HomeMy WebLinkAboutProject InformationRECEIVED Alit 01 ?0117 .� Load Short Form - Job: Rambo ,- ` p Calcs' ti 'Weare the missingpleca Entire House Date: July 13, 2017 Thomas Platania Digitally signed by Thomas By: Scott Pingleton — ProCalcs, LLC Platania CAC1815254 CAC1815254 Date:2017.07.1308:27:11-04'00' C�' P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project• • For: Rambo 2300 Canoe Creek Lane, Fort Pierce, FL 34981 Design Information Htg Clg Infiltration Outside db ('F) 37 91 Method Simplified Inside db (°F) 70 75 Construction quality Semi -loose Design TD ('F) 33 16 Fireplaces 0 Daily range - Inside humidity (%) 50 L 50 Moisture difference (gr/lb) 29 54 � HEATING EQUIPMENT Make Lennox Trade Lennox Model ECB29-8CB (121-52) AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 80 eF 310 cfm 0.011 cfm/Btuh 0.60 in H2O COOLING EQUIPMENT Make Lennox Trade LENNOX Cond 14ACX-030-230A** Coil CBX27UH-030-230*++TDR AHRI ref 7509923 Efficiency 13.0 EER, 16 SEER Sensible cooling 22400 Btuh Latent cooling 5600 Btuh Total cooling 28000 Btuh Actual air flow 933 cfm Air flow factor 0.042 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 0.79 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Master Suite 266 5084 2318 57 98 Master Bath 160 2445 1631 27 69 WIC 57 73 243 1 10 Living Room 161 3910 2496 44 106 Dining 198 4093 2761 46 117 Pantry 20 0 0 0 0 Kitchen 206 693 2698 8 114 Family Room 347 3416 4352 38 185 Bath 2 65 1021 496 11 21 Clos 2 23 0 0 0 0 Bedroom 2 171 4092 1806 46 77 Bedroom 3 159 2257 1915 25 81 Laundry 59 571 1283 6 54 1 ;_ 7 A n r% n n Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft® 2017-Jul-12 23:31:03 9 Right -Suite® Universal 2017 17.0.23 RSU23702 Page 1 ... ilders\Rambo\Working Drawings\Rambo Revised. rup Calc = MJ8 Front Door faces: N 1 n c11I n c11I JO U V V U Clos 6 0 0 0 0 Clos 3 12 0 0 0 0 Entire House 1950 27656 21998 310 933 Other equip loads 0 0 Equip. @ 1.00 RSM 21998 Latent cooling 5712 Tl1TA10 4Inc A mmn= -7774A 44A A44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. At + wrightsoft® Right -Suite® Universal 2017 17.0.23 RSU23702 2017-Jul-12 23:age 2 k6APage 2 ...ilders\Rambo\Working Drawings\Rambo Revised.rup Cale = MJS Front Door faces: N Building Analysis Job: Rambo `*" P�G�CAICS Date: July 13, 2017 `�? Entire House By: Scott Pingleton d We are the missing piece ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 For: Rambo 2300 Canoe Creek Lane, Fort Pierce, FL 34981 Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 28°N Outdoor: Heating Dry bulb (°F) 37 Daily range °F) - Wet bulb (°F Wind speed (mph) 15.0 Indoor: Heating Cooling Indoor temperature (°F) 70 75 Design TD (°F) 33 16 Relative humidity (%) 50 50 Cooling Moisture difference (gr/lb) 29.3 53.6 91 Infiltration: 15 ( L ) Method Simplified 77 Construction quality Semi -loose 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 4.4 6558 23.7 Glazing 11.0 1708 6.2 Doors 13.0 785 2.8 Ceilings 1.1 2084 7.5 Floors 3.0 5932 21.4 Infiltration 4.9 6185 22.4 Ducts 4405 15.9 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 27656 100.0 Component Btuh/ft2 Btuh % of load Walls 2.3 3472 15.8 Glazing 14.3 2219 10.1 Doors 11.7 708 3.2 Ceilings 1.7 3344 15.2 Floors 0 0 0 Infiltration 1.2 1576 7.2 Ducts 6585 29.9 Ventilation 0 0 Internal gains 4095 18.6 Blower 0 0 Adjustments 0 Total 21998 100.0 Latent Cooling Load = 5712 Btuh Overall U-value = 0.091 Btuh/ft2-°F Data entries checked. Infiltration sins W rl Ihltsoft® 2017-Jul-12 23:31:03 .�, g Right -Suite® Universal 2017 17.0.23 RSU23702 Page 1 ...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces: N t �' Project Summar Job: Rambo ` MD Ca1Cs Entire House Y Date: July 13, 2017 �• .. By: Scott Pingleton \ We are the missing place ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Vveb: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 For: Rambo 2300 Canoe Creek Lane, Fort Pierce, FL 34981 Notes: Groza Builders, Inc 511 SW Port St. Lucie Blvd Port St. Lucie, FL 34953 Weather: St Lucie Co Intl, FL, US Winter Design Conditions Outside db 37 °F Inside db 70 'F Design TD 33 °F Heating Summary Structure 23251 Btuh Ducts 4405 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 27656 Btuh Infiltration Method Simplified Construction quality Semi -loose Fireplaces 0 Heating Coolingg Area (ft2) 1950 1950 Volume (ft') 17136 17136 Air changes/hour 0.59 0.31 Equiv. AVF (cfm) 169 89 Heating Equipment Summary Make Lennox Trade Lennox Model ECB29-8CB (121-52) AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 80 'F 310 cfm 0.011 cfm/Btuh 0.60 in H2O Summer Design Conditions Outside db 91 'F Inside db 75 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Sensible Cooling Equipment Load Sizing Structure 15413 Btuh Ducts 6585 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 21998 Btuh Latent Cooling Equipment Load Sizing Structure 4024 Btuh Ducts 1688 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5712 Btuh Equipment Total Load (Sen+Lat) 27710 Btuh Req. total capacity at 0.80 SHR 2.3 ton Cooling Equipment Summary Make Lennox Trade LENNOX Cond 14ACX-030-230A** Coil CBX27UH-030-230*++TDR AHRI ref 7509923 Efficiency 13.0 EER, 16 SEER Sensible cooling 22400 Btuh Latent cooling 5600 Btuh Total cooling 28000 Btuh Actual air flow 933 cfm Air flow factor 0.042 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl Ihltsoftm 2017-Jul-12 23:31:03 .+- Right -Suite® Universal 2017 17.0.23 RSU23702 Page 1 A'CA ...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces: N � ���� Right-JtWorksheet ' W.m�.m.�°�••• Entire House ProCalcs, LLC Job: Rambo Date: July 13, 2017 By: Scott Pingleton P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Entire House Master Suite 2 Exposed wall 150.5 ft 33.0 ft 3 Room height 8.8 ft 8.0 ft heat/cool 4 Room dimensions 14.0 x 19.0 ft 5 Room area 1949.5 ft' 266.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft� Load number (Btuh/f:2 °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W. Block Foam Fill R-9 0.143 n 4.79 2.77 445 367 1757 1018 112 90 429 249 2 glazing, clr low-e 0.330 n 11.02 9.08 16 0 171 141 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 22 0 247 203 22 0 247 203 4A5-2ovd 0.330 n 11.02 9.08 40 0 443 365 0 0 0 0 11 IW Block Foam Fill R-9 0.143 a 4.79 2.77 368 356 1704 987 152 152 728 422 �--G 2 glazinq, cir low-e 0.330 a 11.02 26.99 12 0 135 331 0 0 0 0 W Block Foam Fill R-9 glazing, clr low-e 0.143 0.330 s s 4.79 11.02 2.77 11.21 277 22 188 40 899 247 521 251 0 0 0 0 0 0 0 0 IE;2 2 glazing, clr low-e 0.330 s 11.02 19.08 27 53 295 510 0 0 0 0 D 11D0 0.390 s 13.03 11.74 40 40 524 472 0 0 0 0 W. Block Foam Fill R-9 0.143 w 4.79 2.77 180 165 788 456 0 0 0 0 2 glazing, cir low-e 0.330 w 11.02 26.99 16 0 171 418 0 0 0 0 P Partition Wall 0.101 - 3.38 1.17 437 417 1411 490 0 0 0 0 11D0 0.390 n 13.03 11.74 20 20 262 236 0 0 0 0 C 1613-30ad 0.032 - 1.07 1.72 1950 1950 2084 3344 266 266 284 456 F 22A-tpm 1.180 - 39.41 0.00 1950 151 5932 0 266 33 1301 0 6 c) AED excursion 0 -33 Envelope loss/gain 17066 9742 2989 1297 12 a) Infiltration 6185 1576 1286 328 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 4 920 0 0 Appliances/other 3175 0 Subtotal (lines 6 to 13) 1 23251 15413 4274 1624 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23251 15413 4274 1624 15 Duct loads 19% 43% 4405 6585 19% 43% 810 694 Total room load 27656 219981 5084 2318 Air required (cfm) 310 9331 57 98 Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed. wrightsoftm �2017-Jul-12 23:31:03 � Right -Suite® Universal 2017 17.0.23 RSU23702 Page 1 ...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces: N Ri ht-J®Worksheet V;U� lcs 9 1 Entire House ProCalcs, LLC Job: Rambo Date: July 13, 2017 By: Scott Pingleton P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Master Bath WIC 2 Exposed wall 15.5 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 159.6 ft 159.6 ft2 1.0 x 57.4 ft 57.4 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft� Load number (Btuh/W °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coal 6 W. Black Foam Fill R-9 0.143 n 4.79 2.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 11 IW 4A5-2ovd Block Foam Fill R-9 0.330 0.143 n a 11.02 4.79 9.08 2.77 0 124 0 112 0 535 0 310 0 0 0 0 0 0 0 0 - G 2 glazing, clr law-e 0.330 a 11.02 26.99 12 0 135 331 0 0 0 0 IW Black Foam Fill R-9 2 glazing, clr low-e 0.143 0.330 s s 4.79 11.02 2.77 11.21 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 s 11.02 19.08 0 0 0 0 0 0 0 0 D 11 DO 0.390 s 13.03 11.74 0 0 0 0 0 0 0 0 W. Block Foam Fill R-9 0.143 w 4.79 2.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 11.02 26.99 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 3.38 1.17 0 0 0 0 0 0 0 0 11 DO 0.390 n 13.03 11.74 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 - 1.07 1.72 160 160 171 274 57 57 61 98 F 22A-tpm 1.180 - 39.41 0.00 160 16 611 0 57 0 0 0 6 c) AED excursion 75 -3 Envelope loss/gain 1452 989 61 95 12 a) Infiltration 604 154 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 75 Subtotal (lines 6 to 13) 2056 1143 61 170 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2056 1143 61 170 15 Duct loads 19% 43% 389 488 19% 43% 12 73 Total room load 2445 1631 73 243 Air required (cfm) 27 69 1 10 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. .R ;Z- � Wrightsaft" Right -Suite® Universal,2017 17.0.23 RSU23702 2017-Jul-12 2 Page 2 ...ilders\Rambo\Working Drawings%Rambo Revised.rup Calc = MJ8 Front Door faces: N i .pGt�Calcs Right-.�0 Worksheet w••mN•�� gp Entire House ProCalcs, LLC Job: Rambo Date: July 13, 2017 By: Scott Pingleton P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Living Room Dining 2 Exposed wall 25.5 ft 16.5 ft 3 Room height 8.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 14.0 x 11.5 ft 161.0 ft' 16.5 x 12.0 ft 198,0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (W) Load number (Btuh/ft? •F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VhBlock Foam Fill R-9 0.143 n 4.79 277 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 11 W 1 4A5-2ovd Block Foam Fill R-9 0.330 0.143 n a 11.02 4.79 9.08 2.77 0 92 0 92 0 441 0 255 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 a 11.02 26.99 0 0 0 0 0 0 0 0 W Block Foam Fill R-9 glazing, dr low-e 0.143 0.330 s s 4.79 11.02 2.77 11.21 112 22 90 20 429 247 249 251 165 0 98 0 470 0 272 0 L;2 2 glazing, clr low-e 0.330 s 11.02 19.08 0 0 0 0 27 27 295 510 D 11D0 0.390 s 13.03 11.74 0 0 0 0 40 40 524 472 1 Block Foam Fill R-9 0.143 w 4.79 2.770 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 11.02 26.99 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 3.38 1.17 0 0 0 0 120 120 406 141 11DO 0.390 n 13.03 11.74 0 0 _ 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.07 1.72 161 161 172 276 198 198 212 340 F 22A-tpm 1.180 - 39.41 0.00 161 26 1005 0 198 17 650 0 6 c) AED excursion -36 -39 Envelope loss/gain 2294 995 2556 1696 12 a) Infiltration 993 253 804 205 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13) 3287 1748 3359 1900 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 82 34 14 Subtotal 3287 1748 3441 1934 15 Duct loads 19% 43% 623 747 19% 43% 652 826 Total room load 3910 24961 4093 2761 Air required (cfm) 44 1061 46 117 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. ACCP. +WYightsoTt` 2017-Jul-12 2 Right -Suite@ Universal 2017 17.0.23 RSU23702 Page 3 ...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces: N Rig ht-AD-Worksheet Calcs 9 w•°°w°m°•�°°�°° Entire House ProCalcs, LLC Job: Rambo Date: July 13, 2017 By: Scott Pingleton P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Pantry Kitchen 2 Exposed wall O ft O ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 19.8 ft 1.0 x 205.8 ft 5 Room area 19.8 f12 205.8 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ft� Load number (Btuh/ft? °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Co.[ Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Block Foam Fill R-9 0.143 n 4.79 2.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 4A5.2ovd 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 11 WII Block Foam Fill R-9 0.143 a 4.79 2.77 0 0 0 0 0 0 0 0 �--G 2 glazing, clr low-e 0.330 a 11.02 26.99 0 0 0 0 0 0 0 0 W Block Foam Fill R-9 0.143 s 4.79 2.77 0 0 0 0 0 0 0 0 glazing, clr low-e 0.330 s 11.02 11.21 0 0 0 0 0 0 0 0 L�2 2 glazing, clr low-e 0.330 s 11.02 19.08 0 0 0 0 0 0 0 0 11 DO 0.390 s 13.03 11.74 0 0 0 0 0 0 0 0 , Block Foam Fill R-9 0.143 w 4.79 2.77 0 0 0 0 0 0 0 0 �--G P 2 qlazinq, dr low-e Partition Wall 0.330 0.101 w - 11.02 3.38 26.99 1.17 0 95 0 95 0 321 0 112 0 30 0 30 0 102 0 35 11D0 0.390 n 13.03 11.74 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.07 1.72 20 20 21 34 206 206 220 353 F 22A-tpm 1.180 - 39.41 0.00 20 0 0 0 206 0 0 0 6 c) AED excursion -3 -36 Envelope loss/gain 343 143 321 352 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 1200 Subtotal (lines 6 to 13) 1343 143 321 1782 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -343 -143 261 109 14 Subtotal 0 0 582 1890 15 Duct loads 19% 43% 0 0 19% 43% 110 808 Total room load 0 0 693 2698 Air required (cfm) 0 0 8 114 Calculations aDDroved by ACCA to meet all reauirements of Manual J 8th Ed. _Q A 4-r wrightsoftm 2017-Jul-12 23:31:03 Right -Suite® Universal 2017 17.0.23 RSU23702 Page 4 ...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces: N ��Calcs Ri9 ht-J® Worksheet �?�e - Entire House ProCalcs, LLC Job: Rambo Date: July 13, 2017 By: Scott Pingleton P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Family Room Bath 2 2 Exposed wall 16.5 ft 5.5 ft 3 Room height 10.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 16.5 x 21.0 ft 346.5 ft2 1.0 x 64.8 ft 64.8 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft� Load number (Btuh/ft' °F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IW Block Foam Fill R-9 0.143 n 4.79 2.77 165 125 598 346 44 44 211 122 - 2 glazing, cir low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 -G 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 4A5-2ovd 0.330 n 11.02 9.08 40 0 443 365 0 0 0 0 11 W Block Foam Fill R-9 0.143 a 4.79 277 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 a 11.02 26.99 0 0 0 0 0 0 0 0 WI Block Foam Fill R-9 2 glazing, clr low-e 0.143 0.330 s s 4.79 11.02 277 11.21 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 s 11.02 19.08 0 0 0 0 0 0 0 0 D 11DO 0.390 s 13.03 11.74 0 0 0 0 0 0 0 0 W Block Foam Fill R-9 0.143 w 4.79 2.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 11.02 26.99 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 3.38 1.17 0 0 0 0 0 0 0 0 11DO 0.390 n 13.03 11.74 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 1.07 1.72 347 347 370 594 65 65 69 111 F 22A-tpm 1.180 39.41 0.00 347 17 650 0 65 6 217 0 6 c) AED excursion -62 -6 Envelope loss/gain 2061 1244 497 227 12 a) Infiltration 804 205 214 55 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 3 690 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13) 2865 3038 711 282 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 7 11 148 65 14 Subtotal 2872 3049 859 347 15 Duct loads 19% 43% 544 1303 19% 43% 163 148 Total room load 3416 4352 1021 496 Air required (cfm) 38 185 11 21 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. -F[:- wrightsoft, 2017-Jul-12 23:31:03 Right -Suite® Universal 2017 17.0.23 RSU23702 Page 5 ...ilders\Rambo\Working Drawings\Rambo Revised.rup Cale = MJ8 Front Door faces: N Calks Right-J 0 Worksheet Job: Rambo VZI w,,,w,-g Date: July 13, 2017 Entire House By: Scott Pingleton ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Clos 2 Bedroom 2 2 Exposed wall 2.5 ft 25.5 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 2.5 x 9.0 It 1.0 x 171.3 ft 5 Room area 22.5 ftz 171.3 ft2 Ty Construction number U-value (Btuh/ft? °F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Block Foam Fill R-9 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.330 0.330 n n n 4.79 11.02 11.02 2.77 9.08 9.08 20 0 0 20 0 0 96 0 0 55 0 0 104 16 0 89 0 0 424 171 0 246 141 0 11 W 4A5-2ovd Block Foam Fill R-9 0.330 0.143 n a 11.02 4.79 9.08 2.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 WI-ti 2 glazing, cir low-e Block Foam Fill R-9 2 glazing, clr low-e 0.330 0.143 0.330 a s s 11.02 4.79 11.02 26.99 2.77 11.21 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 l- 2 glazing, cir low-e 0.330 s 11.02 19.08 0 0 0 0 0 0 0 0 D 11DO 0.390 s 13.03 11.74 0 0 0 0 0 0 0 0 IW �--G P Block Foam Fill R-9 2 glazing, clr low-e Partition Wall 0.143 0.330 0.101 w w - 4.79 11.02 3.38 2.77 26.99 1.17 0 0 0 0 0 0 0 0 0 0 0 0 100 0 0 100 0 0 479 0 0 277 0 0 L-D 11 DO 16B-30ad 0.390 0.032 n - 13.03 1.07 11.74 1.72 0 23 0 23 0 24 0 39 0 171 0 171 0 183 0 294 C F 22A-tpm 1.180 - 39.41 0.00 23 3 99 0 171 26 1005 0 6 c) AED excursion -2 -24 Envelope loss/gain 218 92 2262 933 12 a) Infiltration 97 25 993 253 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1316 117 13255 1186 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -316 -117 186 79 14 Subtotal 0 0 3441 1265 15 Duct loads 19% 43% 0 0 19% 43% 652 541 Total room load 0 0 4092 1806 Air required (cfm) 0 0 46 77 Calculations aDDroved by ACCA to meet all reauirements of Manual J 8th Ed. -F+ wrightsoft- 2017-Jul-1223:31:03 .4 7-- Right -Suite@ Universal 2017 17.0.23 RSU23702 Page 6 C(Z...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces: N i �Calcs Right-J® Worksheet w°•°�°Na Entire House ProCalcs, LLC Job: Rambo Date: July 13, 2017 By: Scott Pingleton P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Bedroom 3 Laundry 2 Exposed wall 10.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 158.5 ft 6.5 x 9.0 ft 5 Room area 158.5 ft' 58.5 ft' Ty Construction U-value Or HTM Area M11 Load Area (ft� Load number (Btuh/ft? °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Block Foam Fill R-9 0.143 n 4.79 277 0 0 0 0 0 0 0 0 �-G 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 4A5-2ovd 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 11 W Block Foam Fill R-9 0.143 a 4.79 2.77 0 0 0 0 0 0 0 0 2 glazinq, cir low-e 0.330 a 11.02 26.99 0 0 0 0 0 0 0 0 W Block Foam Fill R-9 0.143 s 4.79 2.77 0 0 0 0 0 0 0 0 glazing, clr low-e 0.330 s 11.02 11.21 0 0 0 0 0 0 0 0 L�2 2 glazing, clr low-e 0.330 s 11.02 19.08 0 0 0 0 0 0 0 0 11D0 0.390 s 13.03 11.74 0 0 0 0 0 0 0 0 W. L-G Block Foam Fill R-9 2 glazinq, cir low-e 0.143 0.330 w w 4.79 11.02 2.77 26.99 80 16 65 0 309 171 179 418 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 3.38 1.17 124 124 420 146 52 32 108 37 11 DO 0.390 n 13.03 11.74 0 0 0 0 20 20 262 236 C 16B-3Oad 0.032 - 1.07 1.72 159 159 169 272 59 59 63 100 F 22A-tpm 1.180 - 39.41 0.00 159 10 394 0 59 0 0 0 6 c) AED excursion 190 -17 Envelope loss/gain 1463 1204 432 356 12 a) Infiltration 390 99 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 1852 1304 432 856 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 46 38 48 42 14 Subtotal 1898 1342 480 899 15 Duct loads 19% 43% 360 573 19% 43% 91 384 Total roam load 2257 1915 571 1283 Air required (cfm) 25 81 6 54 Calculations aDDroved by ACCA to meet all reauirements of Manual J 8th Ed _-:_- -I*`wrightsafft- 2017-Jul-12 23:31:03 Right -Suite® Universal 2017 17ACC;K.0.23 RSU23702 Page 7 ...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces: N l 1 Ri ht-M Worksheet Job: Rambo GCS Entire House Date: July 13, 2017 By: Scott Pingleton ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Lin 2 Hall 2 Exposed wall O ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 2.0 x 2.0 ft 9.5 x 4.0 ft 5 Room area 4.0 ft2 38.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number (Btuh/ftz°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Block Foam Fill R-9 0.143 n 4.79 2.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 4A5-2ovd 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 11 IW Block Foam Fill R-9 0.143 a 4.79 2.77 0 0 0 0 0 0 0 0 - L-G 2 glazinq, clr low-e 0.330 a 11.02 26.99 0 0 0 0 0 0 0 0 W Block Foam Fill R-9 0.143 s 4.79 277 0 0 0 0 0 0 0 0 glazing, clr low-e 0.330 s 11.02 11.21 0 0 0 0 0 0 0 0 L�2 2 glazing, clr low-e 0.330 s 11.02 19.08 0 0 0 0 0 0 0 0 11 DO 0.390 s 13.03 11.74 0 0 0 0 0 0 0 0 W Block Foam Fill R-9 0.143 w 4.79 2.77 0 0 0 0 0 0 0 0 2 glazinq, clr low-e 0.330 w 11.02 26.99 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 3.38 1.17 0 0 0 0 0 0 0 0 11 DO 0.390 n 13.03 11.74 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.07 1.72 4 4 4 7 38 38 41 65 F 22A-tpm 1.180 - 39.41 0.00 4 0 0 0 38 0 0 0 6 c) AED excursion 0 -1 Envelope loss/gain 4 7 41 64 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 4 7 41 64 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -4 -7 41 -64 14 Subtotal 0 0 0 0 151 uct loads 119% 431 0 0 19% 43% 0 0 Total room load 0 0 0 0 Air required (cfm) 0 0 0 0 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. -Fk wrightsoft` 2017-Jul-12 23:31:03 ACCP. Right -Suite® Universal 2017 17.0.23 RSU23702 Page 8 ...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces: N I � . � Ca�cs Right-JO Worksheet �•��° Entire House ProCalcs, LLC Job: Rambo Date: July 13, 2017 By: Scott Pingleton P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Clos Clos 3 2 Exposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 2.0 x 3.0 It 2.0 x 6.0 ft 5 Room area 6.0 ft2 12.0 ft2 Ty Construction U-value Or HTM Area (ftj Load Area (ft� Load number (Btuh/ft;°F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WI Block Foam Fill R-9 0.143 n 4.79 2.77 0 0 0 0 0 0 0 0 _ 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 i�CGI 4A5.2ovd 0.330 n 11.02 9.08 0 0 0 0 0 0 0 0 11 W Block Foam Fill R-9 0.143 a 4.79 2.77 0 0 0 0 0 0 0 0 2 glazinq, clr low-e 0.330 a 11.02 26.99 0 0 0 0 0 0 0 0 W Black Foam Fill R-9 0.143 s 4.79 Z77 0 0 0 0 0 0 0 0 glazing, cir low-e 0.330 s 11.02 11.21 0 0 0 0 0 0 0 0 L�2 2 glazing, clr low-e 0.330 s 11.02 19.08 0 0 0 0 0 0 0 0 11DO 0.390 s 13.03 11.74 0 0 0 0 0 0 0 0 W. Block Foam Fill R-9 0.143 w 4.79 2.77 0 0 0 0 0 0 0 0 2 glazinq, clr low-e 0.330 w 11.02 26.99 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 3.38 1.17 16 16 54 19 0 0 0 0 11 D0 0.390 n 13.03 11.74 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 1.07 1.72 6 6 6 10 12 12 13 21 F 22A-tpm 1.180 - 39.41 0.00 6 0 0 0 12 0 0 0 6 c) AED excursion -1 0 Envelope loss/gain 61 29 13 20 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 61 29 13 26 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -61 -29 -13 -20 14 Subtotal 0 0 0 0 15 Duct loads 19% 43% 0 0 19% 43% 0 0 Total room load 0 0 0 0 Air required (cfm) 0 0 0 0 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. -�- wrightsoft` Right -Suite@ Universal 2017 17.0.23 RSU23702 2017-Jul-12 23:31:03 ,qG� Page 9 ...ilders\Rambo\Working Drawings\Rambo Revised. rup Calc = MJ8 Front Door faces: N Duct System Summary Job: Rambo Date: July 13, 2017 TMC ICs 'Weave the missing piece Entire House By: Scott Pingleton ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 For: Rambo 2300 Canoe Creek Lane, Fort Pierce, FL 34981 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.60 in H2O 0.31 in H2O 0.29 in H2O 0.226 / 0.064 in H2O 0.105 in/100ft 310 cfm Cooling 0.60 in H2O 0.31 in H2O 0.29 in H2O 0.226 / 0.064 in H2O 0.105 in/100ft 933 cfm 276 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath c 496 11 21 0.140 4.0 Ox0 VIFx 21.5 140.0 st4 Bedroom 2 C 1806 46 77 0.163 6.0 Ox 0 VIFx 19.0 120.0 st4 Bedroom 3 C 1915 25 81 0.151 6.0 Ox 0 V[Fx 24.9 125.0 st4 Dining C 2761 46 117 0.120 7.0 Ox0 VIFx 43.4 145.0 st3 Family Room C 2176 19 92 0.133 6.0 0x0 VIFx 39.7 130.0 st5 Family Room -A C 2176 19 92 0.136 6.0 Ox0 VIFx 36.2 130.0 st5 Kitchen C 2698 8 114 0.121 7.0 Ox0 VIFx 41.2 145.0 st3 Laundry C 1283 6 54 0.150 4.0 Ox0 VIFx 25.3 125.0 st4 Living Room C 2496 44 106 0.110 7.0 0x0 VIFx 39.9 165.0 st3 Master Bath C 1631 27 69 0.108 6.0 Ox 0 VIFx 45.2 165.0 st3 Master suite -A C 2318 57 98 0.147 6.0 Ox 0 VIFx 34.2 120.0 st5 WIC c 243 1 10 0.105 4.0 Ox0 V[Fx 39.7 175.0 st3 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st3 Peak AVF 126 417 0.105 417 &0 12 x 12 RectFbg st2 st1 Peak AVF 310 933 0.105 395 5.3 17 x 20 RectFbg st2 Peak AVF 126 417 0.105 531 12.0 0 x 0 VinlFlx st1 st4 Peak AVF 89 233 0.140 668 8.0 0 x 0 VinlFlx st1 st5 Peak AVF 95 283 0.133 640 9.0 0 x 0 VinlFlx st1 Bold/italic values have been manually overridden Ak- wri htsoft' 2017-Jul-12 23:31:04 �� 9 Right -Suite® Universal 2017 17.0.23 RSU23702 Page 1 XCA _..ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces: N Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb5 Ox0 25 81 40.2 0.159 414 6.0 Ox 0 VIFx rt1 rb4 Ox0 46 77 54.5 0.117 390 6.0 Ox 0 VIFx rt1 rb2 Ox0 85 178 60.8 0.105 402 9.0 Ox 0 VIFx rt1 rb6 Ox0 154 597 47.5 0.135 428 16.0 Ox 0 VIFx rt1 Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 Peak AVF 310 933 0.105 320 9.7 21 x 20 RectFbg Bold/italic values have been manually overridden wri htsofte 2017-Jul-12 23:age 2 9 Right-Suite(g) Universal 2017 17.0.23 RSU23702 Page 2 ACCA ...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJS Front Door faces: N � 1 5 t Static Pressure and Friction Rate Job: Rambo Z»z u gca'CS Date: July 13, 2017 'We are the missingplece Entire House By: Scott Pingleton ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: PrbCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 For: Rambo 2300 Canoe Creek Lane, Fort Pierce, FL 34981 Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.60 0.60 Pressure losses Coil 0.07 0.07 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.15 0.15 Humidifier 0 0 Balancing damper 0.03 0.03 Other device 0 0 Available static pressure 0.29 0.29 Total Supply Return (ft) (ft) Measured length of run -out 8 25 Measured length of trunk 31 1 Equivalent length of fittings 175 35 Total length 215 61 Total effective length 276 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.105 OK 0.105 OK Return Ducts 0.105 OK 0.105 OK Fitting Equivalent LengthDetails Supply 4W=35, 2B1=30, 11G=5, 2B2=35, 9A2=5, 11G=5, 11G=5, 2B0=20, 1A=35: TotalEL=175 Return 60=10, 6C1=10, 11G=5, 5E1=10: TotalEL=35 wri htsoft® 2017-Jul-12 23:age 1 9 Right -Suite® Universal 2017 17.0.23 RSU23702 Page 1 'l-M ...ilders\Rambo\Working Drawings\Rambo Revised.rup Calc = MJ8 Front Door faces:' N