Loading...
HomeMy WebLinkAboutConstruction Inspection & Final InspectionRECEIVED STATE OF FLORIDA JUN 16 201 DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENfeM0n p=ft SYSTEM CONSTRUCTION INSPECTION ANDUVICCooEYAPPROVAL APPLICANT: Johnny Rambo AGENT: Brian Davis (Brian Davis Septic and Backhoe Services Inc.) PROPERTY ADDRESS.: 2300 Canoe Creek Ln Fort Pierce, FL 34981 APPLICATION #:AP1295581 PERMIT #:56-SF-1770999 DOCUMENT #:F11191063 DATE PAID:10/12/2017 FEE PAID :25.00 RECEIPT #:56-PID-3411656 LOT: 7 SUBDIVISION: BLOCK: ID#: 3404-701-0007=000-0 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE -AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] 101] TANK SIZE (1] -1090.00 [2] [ ] [27] SURFACE WATER FT [ ] [021 TANK MATERIAL Polyethylene [ ] [281 DITCHES 75 FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS 77 FT [ ] [041 MULTI -CHAMBERED JL2�j N ] [ ] [301 PUBLIC WELLS FT [ ] 105] OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11DC3 2. [ ] [32] POTABLE WATER 60 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 6 FT [ ] [081 LEVEL [ ] [34] PROPERTY LINES 75 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER , FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10) AREA - [1] 384.88 12] SQFT [ ] [361 DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [ 12 ] NUMBER OF DRAINLINES 1. 4.00 2. [ ] [ 38 ] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 06/13/2018 ( ] [141 DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ AHOVE / BELOW. ]BM 14.00 [ ] [401 UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL /iEXCAVATION MATERIAL [ [2] FILL AMOUNT [ ] [47] CONTRACTOR Brian Davis (Brian Davis Sept ] 2 [ ] 221 FILL TEXTURE [ ] 1481 OTHER . INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [49] TANK.PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. St. Lucie CHD DATE: 10/17/2017 CONSTRUCTION [ APPROVED / DISAPPROVED ] Environ ntal Specialist II J m (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: a CHO DATE: 06/13/2018 Environmental Specialist If Brian J ram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EID1770999 EH Database v 1.0.1 AP1295501 STATE OF FLORIDA. DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment flnmmen t s APPLICATION # : AP1295581 PERMIT #:56-SF-1770999 DOCUMENT # : FI 1191063 DATE PAID:1,0/12/2017 FEE PAID:25•00 RECEIPT #:56-PID-3411656 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 Ipd; New St and 2x9+2x8 DF installed. No violations, system ok to cover. Contractor notified by phone. No house. Needs final for vell check, potable water lines, building foundation, mound system, gutters, building area, location conforms with site plan, and inal site grading. Jo violations. Final system approved. Contractor and. building department emailed final approval. 0 DH 4016, 08/09 (Obsoleted all previous editions which may not be used) Incorporated: 64E-6.003, PAC Page 2 0£ 3 EH Database v1.0.1 AP1295581 EID1770999