Loading...
HomeMy WebLinkAboutRevision 3-8-22OFFICE USE ONLY: DATE FILED: :3• � REVISION FEE: D d PERMIT # SLC 2106-0267 RECEIPT # PLANNING &DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462-1553 APPLICATION FOR BUILDING PERM PROJECT INFORMATION REviSION LOCATION/SITE ���� ADDRESS: 7153 Gullotti Place, Port Saint Lucie, FL 34952 DETAILED DESCRIPTION OF PROJECT REVISIONS: Per Wanda Gahn - Revised Energy Calcs showing exterior frame wall with R13. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGC1520713 ST. LUCIE CO CERT. #: BUSINESS NAME: RA CONSTRUCTION CORP OF THE TREASURE COAST/HOMES BY ABURTON QUALIFIERS NAME: Richard A. Adams III ADDRESS: 850 N. Federal Hwy., Ste. 226 CITY: Stuart STATE: FL ZIP: 34994 PHONE (DAYTIME): 772-446-4576 FAX: 772-446-4514 OWNER/BUILDER INFORMATION: NAME: John and Lynne Brady ADDRESS: 523 Sweet Bay Circle CITY: Jupiter PHONE (DAYTIME: 561-317-6493 STATE: FL ARCHITECT/ENGINEER INFORMATION: NAME: Stanley Forrest ADDRESS: 5000 Avenue Of The Stars CITY: Kissimmee PHONE (DAYTIME): 407-997-7890 SLCCC: 9123109 Revised 06130117 STATE: FL FAX: FAX: ZIP: 33458 ZIP: 34746 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. GULLOTTI PLACE, PORT ST LUCIE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead Aggrd2=0.0 1880.00 ft2 b. Frame - Wood, Adjacent R=11.0 220.00 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=13.0 190.00 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Roof Deck (Unvented) R=20.0 2048.00 ft2 6. Conditioned floor area (W) 2048 b. N/A R= ft2 7. Description Area c. N/A R= ft2 a. U-Fa to a. U-Factor: SH U=0.1 272.33 ft2 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 150 SHGC: SHGC=0.19 b. U-Factor: Sgl, U=0.26 24.00 ft2 SHGC: SHGC=0.24 13. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a. Central Unit 36.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.194 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.98 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2048.00 ft2 Credits (Performance method) None b. N/A R= ft2 c. N/A R= ft2 i r I certify that this home has co plied with Florida Energy Construction through the, abov features Efficiency Code for Building -,�� be installed v T>r1E sa oI energy'saving which 5 - will or exceeded ( ) in this home before final {1, �spe8 io�n!'Otherwise, anew EPL Display Card will be completed based on installed Code c'ompii nt f atures. 1� �� Builder Signature: Date: 1� ,r ..:I Address of New Home: �� � � LLo-m T�, City/FL Zip: 0p2T•,s' j, "Cz i 1•l c vy� FL ��l `� oD *Note: This is not a Building Energy Rating. If your Index is below 70, your home may quali y efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the FI ida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/3/2022 11:12 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BRADY RESIDENCE Builder Name: HOMES BY ABURTON Street: GULLOTTI PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, Permit Number: Owner: JACK AND LYNN BRADY Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(2290.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead AggreR=0.0 1880.00 ft2 b. Frame - Wood, Adjacent R=11.0 220.00 ft2 3. Number of units, if multiple family 1 c. Frame -Wood, Exterior R=13.0 190.00 ftz 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2048.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2048.00 ft2 6. Conditioned floor area above grade (ft2) 2048 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(296.3 sqft.) Description Area 12. Ducts R ftz a. Sup: Attic, Ret: Attic, AH: Garage 6 150 a. U-Factor: Sgl, U=0.31 272.33 ftz SHGC: SHGC=0.19 b. U-Factor: Sgl, U=0.26 24.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.24 a. Central Unit 36.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.194 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2048.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2048.00 ft2 b. Conservation features b. NIA R= ft2 None c. N/A R= ft2 16. Credits None Total Proposed Modified Loads: 68.94 Glass/Floor Area: 0.145 PASS Total Baseline Loads: 69.06 1 hereby certify that the plans and specifications covered by Review of the plans and Q�'CH5 S74 this calculation are in compliance with the Florida Energy specifications covered by this ti. O� Code. calculation indicates compliance ,`o ��i„f'`%° _ =s ,•�� PREPARED BY: N/C L>5 ${CI�GWLL with the Florida Energy Code. Before is �r ��-: "f.•'°��� �O LU construction completed DATE: -3-2 22 ' this building will be inspected for compliance with Section 553.908 Florida Statutes. 1i4'it O I hereby certify that thisl ilding, as designed, is in compliance with the Florida Energy ew 3` SOU WL" OWNER/AGENT: ; I BUILDING OFFICIAL: DATE: v DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as 1k certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this pro quires an envelope leakage test report with envelope leakage no greater than 5.00 ACH60 (R402.4.1.2). - Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not.re��ti+ir R405 .2.3`�� 3/3/202211:12 AM EriergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY GNEGKLIST REPORT PROJECT Title: BRADY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2048 Lot # Owner Name: JACK AND LYNN BRADY Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: HOMES BY ABURTON Rotate Angle: 0 Street: GULLOTTI PLACE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2048 20480 SPACES Number Name Area Volume. Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 3 186 1860 No 0 1 1 Yes Yes Yes 2 LAUNDRY RM 140 1400 No 0 1 Yes Yes Yes 3 CLST 2 18 180 No 0 1 Yes Yes Yes 4 BEDROOM 2 168 1680 No 0 1 1 Yes Yes Yes 5 BATH 2 60 600 No 0 1 No Yes Yes 6 FAMILY RM 432 4320 No 0 1 Yes Yes Yes 7 KITCHEN 311 3110 Yes 0 1 Yes Yes Yes 8 HALLWAY 52 520 No 0 1 No Yes Yes 9 PANTRY 56 560 No 0 1 Yes Yes Yes 10 M BATH 224 2240 No 0 1 Yes Yes Yes 11 M TOILET 24 240 No 0 1 Yes Yes Yes 12 POWDER RM 34 340 No 0 1 No Yes Yes 13 M WIC 1 40 400 No 0 1 Yes Yes Yes 14 M WIC 2 45 450 No 0 1 Yes Yes Yes 15 MASTER BEDR00 238 2380 No 0 1 1 Yes Yes Yes 16 M HALL 20 200 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 3 16 It 186 ftz ---- 1 0 0 2 Slab -On -Grade Edge Insulation LAUNDRY RM 5 ft 140 ft2 ---- 1 0 0 3/3/202211:12 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab -On -Grade Edge Insulation CLST 2 2 ft 18 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 2 26 ft 168 ft2 1 0 0 5 Slab -On -Grade Edge Insulation BATH 2 1 ft 60 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation FAMILY RM 34 ft 432 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation KITCHEN 25 ft 311 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation HALLWAY 1 ft 52 W 1 0 0 9 Slab -On -Grade Edge Insulation PANTRY 6 ft 56 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation M BATH 20 ft 224 ft2 ____ 1 0 0 1 lSlab-On-Grade Edge Insulation M TOILET loft 24 ft2 ____ 1 0 0 1281ab-On-Grade Edge Insulation - POWDER RM 1 ft 34 ft2 1 0 0 13SIab-On-Grade Edge Insulation M W IC 1 8 ft 40 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation M W IC 2 14 ft 45 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation MASTER BEDRO 22 ft 238 ft2 -___ 1 0 0 16SIab-On-Grade Edge Insulation M HALL 1 ft 20 ft2 ____ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 2219 ft2 426 ft2 Light N 0.3 No 0.9 No 20 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2048 ft2 N N 3/31202211:12 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 3 0 Blown 186 ft2 0.1 Wood 2 Under Attic (Unvented) LAUNDRY RM 0 Blown 140 ft2 0.1 Wood 3 Under Attic (Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood 4 Under Attic (Unvented) BEDROOM 2 0 Blown 168 ft2 0.1 Wood 5 Under Attic (Unvented) BATH 2 0 Blown 60 ft2 0.1 Wood 6 Under Attic (Unvented) FAMILY RM 0 Blown 432 ft2 0.1 Wood 7 Under Attic (Unvented) KITCHEN 0 Blown 311 ft2 0.1 Wood 8 Under Attic (Unvented) HALLWAY 0 Blown 52 ft2 0.1 Wood 9 Under Attic (Unvented) PANTRY 0 Blown 56 ft2 0.1 Wood 10 Under Attic (Unvented) M BATH 0 Blown 224 ft2 0.1 Wood 11 Under Attic (Unvented) M TOILET 0 Blown 24 ft2 0.1 Wood 12 Under Attic (Unvented) POWDER RM 0 Blown 34ft2 0.1 Wood 13 Under Attic (Unvented) M WIC 1 0 Blown 40ft2 0.1 Wood 14 Under Attic (Unvented) M W IC 2 0 Blown 45 ft2 0.1 Wood 15 Under Attic (Unvented) MASTER BEDRO 0 Blown 238 ft2 0.1 Wood 16 Under Attic (Unvented) M HALL 0 Blown 20 ft2 0.1 Wood WALLS Adjacent )A/all Type Space Cavity Width Height Sheathing Framing Solar Belo w _ 1 S Exterior Concrete Block - PolystyMDROOM 3 0 16 0 10 0 160.0 ft2 0 0 0.3 0 _ 2 W Garage Frame - Wood BEDROOM 3 11 12 0 10 0 120.0 ft2 0 0.1 0.3 0 3 N Exterior Concrete Block - PolystydMUNDRY R 0 5 0 10 0 50.0 ft2 0 0 0.3 0 _ 4 W Garage Frame - Wood LAUNDRY R 11 10 0 10 0 100.0 ft2 0 0.1 0.3 0 5 S Exterior Concrete Block - PolystyrenDLST 2 0 2 0 10 0 20.0 ft2 0 0 0.3 0 _ 6 E Exterior Concrete Block - PolystySEBROOM 2 0 12 0 10 0 120.0 ft2 0 0 0.3 0 7 S Exterior Concrete Block - PolystyMDROOM 2 0 14 0 10 0 140.0 ft2 0 0 0.3 0 _ 8 E Exterior Concrete Block - PolystyrGrWILY RM 0 24 0 10 0 240.0 ft2 0 0 0.3 0 9 S Exterior Concrete Block - Polystyr€uNMILY RM 0 10 0 10 0 100.0 ft2 0 0 0.3 0 _ 10 N Exterior Concrete Block - Polystyrelfd:TCHEN 0 8 0 10 0 80.0 ft2 0 0 0.3 0 _ 11 W Exterior Concrete Block - PolystyreKtbTCHEN 0 17 0 10 0 170.0 ft2 0 0 0.3 0 _ 12 W Exterior Concrete Block - PolystyreWNTRY 0 6 0 10 0 60.0 ft2 0 0 0.3 0 _ 13 N Exterior Concrete Block - Polystyrerfd BATH 0 14 0 10 0 140.0 ft2 0 0 0.3 0 _ 14 W Exterior Concrete Block - Polystyrerfd BATH 0 6 0 10 0 60.0 ft2 0 0 0.3 0 15 N Exterior Concrete Block - PolystyrddleTOILET 0 6 0 10 0 60.0 ft2 0 0 0.3 0 16 W Exterior Concrete Block - Polystyrd&TOILET 0 4 0 10 0 40.0 ft2 0 0 0.3 0 _ 17 N Exterior Concrete Block - PolystyrerM W IC 1 0 8 0 10 0 80.0 ft2 0 0 0.3 0 18 N Exterior Concrete Block - PolystyrerM W IC 2 0 9 0 10 0 90.0 ft2 0 0 0.3 0 _ 19 E Exterior Concrete Block - PolystyrerM W IC 2 0 5 0 10 0 50.0 ft2 0 0 0.3 0 20 E Exterior Concrete Block - PolystyddMTER BE 0 14 0 10 0 140.0 ft2 0 0 0.3 0 _ 21 S Exterior Concrete Block - Polystydt6TER BE 0 8 0 10 0 80.0 ft2 0 0 0.3 0 _ 22 N Exterior Frame - Wood M BATH 13 19 0 5 0 95.0 ft2 0 0.1 0.3 0 23 S Exterior Frame - Wood FAMILY RM 13 19 0 5 0 95.0 ft2 0 0.1 0.3 0 3/3/202211:12 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Single Yes 0.31 0.19 Y 21.3 ft2 1 ft 4 in 1 ft 4 in None None 2 N 3 Vinyl Low-E Single Yes 0.31 0.19 Y 9.0 ft2 1 ft 4 in 1 ft 4 in None None 3 E 6 Vinyl Low-E Single Yes 0.31 0.19 Y 18.0 ft2 1 ft 4 in 1 ft 4 in None None 4 E 8 Vinyl Low-E Single Yes 0.31 0.19 Y 72.0 W 1 ft 4 in 1 ft 4 in None None 5 E 8 Vinyl Low-E Single Yes 0.31 0.19 Y 48.0 ft2 1 ft 4 in 1 ft 4 in None None 6 S 9 Vinyl Low-E Single Yes 0.31 0.19 Y 48.0 ft2 1 ft 4 in 1 ft 4 in None None 7 W 11 Vinyl Low-E Single Yes 0.31 0.19 Y 16.0 ft2 1 ft 4 in 1 ft 4 in None None 8 W 11 Vinyl Low-E Single Yes 0.26 0.24 Y 12.0 ft2 1 ft 4 in 1 ft 4 in None None 9 W 12 Vinyl Low-E Single Yes 0.26 0.24 Y 6.0 ft2 1 ft 4 in 1 ft 4 in None None 10 N 13 Vinyl Low-E Single Yes 0.31 0.19 Y 10.0 ft2 1 ft 4 in 1 ft 4 in None None 11 W 14 Vinyl Low-E Single Yes 0.26 0.24 Y 6.0 ft2 1 ft 4 in 1 ft 4 in None None 12 E 20 Vinyl Low-E Single Yes 0.31 0.19 Y 30.0 ft2 1 ft 4 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wail Height Exposed Wall Insulation 1 484 ft2 484 ft2 22 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000317 1706.7 93.63 175.79 .0987 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 36 kBtu/hr 1080 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Mode[ # Collector Model # Area Volume FEF None None ft2 3/3/202211:12 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY GIIEGKLI5 t KEPIUK DUCTS --- Supply-- ---- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Proposed Qn Garage -- cfm 163.8 cfm 0.08 0.50 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling[[ jj Jan Feb Heatin(X) Jan Feb Mar A r Mar APr May May Jun Jun Jul Jul Au Aug Se Sep JA Oct Oct JA Nov Nov Dec Dec Ventin [[ jj Jan Feb Mar A r [ l Ma Jun Jul [ Au L [ Se L Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 76 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 6B 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 HIS WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 LUGGAGE CLST Default(B Ibs/sq.ft. ft2 ft 0.3 POWDER RM Default(8lbs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ft2 ft 0.3 HER WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 M HALL Default(B Ibs/sq.ft. ft2 ft 0.3 OFFICE Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN/DINING Default(B Ibs/sq.ft. ft2 ft 0.3 UTILITY Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8lbs/sq.ft. ft2 ft 0.3 MUD RM WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(81bs/sq.ft ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 MUD RM Default(8 Ibs/sq.ft. ft2 ft 0.3 CABANA HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN/LIVING R Default(8 Ibs/sq.ft. ft2 ft 0.3 CABANA BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 BUNK CLST 3/3/2022 11:12 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ftz ft 0.3 BUNK RM Default(8lbs/sq.ft. f? ft 0.3 LINEN CLST Defoult(8 Ibs/sq.ft. ft2 ft 0.3 CABANA CLST Default 8 Ibsfs .ft. ftz ft 0.3 CABANA SEDROO 3/3/2022 11:12 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BRADY RESIDENCE Builder Name: HOMES BY ABURTON Street: GULLOTTI PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, Permit Number: Y U Owner: JACK AND LYNN BRADY Jurisdiction: ST LUCIE COUNTY W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be Insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class 1 vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ploina and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs, insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 3/3/2022 11:13 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1