HomeMy WebLinkAboutRevision 3-8-22OFFICE USE ONLY:
DATE FILED: :3• �
REVISION FEE: D d
PERMIT # SLC 2106-0267
RECEIPT #
PLANNING &DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772) 462-1553
APPLICATION FOR BUILDING PERM
PROJECT INFORMATION
REviSION
LOCATION/SITE ����
ADDRESS:
7153 Gullotti Place, Port Saint Lucie, FL 34952
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Per Wanda Gahn - Revised Energy Calcs showing exterior frame wall with R13.
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CGC1520713 ST. LUCIE CO CERT. #:
BUSINESS NAME: RA CONSTRUCTION CORP OF THE TREASURE COAST/HOMES BY ABURTON
QUALIFIERS NAME: Richard A. Adams III
ADDRESS: 850 N. Federal Hwy., Ste. 226
CITY: Stuart STATE: FL ZIP: 34994
PHONE (DAYTIME): 772-446-4576 FAX: 772-446-4514
OWNER/BUILDER INFORMATION:
NAME: John and Lynne Brady
ADDRESS: 523 Sweet Bay Circle
CITY: Jupiter
PHONE (DAYTIME: 561-317-6493
STATE: FL
ARCHITECT/ENGINEER INFORMATION:
NAME: Stanley Forrest
ADDRESS: 5000 Avenue Of The Stars
CITY: Kissimmee
PHONE (DAYTIME): 407-997-7890
SLCCC: 9123109
Revised 06130117
STATE: FL
FAX:
FAX:
ZIP: 33458
ZIP: 34746
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
GULLOTTI PLACE, PORT ST LUCIE, FL,
1. New construction or existing New (From Plans)
10. Wall Type and Insulation
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Polystyrene Bead Aggrd2=0.0 1880.00 ft2
b. Frame - Wood, Adjacent
R=11.0 220.00 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Exterior
R=13.0 190.00 ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Type and insulation level
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2048.00 ft2
6. Conditioned floor area (W) 2048
b. N/A
R= ft2
7. Description Area
c. N/A
R= ft2
a. U-Fa to
a. U-Factor: SH U=0.1 272.33 ft2
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 150
SHGC: SHGC=0.19
b. U-Factor: Sgl, U=0.26 24.00 ft2
SHGC: SHGC=0.24
13. Cooling systems
kBtu/hr Efficiency
c. U-Factor. N/A ft2
a. Central Unit
36.0 SEER:16.00
SHGC:
d. U-Factor: N/A ft2
14. Heating systems
kBtu/hr Efficiency
SHGC:
a. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth: 1.333 ft.
Area Weighted Average SHGC: 0.194
8. Skylights Description Area
15. Hot water systems
Cap: 50 gallons
a. U-Factor(AVG): N/A ft2
a. Electric
EF: 0.98
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area
None
a. Slab -On -Grade Edge Insulation R=0.0 2048.00 ft2
Credits (Performance method)
None
b. N/A R= ft2
c. N/A R= ft2
i
r
I certify that this home has co plied with Florida Energy
Construction through the, abov features
Efficiency Code for Building -,��
be installed v
T>r1E sa
oI
energy'saving which
5 -
will or exceeded
( )
in this home before final {1, �spe8 io�n!'Otherwise, anew EPL Display Card will be completed
based on installed Code c'ompii nt f atures.
1�
��
Builder Signature:
Date: 1�
,r
..:I
Address of New Home: �� � � LLo-m T�,
City/FL Zip: 0p2T•,s' j, "Cz
i
1•l
c vy�
FL ��l `� oD
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may quali
y efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the FI
ida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building
Code, Energy Conservation, if not DEFAULT.
3/3/2022 11:12 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
Page 1 of 1
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BRADY RESIDENCE
Builder Name: HOMES BY ABURTON
Street: GULLOTTI PLACE
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL,
Permit Number:
Owner: JACK AND LYNN BRADY
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Types(2290.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Polystyrene Bead AggreR=0.0 1880.00 ft2
b. Frame - Wood, Adjacent
R=11.0 220.00 ft2
3. Number of units, if multiple family 1
c. Frame -Wood, Exterior
R=13.0 190.00 ftz
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2048.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2048.00 ft2
6. Conditioned floor area above grade (ft2) 2048
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(296.3 sqft.) Description Area
12. Ducts
R ftz
a. Sup: Attic, Ret: Attic, AH: Garage
6 150
a. U-Factor: Sgl, U=0.31 272.33 ftz
SHGC: SHGC=0.19
b. U-Factor: Sgl, U=0.26 24.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.24
a. Central Unit
36.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.333 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.194
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2048.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2048.00 ft2
b. Conservation features
b. NIA R= ft2
None
c. N/A R= ft2
16. Credits
None
Total Proposed Modified Loads: 68.94
Glass/Floor Area: 0.145
PASS
Total Baseline Loads: 69.06
1 hereby certify that the plans and specifications covered by
Review of the plans and
Q�'CH5 S74
this calculation are in compliance with the Florida Energy
specifications covered by this
ti. O�
Code.
calculation indicates compliance
,`o
��i„f'`%° _ =s ,•��
PREPARED BY: N/C L>5 ${CI�GWLL
with the Florida Energy Code.
Before is
�r ��-: "f.•'°��� �O
LU
construction completed
DATE: -3-2 22 '
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
1i4'it O
I hereby certify that thisl ilding, as designed, is in compliance
with the Florida Energy ew 3`
SOU WL"
OWNER/AGENT: ; I
BUILDING OFFICIAL:
DATE: v
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as 1k
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this pro quires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH60 (R402.4.1.2).
- Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not.re��ti+ir R405
.2.3`��
3/3/202211:12 AM EriergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020 INPUT SUMMARY GNEGKLIST REPORT
PROJECT
Title:
BRADY RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2048
Lot #
Owner Name:
JACK AND LYNN BRADY
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
HOMES BY ABURTON
Rotate Angle: 0
Street:
GULLOTTI PLACE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Detached
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
v
Design Temp
Int Design Temp
Heating
Design
Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2048
20480
SPACES
Number
Name
Area
Volume. Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
BEDROOM 3
186
1860 No
0
1
1
Yes
Yes
Yes
2
LAUNDRY RM
140
1400 No
0
1
Yes
Yes
Yes
3
CLST 2
18
180 No
0
1
Yes
Yes
Yes
4
BEDROOM 2
168
1680 No
0
1
1
Yes
Yes
Yes
5
BATH 2
60
600 No
0
1
No
Yes
Yes
6
FAMILY RM
432
4320 No
0
1
Yes
Yes
Yes
7
KITCHEN
311
3110 Yes
0
1
Yes
Yes
Yes
8
HALLWAY
52
520 No
0
1
No
Yes
Yes
9
PANTRY
56
560 No
0
1
Yes
Yes
Yes
10
M BATH
224
2240 No
0
1
Yes
Yes
Yes
11
M TOILET
24
240 No
0
1
Yes
Yes
Yes
12
POWDER RM
34
340 No
0
1
No
Yes
Yes
13
M WIC 1
40
400 No
0
1
Yes
Yes
Yes
14
M WIC 2
45
450 No
0
1
Yes
Yes
Yes
15
MASTER BEDR00
238
2380 No
0
1
1
Yes
Yes
Yes
16
M HALL
20
200 No
0
1
No
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 3 16 It
186 ftz
----
1 0
0
2 Slab -On -Grade Edge Insulation LAUNDRY
RM 5 ft
140 ft2
----
1 0
0
3/3/202211:12 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
3 Slab -On -Grade Edge Insulation
CLST 2
2 ft
18 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
BEDROOM 2
26 ft
168 ft2
1
0
0
5 Slab -On -Grade Edge Insulation
BATH 2
1 ft
60 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
FAMILY RM
34 ft
432 ft2
____
1
0
0
7 Slab -On -Grade Edge Insulation
KITCHEN
25 ft
311 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
52 W
1
0
0
9 Slab -On -Grade Edge Insulation
PANTRY
6 ft
56 ft2
____
1
0
0
10SIab-On-Grade Edge Insulation
M BATH
20 ft
224 ft2
____
1
0
0
1 lSlab-On-Grade Edge Insulation
M TOILET
loft
24 ft2
____
1
0
0
1281ab-On-Grade Edge Insulation
- POWDER RM
1 ft
34 ft2
1
0
0
13SIab-On-Grade Edge Insulation
M W IC 1
8 ft
40 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
M W IC 2
14 ft
45 ft2
____
1
0
0
15SIab-On-Grade Edge Insulation
MASTER BEDRO 22 ft
238 ft2
-___
1
0
0
16SIab-On-Grade Edge Insulation
M HALL
1 ft
20 ft2
____
1
0
0
ROOF
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
# Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Gable or shed
Metal 2219 ft2
426 ft2 Light
N
0.3 No 0.9
No
20
22.62
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2048 ft2
N N
3/31202211:12 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) BEDROOM 3
0
Blown
186 ft2
0.1
Wood
2
Under Attic (Unvented) LAUNDRY RM
0
Blown
140 ft2
0.1
Wood
3
Under Attic (Unvented) CLST 2
0
Blown
18 ft2
0.1
Wood
4
Under Attic (Unvented) BEDROOM 2
0
Blown
168 ft2
0.1
Wood
5
Under Attic (Unvented) BATH 2
0
Blown
60 ft2
0.1
Wood
6
Under Attic (Unvented) FAMILY RM
0
Blown
432 ft2
0.1
Wood
7
Under Attic (Unvented) KITCHEN
0
Blown
311 ft2
0.1
Wood
8
Under Attic (Unvented) HALLWAY
0
Blown
52 ft2
0.1
Wood
9
Under Attic (Unvented) PANTRY
0
Blown
56 ft2
0.1
Wood
10
Under Attic (Unvented) M BATH
0
Blown
224 ft2
0.1
Wood
11
Under Attic (Unvented) M TOILET
0
Blown
24 ft2
0.1
Wood
12
Under Attic (Unvented) POWDER RM
0
Blown
34ft2
0.1
Wood
13
Under Attic (Unvented) M WIC 1
0
Blown
40ft2
0.1
Wood
14
Under Attic (Unvented) M W IC 2
0
Blown
45 ft2
0.1
Wood
15
Under Attic (Unvented) MASTER BEDRO
0
Blown
238 ft2
0.1
Wood
16
Under Attic (Unvented) M HALL
0
Blown
20 ft2
0.1
Wood
WALLS
Adjacent )A/all Type Space
Cavity
Width
Height
Sheathing Framing Solar
Belo w
_ 1
S
Exterior Concrete Block - PolystyMDROOM 3
0
16
0 10
0
160.0 ft2
0
0
0.3
0
_ 2
W
Garage Frame - Wood BEDROOM 3
11
12
0 10
0
120.0 ft2
0
0.1
0.3
0
3
N
Exterior Concrete Block - PolystydMUNDRY R
0
5
0 10
0
50.0 ft2
0
0
0.3
0
_ 4
W
Garage Frame - Wood LAUNDRY R
11
10
0 10
0
100.0 ft2
0
0.1
0.3
0
5
S
Exterior Concrete Block - PolystyrenDLST 2
0
2
0 10
0
20.0 ft2
0
0
0.3
0
_ 6
E
Exterior Concrete Block - PolystySEBROOM 2
0
12
0 10
0
120.0 ft2
0
0
0.3
0
7
S
Exterior Concrete Block - PolystyMDROOM 2
0
14
0 10
0
140.0 ft2
0
0
0.3
0
_ 8
E
Exterior Concrete Block - PolystyrGrWILY RM
0
24
0 10
0
240.0 ft2
0
0
0.3
0
9
S
Exterior Concrete Block - Polystyr€uNMILY RM
0
10
0 10
0
100.0 ft2
0
0
0.3
0
_ 10
N
Exterior Concrete Block - Polystyrelfd:TCHEN
0
8
0 10
0
80.0 ft2
0
0
0.3
0
_ 11
W
Exterior Concrete Block - PolystyreKtbTCHEN
0
17
0 10
0
170.0 ft2
0
0
0.3
0
_ 12
W
Exterior Concrete Block - PolystyreWNTRY
0
6
0 10
0
60.0 ft2
0
0
0.3
0
_ 13
N
Exterior Concrete Block - Polystyrerfd BATH
0
14
0 10
0
140.0 ft2
0
0
0.3
0
_ 14
W
Exterior Concrete Block - Polystyrerfd BATH
0
6
0 10
0
60.0 ft2
0
0
0.3
0
15
N
Exterior Concrete Block - PolystyrddleTOILET
0
6
0 10
0
60.0 ft2
0
0
0.3
0
16
W
Exterior Concrete Block - Polystyrd&TOILET
0
4
0 10
0
40.0 ft2
0
0
0.3
0
_ 17
N
Exterior Concrete Block - PolystyrerM W IC 1
0
8
0 10
0
80.0 ft2
0
0
0.3
0
18
N
Exterior Concrete Block - PolystyrerM W IC 2
0
9
0 10
0
90.0 ft2
0
0
0.3
0
_ 19
E
Exterior Concrete Block - PolystyrerM W IC 2
0
5
0 10
0
50.0 ft2
0
0
0.3
0
20
E
Exterior Concrete Block - PolystyddMTER BE
0
14
0 10
0
140.0 ft2
0
0
0.3
0
_ 21
S
Exterior Concrete Block - Polystydt6TER BE
0
8
0 10
0
80.0 ft2
0
0
0.3
0
_ 22
N
Exterior Frame - Wood M BATH
13
19
0 5
0
95.0 ft2
0
0.1
0.3
0
23
S
Exterior Frame - Wood FAMILY RM
13
19
0 5
0
95.0 ft2
0
0.1
0.3
0
3/3/202211:12 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
S 1 Vinyl
Low-E Single
Yes
0.31 0.19 Y
21.3 ft2 1 ft 4 in
1 ft 4 in
None
None
2
N 3 Vinyl
Low-E Single
Yes
0.31 0.19 Y
9.0 ft2 1 ft 4 in
1 ft 4 in
None
None
3
E 6 Vinyl
Low-E Single
Yes
0.31 0.19 Y
18.0 ft2 1 ft 4 in
1 ft 4 in
None
None
4
E 8 Vinyl
Low-E Single
Yes
0.31 0.19 Y
72.0 W 1 ft 4 in
1 ft 4 in
None
None
5
E 8 Vinyl
Low-E Single
Yes
0.31 0.19 Y
48.0 ft2 1 ft 4 in
1 ft 4 in
None
None
6
S 9 Vinyl
Low-E Single
Yes
0.31 0.19 Y
48.0 ft2 1 ft 4 in
1 ft 4 in
None
None
7
W 11 Vinyl
Low-E Single
Yes
0.31 0.19 Y
16.0 ft2 1 ft 4 in
1 ft 4 in
None
None
8
W 11 Vinyl
Low-E Single
Yes
0.26 0.24 Y
12.0 ft2 1 ft 4 in
1 ft 4 in
None
None
9
W 12 Vinyl
Low-E Single
Yes
0.26 0.24 Y
6.0 ft2 1 ft 4 in
1 ft 4 in
None
None
10
N 13 Vinyl
Low-E Single
Yes
0.31 0.19 Y
10.0 ft2 1 ft 4 in
1 ft 4 in
None
None
11
W 14 Vinyl
Low-E Single
Yes
0.26 0.24 Y
6.0 ft2 1 ft 4 in
1 ft 4 in
None
None
12
E 20 Vinyl
Low-E Single
Yes
0.31 0.19 Y
30.0 ft2 1 ft 4 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wail Height
Exposed Wall Insulation
1
484 ft2
484 ft2
22 ft
loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000317
1706.7 93.63 175.79 .0987
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16
36 kBtu/hr 1080 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric
None
Garage
0.98 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cent # Company Name
System Mode[ # Collector Model #
Area
Volume
FEF
None None
ft2
3/3/202211:12 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020
INPUT SUMMARY GIIEGKLI5 t KEPIUK
DUCTS
--- Supply--
---- Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6
150 ft2 Attic
15 ft2
Proposed Qn
Garage
-- cfm
163.8 cfm 0.08
0.50
1 1
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
Cooling[[ jj Jan Feb
Heatin(X) Jan Feb
Mar A r
Mar APr
May
May
Jun
Jun
Jul
Jul
Au
Aug
Se
Sep
JA Oct
Oct JA
Nov
Nov
Dec
Dec
Ventin [[ jj Jan
Feb
Mar A r
[
l
Ma
Jun
Jul
[ Au
L
[ Se
L
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (W D)
AM
78
78
78
78
78
78
78
76
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Heating (W D)
AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
6B 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
HIS WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LUGGAGE CLST
Default(B Ibs/sq.ft.
ft2
ft
0.3
POWDER RM
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
ft2
ft
0.3
HER WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M HALL
Default(B Ibs/sq.ft.
ft2
ft
0.3
OFFICE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN/DINING
Default(B Ibs/sq.ft.
ft2
ft
0.3
UTILITY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8lbs/sq.ft.
ft2
ft
0.3
MUD RM WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(81bs/sq.ft
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MUD RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CABANA HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN/LIVING
R
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CABANA BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BUNK CLST
3/3/2022 11:12 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BUNK RM
Default(8lbs/sq.ft.
f?
ft
0.3
LINEN CLST
Defoult(8 Ibs/sq.ft.
ft2
ft
0.3
CABANA CLST
Default 8 Ibsfs .ft.
ftz
ft
0.3
CABANA SEDROO
3/3/2022 11:12 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: BRADY RESIDENCE Builder Name: HOMES BY ABURTON
Street: GULLOTTI PLACE Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL, Permit Number:
Y
U
Owner: JACK AND LYNN BRADY Jurisdiction: ST LUCIE COUNTY
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be Insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous Insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class 1 vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ploina and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs,
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
3/3/2022 11:13 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1