HomeMy WebLinkAboutEngineering ProjectK IMMMBV y ENGINEERING, INC. MOIA BOWLES VILLAMIZAR & ASSOCIATES www.mbveng.com CA #3728 December 14, 2017 Mr. Carl Peterson, Building Official St. Lucie County Building Dept. 2300 Virginia Avenue Fort Pierce, FL 34982 Subject: 114 Queen Bess Court Permit Number. 1 0 y0-99 Fort Pierce, Florida Engineer's Project Number: 16-0302 Dear Mr. Peterson: s This letter shall serve as certification that for the subject project, the soils under the footers for the bearing walls have been improved with pressure compaction in accordance with the parameters of the soil investigation by KSM Engineering and Testing Project 170997-b. The footers received injection points spaced between 5 and 6 feet, where bearing improvement was required as coordinated on the field and in accordance with the structural drawings; the pressure grouting injection consisted of a cement base mixture in a 2:1 proportion injected at low velocity to 4 to 7 feet of depth, to a maximum of 30 psi of pressure. Should you have any questions regarding the above subject, please do not hesitate to contact our office. `\����I V truly O ,00,.•�,�cENS�,?l��� No. 61000 9� Ro 01 o ill fir, MTATE OF FL P.E. # 61 t�' �<ORID ,�ONAL 'SENG�� RV/jeh /1/11111I 1250 W. Eau Gallie Blvd., Suite L 1835 20th Street 806 Delaware Avenue Melbourne, FL 32935 Vero Beach, FL 32960 Ft. Pierce, FL 34950 321.253.1510 772,569.0035 772.468.9055 Fax: 321.253.09 11 Fax: 772.778.3617 Fax: 772.778.3617 759 S. Federal Highway, Suite 200B Stuart, FL 34994 772.266.9795 Fax: 772.778.3617 M B V ENGINEERING, INC. MQ1A BbWL9SVILLaMIZAR &ASSOCIATES w4vw,mbvei1g.00M CA #3728 December 4, 2017 A,meron Homes, Inc. P.O. Box 780874 Sebastian, FL 32978 Subject: 114 Queen, Bess Court Fort Pierce, Florida _._ .�.. _. .........� Engineer's Project -Number: Dear Sirs: ,(-& � Tcq - o Z��6f q 16-0302 _.._.. This letter shall serve as certification, that for the subject project, the soils under the footers for the bearing walls have been improved with pressure compaction in accordance with the parameters of the soil investigation by KSM Engineering and Testing Project 170997-b. The footers received injection points spaced between 5 and 6 feet, where bearing improvement was required as coordinated on the field and in accordance with the structural drawings; the pressure grouting injection consisted of a cement base mixture in a 2:1 proportion injected at low velocity to 4 to 7 feet of depth, to a zxaaximuni of 30 psi of pressure. Should you have any questions regarding the above subject, please do not hesitate to contact our office. `\\1111 i 1111/o/, .��N\F a VIt 4 Very truly youts 0 0 sF' ; I �.- ` No, 61000 � 1�0olfo V�il r/+��4)j�pgq+� P_ �e}�yi�/� p ���!/ : _ Y . •__ __. LATF r.R. R.V/sl r1 I it lll\ CC. PGI 1250 W Eau Gallie Blvd., Suite L 1835 20th Street 806 Delaware Avenue Melbourne, FL 32935 Vero Beach, FL 32960 Ft. Pierce, FL 34950 32 I.253.1510 772.569.0035 772.468.905S Fax 321,253,091 1 Fax 772-778.3617 Fax:772.778.3617 759 S. Federal Highway, Suite 200B Stuart, FL 34994 772.266.9795 Fax: 777.778.3617