Loading...
HomeMy WebLinkAboutProduct Approval 10-9-17RECEIVED 08/31/2017 02:26PM Aug 31 17 01:16p HIGHLAND HOMES 7723881411 p.1 1 RECEIVED OCT U J p .1 Force ET1gdinceritig & Testing Inc. l j 19530RnmbluwaodDrive ' Humbla,T%777353 P.retlualuatiion RePar d(TM'ffT4 AkEa7ie4t !) O 111FR�! MEE:4rL•`1, d147C� I" Nail Strip, 24 Gm 16" ~Aide Rood Ponel over 15132" Plywood [Florida Product Approval ## 17796.4 Florida Building Code 2014 Per Rule 61G20-3 Method: 1-13 Category: Roofing Subcategory: Metal Roofing Compliance Method: 61620-3.005(1)(d) NON HYHZ Product Manufacturer: Atlantic Metal 11 of Vero Beach, Inc. 4020 43rd Avenue Vero Beach, Florida 32960 Enr!ineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validaton Locke Bowden, P. E., FL #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1-4 46A�q{%519a7QDSP� �•C E ' £• f �� �`• VrCE11's Far � � ' %f 5TAIE OF .. 1 v°; Az o x -L D 1 4k' ean4 + ,dd pp 0 AIL a tb F9.9 17796A June 11, 2015 ,Aug 31 17 01:17p HIGHLAND HOMES t KEUEIVED 08/31/2017 02:26PM 7723881411 p, 2 1,11" Force Enaineeiing & Testing Inc. f 19530 Ramblewood Drive ' H%mlblc,T_X 7733E Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: 1" Nailstrip Roof Panel, 24 Ga. Steel, 16" Wide, Roof Panel attaching to 15/32" APA Plywood decking. Non-structural Application. Panel Material/Standards: Material: 24 Ga. Steel conforming to Florida Building Code 2014 Section 3.507.4.3 Yield Strength: Min. 50.0 WE Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3 Panel Dimension(s): Thickness: 0.024" Width. 16" max coverage Female Rib: 1" tall Male Rib: '/<" tall rib w/ slotted strip. PanelSeam: Snap Lock Panel Fastener. Through Panel Slot: (1) #10-13 x 1" GP Pancake Type A In Pan of Panel: (2) #10-11 x 1" Eclipse Head Type A Y" minimum penetration through plywood Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6,1507.4.4 Substrate Description: Min.15/32" thick, APA Rated plywood over supports at maximum 24" D.C. Design of plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed in accordance wJ Florida Building Code 2014. Design Uplift Pressures: FL# 17796.4 Table •'A•' Maximum Total Uplift Design Pressure: 59.75 psf 101.0 psf 153.5 psf Panel Slat Fastener Spacing: 16" O.C. 6 W O.C. 6 Y" O.0 Panel Pan Fastener Spacing: NA NA 12" O.C. *Design Pressure includes a Safety Factor= 2.0- � � °°6°pQ999PDBdg�� F s ' ' ;yam fro. '~' • •6 • STATE OF s� •• i sdO� . 4 R E 9J seen cDA. e. oserrm �dPpe��>:08054 °°°1 June 11, 2015 Aug 31 1701:17p HIGHLAND HOMES KEGE1VED 08/31/2017 02:26PM 7723881411 p.3 Force Engineering & Tesdng Inc. " 19530 Ramble«ood Drive Humble; TX 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2014, Section 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: o UL 580-06 -Test for Uplift Resistance of Roof Assemblies o UL 1997-04 - Uplift Test for Roof Covering Systems • TAS 100-95 - Test Procedurefor Wind and Wind Driven Rain Resistance of Discontinuous Roof Systems Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization #TST 5328) Report No. 72-0314T-06*, Dated 03/24/2007 2. TAS 100-95 Farabaugh Engineering & Testing, Inc. (FBC Organization it TST-16541 Report No. T158-071, Dated 04/05/2007 3. Certificate of Independence By Terrence E. Wolfe, P.E. (No.44923] @ Force Engineering & Testing, Inc. (FBC Organization #LANE ID: 1920) Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Sections 1507.4.2 and in accordance with Manufacturers recommendations. onstallation: Install per manufacturer's recommended details. Underlayment: Self -adhered roofing underlayment minimum 40 mil thickness. Roof Panel Fire Classification: Fire classification is not part of this acceptance.. �o4p9D &95fl P RpgtgO� D � C E Al .S j �� T�'� •� �^`�,�✓ fit'_ .. �'�+ ! , STATE OF saos.oremna, ''e mf cati uasm -'D7p0�� 866n 9�0� ]FL# 17796.4 .Sane 11, 2015 ,Aug 31 17 01:17p HIGHLAND HOMES RECEIVED 08/31/2017 02:26PM 7723881411 p.4 + Force Engineerring & Testing Inc. I` "+ 19530 Ramblewood Drive I.I omblc,TX 77338 Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2014 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for properfastener attachment to his structure and analyze the panel fasteners forpullout and pullover. Supportfrdming must be in compliance with Florida Building Code 2014 Chapter 22 forsteel, Chapter23 for wood and Chapter 16 forstructural loading. `The Test Reports are owned by Metalforming, Inc. Metalforming, Inc. gives the above manufacturer permission to use these test reports. `0.�pa44flooFt�a�pd� a cesF�'f: NO. 40�i . y' rP •�+' STATS OF r t asp orc�cs m S • • . ' G9� �� axes �l9 S1 N AL' E. 4� d Fin h 4146be IFIL# 17796.4 June 11, 2015 Aug 31 17 01:17p HIGHLAND HOMES KLULIVtV b8/JI/2017 02:26PM7723881411 p.5 A 30 ydil5l•rip 1" 71 0.299 Sc Ao RO138 I.11B o i �I o �4 jm.A .f.h nq ��erlli�h! Hallalah Halle aA9! loiaa+7mglh. .ua Em Ima— NAILSTRIP I.. 00590015 i• �r�`al.�sosa�anair. ern No.23 .o 06 [� ,•R .•���� LL7le ut Flaitlm eP�l�as�Q �"`q0°,+ +H 29798 'FEB FEB 14D 7oJroi ltr•9! RECEIVED 08/31/2017 02:26PM 'Aug 31 1701:17p HIGHLAND HOMES 7723881411 p.6 1 _1 TYPE 1 FASTENER PATTERN (SEE LOAD TABLE 16" m � _m 15/32" PLYWOOD L#10-1,3 x I" GP TYPE A PANCAKE W/ GRACE ICE ,g WATER SHIELD SEE LOAD TABLE FGR SPACING OVER ENTIRE ROOF DECI< TYPE 2 FASTENER PATTERN (SCE LOAD l'ABLE) i A" I A" r'r I O-1 3 x 1" TYPE A PANCAKE 0 6 3/4-" O.C. 15/32" PLYWOOD W/ GRACE ICE & WXrER SHIELD OVER ENTIRE ROOF DECK 1 G" t Y 11 4" (2) 1110-11 X I" ECLIPSE HEAD @ 1 2" O.C. PER PANEL t;lyyt4lifats "pdF GE E. , P1a.+b4923 a y • w Its • _ w Ito OJF7a7�>�O't`c� � 0 R ot'_��j� io FEB 1015