HomeMy WebLinkAboutNOA FL17697.12 ProfessionalRegulation
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications I Contact Us BCIS Site Map Links I Search I
Florida
r I c Product Approval
Ia"' USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL17697-R3
Application Type Affirmation
Code Version 2020
Application Status Approved
Comments
Archived C
Product Manufacturer Weather Shield Mfg.,Inc.
Address/Phone/Email 829 N. 8th Street
Medford,WI 54451
(715) 748-2100 Ext3932
val.bach@weathershield.com
Authorized Signature Mark Brandner
mark.brandner@weathershield.com
Technical Representative Dale Turzinski
Address/Phone/Email 829 N. 8th
Medford,WI 54451
(715) 748-2100 Ext7842
dale.turzinski@weathershield.com
Quality Assurance Representative Dale Turzinski
Address/Phone/Email 829 N. 8th
Medford,WI 54451
(715) 748-2100 Ext7842
dale.turzinski@weathershield.com
Category Windows
Subcategory Awning
Compliance Method Certification Mark or Listing
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
Referenced Standard and Year(of Standard) Standard Year
AAMA 450-10 2010
AAMA/WDMA/CSA 101/I.S.2/A440-08 2008
AAMA/WDMA/CSA 101/I.S.2/A440-11 2011
ASTM E 1886 2005
ASTM E 1996 2012
ASTM E330-02 2010
TAS 201,TAS 202,TAS 203 1994
Equivalence of Product Standards
Certified By
I affirm that there are no changes in the new Florida Building
Code which affect my product(s)and my product(s)are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity Yes No N/A
FL17697 R3 COC tb-equivilancy-memo nafs 201.pdf
FL17697 R3 COC TB-Revised Equivalency ASTM .pdf
Product Approval Method Method 1 Option A
Date Submitted 12/29/2020
Date Validated 12/29/2020
Date Pending FBC Approval
Date Approved 01/03/2021
Summary of Products
FL# Model,Number or Name Description
17697.1 1209 Premium Awning Impact LC-PG65-AP 1054x902(4206)
Window,Single Glazed
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17697 R3 C CAC 1209 Awning Windows(Report
Approved for use outside HVHZ:Yes ESP019135P-1687)_pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +65/-85 05/21/2025
Other: 15/32"Cardinal "LG" laminated glass comprised of Installation Instructions
(3/16")annealed/.090" PVB/(3/16")annealed glass.The FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
glass was set from the interior against silicone back bedding. In Picture(fin)_pdf
addition,a back bed of silicone was used in the glazing pocket. Verified By: Window and Door Manufacturer Association
(Missile D,Wind Zone 4) Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17697.2 1209 Premium Awning Window LC-PG55-AP 1511x1054(60x42)
(Annealed Monolithic)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17697 R3 C CAC WH 1209 Awning 60-42(Annealed
Approved for use outside HVHZ:Yes Monolithic)_(Report ESP01866913-1662).pdf
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure: +55/-70 01/08/2025
Other: 7.9mm(5/16")annealed glass.The glass was set from Installation Instructions
the interior against silicone back bedding. In addition,a back FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
bed of silicone was used in the glazing pocket. Picture(fin)_pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17697.3 1209 Twin Premium Impact Awning LC-PG55-MA 3035x2108(120x83)
with Twin Premium Impact Picture
Stacked Above, Single Glazed -
Reinforced Vertical Mullion
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17697 R3 C CAC 1209 Twin Premium Impact Awning With
Approved for use outside HVHZ:Yes Twin Premium Impact Picture Stacked Above,Single Glazed
Impact Resistant:Yes (Report ESP018434P-1647).pdf
Design Pressure: +55/-70 Quality Assurance Contract Expiration Date
Other: 7/16"Cardinal laminated glass comprised of(3/16") 01/22/2025
annealed/ .090" PVB/(3/16")annealed glass.The glass was Installation Instructions
set from the interior against silicone back bedding. In addition, FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
a back bed of silicone was used in the glazing pocket. (Missile Picture(mullion),pdf
D,Wind Zone 4) Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17697.4 1209 Twin Premium Impact Awning LC-PG55-MA 3035x2108(120x83)
with Twin Premium Impact Picture
Stacked Above, Single Glazed -
Unreinforced Horizontal Mullion
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes FL17697 R3 C CAC 1209 Twin Premium Impact Awning With
Approved for use outside HVHZ: Yes Twin Premium Impact Picture Stacked Above,Single Glazed
Impact Resistant:Yes (Report ESP018434P-1647)_p!f
Design Pressure: +55/-70 Quality Assurance Contract Expiration Date
Other: 7/16"Cardinal laminated glass comprised of(3/16") 01/22/2025
annealed/ .090" PVB/(3/16")annealed glass.The glass was Installation Instructions
set from the interior against silicone back bedding. In addition, FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
a back bed of silicone was used in the glazing pocket. (Missile Picture(mullion)_pdf
D,Wind Zone 4) Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17697.5 1209 Twin Premium Impact Awning LC-PG55-MA 3035x2108(120x83)
with Twin Premium Impact Picture
Stacked Above, Single Glazed,
Horizontal Mullion
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17697 R3 C CAC 1209 Twin Premium Impact Awning With
Approved for use outside HVHZ:Yes Twin Premium Impact Picture Stacked Above,Single Glazed
Impact Resistant:Yes (Report ESP018434P-1647)_pdf
Design Pressure: +55/-70 Quality Assurance Contract Expiration Date
Other: 7/16"Cardinal laminated glass comprised of(3/16") 01/22/2025
annealed/ .090" PVB/(3/16")annealed glass.The glass was Installation Instructions
set from the interior against silicone back bedding. In addition, FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
a back bed of silicone was used in the glazing pocket. (Missile Picture(clip)_pdf
D,Wind Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(fin).pdf
FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(jamb)_pdf
FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Pi r (mullion)_pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17697.6 1209 Twin Premium Impact Awning LC-PG55-MA 3035x2108(120x83)
with Twin Premium Impact Picture
Stacked Above, Single Glazed,
Vertical Mullion
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17697 R3 C CAC 1209 Twin Premium Impact Awning With
Approved for use outside HVHZ:Yes Twin Premium Impact Picture Stacked Above,Single Glazed
Impact Resistant:Yes (Report ESP01843413-1647)_pdf
Design Pressure: +55/-70 Quality Assurance Contract Expiration Date
Other: 7/16"Cardinal laminated glass comprised of(3/16") 01/22/2025
annealed/ .090" PVB/(3/16")annealed glass.The glass was Installation Instructions
set from the interior against silicone back bedding. In addition, FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
a back bed of silicone was used in the glazing pocket. (Missile Picture(clip)_pdf
D,Wind Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(fin).pdf
R3
FL17697
II WS 1209, 1210,8211 Casement,Awning,and
Picture(jamb)_pdf
FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(mullion).pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17697.7 1210 Premium Awning Impact LC-PG55-AP 1511x1054(60x42)
Window, Dual Glazed
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes FL17697 R3 C CAC WH 1210 Awnings 60x42 (Report
Approved for use outside HVHZ: Yes ESP018659P-1661)_pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +55/-70 12/31/2024
Other: 3/4"insulated glass comprised of 3.9mm (5/32") Installation Instructions
annealed/6.3mm (1/4")Super Spacer/3.1mm (1/8")/ .090" FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
PVB/3.1mm (1/8")annealed glass.The glass was set from the Picture(fin)_pdf
interior against silicone back bedding. In addition,a back bed Verified By: Window and Door Manufacturer Association
of silicone was used in the glazing pocket. (Missile D,Wind Created by Independent Third Party:
Zone 4) Evaluation Reports
Created by Independent Third Party:
17697.8 1210 Premium Awning Impact LC-PG55-AP 1511x1054(60x42)
Window, Dual Glazed
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17697 R3 C CAC WH 1210 Awnings 60x42(Report
Approved for use outside HVHZ:Yes ESP01865913-1661),pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +55/-70 12/31/2024
Other: 1"insulated glass comprised of 3.9mm (5/32") Installation Instructions
annealed/ 13mm(1/2") Endura Spacer/3.1mm (1/8")/.090" FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
PVB/3.1mm (1/8")annealed glass.The glass was set from the Picture(fin)_pdf
interior against silicone back bedding. In addition,a back bed Verified By: Window and Door Manufacturer Association
of silicone was used in the glazing pocket. (Missile D,Wind Created by Independent Third Party:
Zone 4) Evaluation Reports
Created by Independent Third Party:
17697.9 1210 Premium Impact Awning with LC-PG65-MA 1054x2873 (42x113)
Premium Impact Picture Stacked
Above, Dual Glazed - Horizontal
Mullion
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17697 R3 C CAC 1210 Mulled Awning and Fixed Windows
Approved for use outside HVHZ:Yes (Report ESP019136P-1688)_pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +65/-85 04/15/2025
Other: 3/4" insulated glass comprised of 3.9mm (5/32") Installation Instructions
annealed/6.3mm (1/4")Super Spacer/3.1mm (1/8")/ .090" FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
PVB/3.1mm (1/8")annealed glass.The glass was set from the Picture(clip)_pdf
interior against silicone back bedding. In addition,a back bed FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
of silicone was used in the glazing pocket. (Missile D,Wind Picture(fin).pdf
Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(jamb)_pdf
FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(mullion),pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17697.10 1210 Premium Impact Awning with LC-PG65-MA 1054x2873(42x113)
Premium Impact Picture Stacked
Above, Dual Glazed - Mulled
Combination Assembly
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17697 R3 C CAC 1210 Mulled Awning and Fixed Windows
Approved for use outside HVHZ:Yes (Report ESP01913613-1688)_pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +65/-85 04/15/2025
Other: 3/4"insulated glass comprised of 3.9mm (5/32") Installation Instructions
annealed/6.3mm (1/4")Super Spacer/3.1mm (1/8")/ .090" FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
PVB/3.1mm (1/8")annealed glass.The glass was set from the Picture(clip)_pdf
interior against silicone back bedding. In addition,a back bed FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
of silicone was used in the glazing pocket. (Missile D,Wind Picture(fin)_pdf
Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(jamb)_pdf
FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(mullion),pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17697.11 1210 Premium Impact Awning with LC-PG65-MA 1054x2873 (42x113)
Premium Impact Picture Stacked
Above, Dual Glazed - Mulled
Combination Assembly
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17697 R3 C CAC 1210 Mulled Awning and Fixed Windows
Approved for use outside HVHZ:Yes (Report ESP019136P-1688)_pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +65/-85 04/15/2025
Other: 3/4"insulated glass comprised of 3.9mm (5/32") Installation Instructions
annealed/6mm (1/4") Endur Spacer/3.1mm (1/8")/ FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
annealed glass.The glass was set from the interior against Picture(clip)_pdf
silicone back bedding. In addition,a back bed of silicone was FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
used in the glazing pocket. (Missile D,Wind Zone 4) Picture(fin)_pdf
FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(jamb)_pdf
FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(mullion)_pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17697.12 1210 Premium Impact Awning with LC-PG65-MA 1054x2873 (42x113)
Premium Impact Picture Stacked
Above, Dual Glazed - Mulled
Combination Assembly
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL17697 R3 C CAC 1210 Mulled Awning and Fixed Windows
Approved for use outside HVHZ:Yes (port ESP019136P-1688)_pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +65/-85 04/15/2025
Other: 1"insulated glass comprised of 3.9mm (5/32") Installation Instructions
annealed/9.5mm (3/8")XL Edge Spacer/4.7mm (3/16")/ FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
.090" PVB/4.7mm (3/16")annealed glass.The glass was set Picture(clip)_pdf
from the interior against silicone back bedding. In addition,a FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
back bed of silicone was used in the glazing pocket. (Missile D, Picture(fin).pdf
Wind Zone 4) FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(jamb)_pdf
FL17697 R3 II WS 1209, 1210,8211 Casement,Awning,and
Picture(mullion)_pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility.Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ® ® b__=
Credit Card
Safe
C
#6 NON-CORROSIVE SCREWS
1-1/2" MIN PENETRATION INTO FRAMING MEMBER 1-1/2" MINIMUM EMBEDMENT
3" FROM EACH CORNER INTO SUBSTRATE TYP
8-10"ON CENTER THROUGH NAILING FIN
AROUND THE UNITS ENTIRE PERIMETER TYP WOOD BUCK
1 BY OTHERS TYP
0.
USE SILICONE SEALANT
8 TO 10" AROUND ENTIRE PERIMETER
0. O.C. TYP BETWEEN NAILING FIN &
1 � WOOD BUCK BY OTHERS TYP
1/4" (6mm) MAX
D0. D Weather Shield SHIM SPACE TYP
_
Windows &Doors
O.C. TYP � � 3" FROM EACH
CORNER TYP 1209, 121o, 8211
C CASEMENT,AWNING,AND PICTURE
C ORNER TYP FROM EACH NAILING FIN INSTALLATION
C
SECTION C-C
SCALE 1 : 3
o
0
.625" MINIMUM
EDGE DISTANCE
SECTION D-D TYP
SCALE 1 : 3
NOTE(S):
1. DIMENSIONED VIEWS ARE TYPICAL FOR ALL CROSS SECTION DETAILS.
THIS SCHEDULE ADDRESSES ONLY THE FASTENERS REQUIRED TO ANCHOR THE PROPERTY OF WEATHER MATERIAL:
WINDOW(S)TO ACHIEVE THE RATED DESIGN PRESSURE. THOROUGHLY READ SHINOTTOBEREPRINTED OR MFG.,INC. DRAWING IS Weather Shield
AND FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS RECEIVED WITH SUBMITTED FOR USE OUTSIDE DIV./ORDER#:
OF WEATHER SHIELD MFG.,INC UNIT. THIS GUIDE DOES NOT ADDRESS THE SEALING CONSIDERATIONS THAT ALL RIGHTS RESERVED DATE ORDERED: Windows &Doors
MAY ARISE IN DIFFERENT WALL CONDITIONS. DIE#,x-REF#,COMPARATOR#: Q.C.COMPARATOR CHECK: ❑
FINISH: PRODUCTS:
TYP.WALL THICKNESS: CUT STOCK SIZE: 1209, 1210, 8211
AREA: ECO OR W.S.#: 30166 TITLE
WT./FT.: INSTALLATION INSTRUCTIONS
FILE PATH: DWG. NO. I REV.
DRAWN BY: DATE: 85-7438-36
REVISION DATE DESCRIPTION WHITE SLIP NUMBER ENG. DO NOT SCALE DRAWING JK/EB 1 10-30-14 SCALE: 1:12 ISHEET NAME: Sheen SHEET 1 OF 1
12 TO 14"ON CENTER TYP 1-1/4"MINIMUM EMBEDMENT
2.531 MINIMUM EDGE INTO SUBSTRATE TYP
F 3"FROM 3"FROM DISTANCE AT HEAD TYP
CORNER CORNER
TYP TYP
USE SILICONE SEALANT WOOD BUCK BY
AROUND ENTIRE PERIMETER OTHERS TYP
BETWEEN JAMB&FRAMING
MEMBER BY OTHERS TYP
I
I
12 TO 14"ON
CENTER TYP
1/4"(6mm)MAX
SHIM SPACE TYP
E E #8 NON-CORROSIVE SCREWS
Weather Shield 3"FROM EACH CORNER;
12-14"ON CENTER THROUGH
Windows &Doors JAMB INTO FRAMING MEMBER;
F 1209, 1210, 8211
CASEMENT,AWNING AND PICTURE
THR U THE JAMB INSTALLATION
1-1/4"MINIMUM EMBEDMENT
INTO SUBSTRATE TYP
#8 NON-CORROSIVE SCREWS
3"FROM EACH CORNER;
12-14"ON CENTER THROUGH
WOOD JAMB INTO FRAMING MEMBER; VA
:>
2.531 MINIMUM EDGE
DISTANCE TYP
3.531 MINIMUM EDGE
DISTANCE AT SILL TYP
SECTION E-E SECTION F-F
SCALE 1 : 4
SCALE 1 : 4
NOTE(S):
1. DIMENSIONED VIEWS ARE TYPICAL FOR ALL CROSS SECTION DETAILS.
PROPERTY OF WEATHER MATERIAL:
THIS SCHEDULE ADDRESSES ONLY THE FASTENERS REQUIRED TO ANCHOR THE SHIELD TO B INC. DRAWING IS Weather Shield
NOT TO BE REPRINTED OR
WINDOW(S)TO ACHIEVE THE RATED DESIGN PRESSURE. THOROUGHLY READ SUBMITTED FOR USE OUTSIDE DIV./ORDER#:
AND FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS RECEIVED WITH OF WEATHER SHIELD MFG.,INC
UNIT. THIS GUIDE DOES NOT ADDRESS THE SEALING CONSIDERATIONS THAT ALL RIGHTS RESERVED DATE ORDERED: Windows &Doors
MAY ARISE IN DIFFERENT WALL CONDITIONS. DIEa,x-REF#,coMPARATOR#: O.c.coMPARATORCHECK: ❑
FINISH: PRODUCTS:
TYP.WALL THICKNESS: CUT STOCK SIZE: 1209, 1210, 8211
AREA: ECO OR W.S.#: 30166 TITLE
WT./FT.: INSTALLATION INSTRUCTIONS
FILE PATH: DWG. NO. REV.
DRAWN BY: DATE: 85-7438-38
REVISION DATE DESCRIPTION WHITE SLIP NUMBER ENG. DO NOT SCALE DRAWING JK/EB 10-30-14 SCALE: 1:12 ISHEET NAME: Sheen SHEET 1 OF 1
INSTALLATION CLIPS REFERENCE DRAWING NUMBER 85-7438-36 FOR THE INDIVIDUAL UNIT NAIL FIN INSTALLATION METHOD.
TO 4.000 TYP AT EACH MULL/STACK REFERENCE DRAWING NUMBER 85-7438-37 FOR THE INDIVIDUAL UNIT INSTALLATION CLIP INSTALLATION METHOD.
JOINT TYPICAL REFERENCE DRAWING NUMBER 85-7438-38 FOR THE INDIVIDUAL UNIT THROUGH THE JAMB INSTALLATION METHOD.
WOOD BUCK
BY OTHERS TYP
.50"MINIMUM EDGE
B DISTANCE TYP
0 1
_ 1/4"(6mm)MAX
SHIM SPACE TYP
I
A A Weather Shield
I
Windows &Doors
1209, 121o, 8211 SECTION B-B
B CASEMENT,AWNING,AND PICTURE SCALE 1 : 4
MULLION INSTALLATION
7/1
1/2"MINIMUM PENETRATION
INTO JAMB TYP
I
0 0 - (4)#7 NON-CORROSIVE SCREWS
THROUGH INSTALLATION CLIP
INTO FRAMING MEMBER TYP
(4)#6 NON-CORROSIVE SCREWS
THROUGH INSTALLATION CLIP
SECTION A-A INTO UNIT TYP 1-1/2"MINIMUM EMBEDMENT
SCALE 1 : 4 INTO SUBSTRATE TYP
NOTE(S):
1. DIMENSIONED VIEWS ARE TYPICAL FOR ALL CROSS SECTION DETAILS.
PROPERTY OF WEATHER MATERIAL:
SHIELD MOBERC. DRAWING IS Weather Shield
THIS SCHEDULE ADDRESSES ONLY THE FASTENERS REQUIRED TO ANCHOR THE NOT TO BE REPRINTED OR
WINDOW(S)TO ACHIEVE THE RATED DESIGN PRESSURE. THOROUGHLY READ SUBMITTED FOR USE OUTSIDE DIV./ORDER#:
AND FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS RECEIVED WITH of WEATHER SHIELD RESEMFG.RVED
INC 7 ALL RIGHTS RESERVED DATE ORDERED: Windows &Doors
UNIT. THIS GUIDE DOES NOT ADDRESS THE SEALING CONSIDERATIONS THAT DIE a,x-REF#,coMPARATORa: O.c.COMPARATOR CHECK: ❑
MAY ARISE IN DIFFERENT WALL CONDITIONS.
FINISH: PRODUCTS:
TYP.WALL THICKNESS: CUT STOCK SIZE: 1209, 1210, 8211 TWIN
AREA: ECO OR W.S.#: TITLE:
WT./FT.: iINSTALLATION INSTRUCTIONS
FILE PATH: DWG. NO. REV.
DRAWN BY: DATE: 85-781.5-21
REVISION DATE DESCRIPTION WHITE SLIP NUMBER ENG. DO NOT SCALE DRAWING JK/EB 10-30-14 SCALE: 1:12 SHEET NAME: Sheen SHEET 1 OF 1
10 TO 12"ON CENTER TYP
F 3"FROM 3"FROM WOOD BUCK BY
NE SEALANT
TCORNER USE COPRNER AROUND EONTIRE PERIMETER OTHERS TYP
BETWEEN JAMB&FRAMING 50"MINIMUM
MEMBER BY OTHERS TYP EDGE DISTANCE
TYP
E E 10 TO 12" 1/4"(6mm)MAX
I
ON CENTER - SHIM SPACE TYP
TYP
I
Weather Shield
Windows &Doors
SECTION F-F
F 1209, 1210, 8211 SCALE 1 : 4
CASEMENT,AWNING,AND PICTURE
Installation Clip
INSTALLATION METHOD
1/2"MINIMUM PENETRATION
1 I INTO JAMB TYP
1
(4)#7 NON-CORROSIVE SCREWS
THROUGH INSTALLATION CLIP
INTO FRAMING MEMBER TYP
(4)#6 NON-CORROSIVE SCREWS
THROUGH INSTALLATION CLIP 1-1/2"MINIMUM EMBEDMENT
INTO UNIT TYP INTO SUBSTRATE TYP
SECTION E-E
SCALE 1 : 4
NOTE(S):
1. DIMENSIONED VIEWS ARE TYPICAL FOR ALL CROSS SECTION DETAILS.
THIS SCHEDULE ADDRESSES ONLY THE FASTENERS REQUIRED TO ANCHOR THE PROPERTY OF WEATHER MATERIAL:
SHIELD MC. DRAWING IS Weather Shield
WINDOW(S)TO ACHIEVE THE RATED DESIGN PRESSURE. THOROUGHLY READ NOT TOO BE BE REPRINTED OR
AND FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS RECEIVED WITH SUBMITTED FOR USE OUTSIDE DIV./ORDER#:
UNIT. THIS GUIDE DOES NOT ADDRESS THE SEALING CONSIDERATIONS THAT OF WEATHER SHIELD MFG.,INC
ALL RIGHTS RESERVED DATE ORDERED: Windows &Doors
MAY ARISE IN DIFFERENT WALL CONDITIONS. DIE#,x-REF#,COMPARATOR#: Q.C.COMPARATOR CHECK: ❑ W7
FINISH: PRODUCTS:
TYP.WALL THICKNESS: CUT STOCK SIZE: 1209, 1210, 8211
AREA: ECO OR W.S.#: 30166 TITLE
WT./FT.: INSTALLATION INSTRUCTIONS
FILE PATH: DWG. NO. REV.
DRAWN aY: DATE: 85-7438-37
REVISION DATE DESCRIPTION WHITE SLIP NUMBER ENG. DO NOT SCALE DRAWING JK/EB 10-30-14 SCALE: 1:12 ISHEET NAME: Sheen SHEET 1 OF 1
IN DOW&000 R
■E� I MMUFACTURERS ASSOCIAMON Hallmark® Certificate of A s, INC.
Administrative Maaalemmi
�11WDMA Conformance and License (CCL) 4t4> Syacmi,Ine.
Weather Shield Mfg. Inc. Mfr ID: 449
1 Weathershield Plaza For more Information visit www.amscert.com
PO Box 309 Website:
PO Box 309 TEL: 715-748-2100
Medford, WI 54451-0309
Product No. Product Name Standard Rating Wide High Test Report# CertDate ExpDate
449-H-017.35 Premium Impact Awning,with Premium Impact Picture 101/I.S.2/A440-11 Class LC-PG65;Size Tested 1435mm 1054mm ESP019136P-1688 6/19/2015 4/15/2025
Stacked above,Dual Glazed(1210) 1435mm Trib Width/1054mm Trib Span
Span(56.50"Trib Width
Width/41.50••Span)Type-MA;
DP+65/-85 psf;Water Test
Press 470Pa(9.82psf);Can.
Air Infil/Exfil. Level=A3
449-H-017.36 Premium Impact Awning,with Premium Impact Picture 101/I.S.2/A440-08 Class LC-PG65;Size Tested 1054mm 2873mm ESP019136P-1688 6/19/2015 4/15/2025
Stacked above,Dual Glazed(1210) 1054mm x 2873mm(42"x
113")Type-MA; DP+65/-85
psf;Water Test Press 470Pa
(9.82psf);Can.Air Infil/Exfil.
Level=A3
449-H-017.37 Premium Impact Awning,with Premium Impact Picture AAMA 450-10 Class LC-PG65;Size Tested 1435mm 1054mm ESP019136P-1688 6/19/2015 4/15/2025
Stacked above,Dual Glazed(1210)-Horizontal Mullion 1435mm Trib Widthx 1054mm Trib span
span(56.5 trib Width/41.5in Width
span)Type-MA; DP+65/-85
psf;Water Test Press 470Pa
(9.82psf);Can.Air Infil/Exfil.
Level=A3
449-H-017.38 Premium Impact Awning,with Premium Impact Picture TAS 201/202/203-94 DP+65/-85 psf, Missile D, 1054mm 2873mm ESP019136P-1688 6/19/2015 4/15/2025
Stacked above,Dual Glazed(1210)-Horizontal Mullion Wind Zone 4
449-H-017.39 Premium Impact Awning,with Premium Impact Picture ASTM E-1996 12/ASTM DP+65/-85 psf, Missile D, 1054mm 2873mm ESP019136P-1688 6/22/2015 4/15/2025
Stacked above,Dual Glazed(1210)-Horizontal Mullion E-1886-05 Wind Zone 4
WDMA HEREBY CERTIFIES that the aforesaid Company ("Licensee"), at its ,
participating manufacturing plant(s), is licensed to use the WDMA Registered By.
1� - o � e� VP of Crfrcatiorr Programs, ffii'uffrrrark
Hallmark on product lines that have been manufactured in accordance with the
standards. It is further certified that the plant(s), facilities, quality control
procedures, methods, and processes of Licensee have been inspected by By. ,,,, cic Rhonda i= rr+ iv ,
WDMA, and are subject to regular follow-up inspection and test. It is further
certified that samples of the product set forth above were tested and found to Program Sponsor: Program Administrator:
comply with the standards. Window and Door Manufacturers Assoc Administrative Management Systems, Inc.
330 N.Wabash Avenue,Suite 2000 PO Box 730, 100 West Main
Chicago, IL 60611 Sackets Harbor,NY 13685
TEL(312)673-4828 www.wdma.com TEL(315)646-2234 staff@amscert.com
WD-20 10114109 Wednesday, July 01, 2015 Page 1