HomeMy WebLinkAboutProduct Approval - Metal Roofing7/19/2017 Florida Building Code Online
Business •Professional Regulation
BCIS Home I Log In I user Registration I Hot Topics Submit Surcharge I Stats & Facts I Publications I FBC Staff I SCIS Site Map I Links Search
bor
Product Approval
p USER: Public User
Ef�`.c��mVF.fwcm
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL11651-112
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived El
Product Manufacturer Gulf Coast Supply & Manufacturing, LLC.
Address/Phone/Email 4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352)498-7852
ray@gulfcoastsupply.com
Authorized Signature Ray Bowen
ray@gulfcoastsupply.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
R Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S. Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden
U Validation Checklist - Hardcopy Received
Certificate of Independence FL11651 R2 COI Cert of Ind Kuhn Eng.odf
FL11651 R2 COI Letter of Name change odf
Referenced Standard and Year (of Standard) Standard Year
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL 1897 2004
UL 580 2006
Equivalence of Product Standards
Certified By
https://floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsQFc5Kp/o2f rrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 1/5
7/19/2017 Florida Building Code Online ,
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page = 0
Method 1 Option D
07/01/2015
07/10/2015
07/18/2015
08/18/2015
0 0 Page l/ 20 0
FL #
Model, Number or Name
Description
11651.1
0.032" Aluminum 5V Crimp
0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 1 R2 0325vCrimp 15-
Approved for use outside HVHZ: Yes
32Plvwood NonHVHZ.pdf
Impact Resistant: N/A
FL11651 R2 II 14FL11651 1 R2 Metal Roof Panel Detail.ndf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.5PSF
Other: -108.5 psf @ 12" o.c. Install per manufacturers
Created by Independent Third Party: Yes
details. Not for use in HVHZ Zones.
Evaluation Reports
FL11651 R2 AE 14FL11651 1 R2 0325vCrimD 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
11651.2
0.032" Aluminum Gulf Lok
0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 2 R2 032GulfLok 16 IS -
32Plywood NonHVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detailpdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0
Created by Independent Third Party: Yes
psf @ 5 3/16" o.c. fastener spacing. Install per
Evaluation Reports
manufacturers details. Not for use in HVHZ Zones.
FL11651 R2 AE 14FL11651 2 R2 032GulfLok 16 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
11651.3
1" 24ga. Gulf Snap
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.Ddf
FL11651 R2 II 14FL11651 3 R2 1 24GulfSnaD 17 15-
Approved for use outside HVHZ: Yes
32Plvwood HVHZ..Ddf
Impact Resistant: N/A
Design Pressure: +N/A/--131.OPS
Verified By: Dan Kuhn, P.E. 75519
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c.
Created by Independent Third Party: Yes
clip spacing. Install per manufacturers details. For use in
Evaluation Reports
HVHZ Zones.
FL11651 R2 AE 14FL11651 3 R2 1 24GulfSnaD 17 1S-
32Plywood HVHZ..pdf
Created by Independent Third Party: Yes
11651.4
1" 24ga. VersaLoc
1" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 4 R2 24VersaLoc SR 16.5 15-
32131vwood HVHZ..Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 4 R2 Metal Roof Panel Detail..pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-138.5PSF
Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c.
Created by Independent Third Party: Yes
clip spacing. Install per manufacturers details. For use in
Evaluation Reports
HVHZ Zones.
FL11651 R2 AE 14FL11651 4 R2 24Versal-oc SR 16.5 15-
32Plywood HVHZ..pdf
Created by Independent Third Party: Yes
11651.5
1" VersaLoc .032" Aluminum
1" VersaLoc .032" Aluminum over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 5 R2 lin 032VersaLoc SR 16 15-
32Plvwood HVHZ..Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 5 R2 Metal Roof Panel Detail..Ddf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-IOI.OPSF
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6"
Created by Independent Third Party: Yes
o.c. clip spacing. Install per manufacturers details. For use
Evaluation Reports
in HVHZ Zones.
FL11651 R2 AE 14FL11651 5 R2 lin 032VersaLoc SR 16 15-
https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2ffrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 2/5
7/19/2017
Florida Building Code Online
32Plywood HVHZ..r)
Created by Independen Third Party: Yes
11651.6 11.5" 24ga. Gulf Snap
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.OPSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install
per manufacturers detals. For use in HVHZ Zones.
11651.7 1 1.5" 24ga. VersaLoc
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @
12" o.c. clip spacing. Install per manufacturers details. For
use in HVHZ Zones.
11651.8 12" 24ga. MegaLoc
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for
use in HVHZ Zones.
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 6 R2 1.5 24GulfSnap 16 15-
32Plywood HVHZ..Pdf
FL11651 R2 II 14FL11651 6 R2 Metal Roof Panel Detail..odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 6 R2 1.5 24Gulf5nap 16 15-
32Plywood HVHZ..pdf
Created by Independent Third Party: Yes
1.5" VersaLoc 24ga. 16" wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 7 R2 1.5 24VersaLoc 16 15-
32Plywood HVHZ..pdf
FL11651 R2 II 14FL11651 7 R2 Metal Roof Panel Detail..pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 7 R2 1.5 24VersaLoc 16 15-
32Plvwood HVHZ..pdf
Created by Independent Third Party: Yes
24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 8 R2 24MeoaLoc 18 15-
32Plywood NonHVHZ.pdf
FL11651 R2 II 14FL11651 8 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 8 R2 24MeoaLoc 18 15-
32Plywood NonHVHZ.odf
Created by Independent Third Party: Yes
111651.9 124 Ga. Gulf Lok 124 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install
per manufacturers details. Not for use in HVHZ Zones.
11651.10 124 Ga. Gulf Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure. +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
11651.11 124 Ga. Gulf Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @
12" o.c. clip spacing. Install per manufacturers details. Not
for use in HVHZ Zones.
Installation Instructions
FL11651 R2 II 14FL11651 9 R2 24GulfLok 16 15-
32Plvwood NonHVHZ.pdf
FL11651 R2 II 14FL11651 9 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 9 R2 24GulfLok 16 15-
32Plywood NonHVHZ.odf
Created by Independent Third Party: Yes
24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins
over 15/32" Plywood
Installation Instructions
FL116SI R2 II 14FLI1651 10 R2 24GulfSeam 16 1x4 15-
32Plvwood NonHVHZ.pdf
FL11651 R2 II 14FL11651 10 R2 Metal Roof Panel Detail.ndf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 10 R2 24GulfSeam 16 1x4 IS-
32Pywood NonHVHZ.pdf
Created by Independent Third Party: Yes
24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over
15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 11 R2 24GulfSeam 18 15-
32Plvwood NonHVHZ.pdf
FL11651 R2 II 14FL11651 11 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 11 R2 24GulfSeam 18 15-
32Piywood NonHVHZ.Ddf
Created by Independent Third Party: Yes
hftps://floridabuilding.org/prlpr app dtl.aspx?paramwuGEVXQwtDgsQFc5K%2f rrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 3/5
7/19/2017
Florida Building Code Online
11651.12 1 26 a_ U Crimp
26 Ga. 5V Crimp Roo., 'I over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
@ 6" ox. fastener spacing. Install per manufacturers
details. For use In HVHZ Zones.
Installation Instructions
FL11651 R2 II 14FL11651 12 R2 265vCrimp 15-
32Plywood HVHZ.pdf
FL11651 R2 II 14FL11651 12 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 12 R2 265vCrimp 15-
32Plvwood HVHZ.pdf
Created by Independent Third Party: Yes
111651.13 126 Ga. 5V Crimp 126 Ga. 5V Crimp over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf
@ 16" o.c. fastener pattern. Install per manufacturers
details. Not for use in HVHZ Zones.
11651.14 126 Ga. 5V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
@ 6" o.c. fastener spacing. Install per manufacturers
details. For use in HVHZ Zones.
11651.15 126 Ga. Gulf Lok
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161.OPSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener
spacing. Install per manufacturers details. For use in HVHZ
Zones.
Installation Instructions
FL11651 R2 II 14FL11651 13 R2 265vCrimp 15-
32Plvwood NonHVHZ.adf
FL11651 R2 II 14FL11651 13 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 13 R2 265vCrimp 15-
32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32"
Plywood
Installation Instructions
FL11651 R2 II 14FL11651 14 R2 265vCrimp 1x4 15-
32Plvwood NonHVHZ.odf
FL11651 R2 II 14FL11651 14 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 14 R2 265vCrimp 1x4 15-
32Plywood NonHVHZ.ndf
Created by Independent Third Party: Yes
26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 15 R2 26GulfLok 16 15-
32Pivwood HVHZ.pdf
FL11651 R2 II 14FL11651 15 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 15 R2 26GulfLok 16 15-
32Pivwood HVHZ.odf
Created by Independent Third Party: Yes
111651.16 126 Ga. Gulf Lok 126 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-63.5PSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
spacing. Install per manufacturers details. Not for use in
HVHZ Zones.
Installation Instructions
FL11651 R2 II 14FL11651 16 R2 26GulfLok 16 15-
32Plywood NonHVHZ.odf
FL11651 R2 II 14FL11651 16 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 16 R2 26GulfLok 16 15-
32Plvwood NonHVHZ.pdf
Created by Independent Third Party: Yes
111651.17 126 Ga. GuIfPBR 126 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-154.7PSF
Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf
@ 12" o.c. fastener pattern. Install per manufacturer
details. Not for use In HVHZ
11651.18 126 Ga. GuIfPBR
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Installation Instructions
FL11651 R2 II 17 R2 26GulfPBR 15-32Plvwood NonHVHZ.pdf
FL11651 R2 II 17 R2 Metal Roof Panel Detail.ndf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 17 R2 26GuIfPBR 15-
32Plvwood NonHVHZ.pdf
Created by Independent Third Party: Yes
26 Ga. GuIfPBR Roof Panel over 1x4 Wood Purlins over 15/32"
Plywood
Installation Instructions
FL11651 R2 II 14FL11651 18 R2 26GulfPBR 1x4 15-
32Plvwood HVHZ.Ddf
https://floridabuilding.org/prlpr ppp_dtl.aspx?param=wGEVXQwtDgsQFc5K%2ffrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 4/5
7/19/2017 - Florida Building Code Online ,
Impact Resistant: N/A
Design Pressure: +N/A/-151.7PSF
FL11651 R2 II 18 R, Vital Roof Panel Detail.Ddf
Verified By: Dan Kuhn, P.E: 75519
Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf
Created by Independent Third Party: Yes
@ 12" fastener spacing. Install per manufacturer's details.
Evaluation Reports
For use in HVHZ Zones
FL11651 R2 AE 14FL11651 18 R2 26GulfPBR 1x4 15-
32Plvwood HVHZ.pdf
Created by Independent Third Party: Yes
11651.19
26 Ga. GulfPBR
26 Ga. GulfPBR over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 19 R2 26GulfPBR 15-
Approved for use outside HVHZ: Yes
32Plvwood HVHZ.odf
Impact Resistant: N/A
FL11651 R2 II 19 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf
Created by Independent Third Party: Yes
@ 12" D.C. fastener spacing. Install per manufacturer's
Evaluation Reports
details. For use in HVHZ Zones.
FL11651 R2 AE 14FL11651 19 R2 26Gu1fPBR 15-
32Plvwood HVHZ.pdf
Created by Independent Third Party: Yes
11651.20
26 Ga. GulfPBR
26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 20 R2 26Gu1fPBR 1x4 IS -
Approved for use outside HVHZ: Yes
32Plvwood NonHVHZ.pdf
Impact Resistant: N/A
FL11651 R2 II 20 R2 Metal Roof Panel Detail.ndf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Other: -94.25 psf @ 24" D.C. fastener spacing.-151.75 psf
Created by Independent Third Party: Yes
@ 12" fastener spacing. Install per manufacturer's details.
Evaluation Reports
Not for use in HVHZ Zones
FL11651 R2 AE 20 R2 26GulfPBR 1x4 15-
32Plvwood NonHVHZ.Ddf
Created by Independent Third Party: Yes
Go to Page [j o
Back Plext
0 (a Pagel/20 0
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S.,
please click here.
Product Approval Accepts:
®® 99 M
Credit Card
Safe
https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFo5Kg/g2frrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d°/`3d 5/5