Loading...
HomeMy WebLinkAboutCertification For Design Load ComplianceRECEIVc-D AUG ol ?017 Planning & Devel I opment I Services Department Building $L Code Regulations .Divis - ion 2360 Virginia Avenue, Fort Pierce, FL 34982' (772) 462ASS3 Certification for Design Load Compliance Project Name: Johnny Rambo Project Address: 2300, Canoe Creek Lane. Fort Pierce, FL 34981 Permit 9: Occupancy Type: 'Single Family Construction Type:: CBS — INSTRUCTIONS FOR USE: • This certification must be completed, s . igned,and sealed by the design prof ess.i onal,of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: . o New Residences (single or multi-farnily) o Resident.lai Addition o Any accessory structure requiring ai building permit 6 Any non-residential Aructur6. Note: Form not required for Interior renovations provided that no exterior structural elements are affected and certain minor building petrnits.at the discretion of the local building official. Ontact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that 6001y) 1.- bEtld'k CODE: Florida BUILDING 'Code FifihLEditionwiih 2614 'Supplements using ASCE 7-10 2.. Struqt . ire Designed as (check one): XEnclosed Partially Enclosed Open 3. Risk Cat6 gqrV: If .111 IV Exposure Category: B x C D 4. Design Wind Velocity 17Q mph ASD LRFD End Zone Width: ft S. Mean Roof Height 15 —ft Roof Pitch: 5 12 Parapet: ft 0. C61moone.rit-4 & Cladding Design Pressures Usdd:,(PSF, based on 10sqftLcD.jVMRA,. clearly label on all plan openings): 1:.21.6/44.9 Zone 1: .21 ��/fo-7 Zone 121.111-80.8 Zone 4:30'0'ff� 2 0/ Zone t:38.-�0.8 Garage: T. Design Loads: Floor.. 40 PSF Ro6f/Dead: L5_PSF Roof/Live: I 30, Balcony: PSF: . I Docks PSF Deck: _PSF Stairs! PSF Fence: -PSF __.�$F Rallings:_ - 8. Were Shear Walls Considered For,Struifture?,2L_Yes Not Applicable Explain Why Not: t9. IsAtontinuous Load Path Provided? X 'Yes Not A In Applicable Explain Why L-��PSF Soli Test Reports Submitted?. Sj 00 10, Pbsign,Soil Mating Pressure: ! DESIGN PROFESSIONAL CERTIFICATION STATEMENT-. I certify that, to the best of my knowledge and belief, the attached plans specifications have been designed to comply� wqh *N, `66w, structural portioris'of the buiidin'g codes currently adopted and enforced by St. Lucie Cou'nlyi1o`,t'Q"Mt aixit ural elements depicted on these I' vidLi'adequate resistance to the design .ecti p ans provide � z 4C. JUL 2 8 MR... o CHRISTOPHER D. BEERS, P.E. 64504 Print Name Cert # & Co. CertAuth. WA L-TECH.1040 HARBOUR -DRAKE DR.. lk- N PUNTA GORDA, FL.,33983 ign Company Name &Address Revised 6725 2014