HomeMy WebLinkAboutPool Layout & Piping Plan18" RAISED SPA
18" BENCH - 20" BELOW W.L.
(6) THERAPY JETS
(2) FILTERED INLETS
AQUASTAR 32CDFL - 32" CIIANNEL
DRAIN (316 GPM @ 3.9 FT/SEC THRU
GRATE - SINGLE UNBLOCKABLE
OR EQUAL /
(1) SPA LIGHT
Z5' SCH 4\\\
(2) LIGHTS
o
j 41/
POOL/SPA EQUIP.
SEE SITE PLAN:
BY OTHERS
REINFORCED R PRODUCT APPROVED
CONCRETE SLAB(S)
(FIELD VERIFY SIZE &LOCATION)
jj
2.5" SCH 40
I
5'-0" DEPTH
2s" H 40 1 9'-7"
18" BENCH =
20" BELOW
I18" BENCH - `� : W.L.
I20" BFT')W \ ---
12 6" STUB-OU FOR 13'
IT-7" POOL CI, ANER
Pool Layout & Pi
SCALE: 1/4"=1'-0"
AQUASTAR 32CDFL - 32"
CHANNEL DRAIN (316 GPM @ 3.9
FT/SEC THRU GRATE - SINGLE
UNBLOCKABLE COMPLIANT W/
ASNIE/ANSI A 112.19.8 - 2014
OR EQUAL
%4;k
AIBTAI
ROAN ER
ine Plan
12'-9"
23'
SUN SHELF STEPS
240 SQ. IN. MIN.
TOP TREAD
TYP BOTH SIDES
PERIMETER BONDING
WIRE @ 18"MIN. - 24" MAX.
FROM W.L. (SEE DETAIL)
13'-7"
151 4"
NOTE:
POOL CONTRACTOR TO VERIFY ALL
PROPERTY LINE LOCATIONS AND POOL
ELEVATION PRIOR TO CONSTRUCTION.
POOL LAYOUT AND DIMENSIONS TO BE
VERIFIED W/ OWNER PRIOR TO
CONSTRUCTION
EXIST. RESIDENCE
Pool Piling Plan
SCALE: 1/4"=1'-0"
L_
J
y
.kjj
EXIST.
RESIDENCE
W�
P� In
d Q
��Y,`, Q: • * • a �� DPP
4{ .. .• •%APPP
,,4
LL
O O;
I
°y Z
k. �.
ti
r
a
o a
a
CIO)
U
ar,
W
W
a
W �w
C�
r.6q
w
DRAWN BY:
MAP
CHECKED BY:
WJC
DATE:
4-03-17
SCALE:
AS NOTED
JOB NUMBER:
17-248
SHEET
OF 2
SAND SET, nTERLOCKING
PAVER DECK
BULLNOSE
BRICK COPING
SLOP DECK @ y" PER. FOOT
3"
CLEAN FILL COMPACTED TO
p
I- 95 % MAX. DRY DENSITY
I-
UNDER DECK ONLY
�*
2-#4 DLA.
TOP OF BEAM
MARCHE ORE UAL ^ I I�-REINFOB
(SEE SHE
RADIRIS
VARIES
TYPICAL WALL SECTION
sa
FROM POOL SUPPLY
a
�3
�/" OR I" PVC CONDUIT
HALOGEN OR LED
LIGHT W7 METAL TRIM
METAL LIGHT NICHE
(MIN.9 SQ. IN SURFACE
AREA EXPOSED TO
#8 SOLID COPPER BOND WIRI
WATER)
ADD (4) #4 DIA. - 18" LONG
POOL STEEL
DIAGONALLY AROUND
LIGHT NICHE
LIGHT DETAIL
18" MIN: 24" MAX.
(ENTIRE PERIMETER)
W.L. _
4"-6"
#8 SOLID BARE COPPER BOND _
WIRE W7 APPR. CLAMPS I I_ I I I I- BELOW SOB -GRADE
(ONE ON EACH SIDE OF
POOL-4TOTAL) III -I -I
4" TVCK x 3' WIDE 2500 P.S.I.
CONCRETE SLAB W/ (1) #8 BARE SOLID COPPER WIRE
(UNDERSLAB)
BONDED TO POOL STEEL AS SHOWN
EOUIPOTEN'EIAL BONDING DETAIL
PER FLORIDA BUILDING CODE ADAPTATION OF
N.E.C. 2011 SEC. 680.26
VACUUM FITTING W/
SELF -CLOSING SAFETY COVER
(HAYWARD MODEL #400
OR EQUAL)
VACUUM LINE DETAIL
(WHEN,MPLICA➢LE)
ry �
i
DARK CONTRASTING
CAP TILE
BENCH SECTION
(WHEN APPLICABLE)
III';
MAX.
I I'
HANDHOLD SHALL BE ACCESSIBLE WITHIN 4 FEEI
NOT TO EXCEED 8 FEET AT ANY TWO POINTS
ALONG THE INSIDE OF THE POOL PERIMETER
WHERE THE WATER DEPTH EXCEEDS 4 FEET
HANDHOLD DETAIL
(WHEN APPLICABLE)
26,
94 DIA. REBAR 91 5 11 14
@ 12" O.C.E.W. 12" 12"
T-5" u -
10.5
#4 DIA. REBAR
TOP MAT-' r ''
SPA SECTION
SCALE: 318" = F-0"
41I MIN.
SHIMMER COVER W1 WRAP (2) 03 DIA. AROUND
ADJUSTABLE COLLAR SKIMMER, TIED TO POOL STEEL
I
LEAF BASKET
- I
TO POOL PUfjIP
25 GPM MINI FLOW
SKIMMER DETAIL
HEATER (GAS) - IGNAITION SWITCH
3 - 412 THHN CU WITHIN 1/2" CONDUIT
POOL PANEL W/ 80 AMP BRKR & MANUAL MOTOR STARTER SWITCH
(2) - 94 & (2) 010 GND 3 HP PENTAIR INTELLI FLO PUMP MOTOR w/
THIN CU IN BUILT-IN OVERLOAD SWITCH W/ 3 - #10 THIN CU
11/4" RPVC CONDUIT WITHINY," MIN. CONDUIT
(IME PROTECTED)
IME CLOCK
S.P.S.T. TOGGLE --------{(( W. P. DISCONNECT
SWITCH
12 VOLT TRANSFORMER
(2) POOL LIGHTS
(GFI NOT REQUIRED) JUNCTION BOX
(1) SPA LIGHT
(GFI NOT REQUIRED)
1. ALL ELECTRICAL TO COMPLY WITH 2O11 NATIONAL ELECTRIC CODE.
ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY
AT POINT OF CONNECTION.
2. 3412 THIN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LIGHT(S).
3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/ #8 SOLID, BARE COPPER.
4. PROVIDE W.P.G.F.I. OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE.
5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B).
ELECTRICAL DIAGRAM
AQUASTAR 32CDFL - 32"
CHANNEL DRAIN (316 GPM .
@ 3.9 FT/SEC THRU GRATE -
SINGLE UNBLOCKABLE
OR EQUAL
FINISH PLASTER
HYDROSTATIC RELIEF VALVE &
PERFORATED PVC COLLECTION
TUBE, WHERE REQUIRED
N.T.S.
-- 32" 3 3/32"
HYDROSTATIC RELIEF VALVE
PORT OR CAP OFF
FLOOR
\ MAIN DRAIN SUCTION LINE
TIED TOGETHER AS SHOWN
ABOVE - PIPE SIZE PER
PLAN
MIN. %2 YARD GRAVEL SUMP
NOTE: 25.9 SQUARE INCH OPEN AREA, WRAPPED W/ DRAIN FEILD
316 GPM = 3.9 FEET PER SECOND CLOTH (RECOMMENDED)
Channel Main Drain Detail
SCALE; 3/8" =1'-0"
21-711
POOL SPECIFICATIONS
SIZE: 22' X 26' DEPTH: 3' TO 5'
VOLUME: 9,784 GALLONS ELEVATION: DET. ON SITE
TURN OVER RATE: 6.46 HR. 0J, 36 GPM MAX. - LOW SPEED
(TURN OVER RATE: 1.5 HR. (! 150 GPM - HIGH SPEED)
DESIGN FLOW RATE: = 9,784 GAL./6 HRS./60 MIN. = 27 G.P.M.
TILE: STANDARD THERAPY JETS: (6) IN SPA
POOL FINISH: MARCITE OR EQUAL
PIPING: SCH. 40 INLETS: POOL (3) SPA (THRU JETS)
DECK: PAVERS ELECTRIC: BY OTHERS
POOL LIGHT: (2) LED SPA LIGHT: LED
LADDER: NO HANDRAIL: NO
PUMP: 3 HP PENTAIR INTELLI FLO VS-3050
A.P.S.P. PUMP CERT.: CURVE C - 51 GPM (a,) 1725 RPM
FILTER: CLEAN & CLEAR CCP420
CARTRIDGE - 420 SQ. FT. FILTER AREA
HEATER: 400,000 BTU GAS HEATER
VACUUM LINE: YES
POOL AREA: 309 S.F. PERIMETER 77 L.F.
SPA AREA: 32 S.F. PERIMETER 20 L.F.
AUTO -FILL: NO OVERFLOW: NO
PUMP FRAME OR FILTER
TANK MOUNT OR HEATER
ANCHOR POOL PUMP AND
FILTER PER MFGR'S. N.O.A.
�J 4" THICK RER ICEL,_,NCRETE SLAB
2„ MIN
E.G. PUMP
FILTER �,ATER
POOL PUMP, FILTER
AND HEATER ANCHOR
POINTS MAY VARY
POOL EQUIPMENT ANCHORING DETAIL
SEE MFGR. SPECIFICATIONS FOR ADDITIONAL ANCHORING
BYFORNLATION- EQUIPMENT SHAPES MAY VARY
I1
EQUIPMENT LAYOUT
SCALE: N.T.S.
LEGEND
1. 3" SPA MAIN DRAIN LINE
2.2" VACUUM LINE
3.3" POOL MAIN DRAIN LINE
4.2" SKIMMER LINE
5.3" POOL RETURN LINE
6. 3" RETURN TO JETS
A. 3 HP PENTAIR INTELLI FLO REC.
PUMP W/ APPR HAIR & LINT STRAINER
B. CARTRIDGE FILTER W/ PRESSURE
GAUGE AND AIR RELIEF VALVE
C. 1.5" TO WASTE OR DISCHARGE
TO GROUND
D. 400,000 BTU GAS HEATER W/
INTERNAL BY-PASS
E. VALVES (TYPICAL)
GENERAL NOTES:
1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE
GROUNDED PER CODE.
2. POOL TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM
COMPRESSIVE STRENGTH OF 4000 P.S.I. AT 28 DAYS.
3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS
OF NEW BILLET STEEL, CONFORMING TO ASTM A-615, GRADE 60, STEEL SRALL
BE BENT, LAPPED AND PLACED IN ACCORDANCE WITH ACI STANDARDS.
4. GRATE IN MAIN DRAIN SHALL HAVE A FREE AREA OF 4 TIMES THE AREA OF
THE SUCTION LINE.
5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER.
6. POOL TO BE FENCED PER LOCAL CODES.
7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE.
8. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY
WITH THE REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSI/ NSPI 5;
ANSI/ NSPI 6; AND ANSI/APSP 7 2006 AND ANSI/APSP.ICC-15 2011.
9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER
DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS
DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM
NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN
OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT.
10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH
THE FBC FIFTH EDITION (2014) - RESIDENTIAL, SECTION R4101-PRIVATE
SWIMMING POOL AND LOCAL AMENDMENTS, IF ANY.
It. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC FIFTH
EDITION (2014) - RESIDENTIAL CHAPTER 45 - PRIVATE SWIMMING POOL.
12. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS,
POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION.
(CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR)
13. POOL PLANS ARE DESIGNED TO MEET THE FBC FIFTH EDITION (2014) -
RESIDENTIAL - PRIVATE SWIMMING POOLS.
14. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN
ACCORDANCE WITH REQUIREMENTS OF ANSI/APSP 7-2006 AND FBC FIFTH
EDITION (2014) - RESIDENTIAL CHAPTER 45.
PLUMBING NOTES:
1. ALL PIPING, EQUIPMENT AND MATERIALS USED IN THE PLUMBING SYSTEM OF
SWIMMING POOLS THAT ARE BUILT IN PLACE SHALL CONFORM TO THE FBC
FIFTH EDITION (2014), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING
POOLS.POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT
EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES
AND 10 FT/SEC. PRESSURE LINES.
2. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE
FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE
SLABS SHALL BE SET IN A PIT HAVING AT LEAST A DIMENSION OF FIVE
DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A
SUITABLE COVER. ALL VALVES SHALL BE LOCATED WHERE THEY WILL BE
READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL.
3. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR
VERTICAL CHECK PATTERN.
4. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY-PASS
OR ANTI -SIPHON DEVICE INSTALLED TO PROVIDE A POSITIVE MEANS OF
RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION.
5. ALL POOL PIPING $HALL BE 1.5" SCH. 40 PVC EXCEPT AS SHOWN AND SHALL
BEAR THE H.S.P. SEAL OF APPROVAL.
6. THIS POOL/SPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES
WHEN EMPTY, FOR WATER TABLE UP TO Y-0" BELOW POOL/SPA DECK
ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE
ELEVATIONS, ALL POOL/SPA `'-- kLL F V FITTED WITH A HYDROSTATIC F-TAEF
VALVE.`�-
7. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS
SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL.
8. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER
SUPPLY WHICH IN THE JUDGEMENT "r THE ADMINISTRATIVE AUTHORITY
MAY BE USED TO FILL THE Pc IF �,,JIPPED WITH BACKFLOW PROT: 40k -,
NO OVER -THE -RIM FILL SPOUT WILL BE ACCEPTED UNLESS LOCATED UNDER
A DIVING BOARD, OR PROPERLY GUARDED.
9. ALL POOL/SPA PIPING SHALL BE INSPECTED AND APPROVED BEFORE
COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO
THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC
WATER TEST OR AIR PRESSURE TEST OF NOT LESS THAN 35 PSI FOR 15
MINUTES.
10. JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FLORIDA
BUILDING CODE, PLUMBING.
11. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR
UNION CONNECTION ADJACENT TO THE HEATER.
12. PURPLE PRIMER REQUIRED ON ALL PVC PIPING PER FBC FIFTH EDITION (2014)
605.21.
13. GAS PIPING SHALL COMPLY WITH FLORIDA BUILDING CODE FUEL GAS.
(SEPARATE PLANS AND PERMIT REQUIRED)
14. SWIMMING POOL/SPA WATER HEATERS SHALL BEAR THE LABEL OF A
RECOGNIZED TESTING AGENCY.
15. PROVIDE BACK FLOW PREVENTOR ON WATER SUPPLY.
POOL SYSTEM FLOW RATE: 150 GPM
(MAXIMUM FLOW FROM PUMP CURVE)
REC./ THERAPY PUMP = 3 HP PENTAIR INTELLI FLO VS-3050
VARIABLE SPEED - LOW SPEED = 36 GPM MAX.
HIGH SPEED = 150 GPM @ 50 TDH
3" SUCTION PIPE @ 150 GPM = 6.63 FT./SEC.
(8 FT./SEC. MAX. - SUCTION LINES)
2.5" BRANCH PIPE @ 75 GPM = 5.13 FT./SEC.
(6 FT./SEC. MAX. - SUCTION LINES)
3" PRESSURE PIPE @ 150 GPM = 6.63 FT./SEC.
(10 FT./SEC. MAX. - PRESSURE LINES)
CARTRIDGE FILTEII = 27 GPM @ 0.375 GPM/ SQ. FT.
= 72 SQ. FT. FILTER AREA
ti
�
M
M
U
V1 F�4
U
O
,�°,PAP . * y'�� ��'..•
C40f�
O O;
Uje:v m
z
:w m *
3m
LU � ®
�
2°•v O
� • �j Z
¢ ®:O
t�A env: � .e
°Serr*ssiPUIA6
CIO
W
'J M 00 h
~n rF M
O I o v
cq
F-� 00 96� P6y
U v
C
W
W
O
E�
F
O
H
U
z
�
i
v
H
H
no
V
® Q
W C)
I-r
�
]NOTED
BY:
BY:
7
:
ED
ER:48