APPROVED MANJ
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Load Short Form 6/23/2021Date:Entire House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Bove Residence, Groza Builders, IncFor: 123 Eden Creek Ln, Jensen Beach, FL 34957 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW8.9 Sensible cooling Btuh24220 Heating output Btuh30349 Latent cooling Btuh10380 Temperature rise °F24 Total cooling Btuh34600 Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.054 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.73 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Flex Room 210 3228 2044 133 110 Foyer 116 960 351 40 19 Bath 61 585 170 24 9 Bed 2 247 3374 1889 139 102 Bed 3 193 1517 873 62 47 WIC 3 36 589 158 24 9 Laundry 47 70 651 3 35 Wtr Clst 23 278 69 11 4 WIC 40 594 161 24 9 M Bath 154 1627 442 67 24 M Hall 20 0 0 0 0 Master Bed 276 4769 3091 196 167 Bed 4 188 2997 1682 123 91 Bath 2 95 1922 556 79 30 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 2 ...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N Hall 33 0 0 0 0 Pantry 27 0 0 0 0 KitNook 298 2121 3312 87 179 Great Room 440 2777 5785 114 312 Hall 2 25 0 0 0 0 Lin2 9 0 0 0 0 WIC 2 42 597 163 25 9 Entire House 2577 28002 21395 1153 1153 Other equip loads 2016 1071 Equip. @ 0.95 RSM 21432 Latent cooling 8290 TOTALS 2577 30019 29723 1153 1153 2021-Jun-24 09:43:50 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Building Analysis 6/23/2021Date:Entire House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Bove Residence, Groza Builders, IncFor: 123 Eden Creek Ln, Jensen Beach, FL 34957 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 16.148452.6Walls 7.3220210.0Glazing 0.82383.7Doors 8.525451.0Ceilings 23.570562.72.7Floors 13.239642.2Infiltration 23.87153Ducts 00Piping 00Humidification 6.72016Ventilation0Adjustments 100.030019Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 13.129501.6Walls 22.0494622.5Glazing 1.12413.7Doors 7.015620.6Ceilings 000Floors 4.710520.6Infiltration 22.95143Ducts 4.81071Ventilation 24.55500Internal gains 00Blower 0Adjustments 100.022466Total Latent Cooling Load = 8290 Btuh Overall U-value = 0.080 Btuh/ft²-°F ERROR: negative wall area in Great Room - check windows. 2021-Jun-24 09:43:50 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Component Constructions 6/23/2021Date:Entire House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Bove Residence, Groza Builders, IncFor: 123 Eden Creek Ln, Jensen Beach, FL 34957 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Block R-9 Wall: Blk wall, Stuc Ext, 8" thk, R-9 Foam Fill, 1/2" Gyp Bd 9002.589.00.089350n 5761.65 3821.655972.589.00.089232e 7811.6512222.589.00.089474s 5861.659162.589.00.089356w 23251.6536362.589.00.0891411all Block R-9 Wall: Frm Wall, Stucco , R-30, 1/2" Gyp Bd Int Fnsh, 2"x4" , 16" O.C. Stud 511.31802.0430.00.07139e 51.3182.0430.00.0714s 521.31822.0430.00.07140w 1091.311702.0430.00.07183all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 5161.4610392.9411.00.101354 Windows Impact: Impact; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (0.67 ft window ht, 1 ft sep.); 6.8 ft head ht 137.59159.2800.3202n Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (6 ft window ht, 1 ft sep.); 6.8 ft head ht 81422.03228.7000.30037e Impact: Impact; NFRC rated (SHGC=0.19); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.25 ft window ht, 1 ft sep.); 6.8 ft head ht 47820.62088.9900.31023e Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht 1459.311368.7000.30016s 102922.04078.7000.30047w 117418.85438.7000.30062all Impact: Impact; NFRC rated (SHGC=0.20); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 8.7 ft overhang (8 ft window ht, 1 ft sep.); 6.8 ft head ht 126013.1111411.600.40096w Doors 2021-Jun-24 09:43:50 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 2 ...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N Fbrgls Door 793.73793.697.00.12721n 893.73893.697.00.12724e 723.73713.697.00.12719s 2413.732383.697.00.12765all Ceilings Attic, Metal Roof, R-30 Ceil Ins, 5/8" Gyp Bd 0.0342577 15620.6125450.9930.0 Floors On Grade Depth, Tile Flr Fnsh 00705628.700.989246 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Project Summary 6/23/2021Date:Entire House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Bove Residence, Groza Builders, IncFor:123 Eden Creek Ln, Jensen Beach, FL 34957 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh20849 Structure Btuh16252 Ducts Btuh7153 Ducts Btuh5143Central vent (63 cfm) 2016 Btuh Central vent (63 cfm) Btuh1071 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh30019 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh21432 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3403 Ducts Btuh2442Central vent (63 cfm) Btuh2445 CoolingHeating Outside air25772577Area (ft²) Equipment latent load Btuh8290 2331923319Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh29723 Equiv. AVF (cfm) 62124 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond ML14XC1S036-230C**AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW8.9 Sensible cooling Btuh24220Heating output Btuh30349 Latent cooling Btuh10380 Temperature rise °F24 Total cooling Btuh34600Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.054Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.73 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Entire House Flex Room 2 Exposed wall 246.0 ft 29.5 ft 3 Room height 9.0 ft 10.0 heat/coolft 4 Room dimensions ft17.5x12.0 5 Room area 2577.3 ft²210.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 373 350 900 576 0 0 0 0 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 2 0 15 13 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 21 21 79 79 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 316 232 597 382 96 59 152 97 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 37 0 322 814 37 0 322 814 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 23 0 208 478 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 24 24 89 89 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 39 39 80 51 24 24 49 31 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 509 474 1222 781 16 16 41 26 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 16 13 136 145 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 19 19 71 72 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 4 4 8 5 4 4 8 5 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 499 356 916 586 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 47 0 407 1029 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 96 75 1114 1260 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 40 40 82 52 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 354 354 1039 516 155 155 455 226 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 2577 2577 2545 1562 210 210 207 127 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 2577 246 7056 0 210 30 846 0 6 c) AED excursion 1208 137 Envelope loss/gain 16886 9699 2081 1464 12 a) Infiltration 3964 1052 312 83 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 5 1150 0 0 Appliances/other 4350 0 Subtotal (lines 6 to 13)20849 16252 2393 1547 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 10 6 14 Subtotal 20849 16252 2403 1552 15 Duct loads 34%32%7153 5143 34%32%824 491 Total room load 28002 21395 3228 2044 Air required (cfm)Air required (cfm)1153 1153 133 110 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 2...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Foyer Bath 2 Exposed wall 7.5 ft 5.5 ft 3 Room height 10.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft15.5x7.5 ft11.0x5.5 5 Room area 116.3 ft²60.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 60 36 93 59 44 44 113 73 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 24 24 89 89 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 15 15 31 20 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 116 116 115 70 61 61 60 37 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 116 8 215 0 61 6 158 0 6 c) AED excursion -20 -10 Envelope loss/gain 542 219 331 100 12 a) Infiltration 167 44 98 26 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)709 263 429 126 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 5 3 7 4 14 Subtotal 714 266 436 129 15 Duct loads 34%32%245 84 34%32%149 41 Total room load 960 351 585 170 Air required (cfm)Air required (cfm)40 19 24 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 3...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 2 Bed 3 2 Exposed wall 31.5 ft 12.5 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft17.0x14.5 ft193.3x1.0 5 Room area 246.5 ft²193.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 116 93 239 153 0 0 0 0 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 23 0 208 478 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 136 136 350 224 100 84 217 139 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 16 13 136 145 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 247 247 243 149 193 193 191 117 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 247 32 903 0 193 13 359 0 6 c) AED excursion 28 -50 Envelope loss/gain 1945 1032 903 352 12 a) Infiltration 561 149 223 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 250 250 Subtotal (lines 6 to 13)2506 1431 1125 661 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 5 3 4 2 14 Subtotal 2512 1435 1129 663 15 Duct loads 34%32%862 454 34%32%387 210 Total room load 3374 1889 1517 873 Air required (cfm)Air required (cfm)139 102 62 47 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 4...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name WIC 3 Laundry 2 Exposed wall 6.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x6.0 ft8.5x5.5 5 Room area 36.0 ft²46.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 48 48 124 79 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 36 36 36 22 47 47 46 28 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 36 6 172 0 47 0 0 0 6 c) AED excursion -9 -37 Envelope loss/gain 331 92 46 -9 12 a) Infiltration 107 28 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)438 120 46 491 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 6 3 14 Subtotal 438 120 52 494 15 Duct loads 34%32%150 38 34%32%18 156 Total room load 589 158 70 651 Air required (cfm)Air required (cfm)24 9 3 35 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 5...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Wtr Clst WIC 2 Exposed wall 3.5 ft 6.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.5x3.5 ft40.0x1.0 5 Room area 22.8 ft²40.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 48 48 124 79 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 28 28 82 41 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 23 23 22 14 40 40 39 24 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 23 4 100 0 40 6 172 0 6 c) AED excursion -4 -9 Envelope loss/gain 205 51 335 94 12 a) Infiltration 0 0 107 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)205 51 442 122 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 2 1 0 0 14 Subtotal 207 52 442 122 15 Duct loads 34%32%71 16 34%32%152 39 Total room load 278 69 594 161 Air required (cfm)Air required (cfm)11 4 24 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 6...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name M Bath M Hall 2 Exposed wall 18.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft153.8x1.0 ft4.5x4.5 5 Room area 153.8 ft²20.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 52 50 130 83 0 0 0 0 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 2 0 15 13 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 92 92 270 134 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 154 154 152 93 20 20 20 12 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 154 18 516 0 20 0 0 0 6 c) AED excursion -25 -1 Envelope loss/gain 1083 298 20 11 12 a) Infiltration 116 31 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1199 329 20 11 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 12 7 -20 -11 14 Subtotal 1211 335 0 0 15 Duct loads 34%32%415 106 34%32%0 0 Total room load 1627 442 0 0 Air required (cfm)Air required (cfm)67 24 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 7...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Bed Bed 4 2 Exposed wall 44.0 ft 29.0 ft 3 Room height 8.5 heat/coolft 8.0 heat/coolft 4 Room dimensions ft275.9x1.0 ft187.5x1.0 5 Room area 275.9 ft²187.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 145 145 372 238 0 0 0 0 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 85 66 169 108 124 124 319 204 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 19 19 71 72 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 145 113 292 187 108 92 238 152 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 31 0 271 686 16 0 136 343 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 276 276 272 167 188 188 185 114 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 276 44 1262 0 188 29 832 0 6 c) AED excursion 164 74 Envelope loss/gain 2710 1623 1710 888 12 a) Infiltration 833 221 517 137 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 500 250 Subtotal (lines 6 to 13)3544 2344 2227 1275 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 7 4 5 3 14 Subtotal 3551 2348 2232 1278 15 Duct loads 34%32%1218 743 34%32%766 404 Total room load 4769 3091 2997 1682 Air required (cfm)Air required (cfm)196 167 123 91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 8...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bath 2 Hall 2 Exposed wall 19.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft10.0x9.5 ft33.0x1.0 5 Room area 95.0 ft²33.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 80 59 151 97 0 0 0 0 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 21 21 79 79 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 76 76 196 125 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 95 95 94 58 33 33 33 20 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 95 20 559 0 33 0 0 0 6 c) AED excursion -32 -1 Envelope loss/gain 1079 327 33 19 12 a) Infiltration 348 92 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1426 419 33 19 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 5 3 -33 -19 14 Subtotal 1431 422 0 0 15 Duct loads 34%32%491 134 34%32%0 0 Total room load 1922 556 0 0 Air required (cfm)Air required (cfm)79 30 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 9...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Pantry KitNook 2 Exposed wall 0 ft 18.0 ft 3 Room height 10.5 heat/coolft 10.5 heat/coolft 4 Room dimensions ft3.0x9.0 ft297.6x1.0 5 Room area 27.0 ft²297.6 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 89 89 230 147 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 0 0 0 0 21 21 43 27 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 79 79 231 115 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 27 27 27 16 298 298 294 180 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 27 0 0 0 298 18 516 0 6 c) AED excursion -1 -190 Envelope loss/gain 27 15 1314 280 12 a) Infiltration 0 0 246 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 2 460 Appliances/other 0 1700 Subtotal (lines 6 to 13)27 15 1560 2505 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -27 -15 19 11 14 Subtotal 0 0 1579 2516 15 Duct loads 34%32%0 0 34%32%542 796 Total room load 0 0 2121 3312 Air required (cfm)Air required (cfm)0 0 87 179 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 10...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Great Room Hall 2 2 Exposed wall 9.5 ft 0 ft 3 Room height 10.5 heat/coolft 8.0 heat/coolft 4 Room dimensions ft439.5x1.0 ft4.5x5.5 5 Room area 439.5 ft²24.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 81 -15 -39 -25 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 96 75 1114 1260 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 19 19 39 25 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 440 440 434 266 25 25 24 15 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 440 10 272 0 25 0 0 0 6 c) AED excursion 1204 -1 Envelope loss/gain 1820 2730 24 14 12 a) Infiltration 222 59 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 3 690 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13)2042 4379 24 14 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 26 15 -24 -14 14 Subtotal 2067 4394 0 0 15 Duct loads 34%32%709 1391 34%32%0 0 Total room load 2777 5785 0 0 Air required (cfm)Air required (cfm)114 312 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-24 09:43:50Right-Suite® Universal 2021 21.0.07 RSU27054 Page 11...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Right-J® Worksheet 6/23/2021Date:Entire House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Lin2 WIC 2 2 Exposed wall 0 ft 6.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft3.0x3.0 ft6.0x7.0 5 Room area 9.0 ft²42.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 48 48 124 79 .GG ImpactImpact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.6220.62 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ee 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ss 2.042.04 1.311.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.4000.400 ww 11.6011.60 13.1213.12 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0710.071 ww 2.042.04 1.311.31 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 9 9 9 5 42 42 41 25 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 9 0 0 0 42 6 172 0 6 c) AED excursion 0 -9 Envelope loss/gain 9 5 337 95 12 a) Infiltration 0 0 107 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)9 5 444 124 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -9 -5 0 0 14 Subtotal 0 0 444 124 15 Duct loads 34%32%0 0 34%32%152 39 Total room load 0 0 597 163 Air required (cfm)Air required (cfm)0 0 25 9 2021-Jun-24 09:43:51 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Duct System Summary 6/23/2021Date:Entire House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Bove Residence, Groza Builders, IncFor: 123 Eden Creek Ln, Jensen Beach, FL 34957 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.523 / 0.177 in H2O in H2O0.523 / 0.177 Lowest friction rate in/100ft0.256in/100ft0.256 Actual air flow cfm1153cfm1153 Total effective length (TEL) ft273 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st6140.054.3VlFx0x04.00.2691129585hBath st5140.059.1VlFx0x06.00.26336951922hBath 2 st6140.061.2VlFx0x07.00.2601221673374hBed 2 st5140.062.1VlFx0x05.00.25956751517hBed 3 st5140.061.2VlFx0x07.00.2601091482997hBed 4 st2100.031.3VlFx0x07.00.3981321603228hFlex Room st6140.051.7VlFx0x04.00.2732347960hFoyer st2100.030.9VlFx0x07.00.399187692892cGreat Room st2100.034.7VlFx0x07.00.388187692892cGreat Room-A st2100.025.0VlFx0x06.00.418107521656cKitNook st2100.031.6VlFx0x06.00.397107521656cKitNook-A st5140.057.3VlFx0x04.00.265423651cLaundry st195.011.0VlFx0x05.00.49329801627hM Bath st3120.034.2VlFx0x06.00.3391001182385hMaster Bed st3120.033.8VlFx0x06.00.3401001182385hMaster Bed-A st195.014.8VlFx0x04.00.4761029594hWIC st1100.019.2VlFx0x04.00.4391129597hWIC 2 st5140.063.9VlFx0x04.00.2561029589hWIC 3 st195.012.5VlFx0x04.00.486414278hWtr Clst 2021-Jun-24 09:43:51 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 2 ...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st5 Peak AVF 351 254 0.256 794 9.0 0x0 VinlFlx st4 st6 Peak AVF 243 156 0.260 696 8.0 0x0 VinlFlx st4 st4 Peak AVF 594 409 0.256 756 12.0 0x0 VinlFlx st2 st3 Peak AVF 236 200 0.339 675 8.0 0x0 VinlFlx st1 st1 Peak AVF 389 254 0.339 880 9.0 0x0 VinlFlx st2 Peak AVF 995 1130 0.256 809 16.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb9 0x 6680 823 69.1 0.256 589 16.0 x0 0 VlFx rb5 0x 2650 210 0 0 0 0 x0 0 VlFx rb4 0x 1770 119 0 0 0 0 x0 0 VlFx rb3 0x 1070 110 0 0 0 0 x0 0 VlFx rb2 0x 1670 122 0 0 0 0 x0 0 VlFx 2021-Jun-24 09:43:51 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...nts\Wrightsoft HVAC\123 Eden Creek Lane GBI.rup Calc = MJ8 Front Door faces: N 1537Job:Manual S Compliance Report 6/23/2021Date:Entire House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Bove Residence, Groza Builders, IncFor: 123 Eden Creek Ln, Jensen Beach, FL 34957 Cooling Equipment Design Conditions °F76.4Entering coil DB:Btuh22466Sensible gain:°F90.4Outdoor design DB: °F64.0Entering coil WB:Btuh8290Latent gain:°F77.4Outdoor design WB: Btuh30756Total gain:°F75.0Indoor design DB: cfm1153Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: ML14XC1S036-230C**+CBA27UHE-036-230*++TDRModel:LennoxManufacturer: cfm1153Actual airflow: % of load108Btuh24220Sensible capacity: % of load125Btuh10380Latent capacity: %70SHR:% of load112Btuh34600Total capacity: Heating Equipment Design Conditions °F67.8Entering coil DB:Btuh30019Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm1153Actual airflow: °F50Temp. rise:% of load101kW8.9Output capacity: Meets all requirements of ACCA Manual S.