Loading...
HomeMy WebLinkAboutNOA FL17697.12 ProfessionalRegulation BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications I Contact Us BCIS Site Map Links I Search I Florida r I c Product Approval Ia"' USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL17697-R3 Application Type Affirmation Code Version 2020 Application Status Approved Comments Archived C Product Manufacturer Weather Shield Mfg.,Inc. Address/Phone/Email 829 N. 8th Street Medford,WI 54451 (715) 748-2100 Ext3932 val.bach@weathershield.com Authorized Signature Mark Brandner mark.brandner@weathershield.com Technical Representative Dale Turzinski Address/Phone/Email 829 N. 8th Medford,WI 54451 (715) 748-2100 Ext7842 dale.turzinski@weathershield.com Quality Assurance Representative Dale Turzinski Address/Phone/Email 829 N. 8th Medford,WI 54451 (715) 748-2100 Ext7842 dale.turzinski@weathershield.com Category Windows Subcategory Awning Compliance Method Certification Mark or Listing Certification Agency Window and Door Manufacturer Association Validated By Window and Door Manufacturers Association Referenced Standard and Year(of Standard) Standard Year AAMA 450-10 2010 AAMA/WDMA/CSA 101/I.S.2/A440-08 2008 AAMA/WDMA/CSA 101/I.S.2/A440-11 2011 ASTM E 1886 2005 ASTM E 1996 2012 ASTM E330-02 2010 TAS 201,TAS 202,TAS 203 1994 Equivalence of Product Standards Certified By I affirm that there are no changes in the new Florida Building Code which affect my product(s)and my product(s)are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes No N/A FL17697 R3 COC tb-equivilancy-memo nafs 201.pdf FL17697 R3 COC TB-Revised Equivalency ASTM .pdf Product Approval Method Method 1 Option A Date Submitted 12/29/2020 Date Validated 12/29/2020 Date Pending FBC Approval Date Approved 01/03/2021 Summary of Products FL# Model,Number or Name Description 17697.1 1209 Premium Awning Impact LC-PG65-AP 1054x902(4206) Window,Single Glazed Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17697 R3 C CAC 1209 Awning Windows(Report Approved for use outside HVHZ:Yes ESP019135P-1687)_pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +65/-85 05/21/2025 Other: 15/32"Cardinal "LG" laminated glass comprised of Installation Instructions (3/16")annealed/.090" PVB/(3/16")annealed glass.The FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and glass was set from the interior against silicone back bedding. In Picture(fin)_pdf addition,a back bed of silicone was used in the glazing pocket. Verified By: Window and Door Manufacturer Association (Missile D,Wind Zone 4) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17697.2 1209 Premium Awning Window LC-PG55-AP 1511x1054(60x42) (Annealed Monolithic) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17697 R3 C CAC WH 1209 Awning 60-42(Annealed Approved for use outside HVHZ:Yes Monolithic)_(Report ESP01866913-1662).pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +55/-70 01/08/2025 Other: 7.9mm(5/16")annealed glass.The glass was set from Installation Instructions the interior against silicone back bedding. In addition,a back FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and bed of silicone was used in the glazing pocket. Picture(fin)_pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17697.3 1209 Twin Premium Impact Awning LC-PG55-MA 3035x2108(120x83) with Twin Premium Impact Picture Stacked Above, Single Glazed - Reinforced Vertical Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17697 R3 C CAC 1209 Twin Premium Impact Awning With Approved for use outside HVHZ:Yes Twin Premium Impact Picture Stacked Above,Single Glazed Impact Resistant:Yes (Report ESP018434P-1647).pdf Design Pressure: +55/-70 Quality Assurance Contract Expiration Date Other: 7/16"Cardinal laminated glass comprised of(3/16") 01/22/2025 annealed/ .090" PVB/(3/16")annealed glass.The glass was Installation Instructions set from the interior against silicone back bedding. In addition, FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and a back bed of silicone was used in the glazing pocket. (Missile Picture(mullion),pdf D,Wind Zone 4) Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17697.4 1209 Twin Premium Impact Awning LC-PG55-MA 3035x2108(120x83) with Twin Premium Impact Picture Stacked Above, Single Glazed - Unreinforced Horizontal Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL17697 R3 C CAC 1209 Twin Premium Impact Awning With Approved for use outside HVHZ: Yes Twin Premium Impact Picture Stacked Above,Single Glazed Impact Resistant:Yes (Report ESP018434P-1647)_p!f Design Pressure: +55/-70 Quality Assurance Contract Expiration Date Other: 7/16"Cardinal laminated glass comprised of(3/16") 01/22/2025 annealed/ .090" PVB/(3/16")annealed glass.The glass was Installation Instructions set from the interior against silicone back bedding. In addition, FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and a back bed of silicone was used in the glazing pocket. (Missile Picture(mullion)_pdf D,Wind Zone 4) Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17697.5 1209 Twin Premium Impact Awning LC-PG55-MA 3035x2108(120x83) with Twin Premium Impact Picture Stacked Above, Single Glazed, Horizontal Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17697 R3 C CAC 1209 Twin Premium Impact Awning With Approved for use outside HVHZ:Yes Twin Premium Impact Picture Stacked Above,Single Glazed Impact Resistant:Yes (Report ESP018434P-1647)_pdf Design Pressure: +55/-70 Quality Assurance Contract Expiration Date Other: 7/16"Cardinal laminated glass comprised of(3/16") 01/22/2025 annealed/ .090" PVB/(3/16")annealed glass.The glass was Installation Instructions set from the interior against silicone back bedding. In addition, FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and a back bed of silicone was used in the glazing pocket. (Missile Picture(clip)_pdf D,Wind Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(fin).pdf FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(jamb)_pdf FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Pi r (mullion)_pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17697.6 1209 Twin Premium Impact Awning LC-PG55-MA 3035x2108(120x83) with Twin Premium Impact Picture Stacked Above, Single Glazed, Vertical Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17697 R3 C CAC 1209 Twin Premium Impact Awning With Approved for use outside HVHZ:Yes Twin Premium Impact Picture Stacked Above,Single Glazed Impact Resistant:Yes (Report ESP01843413-1647)_pdf Design Pressure: +55/-70 Quality Assurance Contract Expiration Date Other: 7/16"Cardinal laminated glass comprised of(3/16") 01/22/2025 annealed/ .090" PVB/(3/16")annealed glass.The glass was Installation Instructions set from the interior against silicone back bedding. In addition, FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and a back bed of silicone was used in the glazing pocket. (Missile Picture(clip)_pdf D,Wind Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(fin).pdf R3 FL17697 II WS 1209, 1210,8211 Casement,Awning,and Picture(jamb)_pdf FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(mullion).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17697.7 1210 Premium Awning Impact LC-PG55-AP 1511x1054(60x42) Window, Dual Glazed Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL17697 R3 C CAC WH 1210 Awnings 60x42 (Report Approved for use outside HVHZ: Yes ESP018659P-1661)_pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +55/-70 12/31/2024 Other: 3/4"insulated glass comprised of 3.9mm (5/32") Installation Instructions annealed/6.3mm (1/4")Super Spacer/3.1mm (1/8")/ .090" FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and PVB/3.1mm (1/8")annealed glass.The glass was set from the Picture(fin)_pdf interior against silicone back bedding. In addition,a back bed Verified By: Window and Door Manufacturer Association of silicone was used in the glazing pocket. (Missile D,Wind Created by Independent Third Party: Zone 4) Evaluation Reports Created by Independent Third Party: 17697.8 1210 Premium Awning Impact LC-PG55-AP 1511x1054(60x42) Window, Dual Glazed Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17697 R3 C CAC WH 1210 Awnings 60x42(Report Approved for use outside HVHZ:Yes ESP01865913-1661),pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +55/-70 12/31/2024 Other: 1"insulated glass comprised of 3.9mm (5/32") Installation Instructions annealed/ 13mm(1/2") Endura Spacer/3.1mm (1/8")/.090" FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and PVB/3.1mm (1/8")annealed glass.The glass was set from the Picture(fin)_pdf interior against silicone back bedding. In addition,a back bed Verified By: Window and Door Manufacturer Association of silicone was used in the glazing pocket. (Missile D,Wind Created by Independent Third Party: Zone 4) Evaluation Reports Created by Independent Third Party: 17697.9 1210 Premium Impact Awning with LC-PG65-MA 1054x2873 (42x113) Premium Impact Picture Stacked Above, Dual Glazed - Horizontal Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17697 R3 C CAC 1210 Mulled Awning and Fixed Windows Approved for use outside HVHZ:Yes (Report ESP019136P-1688)_pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +65/-85 04/15/2025 Other: 3/4" insulated glass comprised of 3.9mm (5/32") Installation Instructions annealed/6.3mm (1/4")Super Spacer/3.1mm (1/8")/ .090" FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and PVB/3.1mm (1/8")annealed glass.The glass was set from the Picture(clip)_pdf interior against silicone back bedding. In addition,a back bed FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and of silicone was used in the glazing pocket. (Missile D,Wind Picture(fin).pdf Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(jamb)_pdf FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(mullion),pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17697.10 1210 Premium Impact Awning with LC-PG65-MA 1054x2873(42x113) Premium Impact Picture Stacked Above, Dual Glazed - Mulled Combination Assembly Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17697 R3 C CAC 1210 Mulled Awning and Fixed Windows Approved for use outside HVHZ:Yes (Report ESP01913613-1688)_pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +65/-85 04/15/2025 Other: 3/4"insulated glass comprised of 3.9mm (5/32") Installation Instructions annealed/6.3mm (1/4")Super Spacer/3.1mm (1/8")/ .090" FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and PVB/3.1mm (1/8")annealed glass.The glass was set from the Picture(clip)_pdf interior against silicone back bedding. In addition,a back bed FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and of silicone was used in the glazing pocket. (Missile D,Wind Picture(fin)_pdf Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(jamb)_pdf FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(mullion),pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17697.11 1210 Premium Impact Awning with LC-PG65-MA 1054x2873 (42x113) Premium Impact Picture Stacked Above, Dual Glazed - Mulled Combination Assembly Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17697 R3 C CAC 1210 Mulled Awning and Fixed Windows Approved for use outside HVHZ:Yes (Report ESP019136P-1688)_pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +65/-85 04/15/2025 Other: 3/4"insulated glass comprised of 3.9mm (5/32") Installation Instructions annealed/6mm (1/4") Endur Spacer/3.1mm (1/8")/ FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and annealed glass.The glass was set from the interior against Picture(clip)_pdf silicone back bedding. In addition,a back bed of silicone was FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and used in the glazing pocket. (Missile D,Wind Zone 4) Picture(fin)_pdf FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(jamb)_pdf FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(mullion)_pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17697.12 1210 Premium Impact Awning with LC-PG65-MA 1054x2873 (42x113) Premium Impact Picture Stacked Above, Dual Glazed - Mulled Combination Assembly Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17697 R3 C CAC 1210 Mulled Awning and Fixed Windows Approved for use outside HVHZ:Yes (port ESP019136P-1688)_pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +65/-85 04/15/2025 Other: 1"insulated glass comprised of 3.9mm (5/32") Installation Instructions annealed/9.5mm (3/8")XL Edge Spacer/4.7mm (3/16")/ FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and .090" PVB/4.7mm (3/16")annealed glass.The glass was set Picture(clip)_pdf from the interior against silicone back bedding. In addition,a FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and back bed of silicone was used in the glazing pocket. (Missile D, Picture(fin).pdf Wind Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(jamb)_pdf FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and Picture(mullion)_pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility.Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® ® ® b__= Credit Card Safe C #6 NON-CORROSIVE SCREWS 1-1/2" MIN PENETRATION INTO FRAMING MEMBER 1-1/2" MINIMUM EMBEDMENT 3" FROM EACH CORNER INTO SUBSTRATE TYP 8-10"ON CENTER THROUGH NAILING FIN AROUND THE UNITS ENTIRE PERIMETER TYP WOOD BUCK 1 BY OTHERS TYP 0. USE SILICONE SEALANT 8 TO 10" AROUND ENTIRE PERIMETER 0. O.C. TYP BETWEEN NAILING FIN & 1 � WOOD BUCK BY OTHERS TYP 1/4" (6mm) MAX D0. D Weather Shield SHIM SPACE TYP _ Windows &Doors O.C. TYP � � 3" FROM EACH CORNER TYP 1209, 121o, 8211 C CASEMENT,AWNING,AND PICTURE C ORNER TYP FROM EACH NAILING FIN INSTALLATION C SECTION C-C SCALE 1 : 3 o 0 .625" MINIMUM EDGE DISTANCE SECTION D-D TYP SCALE 1 : 3 NOTE(S): 1. DIMENSIONED VIEWS ARE TYPICAL FOR ALL CROSS SECTION DETAILS. THIS SCHEDULE ADDRESSES ONLY THE FASTENERS REQUIRED TO ANCHOR THE PROPERTY OF WEATHER MATERIAL: WINDOW(S)TO ACHIEVE THE RATED DESIGN PRESSURE. THOROUGHLY READ SHINOTTOBEREPRINTED OR MFG.,INC. DRAWING IS Weather Shield AND FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS RECEIVED WITH SUBMITTED FOR USE OUTSIDE DIV./ORDER#: OF WEATHER SHIELD MFG.,INC UNIT. THIS GUIDE DOES NOT ADDRESS THE SEALING CONSIDERATIONS THAT ALL RIGHTS RESERVED DATE ORDERED: Windows &Doors MAY ARISE IN DIFFERENT WALL CONDITIONS. DIE#,x-REF#,COMPARATOR#: Q.C.COMPARATOR CHECK: ❑ FINISH: PRODUCTS: TYP.WALL THICKNESS: CUT STOCK SIZE: 1209, 1210, 8211 AREA: ECO OR W.S.#: 30166 TITLE WT./FT.: INSTALLATION INSTRUCTIONS FILE PATH: DWG. NO. I REV. DRAWN BY: DATE: 85-7438-36 REVISION DATE DESCRIPTION WHITE SLIP NUMBER ENG. DO NOT SCALE DRAWING JK/EB 1 10-30-14 SCALE: 1:12 ISHEET NAME: Sheen SHEET 1 OF 1 12 TO 14"ON CENTER TYP 1-1/4"MINIMUM EMBEDMENT 2.531 MINIMUM EDGE INTO SUBSTRATE TYP F 3"FROM 3"FROM DISTANCE AT HEAD TYP CORNER CORNER TYP TYP USE SILICONE SEALANT WOOD BUCK BY AROUND ENTIRE PERIMETER OTHERS TYP BETWEEN JAMB&FRAMING MEMBER BY OTHERS TYP I I 12 TO 14"ON CENTER TYP 1/4"(6mm)MAX SHIM SPACE TYP E E #8 NON-CORROSIVE SCREWS Weather Shield 3"FROM EACH CORNER; 12-14"ON CENTER THROUGH Windows &Doors JAMB INTO FRAMING MEMBER; F 1209, 1210, 8211 CASEMENT,AWNING AND PICTURE THR U THE JAMB INSTALLATION 1-1/4"MINIMUM EMBEDMENT INTO SUBSTRATE TYP #8 NON-CORROSIVE SCREWS 3"FROM EACH CORNER; 12-14"ON CENTER THROUGH WOOD JAMB INTO FRAMING MEMBER; VA :> 2.531 MINIMUM EDGE DISTANCE TYP 3.531 MINIMUM EDGE DISTANCE AT SILL TYP SECTION E-E SECTION F-F SCALE 1 : 4 SCALE 1 : 4 NOTE(S): 1. DIMENSIONED VIEWS ARE TYPICAL FOR ALL CROSS SECTION DETAILS. PROPERTY OF WEATHER MATERIAL: THIS SCHEDULE ADDRESSES ONLY THE FASTENERS REQUIRED TO ANCHOR THE SHIELD TO B INC. DRAWING IS Weather Shield NOT TO BE REPRINTED OR WINDOW(S)TO ACHIEVE THE RATED DESIGN PRESSURE. THOROUGHLY READ SUBMITTED FOR USE OUTSIDE DIV./ORDER#: AND FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS RECEIVED WITH OF WEATHER SHIELD MFG.,INC UNIT. THIS GUIDE DOES NOT ADDRESS THE SEALING CONSIDERATIONS THAT ALL RIGHTS RESERVED DATE ORDERED: Windows &Doors MAY ARISE IN DIFFERENT WALL CONDITIONS. DIEa,x-REF#,coMPARATOR#: O.c.coMPARATORCHECK: ❑ FINISH: PRODUCTS: TYP.WALL THICKNESS: CUT STOCK SIZE: 1209, 1210, 8211 AREA: ECO OR W.S.#: 30166 TITLE WT./FT.: INSTALLATION INSTRUCTIONS FILE PATH: DWG. NO. REV. DRAWN BY: DATE: 85-7438-38 REVISION DATE DESCRIPTION WHITE SLIP NUMBER ENG. DO NOT SCALE DRAWING JK/EB 10-30-14 SCALE: 1:12 ISHEET NAME: Sheen SHEET 1 OF 1 INSTALLATION CLIPS REFERENCE DRAWING NUMBER 85-7438-36 FOR THE INDIVIDUAL UNIT NAIL FIN INSTALLATION METHOD. TO 4.000 TYP AT EACH MULL/STACK REFERENCE DRAWING NUMBER 85-7438-37 FOR THE INDIVIDUAL UNIT INSTALLATION CLIP INSTALLATION METHOD. JOINT TYPICAL REFERENCE DRAWING NUMBER 85-7438-38 FOR THE INDIVIDUAL UNIT THROUGH THE JAMB INSTALLATION METHOD. WOOD BUCK BY OTHERS TYP .50"MINIMUM EDGE B DISTANCE TYP 0 1 _ 1/4"(6mm)MAX SHIM SPACE TYP I A A Weather Shield I Windows &Doors 1209, 121o, 8211 SECTION B-B B CASEMENT,AWNING,AND PICTURE SCALE 1 : 4 MULLION INSTALLATION 7/1 1/2"MINIMUM PENETRATION INTO JAMB TYP I 0 0 - (4)#7 NON-CORROSIVE SCREWS THROUGH INSTALLATION CLIP INTO FRAMING MEMBER TYP (4)#6 NON-CORROSIVE SCREWS THROUGH INSTALLATION CLIP SECTION A-A INTO UNIT TYP 1-1/2"MINIMUM EMBEDMENT SCALE 1 : 4 INTO SUBSTRATE TYP NOTE(S): 1. DIMENSIONED VIEWS ARE TYPICAL FOR ALL CROSS SECTION DETAILS. PROPERTY OF WEATHER MATERIAL: SHIELD MOBERC. DRAWING IS Weather Shield THIS SCHEDULE ADDRESSES ONLY THE FASTENERS REQUIRED TO ANCHOR THE NOT TO BE REPRINTED OR WINDOW(S)TO ACHIEVE THE RATED DESIGN PRESSURE. THOROUGHLY READ SUBMITTED FOR USE OUTSIDE DIV./ORDER#: AND FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS RECEIVED WITH of WEATHER SHIELD RESEMFG.RVED INC 7 ALL RIGHTS RESERVED DATE ORDERED: Windows &Doors UNIT. THIS GUIDE DOES NOT ADDRESS THE SEALING CONSIDERATIONS THAT DIE a,x-REF#,coMPARATORa: O.c.COMPARATOR CHECK: ❑ MAY ARISE IN DIFFERENT WALL CONDITIONS. FINISH: PRODUCTS: TYP.WALL THICKNESS: CUT STOCK SIZE: 1209, 1210, 8211 TWIN AREA: ECO OR W.S.#: TITLE: WT./FT.: iINSTALLATION INSTRUCTIONS FILE PATH: DWG. NO. REV. DRAWN BY: DATE: 85-781.5-21 REVISION DATE DESCRIPTION WHITE SLIP NUMBER ENG. DO NOT SCALE DRAWING JK/EB 10-30-14 SCALE: 1:12 SHEET NAME: Sheen SHEET 1 OF 1 10 TO 12"ON CENTER TYP F 3"FROM 3"FROM WOOD BUCK BY NE SEALANT TCORNER USE COPRNER AROUND EONTIRE PERIMETER OTHERS TYP BETWEEN JAMB&FRAMING 50"MINIMUM MEMBER BY OTHERS TYP EDGE DISTANCE TYP E E 10 TO 12" 1/4"(6mm)MAX I ON CENTER - SHIM SPACE TYP TYP I Weather Shield Windows &Doors SECTION F-F F 1209, 1210, 8211 SCALE 1 : 4 CASEMENT,AWNING,AND PICTURE Installation Clip INSTALLATION METHOD 1/2"MINIMUM PENETRATION 1 I INTO JAMB TYP 1 (4)#7 NON-CORROSIVE SCREWS THROUGH INSTALLATION CLIP INTO FRAMING MEMBER TYP (4)#6 NON-CORROSIVE SCREWS THROUGH INSTALLATION CLIP 1-1/2"MINIMUM EMBEDMENT INTO UNIT TYP INTO SUBSTRATE TYP SECTION E-E SCALE 1 : 4 NOTE(S): 1. DIMENSIONED VIEWS ARE TYPICAL FOR ALL CROSS SECTION DETAILS. THIS SCHEDULE ADDRESSES ONLY THE FASTENERS REQUIRED TO ANCHOR THE PROPERTY OF WEATHER MATERIAL: SHIELD MC. DRAWING IS Weather Shield WINDOW(S)TO ACHIEVE THE RATED DESIGN PRESSURE. THOROUGHLY READ NOT TOO BE BE REPRINTED OR AND FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS RECEIVED WITH SUBMITTED FOR USE OUTSIDE DIV./ORDER#: UNIT. THIS GUIDE DOES NOT ADDRESS THE SEALING CONSIDERATIONS THAT OF WEATHER SHIELD MFG.,INC ALL RIGHTS RESERVED DATE ORDERED: Windows &Doors MAY ARISE IN DIFFERENT WALL CONDITIONS. DIE#,x-REF#,COMPARATOR#: Q.C.COMPARATOR CHECK: ❑ W7 FINISH: PRODUCTS: TYP.WALL THICKNESS: CUT STOCK SIZE: 1209, 1210, 8211 AREA: ECO OR W.S.#: 30166 TITLE WT./FT.: INSTALLATION INSTRUCTIONS FILE PATH: DWG. NO. REV. DRAWN aY: DATE: 85-7438-37 REVISION DATE DESCRIPTION WHITE SLIP NUMBER ENG. DO NOT SCALE DRAWING JK/EB 10-30-14 SCALE: 1:12 ISHEET NAME: Sheen SHEET 1 OF 1 IN DOW&000 R ■E� I MMUFACTURERS ASSOCIAMON Hallmark® Certificate of A s, INC. Administrative Maaalemmi �11WDMA Conformance and License (CCL) 4t4> Syacmi,Ine. Weather Shield Mfg. Inc. Mfr ID: 449 1 Weathershield Plaza For more Information visit www.amscert.com PO Box 309 Website: PO Box 309 TEL: 715-748-2100 Medford, WI 54451-0309 Product No. Product Name Standard Rating Wide High Test Report# CertDate ExpDate 449-H-017.35 Premium Impact Awning,with Premium Impact Picture 101/I.S.2/A440-11 Class LC-PG65;Size Tested 1435mm 1054mm ESP019136P-1688 6/19/2015 4/15/2025 Stacked above,Dual Glazed(1210) 1435mm Trib Width/1054mm Trib Span Span(56.50"Trib Width Width/41.50••Span)Type-MA; DP+65/-85 psf;Water Test Press 470Pa(9.82psf);Can. Air Infil/Exfil. Level=A3 449-H-017.36 Premium Impact Awning,with Premium Impact Picture 101/I.S.2/A440-08 Class LC-PG65;Size Tested 1054mm 2873mm ESP019136P-1688 6/19/2015 4/15/2025 Stacked above,Dual Glazed(1210) 1054mm x 2873mm(42"x 113")Type-MA; DP+65/-85 psf;Water Test Press 470Pa (9.82psf);Can.Air Infil/Exfil. Level=A3 449-H-017.37 Premium Impact Awning,with Premium Impact Picture AAMA 450-10 Class LC-PG65;Size Tested 1435mm 1054mm ESP019136P-1688 6/19/2015 4/15/2025 Stacked above,Dual Glazed(1210)-Horizontal Mullion 1435mm Trib Widthx 1054mm Trib span span(56.5 trib Width/41.5in Width span)Type-MA; DP+65/-85 psf;Water Test Press 470Pa (9.82psf);Can.Air Infil/Exfil. Level=A3 449-H-017.38 Premium Impact Awning,with Premium Impact Picture TAS 201/202/203-94 DP+65/-85 psf, Missile D, 1054mm 2873mm ESP019136P-1688 6/19/2015 4/15/2025 Stacked above,Dual Glazed(1210)-Horizontal Mullion Wind Zone 4 449-H-017.39 Premium Impact Awning,with Premium Impact Picture ASTM E-1996 12/ASTM DP+65/-85 psf, Missile D, 1054mm 2873mm ESP019136P-1688 6/22/2015 4/15/2025 Stacked above,Dual Glazed(1210)-Horizontal Mullion E-1886-05 Wind Zone 4 WDMA HEREBY CERTIFIES that the aforesaid Company ("Licensee"), at its , participating manufacturing plant(s), is licensed to use the WDMA Registered By. 1� - o � e� VP of Crfrcatiorr Programs, ffii'uffrrrark Hallmark on product lines that have been manufactured in accordance with the standards. It is further certified that the plant(s), facilities, quality control procedures, methods, and processes of Licensee have been inspected by By. ,,,, cic Rhonda i= rr+ iv , WDMA, and are subject to regular follow-up inspection and test. It is further certified that samples of the product set forth above were tested and found to Program Sponsor: Program Administrator: comply with the standards. Window and Door Manufacturers Assoc Administrative Management Systems, Inc. 330 N.Wabash Avenue,Suite 2000 PO Box 730, 100 West Main Chicago, IL 60611 Sackets Harbor,NY 13685 TEL(312)673-4828 www.wdma.com TEL(315)646-2234 staff@amscert.com WD-20 10114109 Wednesday, July 01, 2015 Page 1