Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Gas Pipping Schematic
ft BOARD OF COUNTY COMMISSIONERS GAS PIPING SCHEMATIC [A41 [L4 TANK 1.1 1.31 NSI JL7]I EL91 EL11 SIZE [All TANK SIZE: Z0 GALS. APPLICANCE - TYPEISIZE PIPING LENGTH & SIZE L1 nQ FT. L2 FT. L3 A FT. L4 FT. L5 FT. L6 FT. L7 FT. L8 FT. L9 FT. L10 FT. L11 FT. L12 FT. Revised 7/22/14 PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division ,�Or -5�, "d ST. LUCIE COUNTY BUILDING DIVISION REVIEW FOR cor�IP cE REVIEWED �Y DATE MAN A _ I, 14 IT MUDS DS KRPT ON JOQ OR NO INSPECTION WILL_ BE MAbIg I BTU Z- to 06 BTU MTCOD BTU BTU BTU BTU (PIPE SIZE WAS TAKEN FROM 3h INCH DIA. OTHE 2010 FBC F ELL_G'AS CODE- 1 INCH DIA. TABLE 402 E�' INCH DIA. INCH DIA. INCH DIA. INCH DIA. INCH DIA. INCH DIA. FILE COPY INCH DIA. INCH DIA. INCH DIA. "INCH DIA. Website: www.stlucisca.dov 2300 Virginia Avenue - Fart Pierce, FL. 34882-5652 Phone (772) 462-1553 FAX (772) 462-1576 22'-V 22'-0' . B I O D7 0 ___._ _ O _.____-_____________ I„I 1 Or--- m 1D'-V CL& _____ — — — — r�'aa-- -- --� � t 20'-4' COVERED LANAI 5 m' K m I IB B, c CONCRETE PAVERS m . s = s _ i 1 MASTER I j 1 i BEDROOM j 1 i CASUAL 9" DINING m 1 1 I I 1 I I--- ________________J I L------------------- J a• I FI CEILIm. n'-B•�LelG---------� I I I I � � I S'-21R• 8'-S I!1' 5'-II• - v I I I I 3C.OIINTGER _zzI TOP �I o n• ° n� MASTER 0 BATH 4' a a j I� ' II I 12 I Ij I A _ ElA FA2M2'-I0L'Y I I I— lII ROOM II , a IGLASS lu I - 'a t 16• sm. sr 4- I0'-B' CLG. 10, CLASS WALL WAT W CAT, 11V sAFETT C.L. CAT11 s - R E s r �(ool m ENCLO. 4.m 5 4• 4' i' I I B' I I 1 i I I I I I I I. I j 1 ii 1 I I I I I I I L J I 4' I— v 10 la I 4 -W 1 o 1p I 9 4 _ E ,� C m s , - rR. B41 4' •' Y n 1 I _ B'-b 12 'B HALL`.. 0.G a' PARTITION UNDER KITCHEN PA 7m•-s' . 9'-1• 6'-3' %I' -II' IB'-2' I'-II'I � COUNTER 6m'-B' OLG. 14'-S' CL.Ca. s W.I.C. a r, �. - m I K _ v Oi 4. 4' .. •: Lxi _ —__ _________________J _____________ 31Q'X3 V1'T9 MICRO DBL TOILER -,p _ % I� e m _ � __ _ _ BOiT01'1 GF 80FFIT � I0'-B' g• a< 9 v 0 0 0 __ 3'-B—' '_2i 3'-B— •_21— 3'-S— '-7r 3'-S— '-2 I 4'-0' n'-a• i . 0 _ m m w fi HA BEDROOM mr s 2 � 9 BATH 2 '" I0'-B•CLG. Q ® 55-g• q. 2' 2'-II' 8' 3'-2' av ° 6,_B, 2' 4 41 "O' " 1 ° L12. _J L___ a 6' � DEN 9 113 _m i s. " 4• ® i __ 3•_0• I :T v R 4 SH n _3 LAUNCH • I0'-0' CLG. `T m FR. FR. -II GATT NO1E INSULATION FIRE ION SEPARAMAINTAITION \ li'1x3A—1 SEPARATION 1AIAC•GE55J MONOxl�� BOL RFILTRATION AT I -II GATT A/C CLOSET. 9 INSULATION - I I TOP OTEP FROM r THRESHOLD s GARAGE 1 9 Im'-B' CLG. — I ; ^I O O �coND.1 m WD 6'-B' 0 -B' CL •-m• I13 4. 1 --L-- 1 m' FOYER O'�C(a. 1 4, I - ---J-- py� (SEE RALJ MTL. STUD °euILR our FROM CLG. TO 30' AFF. U. w W.I.C. �� 4• BI RASH ® BEDROOM in c,at n 10'-B' CLG. SHOu R OH °,Ad I _ ______ i0 �� _ h R4SH 0, v I — W.I.C. 11 m'"s' 11 u.G. B 5 -B B' 5 e v - 0 COV. ENTRY s n-a cLGcLG. __—___ � _ — - ENCLO. ------- m r ' BATH #3 9' m' LAP SIDING PATIO :D II'-4• 1-2' I ® 0 ® H a 0 of _q. 4' a ® __________ ________ 0 _ Efi mes z IZONTAL LAP 81DWCa HORIZONTAL LAP SIDING 8'-9' 8'-9' 2'-S• IS'-0' 2'-6' '-4 B'_0• '-4 n'-6• 4-1 FLOOR FLOOR PLAN ELEVATION "D" SCALE: 1/4' • I'-0' a 10.8 LOT 37 VACAM lmbmttiLk --v S89'57'WW MR.) 2562W 8 441- Z 0Val 4 2 S7gp,� D IT GV. t � h //9.67 v4b WATERUGHT POLE g. g POIE HEIEC c / . P.R.C. / / BENCH MARK LOT 34 'RHIERBO , ACCOR PCPMAIL PLAT BOOK 67, PAGES 36 TI / �'•S ELEV.=8.80 LUCIE COUNTY, FLORIDA. .1b/gyp' ey1 C�, SAID LANDS 51TUATE RF ST. I b � CONTAINING 27,052 SQUARE SUBXCT TO EASEMENTS, RV RIGHTS -OF -WAY OF RECORD. >DilAlLtfmAir / I HEREBY CERTIFY THAT THE , / DESCRIBED PROPERTY IS TRUE BEUEF AS SURVEYED UNDER 1 CERTIFY THAT THIS BOUNDARI FORTH IN CHAPTER W-17 AD SURVEYORS AND MAPPERS, PI 19-Jul-17 Confined Space/Combustion Air Calculation Address 13306 NW Baycliffe PI Lot 38 Total Room Appliance Btu's Required Required Rooms Rooms sizes in Air Avail Air Calc Air in calc Dimmension Calc Cf vol Cooktop 100,000 100,000/1000 x50 Water Heater 75,000 75,000/1000 x50 5000 Kitchen/ dining 35' x 20' x10' 7000 No Makeup Air Required for Cooktop 3750 garage 30' x 20' x 10' 6000 No Makeup Air Required for Water Heater Table P-1 Propane Low Pressure (Standard) Maximum . Capadity of Orr 0' -Flex TracPipeT"' in Thousands of 'BTU per Hour Propane Gas noc PrPcciirP- 11 in_ W.C. Pressure Drop: 0.5 in. W.C: (based on a 1.52 Specific Gravity Gas) 15 19 99 211 69 150 56"1 121 49 106 42. - 1 39 94 . 87 209 191 379 344, 583 528 1254 1143 .2940 2684 33 74 166 297 449 988 2327 3l1 LO 66 60 149 136 265 241 397; 359 884' 805 2082 1�02 ca 57 126 222 330 745 : 1761 GJ 52 118 208 3p7 896 `1647 �� 50 112 197 286 656 1554 '-" 47 106 186 270 621 1475 36 87 143 217 506 1205 33 76 129 183 438 1045.1.,934 30 26 68 62 117 107 163 147_. 30 357 854 25 31 37 456 893 325 605 267 490 232. 425;.,, 1424 971 775. 661 46 2830 1993 1623 1404 62„ ;" 65"468P,3791 3285.. see notes below* This number is used to compare Individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping. EHD (Effective Hydraulic -Diameter) A relative measure of Low capacity; Table P-2 Propane Medium Pressure Maximum Cappcit/ of ®mega Flax Trae fte in Thousands of BTU per Ho*e Propane Gas Gas Pressure: 1/2 psi (.12-14 in. W. C.) Pressure Drop: 2.&in. W. C. (based on a 1.52 Specific Gravity Gas) 222 159 62 58 55 52 43` 37 3 30 _ I 19 ` 491 393.: 290` 2 22$ 209 1$ 164 .., 150 140 1. 31 124 .11$.. ° 97, 85 . 76 70 642 32$ 304 2$5,69 -56 10' 183 .. 164 136 1©94 782 1863 1720 1343 1106 976: ,<$d3, .: 825 771" 719 .673. 632 596 �}°70 39$� 352 320 31 -512 , 748 70Q 661. 5 8 449 397 359 37 3476 2368. 1891 1612 - 1424 1288 . 10 9 971 . 877. 8Q5 .. , . , 988 884 8.Q5 ^; 46 6383 4.496 3663 316$ 6 28`30 ; 2580 22 Q. 1-90 1$18 1682, . 157,1, 1481 140_,.4 1143 - . 62.:.. 1458 ._ 1033-, 8448: 7317 `6547 ,5980 5183 ,4sa8: 42$6 $3.. 3671 3462 1,:3285 2684 2327 ?d02 .1902 two.ef d flttinge Ilubtng runs W#h larger numbflrs of bends andior-tittingsshell be increased by=an equivalent length of tubing to the following NOTES: Tables above`.include losses for four go -degree bends and Is the number of additional fitting9,6 hd/or'benda _ eq ttlon:1�1.3n where L Is addltiortal length of {ubing and n '