Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeRECEIVED OCT o J 2017 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance -Method AW Lt Project Name: eAdcl RESIDENcE, 'Builder Name., AMIQK1% Street, 114'QUEEN'BESS COURT . State; ', Permit Office: ST.LUCI9'A4fY dOl City, Zip: FT. P IERCE, FL,. Permit Number. L Owner. !0, BACI Jurisdiction: - Design Location: FL, Fort Pierce 'County:: ST. LUCIE COUNTY (Florida Climate Zone 2 1. Ndw construction or existing Now (From Plans) 9., Wall .Types (2 1 051.D scift.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- EA'Insul, Exterior R=4.1 1811.00 ft2 3. Number of units, if m . ultiplefamily b. Frame - Wood, Adjacent c. N/A R=1 1.0 240.00 ft2 R= ft2 4. Number of Bedrooms 3 d. NIA R-- ft2 5. Is this a worst case? No' 10. Ceiling -Types (1964.0 sqft.) insulation Area a: Under Attid (Vented) R--30.'0 1964.00A2 6. CPnd.itIoned'f1oor-aTe6 above grade (fvj 1664 b. N/A R= fti 'Conditioned floorafea below grade(w), 0 c. N/A R= ft2 7. Windows(258.7 sqft.) Description Area 11. Ducts a. Sup: Attie, Ret: Attic, AH, Gara g a F2 ft2 6 '425 a. LI-F66tor. Db(,,U=0:45� 158:67V SHGC, SHG0-0,25 b. U-Factor: N/A ft2 12. Cooling systems kBtuihr Efficiency SHGC: a. Central Unit 41.0 , SEER:16:00 c. U-Factor: N/A ft2 SHGC: '13. Heating systems kBtulhr Efficiency d. U-Factor:. N/A ft2 a; Electric Strip Heat. 34.0 COPA.00 SHGC: Area Weighted Average'Overhang Depth: t . h: 16.223 -ft. Area Weighted Average -SHGC: 0.250. 14. Hot water systems 8. Floor Types (1963.0 sqft.) InsulationArea a. Electric' Cap; 50 gallons' a. Slab-Onm'Grade Edge Insulation R=0.0 1963.00 ft2 b. Consdrvdtion features EF: 0.970 b. N/A R= ft2 None: c. N/A R= f12 15..Credits CF, Pstat Total Proposed Modifl6d Glass/Floor Area: OJ.& Loads: 67.68 PASS Total Baseline Loads: 69.64 I hereby certify that the, plan& and specifications covered. by . Review of the plans and -TIOES A A E"" ihis,calculation are In, compliance with the Florida Efioirgy spediflcati6ns.6oVefed by this Code calculation Indicates compliance PIE D PV. with the Florida Energy Code. PREPA 'C - Before construction is completed DATE this building will be Inspected for compliance with Section, 553.908' I hereby certify that this building,, as designed; is incompliance; Florida, Staiutes. with the FlotidaEhdrgy-cbde. WE OWNER/AGENT: BUILDING OFFICIAL: DATE: p DATE: - compliance requires' c6irtification by'the-41ir handler unit.manufacturer that the Air handler enclosure qualifies as certified factory -sealed inaccordafte with- R403.9.2.11. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance -with R462.4.1.1 and an envelope leakage test report In accordance With R402.4.1.2.. 9/1/2017-9:06 AM EnerjyGaugeg USA - FlaRes20'1 4 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT' Title: BACCI RESIDENCE Bedrooms: 3. Address Type: Street Address Building Type:. 'User Conditioned`Area: 1964 Lot # Owner: -BACCI Total Stories: 1 Block/SubDlvislon: # of Units: 1 Worst Case: No PlatBook: Builder Name: AMERON HOMES Rotate Angler 0 Street: 114 QUEEN BESS CO Permit Office: ST. LUCIE'COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing:; New (From Plans). Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design. Location 'TMY"Site Zone 97.5 % 2.5 0% Winter Summer Degree -Days Moisture Range FL, Fort Pierce FL VI-RO_BEACH_MUN1 2 39 90 70 75 .299 '62 Low BLOCKS Number Name Area Volume, 1 Entlib House 1964. 20241 SPACES' Number Name Area Volume Kitchen. Occupants, Bedrooms InfilID Finished Cooled Heated 1 MASTER'BEDROO 240 .2880' No 2 1 1 Yes Yes Yes 2 WIC 41 328 No 0 1 Yes Yes Yes 3 M.BATH 163 1.304 No 0 1 Yes Yes Yes 4 WIC "2 29 '232 No 0 1 No Yes Yes 5 FAMILY 305 3660: No 2 1 Yes- Yes Yes 6 FOYER 73. .657 No 0 1 Yes Yes Yes 7 DINING 192 .2304 No 0 1 Yes.. Yes Yes 8 KITCHEN 232 2784 Yes 0 1 Yes Yes Yes 9 NOOK 145 1740 No 0 1 Yes Yes Yes 10 BATH 2 71 568 No 0 1 Yes Yes Yes 11 BEDROOM'3 165 1240 No 1 1 1 Yes Yes Yes 12 BEDROOM'2 144 '1152 No 1 1 1 Yes Yes Yes 13 UTILITY 80 640 No 0 1 No Yes Yes 14 Room14 94 752 No 0 1 No Yes Yes FLOORS #. Floor -Type.' Space 'Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO ''31 ft 0 240 f12 0 1 0 2 Slab.'On-Grade Edge Insulatio WIC 7.ft 0 41• ft2 ____ 0 1 0 3'Slab-On-Grade Edge, Insulatio, M..BATH 31 ft ,0 162.5 ft2 0 1 0 48Iab-On=Gr9de.Edge Insulatio 'WIC 2 1 ft 0 28.5 ft2 ___ 0 1 0 911/2017 91:05 AM EnergyGaug6 USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter'Perimeter-R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge: Insulatio FAMILY 15 ft 0 305 W __- 0 1 0 6 Slab -On -Grade Edge Insulatio FOYER 9 ft 0 73 ft2 0 1 0 7 Slab -On -Grade Edge•Insulatio DINING12 ft 0 192 ft2 ____ 0 1 0 8 Slab-On-Grade.Edge Insulatio KITCHEN, 5 ft 0 232 ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulatio NOOK 24.4 ft 0 145 ft2 ___ 0 1 0 1051ab-On-Grade Edge Insulatio BATH 2 8 ft 0 71 ftz ___ 0 1 0 11SIab-On-Grade Edge Insulatio BEDROOM 3' 26 ft, 0 155 f12 ____ 0 1 0 12SIab-On-Grade.Edge Insulatio BEDROOM 2> 13 ft 0 144 ftz' ___ 0 1 0 1381ab-On-Grade Edge Insulatio UTILITY 1 ft 0 80 fta 0 1 0 14SIab-On4radeEdge Insulatio Room14 1 ft 0 94 ftz _ 0 1 0 ROOF j Roof Gable Roof Solar SA Emitt Emitt' beck Pitch V # Type Materials Area Area, Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles, ;2070 ft? 0 ft2 'Medium 0.6 No 0.9 No 0 18.4 ATTIC. V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1964 ft2 N N. CEILING It. Ceiling Type Space 'R-Value Ins Type Area Framing Frac. Truss Type 1 Under Attic (Vented) MfASTER'BEDRO '30 Blown 240ft2 0A Wood 2 Under Attic, (Vented) WIC 30 Blown 41 ft2• .0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 163 W 0.1 - Wood 4 Under Attic (Vented) WIC 2 30 Blown 29 ft2 0.1 Wood 5 Under Attic (Vented) FAMILY 30 Blown 305 ft? 0.1 Wood 6 Under Attic (Vented) FOYER 30 Blown 73 W 0.1 Wood 7 Under Attic; (Vented) DINING 30 Blown 192 ft2 0.1 Wood 8 Under Attic (Vented). KITCHEN 30 Blown 232 ft2 0.1 Wood 9 Under Attic (Vented) NOOK 30 Blown 14.5 ft2 0.1 Wood 10 'Under Attic (Vented) BATH 2 30 Blown 71 ft2 0.1 Wood 11 Under Attic (Vented) BEDROOM-3 30 Blown 155 ftz 0.1 Wood 12 Under Attic (Vented) BEDROOM 2, 30 Blown 144 ft2 0.1 Wood 13 Under Attic (Vented) UTILITY 30 Blown 80 ft2i 0.1 Wood 14 Under Attic (Vented) Room14 30 Blown 94 ft2. 0.1 Wood 911/2017-9.05AM Energ'yGauge® USA - FlaRes2014-Section R405.4.1 'Compliant Software 'Page 3 of 6 FORM R405-2014 WALLS Adjacent SOrnt Cavity Width Height Sheathing FramingJe Solar Below Topace RX81-3 Et In Et In Acen RAW, Fraction or 1 E Exterior Concrete Block -:Ext InAIASTER-BE 4.1 18 0 12, 0 2A6.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Ext Ins1AASTER.BE. 4.1 13 0 12 0 156.0 ft2 0 0 0.6 0 3 E Exterior Concrete Block - Ext Insul WIC 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 _ 4 N Exterior Concrete Block-,Ext.InsuM. BATH 4A . 19 0 8 0 152.0 ft2 0 0 0.6 0 5 E Exterior, Concrete.Block-- Ext InsuM.'BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 6 W Exterior Concrete Block - Ext InSUM. BATH 4.1 5 0 8 0 40.0 W 0 0 0.6 0 _ 7 S Exterior Concrete Block - Ext Insul FAMILY 4.1 15 0 12 0 180.0 ft2 0 0 0.6 0 8 N Exterior Concrete Block - Ext Insul FOYER 4.1 9 0 9 0 81.0 ft2 0 '0 0.6 0 - 9 N Exterior Concrete Block - Ext Insul DINING 4.1 12 0 12 0 144.0 ft2 0 0 0.6 0 16 SE Exterior Concrete. Block-'Ext,lnSUKITCHEN 4.1 5 0 12 0 60.0 ft2 . 0 0 0.6 0 _ 11 E Exterior Concrete Block-•ExtAnsul. NOOK 4.1 11 0 12 0. 132A ft2 0 0 0.6 0 12 SE, Exterior Concrete Block- Ext Insul NOOK 4.1 4 3 12 0 51.0 ft2 0 0 0.6 0 _ 13 S Exterior Concrete Block - Ext Insul .NOOK 4.1 5 0 12 0 60.0 ft2 0 0 0.6 0 14 SW Exterior ConcreteBlock-.Ext.Insui NOOK 4.1 4 3 12 0 51.0'ft2 0 0' 0.6 0 ,_ 15 E Exterior Concrete Block-.Ext1nsul BATH 2 4.1 1 0 8 6 8.0 ft2 0 0 0.6 0 _ 16 S Exterlor Concrete Block - E_ct.lnsul•BATH 2 4.1 6 0 8 .0 46.0 ft2' 0 0 0:6 0 _ 17 W :Exterior Concrete Block.- Ext:IhsuIBATH 2• 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 _ 18 S Exterior Concrete Block - ExtlnfffDR00M 3 4.1 13 0 8 0 104.0 #t2 0 0 0.6 0 . 19 W Exterior Concrete Block - Ext'IngEOROOM-'3 4.1 13 0 8 0 104,0 ft2 0 0 0.6 0 _ 20 W Exterior Concrete:Block,= Ext'1nd3EDR0OM 2 S.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _21 N -Garage Frame- Wood WIC 11' 30 8, 240,0'ft2 0.23 0.6 0 DOORS 0 Ornt Door Type' -Space Storms U-Value. Width Height, Area Ft In Ft In 1 N Insulated FOYER; None 39 6 6 8 40 ft2 WINDOWS. Orientation shown is the entered, Proposed orientation. Wall. Overhang V # . Ornt ID - Frame _ Panes . NFRC U-Factor SHGC .,Area Depth Separation Int Shade Screening 1 E • 1 Vinyl Low-E Double Yes 0.45 0.25 ' 9.0 ft2 1 ft4 in' 1 ft 4 in None None 2 S 2 Vinyl Low-E Double Yes 0.45 0.25 41.0 ft2 14 ft 21n '1 ft41n None None • 3 N 4 Vinyl Low-E Double Yes 0.45 0.26 9.0 ft2 i ft 4 in 1 ft 4'in None None 4 E 5 Vinyl Low-E Double Yes 0.45 0.25' 6.0 ft2, 1 ft 4-in 1 ft 4 in None None 5 S 7 Vinyl Low-5 Double Yes, 0.45 0.25 61.5 ft2 14 ft 2 in 1 ft4:in None None 6 N 81 'Vinyl Low=E Double Yes 0.45 6.25 :9.5 ft2 9 ft 0 in 1 ft 4,in None None 7 N 9 Vinyl: Low-E Double Yes 6.45 0.25 9.0 ft'' 1 ft4 in 1 ft 4 in None None 8 'N 9. Vinyl Low-E Double, Yes -0.45 0.25 20.0 ft2 1 ft 4 in 1 ft4. in None None 9 SE 10 Vinyl. Low-E Double . Yes 0.45 .0.25 9.0 ft2 13 ft 0 in 1 ft 4 in None None 10 E 11 Vinyl Low-E,Double `Yes 0.45 0.25 41.0 ft2 21 ft 01n 1 ft 4 in: None, None 11 S • 16 Vinyl Low-E'Double Yes 0.45 0.25 13.7 ft2 1 ft.4.in 1' ft 41n. None. None 12 S 18 Vinyl Low-E Double Y,es 0.45 0.25 15.0 ft2 1 ft 4 in 1 ft 4 in None None 13 W 20 Vinyl Lovi-E Double Yes 0.45, 0.25 15.0 ft2 1 ft 4 in 1 ft 4 in None None 9/W017 9:05 AM EnergyGaugdO USA FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FnR'nn Rdnti-*)niA GARAGE # Floor Area Ceiling Area Exposed WallPerimeter Avg. Wall Height Exposed Wall Insulation 1 546 ft2 546 ft2 30 ft 8 $ 11 INFILTRATION # Scope Method SLA, CFM 50 ELA EgLA -ACH ACH 50 1 Wholehouse Proposed AGH,(50). .000458 2361.4 129.64 243.81 .334& 7 ' HEATING SYSTEM #. System'Type .,Subtype Efficiency Capacity Block Ducts 1 Electric Strip'Heat. None, COPI 34 kBtWhr 1 sys#1 COOLING SYSTEM: # System Type, Subtype. Efficiency Capacity. Air Flow SHR ` Block Ducts 1 Central Unit Split, SEER: 1.6, 41 kBtulhr cfm 0.8' 1 sys#1 :HOT WATER;SYSTEM # System Type SubTyp& - Location EF Cap Use SetPnt'. Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None FSEC Cert. # Company Name SOLAWHOT WATER,SYSTEM Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS el Location R-Value Area Retum — Air CFM 25.: CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic B . 425 ft2 Attic ' 105'ft2' Default,Leakage Garage (Default) (Default)' 1 1 91172017 9 05=AM En6rgyGauge@)'USA,- FlaRes20l4 Section R405AA Compliant Software Page 5 of 6 FORM R405-2014 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Jun Jul :11:Aug:. S ep Oct Nov Dec Venting Jan Feb [Xj Mar 1Xj A J�May rjJun rl �X� Nov pr ay, Jul Aug.. Sep Oct lx� Dec Thermostat Schedule:; HERS-2006 Reference Hours Schedule Type 1 2 3, 4. 5 6 7 8 9 10 11 12 Coolirig.(WD) ,AM' 78 76 78 .78. 78 76, 78 78: 80 80 80 80 PM 80 80 78,78 78 78 78 71 78 78: 78 78 Cooling (WEH) AM' 78 78 Z8 78 78 78 78 78 78 78 78 78 PM 78 78 78,- 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66, 66 66 68 68 68 68 68 68 .68 PM 68 68 68 68 68 68 68. 68 68 68 66 66 Heating (WEH) AM 66 .66 66' 66. 66 68 66 68 68 68, 68 68 PM_ 68: 68 ..:68 68 68 68 68. :68. 68 .68. 66 66, 9/112017 9`.05 AM EnergyGauge®-USA­ FlaRes2014 Section R405A.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITFIRLd Project Name: BACCI RESIDENCE Builder Name: AMERON HOMES Street: 114 QUEEN BESS COURT Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: BACCI Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks orjoints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. CeiIi^g,attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shalt be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or I r unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting I Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in 1 exiedor walls, or insulation that on installation readily conforms to available space shall emend behind piping and wiring. Shower/tub on exterior wall I Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installer.( separating them from the showers and tubs. Electrcca!/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots I HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. I Fireplace � An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors uhizu -� r �J:u::, i-'N1 EnergyGaugeG USA- FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EFL) DISPLAY ,CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy,Perforrlmance Index; the more efficient the home. 114 QUEEN BESS: COURT, FT. PIERCE; 'FL, 1. New construction or existing. 2. Single family or multiple family, 3. Number of unit% If multiplefamily 4. Number.of Bedrooms- 5. Is this'a�worst case?' 6. Conditioned floor area' (ft2 . 7. Windows*' Description a. U=Factor: Dbl, U=0.45, SHGC: SHGC=.0.25 b. U-Factor: N/A SHGC: c. U-Factor: NIA SHGC: d. U-Factor. N/A SHGC: Afea.Weighted,Avdmge,Mbthang Depth: Area. Weighted Average:' SHGC: 8. Floor Types a. Stab -On -Grade Edge Insulation b. N/A c: N/A New (From Plans) 9. 'Wall Types, Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1' 1811.00 ftz b. Frame -.Wood, Adjacent R=11.0 240.00 ft 1 a. NIA :R= ft2 3 d. NIA R= ftz 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 1964.00 ft2 1964 b, MA R= ft2. Area c. NIA R= ft2 258.67 ft2 11. Ducts a. Sup:.Attic, Ret: Attic, AH: Garage R 'ft2 6 425 ft2 12'. Cooling systems kBtu/hr Efficiency ft? a. Central Unit 41.0 SEER:16.00 ft2 10.223 it. 0.250 Insulation, Area R=0:0 1963.00 ft2 R= ft2 R= ft2 13. Heating systems. A. Electric Strip Heat 14, Hot water, systems a. Electric b. Conservation features None 15. Credits i certify that thisbomb has,'complied with the Florida Energy Efficiency Code for Building Construction _throtagh the above energy saving. features which,will'be installed: (or exceeded) in this home before final inspection. Otherwise; -anew EPLL-Display Card'will'be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home City/FL Zip: kBtu/hr Efficiency 34.0. C6P:1.00 Cap: 50 gallons EF: 0.97 OF, Pstat `Note: This is not.a Building Energy Rating.. . 'If,your Index is below. 7.0, your:h6me may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline -at (321) 638-1492 or'seethe EnergyGauge web sit&dt-ene•rgygauge.com for information and a list.of'certified Raters. For Information, about the; Florida'Building Code; Energy Conservation, contact:the Florida Building Commission's support staff. **Label required,by. Section R303A.3'6f'the Florida Building. Code, Energy; Conservation, if not DEFAULT. 9/1/2017 9:05 AM EnergyGauge® USA - FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1