Loading...
HomeMy WebLinkAboutGeneral Specificationsauar.Rirs>rEet Quality Steel Corporation AG/UG Propane Tanks LEG WIDTH 1450 wg. AND UP APPROXIMATE ABOVEGROUND/UNDEGROUND 1AG/UG1 VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT LEG* WIDTH LEG** SPACING WEIGHT (Ibs.) **QUANTITY FULL LOAD PER STACK *120 wg. 24" Ellip. 5'-8" 3' 1'-1 1/2" 2'-10 1/2" 260 108 196 16112 *250 wg. 30" Hemi. 7'-10" 3'-8" 1'-5" 1 4'-11" 480 54 9 *320 wg. 1 30" Hemi. 9'-7" 3'-8" 1'-5" 5' 620 45 9 500 wg. 1 37 1/2" Hemi. 10, 4'-2" 1'-8" 5' 950 37 130 8 1 6 1000 wg. 41" Hemi. 16' 4'-5" 1'-8" 11'-9 1/2" 1,800 17 1 15 6 15 1450 wg. 461/2" Ellip. 17'-4" 4'-11" 1'-9" 11'-7" 1 2,650 1 12 4 1990 wg. 461/2" Ellip. 23'-11" 4'-11" 1'-9" 16' 1 3,520 1 8 1 4 Dimensions and specifications shown are approximate. Individual vessels may vary. * Leg spacing+/- 2". Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120, 250, 320 wg. standard tanks - no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes 16" on center. 1450 wg. and up as shown above. ** Full load and stack quantities vary by shipping location. Check with your salesperson for details. General Specifications - Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vill, Division 1. Complies with NFPA 58. - Rated at 250 psig from -20' F to 125' F. All vessels registered with National Board. - Two service options available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane topcoat, supplied with steel AG/UG dome. - All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated January 14, 2015 PROPANE CONSTRUCTION NOTES 1. All pipe and fittings above ground and inside building shall be SCH. 40 Galvanized ASTM A120 or AGA approved. corrugated stainless steel (C.S.S.T.) pipe. 2. All polypipe and fittings shall be ASTM D2513 or ASTM D2517 and shall be buried outside underground at a depth of 18" with warning tape and tracer wire. 3. All pipe and meter locations are approximate and subject to change. 4: All- polypipe shall be joined by heat fusion or approved mechanical couplings. , 5. All 'g.alvanized pipe shall be threaded. 6. All pipe shall be pressure.tested to 20 # PSI for a 24 period of hours. SO WIL I Ell Tl Z72"� o PL a —.�• �fa�f�.—if f ' sir 1-9 �. • I UNDERGROUND TANK INSTALLATIOR 2" 6o G' DOWNGRADED AWAY ' • FROM DOME '=y •MIN. e"'tt ,i • �' t ANODE CABLE SACRIFICIAL ANODE ��� %?` • • . • •� . • (MAGNESIUM BAG) • + ,• • vs 4 • *�� q%'n!' I REGULATOR rA1, .. SHUT GAS OFF AT • OUTSIDE YALYE IR ABOVE ADE ..... RISER 0 i • WARY IlG TAPE • � Y . •.. • _ . ' RrsER� GRADE/CONCRETE 1 . SLEEVE • Nt as UHOEAGnOU110 V,0AS COHUUHEn SERVICE LINE jF;l ' TRACE HIRE 1