Loading...
HomeMy WebLinkAboutEL200 Horizontal Roller 20-1208.07 i MIAMI-DADE MIAMI-DADE COUNTY ® PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) wwwauiamidade.2ov/buildinQ E.S.Windows,LLC 3550 NW 49" Street Miami,FL 33142 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction.RER reserves the right to revoke this acceptance if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "EL200"Aluminum Horizontal Rolling Window-L.M.I. APPROVAL DOCUMENT: Drawing No. W16-86, titled `ES-EL200 Horizontal Rolling Alum. Wdw. (L.M.I.)",sheets 1,2,3,3.1,4 and 5 through 11 of 11,dated 12/19/16,with revision D dated 06/22/20,prepared by Al-Farooq Corporation, signed and sealed by Jalal Farooq,P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, Barranquilla, Colombia, model/series, and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 18-0221.03 and consists of this page 1 and evidence pages E-1,E-2,E-3 and E-4,as well as approval document mentioned above. i The submitted documentation was reviewed by Manuel Perez,P.E. MIAMI•DADE COUNTY NOA No.20-1208.07 a , Expiration Date: January 19,2022 Approval Date: February 18,2021 T2/10/211 Page 1 ! i I 3 E . S . Windows , LLC NOTICE OF ACCEPTANCE . EVIDENCE SUBMITTED i 1 . EVIDENCE SUBMITTED UNDER PREVIOUS NOA ' s A. DRAWINGS 1 . Manufacturer' s die drawings and sections . (Submitted under NOA No. 164617. 04) 2 . Drawing No . W16-86 , titled "ES -EL200 Horizontal Rolling Alum . Wdw . (L . M . I . )", sheets 1 through 11 of 11 , dated 12/ 19/ 16 , with revision C dated 01 / 12/ 18 , prepared by Al -Farooq Corporation, signed and sealed by Javad Ahmad, P . E . (Submitted under NOA No. 18-0221. 03) Be TESTS 1 . Test reports on : 1 ) Large Missile Impact Test per FBC , TAS 201 - 94 2) Cyclic Wind Pressure Loading per FBC , TAS 203 -94 along with marked-up drawings and installation diagram of an aluminum horizontal sliding window, prepared by Blackwater Testing, Inc . , Test Report No . BT -ESW47407, dated 10/24/ 17 , and addendum letter dated 12/ 15/ 16, both signed and sealed by Constantin Bortes , P . E . (Submitted under NOA No. 18-0221. 03) 2 . Test reports on : 1 ) Air Infiltration Test, per FBC , TAS 202 - 94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 - 94 3 ) Water Resistance Test, per FBC , TAS 202-94 4) Forced Entry Test, per FBC, and TAS 202- 94 5) Large Missile Impact Test per FBC , TAS 201 - 94 6) Cyclic Wind Pressure Loading per FBC , TAS 203 - 94 along with marked-up drawings and installation diagram of an aluminum horizontal sliding window, prepared by Blackwater Testing, Inc . , Test Report No . BT -ESW- 16-007, dated 12/08/ 16 , signed and seated by Constantin Bortes , P . E . (Submitted under NOA No. 164617. 04) Co CALCULATIONS 1 . Anchor verification calculations and structural analysis , complying with FBC 511, Edition (2014) , dated 06110115 , prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P .E . (Submitted tinder NOA No. 16-0617. 04) 2 . Glazing complies with ASTM E1300-09 I D . QUALITY ASSURANCE L Miami-Dade Department of Regulatory and Economic Resources (RER) . j I I Manuel Perez, P.E. Product Control Ex r NOA No . 20- 08. 07 Expiration Date : January 19, 2 Approval Date : February 18 , 2021 E - 1 t I i E . S . Windows , LLC NOTICE OF ACCEPTANCE : EVIDENCE SUBMITTED 1 . EVIDENCE SUBMITTED UNDER PREVIOUS NOA ' s (CONTINUED) E . MATERIAL CERTIFICATIONS L Notice of Acceptance No . 17-0808 . 02 issued to Kuraray America, Inc. for their "SentryGlas© (Clear and White) Glass Interlayers " dated 12/28 / 17 , expiring on 07/04/23 4 2 . Notice of Acceptance No . 174114 . 14 issued to Kuraray America, Inc . for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers " dated 01 / 18/ 18 , expiring on 07/08/ 19 , 3 . Notice of Acceptance No . 17-0712 . 03 issued to Eastman Chemical Company (MA) for their "Saflex CP an Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/ 17 , expiring on 12/ 11 / 18 , 4 . Notice of Acceptance No . 17-0712 .05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/ 17 , expiring on 05 /21 /21 . F. STATEMENTS 1 . Statement letter of conformance to FBC 5' Edition (2014) and FBC 6t" Edition (2017) , and of no financial interest, dated 09/25/ 17 , issued by Al -Farooq Corporation, signed and sealed by Javad Ahmad, P . E . (Submitted under NOA No. 174114. 06) 2 . Distributor Agreement signed by Carlos Garcia and by Evelyn Daes . (Submitted under NOA No. 16- 0617. 04) 3 . Laboratory compliance statement for Test Report No . BT-ESW4 &007, issued by Blacicwater Testing , Inc . , dated 12/08/ 16 , signed and sealed by Constantin Bortes , P . E . (Submitted under NOA No. 16-0617. 04) 4 . Proposal No . 16=1228 issued by the Product Control Section, dated 11 / 16/ 16 , signed by Manuel Perez, P . E . (Submitted under NOA No. 164617. 04) i, G. OTHERS 1 . Notice of Acceptance No . 174114 . 06, issued to ES Windows , LLC for their Series "EL200 " Aluminum Horizontal Rolling Window - L .M . I . , approved on 01 / 11 / 18 and expiring on 01 / 19/22 . i Manuel Perez, P . . Product Control Exa r NOA No . 20- 08. 07 Expiration Date : January 19, 2 Approval Date : February 18, 2021 E - 2 i i i E . S . Windows , LLC NOTICE OF ACCEPTANCE : EVIDENCE SUBMITTED 2 . NEW EVIDENCE SUBMITTED A. DRAWINGS 1 . Drawing No . W16-86 , titled "ES -EL200 Horizontal Rolling Alum . Wdw . (L .M . I . )" , sheets 15 2 , 3 , 3 . 15 4 and 5 through 11 of 11 , dated 12/ 19/ 16 , with revision D dated 06/22/20 , prepared by Al-Farooq Corporation, signed and sealed by Jalal Farooq, P . E . B , TESTS 1 . Test reports on : 1 ) Air Infiltration Test, per FBC , TAS 202 - 94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3 ) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201 - 94 5 ) Cyclic Wind Pressure Loading per FBC , TAS 203 - 94 along with marked-up drawings and installation diagram of an aluminum horizontal sliding window, prepared by Fenestration Testing Laboratory, Inc . , Test Report No . FTL41027, dated 04/23 /20, signed and sealed by Idalmis Ortega, P . E . Co CALCULATIONS 1 . Anchor verification calculations and structural analysis , complying with FBC 5 "' Edition (2014) , dated 06/ 10/ 15 , and updated on 11 /09/20 to comply with FBC 711, Edition (2020) , prepared by Al-Farooq Corporation, signed and sealed by Jalal Farooq, P . E . 2 . Glazing complies with ASTM E130049 D . QUALITY ASSURANCE 1 . Miami-Dade Department of Regulatory and Economic Resources (RER) X"Utc.jo� i I i I i I i i Manuel Perez, P.E. Product Control Ex n r NOA No . 20-1 08. 07 Expiration Date : January 19, 2 Approval Date : February 18, 2021 E - 3 i 1 i ; E . S . Windows , LLC i NOTICE OF ACCEPTANCE : EVIDENCE SUBMITTED 2 . NEW EVIDENCE SUBMITTED (CONTINUED) E . MATERIAL CERTIFICATIONS 1 . Notice of Acceptance No . 18-0725 . 11 issued to Kuraray America, Inc . for their "Kuraray SentryGlas® XtraT's (SGXTM) Clear Glass Interlayer" dated 05/23 / 19 , expiring on 05 /23 /24 . 2 . Notice of Acceptance No . 19-0305 . 02 issued to Kuraray America, Inc . for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers " dated 05 /09/ 19 , expiring on 07/08/24 . 3 . Notice of Acceptance No . 20-0622 . 01 issued to Eastman Chemical Company (MA) for their "Saflex PVB Clear and Color Glass Interlayers " dated 08 /06/20 , expiring on 05/21 /21 , 4 . Notice of Acceptance No . 20-0622 . 03 issued to Eastman Chemical Company (MA) for their "Saflex Storm on Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 08 /06/20 , expiring on 12/ 11 /23 , F . STATEMENTS 1 . Statement letter of conformance, complying with FBC 6111 Edition (2017), with FBC 7t` Edition (2020), and of no financial interest, dated November 9, 2020, issued by Al-Farooq Corporation, signed and sealed by Jalal Farooq, P .E . 2 . Proposal No . 18-0784 issued by the Product Control Section, dated 06/29/ 18 , signed by Manuel Perez, P . E . G. OTHERS 1 . Notice of Acceptance No . 18-0221 . 03 , issued to E . S . Windows , LLC for their Series 44EL200 " Aluminum Horizontal Rolling Window - L . M . I . , approved on 05/ 10/ 18 and expiring on 01 / 19/22 , i I I Manuel PeV408. 0 Product Control E NOA No . 20Expiration Date : January Approval Date : February 18, 2021 E - 4 I I 72 15/16" 72 15/16" 72 15/16" FRAME WIDTH FRAME WIDTH TWINE WIDTH 12" a (3)ANCHORS t9"MAX (3}ANCHORS I9"MAX (3)ANCHORS MAX. AT MTG.STILE ENDS AT MTG.STILE ENDS AT MTG.STILE ENDSm T MAX. AT 5"O.C. H 'O 7"MAX. AT 5"0.0. H 6�MAX. AT S"O.C. HEAD Z b m HEAD/SILL + HEAD/SILL HEAD/SILL q CORNERS ;,4., -4 CORNERS CORNERS g rI O W N I � N I I I I y j 05N� II r 7//� C6 E V 0>� I; O t� -'fl- Tr— - N V e0 U - t--�T _ 0 6r C ei li ^ ^> I F 0 2 �=�0 � Il II \ n 0 V i. II ! O�If �W m i II I w m u1�� Il�il NW W of -� III ti �.�2J q� ' Q W 7 I. Ip �> ffYII m 4y - li- .,, =�>Im 1L Z o�m Dina_�1YY I, I i� I _1 r QWQl� F - a �� 12" � 3 FALSE MUNTINS M.\K S� (SURFACE APPLIED) - I SILL �'>o 1 ,� o SILL o MAY BE USED �. `a �! o f o 1 0 32 11/16" �� V� 32 11/16" 32 11/16" 32 11/16 32 11/16" t 32 11/16" +4 D.L. OPG. D.L.OPG. D.L.OPG. `-TO.L OPG: D.L. OPG. 11 O.L.OPG. v J~ F'-_- 36 9/16" r'I (3}ANCHORS 36 9/16" t�l (3)ANCHORS 36 9/16` I1 (3)ANCHORS J W VENT WIDTH -AT MTG.STILE ENDS VEM WIDTH SAT MTG.STILE ENDS VENT WIDTH L-AT MTG.STILE ENDS N,AT 5"O.C. AT S"O.C. AT 5"O.C. 5E OI n TYPICAL ELEVATION TYPICAL ELEVATION TYPICAL ELEVATION o pan m FLANGE FRAMES FLANGE FRAMES WITH FLUSH ADAPTER FLANGE FRAMES WITH FIN ADAPTER rn w �'QR SHUTTERS ARE NOT REQUIRED. - -- MAXIMUM DESIGN LOAD RATING =+ 65.0 PSF N ~ La THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. - ::.0 PSF B (FOR SIZES SHOWN ABOVE OR SMALLER) MTG. STILES WITHOUT REINFORCING ES-EL200 s'll HORIZONTAL ROLLING ALUMINUM WINDOW (L.M.I.) I MAXIMUM DESIGN LOAD RATING =+ 80.0 PSF(FOR SIZES SHOWN ABOVE OR SMALLER) - 90.0 PSF 0 APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE y - i.. ...../ -- COMBINATIONS OF H.R. H.R. OR HORIZONTAL ROLLING WITH REQUIREMENTS OF THE 2017 (6 H EDITION)/2020 L7TH EDITION) FLORIDA o d / I MTG. STILES WITH REINFORCING OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS ( ) L_----����� ����-���`---'-�-""-���--�-� - � ��5 '. BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE HVHZ. ..._.._. ��i USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. 1BY OR 26Y WOOD BUCKS& BUCK FASTENERS BY OTHERS, MUST BE OPERATING VENTS CAN BE / 4 TO 113 OF WINDOW WIDTH � ! LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION NOA WILL DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS MAX.D.L.OPG. FOR FIXED LITE NOT TO EXCEED 12.7 SO. Fr. APPLY TO ENTIRE SYSTEM. TO THE BUILDING STRUCTURE. nl FOR ALTERNATE SIZE UNITS MAX. FRAME AREA OF WINDOW ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS NOT TO EXCEED TESTED FRAME AREA OF 31.46 SO.FT. d_C_ AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIRED EMBEDMENT TO BASE o_c MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. PRODUCT REVISED '> $ A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. as complying with the Florida Building Code \\\\ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON-COMPRESSIBLE- -No. 20-1208.07 ......... MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS,THAT Expiration Date• 11/9/2022 �'V COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE &ADOPTED STANDARDS. By: +au'' No.r?i22 THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION Mlamj-0ade Producr trot FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT,ADEQUACY I} '(�i f $ S o OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR (] € itl.J WATER INFILTRATION RESISTANCE ETC. Ca ST OF �„' drawing no. AND TOBE SHOWN IN THIS DRAWING BUILDING OFFICIAL E TO BE ANALYZED SEPARATELY, \ v.FZORIOP �, W16-86 DESIGN LOADS SHOWN ARE BASED ON 'ALLOWABLE STRESS DESIGN (ASD)'. \`£�/.aif j� j� ;t� sheet 1 of 11) _ �iw FRAME WIDTH - FRAME WIDTH-___ �� (3)ANCHORS (3)ANCHORS t�M (p� AT MTG.STILE ENDS- AT MTG.STILE ENDS 7"MAX. / 19"MAX. 7"MAX. 19"MAX. AT5"0.6i AT 5'O.C. �3 HEAD/SILL I /A� _ 4 _ HEAD HEAD/SILL �j __ HEAD Z CORNERS , °7 -��� 4 CORNERS 7i Q Z g m I Q r i • I a i O o 0 d" FF a/ E'�, o^��� I rrW \tia ✓E7 , -- ❑II�II `j��--rI�IIIItIII-Fr--fi O Tr QCQ7,po 4 2 IT- I L =>� 4 W- jO Nw>b Z yht a WWEWI- t- FALSE MUNTINS / B t/� p (SURFACE APPLIED)--' 4 MAXz , 111 ! "==-... z 3 v`> MAY BE USED SILL s SILL -sic, o m 32 11/16' 32 11 16" 32 11/16" 32 11 16 32 11 16" 32 11 16" o j / (3)ANCHORS (3)ANCHORS / / L.._ / a D.L.OPG. D.L OPG. D.L. OPG. AT MTG.STILE ENDS D.L OPG. -L. OPG. I' v C.L.CPG. AT MTG.STILE ENDS _ AT S"O.C. AT 5'O.C. 36 9/16' 36 9/16' 36 9 16" J VENT WIDTH VENT WIDTH VENT WIDTH VENT WIDTH J w u TYPICAL ELEVATION TYPICAL ELEVATION FLANGE FRAMES ___ ___ 110" FLANGE FRAMES WITH FLUSH ADAPTER FRAME WIDTH (3)ANCHORS _ rt C3 M m l 6"MAX. AT MTG.STILE ENDS-ry 12 J HEAD/SILL i AT 5'O.C. I1 t �_ CORNERS N ti Ilal n a - MAXIMUM DESIGN LOAD RATING =+ 65.0 PSF (FOR SIZES SHOWN ABOVE OR SMALLER) — 65.0 PSF I -T, F r - I f MTG. STILES WITHOUT REINFORCING.......... ... �� W MAXIMUM DESIGN LOAD RATING =+ 80.0 PSF `o '�W _ p II�II II �I FOR SIZES SHOWN ABOVE OR SMALLER - 90.0 PSF7. x r II ( ) _ i _.y-_.. I'I In MTG. STILES WITH REINFORCING OPERATING VENTS CAN BE 1/4 TO 1/3 OF WINDOW WIDTH_J it II j it II — MAX.D.L.OPG.FOR FIXED LITE NOT TO EXCEED 12.7 SO.FT. 'Tr---T- FOR ALTERNATE SIZE UNITS MAX.FRAME AREA OF WINDOW ^m N q moo`-ri.N NOT TO EXCEED TESTED FRAME AREA OF 47.36 S0.FL PRODUCT REVISED -� 'oSo complying with the Florida 111111 I1 f It <m o m - - ° BuildingCode q 12 lm NOA-No. 20-1208.07 �������'-• � m��c I s MAx. o z Expiragtion Date j 11912022 SILL j Q By: 'flay tA, No BUZ3 `= (3)ANCHORS S32 11/16' 32 11/76' 32 11/16' MIam,FDade P-ducrC trot AT MTG.STILE ENDS-�� D.L GPO. O.L. OFG. D.L. OPG. ,r y q AT 5"O.C." j DEC 0 1 2�; �� ( ••��/ �� SIX 36 9/16" y 36 9/16" ��� '•. TE OF • 1{S�; drawing no. c 1 VENT WIDTH VENT WIDTH t%C FZORIDF`. -86ji TYPICAL ELEVATION FLANGE FRAMES WITH FIN ADAPTER ��17fI11111t1 sheet 2 of 11J - Zh 0 0� n� azl H w ro I m o 0 W o`0l0 N 1/8"TEMP. GLASS C 1/8"TEMP. GLASS O 8 w m AIR SPACE 1, I--S/16"AIR SPACE O a j M ( I m o' f-1/8"HEAT STREN'D.GLASS 1/8"HEAT STREN'D. GLASS I1 ,� �1/8'HEAT STREN'D.GLASS ,�11 1 71/8" HEAT STREN'D,GLASS O CL a 0 Lot 090'IMerlayer 090"Intedayer I ' 090"Intedayer , ' 090'Intedayer 0 m H¢ { Trosifol PVB 1, Trosifol PVB ' 1 Trosifol PVB I Trosifol PVB ¢Z O a ' By'Kureray America.Inc.' '` By'Kuroroy Americo.Inc.' , i 1 By'Kuraray Americo, Inc.* ` �I ! By'Kureray America,Inc.' Q w: Z e OR 1 OR �, 1 I OR 1 II OR LL Z 0 2 o 090'Intedayer .090'Intedayer ` .090'Intedayer 090'Intedayer j 005 - SentryGlos SentryGlas t ' I SentryGlas , 1 I SentryGlas Q W aml E 1 By'Kuroroy Americo,Inc.' t By'Kureray America, Inc.' l { By'Kureray America, Inc.' �l V By'Kuroroy America,Inc.' OR 1 OR 1 I ri—OR 1 � � �OR ` 090"Intarlayer O90"Intedayer ` it I .090"Intedayer I I 090"Intedayer Saflex Clear And Color Glass Saflex Clear And Color Glass I Saflex Clear And Color Glass 1 Saflex Clear And Color Glass By 'Eastman Chemical Co_' , By'Eastman Chemical Co.' ,, II I By'Eastman Chemical Co.' , ' I By 'Eastman Chemical Co.' OR 1 OR l I I �I OR 1� V OR -075'lnterlayer t 075"Interayer 1 i4 ,. V 075'Interayer 1 II 075'Intedoyer Safi"CP With PET Core 1 Saflex CP With PET Core ` �i Saflex CP With PET Care 1 Saflex CP With PET Core I By 'Eastman Chemical Co.' �` By'Eastman Chemical Co.' I By'Eastman Chemical Co.' By 'Eastman Chemical Co.' _ `a 1 1/8"HEAT STREN'D.GLASS ' 1/4'HEAT STREN'D. GLASS 14 1/8"HEAT STREN'D.GLASS ` ' I-1/4"HEAT STREN'D.GLASS = 1 V SILICONE ` SILICONE SILICONE ,r I I SILICONE J Z DOWSIL 795 ',,,m 1 DOWSIL 795 F V ' DOWSIL 795 �t I I DOWSIL 795 J w �DOWSIL 983 IC DOWSIL 983 4 I'I --DOWSIL 983 t I I I ,-DONfSIL 983 z m 1 DOWSIL 2400 z'm , DOWSIL 2400 i m I I; DOWSIL 2400 z m �' DOWSIL 2400 ¢ C a (HOT MELT) '^ (HOT MELT) a to (HOT MELT) �' ! (HOT MELT) N M1 II Ir N� I CI) J' N Ml 4 � � iv M7 I I j 30 Co re)n I I w vi n_ E9 � z �� E11 1_1 ¢ E11e Is w LJ r9 w M2 W M2 Q W ' GLASS TYPE `I' GLASS T)TE_'2' GLASS TYPE 'li' GLASS TYPId'2i' WIC S 5/16"OVERALL LAM.GLASS 7/16"OVERALL LAM. GLASS 7/8"OVERALL INSUL LAM. GLASS 7/8"OVERALL INSUL LAM.CLASS ('I" o� !o or GLAZING OPTIONS W 6 s I= cm=-- oo PRODUCT REVISED g as complying with the Florida 11 U t 1 d o<m m Buildi NOA'No.Gode 20-120&07 j/���V\���•...��. ', '/ , �c a �, 3/8" AIR SPACE CONSISTING OF: Expiration Date• 1119/2022 ,�`' •`uSF�••.' e,j ,p I o SPACER: 23 '�\ Dy: LLf'✓ r No A i HEUMA' LOW PROFILE ALUMINUM SPACER - NOTE- BY 'LINGERMANN GMBH' MIam:Dade Produc,YC trot GLASS CAPACITIES ARE AROUND THE PERIMETER OF THE GLASS. Ll ° YK BASED ON ASTM E1300-09 (3 SEC. GUSTS) PERIMETER SEALANT: \ sraarcr` •1�i�l drawing9 no. AND FLORIDA BUILDING COMMISSION SILICONE ���ay s•.2omoP:•r���.. W1 6—$6 DECLARATORY STATEMENT DCA05—DEC-219 DOWSIL sheet 3 off 11J m 1- 1 /8" HEAT STREN'D. GLASS l 1/8" HEAT STREN'D. GLASS •- 3/i6" HEAT STREN'D, GLASS 1 3/16" HEAT STREN'D. GLASS J tic 090" Interayer .090" Interlayer 090" Interlayer t 090" Interlayer •II SentryGlos SeMryGlos .-- SentryGlas r— SeMryGlas Q F n By 'Kuraray America, Inc. ' � By 'Kuraray America, Inc. I By ' Kuraray America, Inc. tl By Kuraray America, Inc.' wIm m a: �II it t /4" HEAT STREN'D. GLASS 0: 1 /4" HEAT STREN'D. GLASS a: II - 3/16" HEAT STREN'D, GLASS I I 3/76" HEAT STREN'D. GLASSIt a a < n o m ` _ SNCONE m I SILICONE m I r SILICONE m SILICONE > N DOWSIL 795 DOWSIL 795 z ut n T = m DOWSIL 795 z Iu, DOWSIL 795 d w �MiA tl L1 ' . II MIA I : r x cc c t H m n it ari a ¢ em o 1 I 0ILQ< j x i• 1 x o• _ z OMen00 i J � � V � � z ° o '� / _o � '� 1 ° k o n f N w LE10 , ` / i t w iEI0 w �7011.1 r j Q w Y�l a- c r -M3� AT 1 /4 POINTS ON UTES j1 AT 1/4 POINTS ON LITES w �' M3 } AT 1/4 POINTS ON UTES `� r/�� M3'� AT 1/4 POINTS ON UTES Z 0 f WIDER THAN 36" ONLY `/ WIDER THAN 3V ONLY � WIDER THAN 36" ONLY `/ WIDER THAN 36" ONLY J D m < J aW1 € GLASS TYPE '2A GLASS TYPE 13' 7/16" OVERALL LAM, GLASS 7/16" OVERALL LAM. GLASS o to 3 m 1 1 /4" TEMP. GLASS m 1� -- 5/16" AIR SPACE �f 1 /8" HEAT STREN'D. GLASS :3 J ` 0 09 " Interlayer --I W LL TIx Tsifol PVB N II By Kuraray Americo. Inc.' a � 3 ( OR N 0 � M l 090" Interlayer rt n `1- 1 /8" TEMP. GLASS I I By ' KGlas = Z 3 J e By Americo. Inc.'AIL r 5/16" AIR SPACE 0" Interlayer $ 3 Z .09 0 = n — 1 /8" HEAT STREN'D. GLASS Soflex Clear And Color Glass w ¢ J 11 II 'I } I � By 'Eastman Chemical Co.' w WO g I. 090" Interia r I' Ye `1 II I 075" Interlayer SentryGlos I Soflex CP With PET Core SILICONE 1 I By 'Kuraray America, Inc.' SILICONE ` I I By 'Eastman Chemical Co.' ', DOWSIL 791 � I I DOWSIL 791 - (1/8" X 1 /4") �. � r-- 1 /4" HS. GLASS (1 j8" X 1/16") II f- 1 /8" HS. GLASS 5/16" AIR SPACE CONSISTING OF: a SPACER: � II i I SILICONE Iw �kI SILICONE Q 6 F m \, It 1 I DOWSIL 795 i I TDOWSIL 795 ' HELIMA' LOW PROFILE ALUMINUM SPACER z i, I z \. I / BY ' LINGERMANN GMBH' U s M1e `, I s Mt6 ' I ) AROUND THE PERIMETER OF THE GLASS. v J II � cis PERIMETER SEALANT: v �� iI ) SILICONE � i ) r ` •1 DOWSIL 791tee • • I GE 2000 C e PRODUCT REVISED >j o 4 o Yi as complying with the Florida 11111 1 t i f r f m l c n: i t 11 Building Code `t� y!/ w ti/ AT 1 /4 POINTS �� AT 1/4 POINTS NOMNo. 20-1208"07 � �°"-• '/r ALL SIZES M4 ALL SIZES Expiration Date• 1 /19/2022 �` ��' UC� �'•. r q GLASS TYPE '2Ai' GLASS TYPE '4i' ey ?%�� '1-�At2 — o. e1223 I` 7/8" OVERALL INSUL, LAM, GLASS 7/8" OVERALL INSUL LAM, GLASS MlamhDade ProducXIC trot ylxo MAXIMUM DESIGN LOADS FOR GLASS TYPE '4i' �NOT TO EXCEED t80.0 PSF D 1 �-- s drawing no. i GLAZING OPTIONS [ sheet3. tof 11 ] TYPICAL ANCHORS C WOOD BUK SEE ELEV. w V w 1f }I 1 !_�-FOR SPACING EDGE GIST. c ° i EDGE DIST. � � TYPICAL ANCHORS _ ° n f m ---- ''j( SEE ELEY.—�. C 4 _ � z FOR SPACING f z Z o� aiN I iN\ � y ter ¢ _ N El I P. (Et4 M44 �' O - - � 0 M j1 _ M5 ) M r �MI41 O � m o 1 ( El71 Ms' a '. '- 0 a a Q It E71mm0 M Z J n � OPTIONAL TO O S ,MHO} C � � ii II � 1 r SWEEP LATCH J 2 rc I I I� I i i� II II li ( c ' t;:1 W I� = l c J W o O o� c� O O � ) IX M —�I 01 Z_ : x .„ _. Z o I� 0_ Q = Z � J m_ Mtal 0 3 z ` o n - MS OPTIONAL TO (Jj � SPRING LATCH I j � jN � l I � � j4EEPH0I,E5 : J ( � 1mil1 W1 = 1 - 1 /2" X 5/16" WEEPHOLES AT 5- 1 /2" FROM o +� �_' i .�..._y 00 EACH END E7 m z _ I I I � I � . � 6 _ ' (M17 - IM 3i M12) ��. i u -� fs PRODUCT REVISED i ; g �+ — E3 as complyingwith the Florida 1 Y ill Buildin oe �9 M9 i NOA-No. 20-'1208.07 Expiration Date• 7h1912022 ylla ° �g5 r gy_•���LZfff '� !; Pb Eie.2. i EDGE DIST ° - " I� MIamF-Dade ProducrC trot a 'Q Ih Wt — � FOR WINDOWS WITHOUT y� 77 v El RISER LIMIT MAX. U ' 1i 1 �� _ _ �� •• TYPICAL ANCHOR6 / " EXT.(+) LOADS TO 65.0 PSF `� ST CIS- ' Id/ drawing o no. Wt / : I. TYPICAL ANCHORS r•= FOR WINDOWS WITHOUT - - SEE ELEv ,_1BY \ SEE ELEV. '-+E15}SILL RISER LIMIT MAX. FOR SPACING —i WOOD BUCK `�� ., O�OA• `��,- W16- 86 FOR SPACING ✓ EXT.(+) LOADS TO 66.0 PSF DIST. , sheet 4 of 11 � — METAL 1111-MIPMI-DADE---- COUNTY----APPRO--VED II � STRUCTURE jl MULLION&MULLION ANCHORS Ij EDGE DIST. 11 SEE SEPARATE NOA Z n i� 1 EDGE I------ -------_�.1 O e ip 10�1 lV O�w� voW" t 1 a0 a' ` TYPICAL ANCHORS ` TYPICAL ANCHORS O G 0 G -SEE ELEV. —SEE ELEV. O 4 t FOR SPACING FOR SPACING In m p m Q W 7 1�1. LL WIn U. (7 m< J �IQwMM g N J m Q p (' YJ U� WOOD BUCKS AND METAL STRUCTURE NOT BY 'E.S. WINDOWS' �- MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM IX AND TRANSFER THEM TO THE BUILDING STRUCTURE IN .—._.__.. ._..._.._.__...._..._.._.____.__..—_.._ N Q m"N K C, M m x Z3 2 TYPICAL ANCHORS- SEE ELEV. FOR SPACING o 3 Z w 1/4' DIA UILTRACON+ BY 'DEWALT' (Fu=1e4 KSI.Fy=14e KSI) w N u)Q INTO 2BY WOOD BUCKS OR WOOD STRUCTURES W W n 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) _ -- THRU 1BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) Q15 DIRECTLY INTO CONCRETE OR BLOCKS 1 cl I$ 1-1/2" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) o 01 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) U 1/4' DIA TEKS OR SELF DRILLING SCREWS (GRADE 5 CRS) �i 'c'o' INTO MIAMI-DADE COUNTY APPROVED MULLIONS 't i OR oo� INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE w PRODUCT REVISED ALUMINUM: 1/8"THK. MIN. (6063-T5 MIN.) as complying with the Florida d STEEL: 1/5" THK. MIN. (Fy = 36 KSI MIN.) Building code LLl l7ttttl� 'i (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) NOA-No. 20-1208. 17 f���y�. E Expiration Date j•-0 119/2022 TYPICAL EDGE DISTANC tt� LICENSE a';) INTO CONCRETE AND MASONRY = 2-1/2" MIN. ey.�J�Y�"CZK�i2 h N�,612t3l-- INTO WOOD STRUCTURE = 1" MIN. MIam�Dade Produc�t'Cc�trol INTO METAL STRUCTURE = 3/4" MIN. DEC 0 j zTEp drawing no.- WOOD AT HEAD.SILL OR JAMBS SG= 0.55 MIN. ^.."(pRIpP CONCRETE AT HEAD,SILL OR JAMBS f'c - 3000 PSI MIN. W1 6-86 C-90 HOLLOW/FILLED BLOCK AT JAMBS fm - 2000 PSI MIN. \�,i ONAL��e (sheet 5 of 71' W, i E) F,'' --�REINFORCING �' M14M1-DADE COUNTY /A('76JAS REDD. 1/4^MAX APPROVED MULLION ON tV 1/4"MAX. ...._.. __ VENT WIDTH _------ - SEE ELEVS. SHIMS �� � ---, !� SEE SEPARATE NOA SHIM _\ ^• �-- M7611 E4 MS TYPICAL ANCHORS -_ m �E6) ES)iM16I M81 iEt B1 (Ea.ti I�SEE Eby, i� -'I "'C _ .+ FOR SPACING 1 __ 2 TYPICAL ANCHORS A I 1 Q a SEE ELEV. a J _ _ - f i I �`O 1, 0 L)i. 1 FOR SPACING IL m N IEOat �a0d, it �.m Z0.I n 51, ' �. -----� —�.. . I.�• wif TYPICAL ANCHORS J M76� iNIS Gnsr EXTERIOR Eta) MsjfMnl e� --SEE ELEv_ METAL J k` STRUCTURE U I L OPC. II d� FOR SPACING = WOOD BUCKS) WINDOW WIDTH WINDOW WIDTH j WINDOW WIDTH 3 '� XO LAYOUT ro OX OPPOSITE C(E) {F) L 1/4"MAX. VENT WIDTH "� i ANCHORS 3 - _.. .............. MT M TYPICAL Z SHIM ---- I 1 61 1 4 --SEE ELEV. 0 rn MI6 E4 MS E6I r �~ �` REINFORCING DIY Sj{IMS FOR SPACING �;ES)'M16f 'MI6 (M61 E76ASEDD, M7 .V SEE ELEVS. Ed G z�o 1 jz' I-- M w w � I m V If O m� 1 �_ W �Q LM161IM5)=M,ii) 1 EXTERIOR i E91 1Eiii O.L OPG WOOD BUCKS —�- I WINDOW WIDTH PRODUCT REVISED a' AA NG OE $OX L.4YOU'� Building as C TYPICAL ode L-SEE ELFFOR with the Florida ^!t NOA-No. 20-1208.07 Ex Iration Date• 1f1 j 22 ;� � u0 •'• m ° 4 11 B�'��� No 91223 N � MIam_pade ProducY'Cy trol DEC 0 ��•`•• � � drawing no. ��'•:F�O�t�v� ��� W16 86 _ .. . EDGE DIST. to MIAMI-DADE COUNTY APPROVED tO ! _ EDGE DIST. � MMETALTURE MULLION & MUWON ANCHORS m m j SEE SEPARATE NOA I Z 0 t < G EDGE DIST__ /. F w ZE No I ai Opap 0l N m i N E � IAA 1 ET2 jy V E12 ALT. C � LE u1 i 1 TYPICAL ANCHORS TYPICAL ANCHORS TYPICAL ANCHORS Ir Z O N — SEE ELEV. LSEE ELF/. I SEE ELEV. Q w 3 w � j FOR SPACING FOR SPACING FOR SPACING IL Z H — w l JamaJ Qu� mf � 3 1 6 R U xx ~ LL J W Li III O N n 1/4" MAX ( E,I 0 3 ,c 3 W SHIMS �� 047) n g >C TYPICAL ANCHORS T ALT. x Z 3 J m W SEE ELEV. -\ a 3 Z U- a FOR SPACING LO < w Uj k sl Tfe oI' 4 n w � W TYPICAL ANCHORS r— SEE ELEV. FOR SPACING l I - _......._ WINDOW WIDTH ( B N o $ Z ALT• PRODUCT REVISED •> S as complying with the Florida �.�l`,,1{ I I f, l\� d 0 < m o I _ Building Code .���� �. /i�i` •— m _J NOA-No. 20A208.07 INSTALLATION DETAILS WITH FLUSH FRAME ADAPTER �) _ Expiration Date: •1H9/2022 _ SEE SHEETS 4 & 6 FOR WINDOW DETAILS By: i MlamFpade Produ�yc,YC gqtrot ,../EC 0 1 itl i r § '� �� 1 , l_, JL. P S'FA ECG drawing no. l W16 -86 EDGE DIST. i11 ` Y : sheet 7 ofl1i V w TYPICAL ANCHORSAll , { m ILLUSTRATIVE OTLS. ONLY SEE SPAC �t FOR SPACING Z EXT. OR MT. FINISHES NOT 8Y E.S. WSW. ? b o ( i \ I- oa @ `¢ 3 TYPICAL. ANCHORS: SEE ELEV. FOR SPACING 1" � Z m ( a 3 : i da � m $ i -- Q WOOD SCREWS (GRADE 2 CRS) O m -� INTO 2BY WOOD BUCKS OR WOOD STRUCTURES p, " - 1 _ 1 �2" MIN. PENETRATION INTO WOOD .........—_...___._. - a a, 0puFT4 � t, E13 p aaa 8 IO � G� rc ALT. t I fY ¢ 2 a a Q W a Ill g 1 # 10 TEKS/SELF DRILLING SCREWS W to _ o AT 6 FROM ENDS J Z,WWO < w AND 12 O.C. MAX. Q W Or E r w 1/4' MAX. v j � m 1 /20 MIN, J 1If Q O U J � W z0 ` II t ALT. N 3Ovw- Q n H g Z www 31 w 1 Lo g 1 #10 TEKS/SELF DRILLING SCREWS w w M � r AT 6 FROM ENDS AND 12 O.C. MAX. I I - I #10 TEKS/SELF DRILLING SCREWS TYPICAL ANCHORS EXTERIOR www AT 6 FROM ENDS ~SEE ELEVwmwJ . J AND 12 O.C. MAX- FOR SPACING �3+ 1 WINDOW WIDTH gib z ijo rj Cio ~r � of rH v1 PRODUCT REVISED jwm S ALt. as complying with the Florida `11111 I I I I II/r .� c u � Building Code ` V1 a qb- .-. �.�, s�! ,, ii ` ' W �� Yi NOA-No. 20-1208.07 /�� � 10EN ' INSTALLATION DETAILS WITH FIN FRAIfF 4DAPTEI2 Expiration Date 111912U22 �a 1ww SEE SHEETS 4 & 6 FOR WINDOW DETAILS By�y,� yfr _ p�� _ w- V � n MIam,FDade ProdugYCa�trol Ll`Z : _ s If � � �EC011 � � //.�' � a � � I `� Fl leSTATEOr der drowing no. low of TYPICAL ANCHORS �. �+ �° . 6 1-- SEE ELEV. h 77�11Ai11 �1 (sheet 8 of 11i FOR SPACING 1T1iM / PART B ! READ. .. DESCRIPTION MATERIAL MANF./SUPPLTER/REMARKS E1 ES-EL104 1 1 FRAME HEAD 6063-TS1-7 von E2 ES-EL201 I 1 FRAIAE SILL 6063-T6 E3 ES-EL202 i SILL TRACK _' _6063 T6 - ( O f H m W E4 ES-EL102 2 FRAME JAMB (OPERATING) �- 6063-T6 - ( F W ro I E4 1 - ^ ES=EL101A 2i FRAME JAMB (flXEO) 6063-T6 - Q a eono ES ES-EL105 1 INTERLOCK STILE 6063-T6 - Q W O � w ! � -j-.-- tV ., E6 ES-EL106 1 ) JAMB STILE 6063-T6 on a > N E7 ES-EL107 2 VENT TOP & BOTTOM RAIL 6063-T6 E8 ES-EL1 G8A 1 FIXED MTG. STILE 6063-T6 E9 ES-EL109 AS ROD. GLAZING BEAD (5/16" LAM. CLASS) 6063-T6 - M E10 ES-ELI 10 AS ROD. I GLAZING BEAD (7/16" LAM. GLASS) --� — 6063-76 _ - 0 a O C g El OA ES-EL123 i AS ROD, ' GLAZING BEAD (7/16' LAM. GLASS)_ 6063-T6 ony�j H Q AS ROD, GLAZING BEAD (INSUL LAM. GLASS) 6063A,76 E12 ..._ a_VES ELt 72v.` AS EQD. FLUSHGF BEAD RAME (I SULK LAM. GLASS) __..._....—' -- 6063-T6 ._...�. - ^ nor _ to a o 4wmfR" I E13 ES-EL115 AS READ, FLUSH FRAME ADAPTER WITH FIN 6063-T5 - �- E14 ES-EL114 AS REDD, HEAD SCREW COVER 6063-T6 - E15 ES-2011 AS REGD, SILL RISER 6063-T6 - n E76 ES-EL220 AS READ. „ INTERLOCK STILE STIFFENER 6005-75 - E17 ES-EL221 AS READ. ! FIX. MTG. STILE STIFFENER 6005-75 - S EIS ES-EL113A AS REQO, JAMB SCREW COVER �^ 6063-T6 on M1 ES-5008A AS READ. GLAZING BEAD BULB SILICONE DUROMETER 60±5 SHORE A z O MIA EL100-G02 AS READ, EXTERIOR LEAF GASKET SILICONE DUROMETER 60±5 SHORE A J Jw MIS ES-H-340-G05 AS REDD. EXTERIOR WEDGE GASKET SILICONE DUROMETER 65t5 SHORE Aon I � � M2- 80-372A 2/ LITE SETTING BLOCK AT 1/4 POINTS (LAM. GLASS) SILICONE DUROMETER 80±5 SHORE A _ Z 3 N �t 0 Nnn M3 EU00-BOt 2/ LITE SETTING BLOCK AT 1/4 POINTS (INSUL LAM. GLASS) SILICONE DUROMETER 8035 SHORE A - O qt M I M4 EL100-301 AS READ. VENT STOP RIGID PVC - _ O = Z3jm M5 W23211 NG AS REDD, PILE W STRIPPING WITH PLASTIC FIN POLYPROPYLENE - g 3 Z LL M6 SK08-4010 2/ VENT SPRING LOADED LATCH 6063-T6 ALTERNATE TO SWEEP LATCH cof O N n M7 ES-1012 2/ LATCH LATCH SPRING ST. STEEL - _ U,j M r M8 SL302-XX 2/ VENT SWEEP LATCH DIE CAST ALUM M9 WA2L _- 2 WEEP HOLE COVER RIGID PVC M10 ES-1000-PIL - LEFT NOTCH CAP NYLON li MIT ES-1000-PlR - RIGHT NOTCH CAP _.._ NYLON no W G M12 WPSA-N1 2 3/4" X 3/4" RETIC FOAM PAD FOAM- M13 TAR-16019P-A 2 ) ROLLER POLYAMIOE & ACE TAL on ._.._........ M14 TAR-16019P 2 TROLLER HOUSING POLYAMIDE - M15B X 1 " - T SH FRAME ADAPTER ASSEMBLY FASTENERS ST, S FH SMS MI6 #8 X 1 " on ! FRAME AND VENT ASSEMBLY FASTENERS ST, STEEL I PH SMS M17 �#8 X 3" 9- ASSEmBLY FRAME SILL ASSEMBLY FASTENERS ^� - ST. STEEL j PH SMS 0 j M18 d8 X 3/4' SWEEP LATCH FASTENERS _ ST� FH SMS , � jy no wn , wo M20 #14 X 3/4" FASTENERS FOR FLUSH ADAPTER ST. STEEL PH SMS o-° !L . PRODUCT REVISED $ as complying with the Florida `Xt y 1I I' f�f jc Building Code /.\ NOA-No. 204205.07 �no no � ExRir ittion Date• 111912022 1�' ��` V SF 'T + g ey: ' Yl�ff/ inon v`- . PIo. BI223 lo, r -r'- MiamF-Dade Produc,YCg6trol / '1.'r ? : �+' T _on a b c DEC 0 120 W16 -86 sheet 9 of 1 1 ; 519 50 10 b......._.- : . f--- 1 .313 --"� TYP. .25 -P,' ' .625 62 .625 .25 �. 2917 ----- -- 631 519 -t• -y t35 of 057 m 1050 j �^ .050 .974 -- .050 .974 y__ .974 �. .062 .974 �_ .062 ,974 I Z m ' ymlZ 2-1157 -osz ' •295 z.3a7 ---{ - ( -� ----� ----�- -------�- p m Q . 2.t312 TIP, I 1 .187 --I ��- .202 - F- .z02 -41 _ .zoz .zoz -� zoz Q 2 Z « 12 -- �. ,--. C c �E9 ( • 10� iEt OAi I E11 ) (E17A{ Q �. I�__.. I '�� `-•- �._/ GLAZING BEADS J a G to 1 .187 1 . 187 1 .163 -^1 1 .122 C L JAMB STILE �' -( Q a �Eil1 FRAME HEAD •�3 .188 .125 1 -025 0 1 an .. .... 1 .938 -^1' �- .062 1 .308 1 .078 .078 1 .421 Q w z a 1 .050 - 1 .260J Q w Oi f t J -062 r�.. (E161 INTERLOCK STILE STIFFENER t 6) SPRING LOADED LATCH .02 1 .187 t .�7a ( E7i VENT TOP/BOTTOM RAIL T'P. m .571 3 3.310 2. 1 � 3 2.685 k- - 1 .313 .040 g 'O 1 .I40 1 '33 ' 125 1 .013 !L J p (� INTERLOCK STILE c� I 1 .826 J w Pr ,E17j FIX. MTG. STILE STIFFENER v `%>:2` FRAME SILL II (LC �'J� (t18) JAMB SCREW COVER N 30 w n m I.LJ _.___1 .165 O p 1 .407 1 .187 r_040 i .068 � .062 8 (/1 iO < v .D62 v� lil iLO n g r .250 � b-- 1 .374 .25 2.000 F�- 1 .387 046 -�I 1 lEtij HEAD SCREW COVER (E3 `I SILL TRACK (ES} FIXED MTG. STILE -- 2.a57 --� \ .OaS 1E15! SILL RISER Ic s ' - 2,814 -a .500 .625 j .719 tom- 2.780 062 (Et ?I FLUSH FRAME ADAPTER aIQ TIP. PRODUCT REVISED ° G, Z ! a1 - 1 .428 as complying with the Florida \ 11l f I 11I � .062 Building Code / \\ f/ 2.917 3,141 2.977 2.987 ice\ y F 7 Iv.. NOA-No. 20-1208.07 /�� _ Q , 6�ii m 1 O50 1 .500 .063 Expiration Date: 1 /1 9120 22 VGFIV3F '.� N �I TYP. 1 .167 B .•11i!U i� I=_ _ ___... ..%L-L -r M amFDade Pr�odu •� A ^trol / o a ICI d 33.. .875 .625 .500 _85 DEC Q 1 !ftf� '- t. ' - _ \� "P? '• S' 'T'fOd�. `!A ". drawing no. .639 i--- 1 .562 -q 2,780 �E4j FRAME JAMB (OPERATING) E4_l FRAME JAMB (FIXED) Et31 FLUSH FRAME ADAPTER WITH FIN r =`i, rll�y% sheetT0of111 W pp t0 / a n2 a CL C 6 - W = gy o > m 0 IL a 0w � 0 z sag all FLUSH FRAME ADAPTER CORNER m N & BOTTOM CORNER FRAME TOP CORNE VENT TOPR m a UI v � W W cc i o pdM x Z3 � e g 3z ^ � , o I � I O _ M wINN M H N - i o }Q }Q r cc u u 1 �1 I � f mi222o 5 FIN FRAME ADAPTER CORNER „ ' a o ^ g f g PRODUCT REVISED g 0 ' as complying with the Florida U I I I1 m e < o Bud Xding Code \ 0 % j0r FA NOA-No. 20-1208.07 � •. .� y'�,����, _ l o Expiration Date• 1 /19/2022 /:� a4 By:- t gW k P0 'VCEN3p' a ( � ) % N i I r j2 No. 61223 Mlam"ade Producit'Colmtrol LY 7 ou arC"F drowmg no. 1 FRAME BOTTOM CORNER v FtoatuP ��� W16 - 86J FIX, MTG, RAIL CORNER ; sheet 11 off 11