Design Pressure
Florida Window & Door Co. 1 125 N.Dixie Hwy Tel.(561)848-4900 LakeWorth, FL 33460 Floridawindowanddoor.com Property Information Building Information Owner: Crystal Ann Speirs Wind Zone: 160 MPH. Address: 10450 W Midway Rd Exposure Category: C Fort Pierce,FL 34945 Minimum Building Dimension: 30 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 0 Int 0 0 7 0.0 0.0 1 End 68 82 7 30.5 -38.9 2 End 25 63 7 33.3 -44.4 3 End 50 63 7 31.8 -41.4 4 End 25 63 7 33.3 -44.4 5 End 33 80 7 32.2 -42.2 6 End 37 50 7 32.9 -43.7 7 End 106 38 7 31.2 -40.4 8 End 106 38 7 31.2 -40.4 9 End 53 16 7 33.5 -44.8 10 End 37 63 7 32.4 -42.7 11 End 19 63 7 33.5 -44.8 12 End 19 63 7 33.5 -44.8 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page 1 of 1