Loading...
HomeMy WebLinkAboutLetter - Final Survey RevisionTECH ARTDESIGN& ENGINEERING, INC. +4S . r u"' ':�ii' t1'u :rrn:� r l R� :. d 3a Mkt Lei °. ar ii'y"'^ 8530 U.S. Highway 1, Suite 8 Micco, Florida 32976 Phone (772) 663-6991 Fax (772) 663-6992 August 8, 2018 St. Lucie County Planning & Development Services RECEIVED Building & Code Regulation Division 2300 Virginia Avenue AUG 0 9 2018 Fort Pierce, Florida 34982 ST. Lucit? County, Permitting RE: Permit 91707-0599 114 Queen Bess Court, Fort Pierce, Florida Bacci Residence Contractor: Ameron Homes To Whom It May Concern: The Grading Plan for the above -referenced new home recently completed and applying for a Certificate of Occupancy, calls for (3) areas of storm water retention. These proposed (3) areas will provide approximately 480 cu. ft. of storm water retention ((318 cu. ft. required) reference approved Grading Plan). After a review of the final survey revision dated 8.1.18, by Know it Now, Inc., Professional Surveying and Mapping, the proposed (3) areas of retention are now (1) area. The storm water will now be directed toward the Indian River and not onto adjoining properties. The existing wood seawall with a height of 2.70' +/- and the grade landward of the seawall at 2.15' +/-, indicates a Swale along this seawall of approximately 130' in length and approximately 10' wide and 6"-7" below the top of the seawall. This will provide approximately 358 cu. ft. of storm water retention, which satisfies the retention required of 318 cu. ft. It is my understanding that the wood seawall is now being replaced with a concrete seawall. The engineered drawings for this new seawall, as provided by others, should provide and/or maintain this retention/swale area. Please feel free to contact me if you have any questions. Arthur F. riep Professional Engineer 424683 . AFP/dd TECH ART DESIGN & ENGINEERING, INC. F i 'T o t a t / R w. Fl1GdI; '+� 1�L'C it zm 8530 U.S. Highway 1, Suite 8 Micco, Florida 32976 Phone (772) 663-6991 Fax (772) 663-6992 August 8, 2018 St. Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, Florida 34982 RE: Permit # 1707-0599 114 Queen Bess Court, Fort Pierce, Florida Bacci Residence Contractor: Ameron Homes To Whom It May Concern: RECEIVED AU6 0 9 2018 ST. Lucie County, Permitting The Grading Plan for the above -referenced new home recently completed and applying for a Certificate of Occupancy, calls for (3) areas of storm water retention. These proposed (3) areas will provide approximately 480 cu. ft. of storm water retention ((318 cu. ft. required) reference approved Grading Plan). After a review of the final survey revision dated 8.1.18, by Know it Now, Inc., Professional Surveying and Mapping, the proposed (3) areas of retention are now (1) area. The storm water will now be directed toward the Indian River and not onto adjoining properties. The existing wood seawall with a height of 2.70' +/- and the grade landward of the seawall at 2.15' +/-, indicates a swale along this seawall of approximately 130' in length and approximately 10' wide and 6"-7" below the top of the seawall. This will provide approximately 358 cu. ft. of storm water retention, which satisfies the retention required of 318 cu. ft. It is my understanding that the wood seawall is now being replaced with a concrete seawall. The engineered drawings for this new seawall, as provided by others, should provide and/or maintain this retention/swale area. Please feel free to contact me if you have any questions. Arthur F. Priep Professional Engineer #24683 AFP/dd