_R10_C_CAC_NI010670-R2.pdf Quality Assurance Contract Expiration Date 04/30/2021 Installation Instructions FL14604_R10_II_08-02476A.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R10_AE_513232B.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: CERTIFICATION NO: NI013364.03-R1 DATE: 01/17/2017 CERTIFICATION PROGRAM: Structural COMPANY: Eastern CODE: 1783-1 REVISION DATE: 04/29/2018 To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series “2461 SH” 16341 Domestic Avenue Vinyl Single Hung Window Ft. Myers, FL 33912 w/Equal Leg Frame Configuration: O/X Glazing: IG-1/8" Annealed Glass/Laminate-1/8" Annealed Glass/0.090" Eastman Interlayer/1/8" Annealed Glass Frame: W-1349mm(53.13") H-1829mm(72") Sash: W-1295mm(51") H-876mm(34.5") DLO: W-1222mm(48.13") H-829mm(32.63") SPECIFICATION PRODUCT RATING AAMA 506-08 ASTM E1886-02/E1996-02 AAMA/WDMA/CSA 101/I.S.2/A440-05 H-R50 1349 x 1829 (53 x 72) Design Pressure: ±2400 Pa (±50 psf) Water Penetration Resistance Test Pressure: 359 Pa(7.5 psf) Wind Zone 4 - Missile Level D Product Tested By: Element Materials Technology Report No: ESP009376P-8R/010455P-8R/CTLA 2062W-8/W-1797 Expiration Date:September 30, 2024 Administrator’s Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 NOTICE OF PRODUCT CERTIFICATION L. Roberto Lomas P.E. Engineering Evaluation Report 1432 Woodford Rd. Lewisville, NC 27023 Report No.: 513740A 434-688-0609 rllomas@lrlomaspe.com 1 of 1 Luis R. Lomas, P.E. FL No.: 62514 10/19/2020 Manufacturer: Eastern Architectural Systems 16341 Domestic Ave. FT Myers, FL 33912 Product Line: Series 2461 Vinyl Flange Frame Single Hung Window - Impact Compliance: The above mentioned product has been evaluated for compliance with the requirements o f the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a). The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-02915 prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Test Report No: CTLA 2062W-8 signed and sealed by Ramesh Patel, P.E. Certified Testing Laboratories, Orlando, FL ASTM E1886/ E1996 Large Missile Impact Test, Level D, Wind Zone 4 Cyclic Load Test, ±50.0 psf. design pressure 3. Test Report No.: ESP009376P-8R signed and sealed by Ramesh Patel, P.E. Element Materials Technology, Wausau, WI AAMA/WDMA/CSA 101/I.S.2/A440 Design pressure: ±50.0psf Water penetration resistance 7.5psf 4. Anchor calculations, report number 513740-1, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use:  Maximum design pressure: ±50.0psf  Maximum unit size: 53 1/8" x 72”  Units must be glazed per ASTM E1300 see installation instructions for glass details.  This product is not rated to be used in the HVHZ.  This product is impact resistant and does not require impact protection in wind borne debris regions.  Frame material to be rigid PVC. Installation: Units must be installed in accordance with manufacturer’s installation instructions and approval document, 08-02915. Certification of Independence: Please note that I don’t have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don’t have nor will acquire a financial interest in any other entit y involved in the approval process of the listed product(s). A. (2) FS-550 SPRING LOADED BALANCE SYSTEM AT EACH JAMB B. (2) METALLIC TILT LATCH SPRING LOADED AT 1 1/2" FROM EACH SASH TOP RAIL C. (2) ALUMINUM IMPACT CLIP REINFORCEMENT AT 1 1/2" FROM EACH SASH TOP RAIL D. (2) CAST ALUMINUM CAM LOCKS AT 10" FROM EACH JAMB ON SASH TOP RAIL E. EXTRUDED ALUMINUM REINFORCEMENT AT FIXED MEETING RAIL F. EXTRUDED ALUMINUM REINFORCEMENT AT SASH STILES & RAILS G. (2) METALLIC SILL INTERLOCKS AT FRAME SILL 15" FROM EACH SILL CORNER HARDWARE SCHEDULE