Loading...
HomeMy WebLinkAbout2021-09-30 Site PlanC O M M E R C I A L C I R C L E15'10'15'5' D.E.10' U.E.30' D.E.15'15'30'19.86'20.12'20.10'20.37'45.33'45.26'57.35'57.67'(P.B. 32, PG. 5)26'45'10'16'10'18'12'16'30'29'60'20'21-321 CHEMTECH SITE PLAN AMENDMENT REVISION COMMENTSDATE 8 www.edc-inc.comF.B.P.E. CERTIFICATE OF AUTHORIZATION 9935L.B. CERTIFICATE OF AUTHORIZATION 8098ENGINEERS SURVEYORSENVIRONMENTAL10250 VILLAGE PARKWAYUNIT 201PORT ST. LUCIE, FL 34987' 772-462-2455ST. LUCIE COUNTY FLORIDAOF 1Z:\EDC-2021\21-321 - Chemtech - 7397 Commercial Circle\ENGINEERING\AutoCAD\DWGs\21-321 SPA 9-30-21.dwg, 9/30/2021 3:28 PMCOPYRIGHT: 2020 BY EDC-INC: THIS FIRM EXPRESSLY RESERVES THEIR EXCLUSIVE COMMON LAW COPYRIGHT AND INTELLECTUAL PROPERTY RIGHTS TO THESE DRAWINGS WHICH MAY NOT BE DISPERSED, REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER, NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT THE WRITTEN CONSENT OF THIS FIRM.THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY EDC, INC. SHALL BE WITHOUT LIABILITY TO EDC, INC.1VER AT AUGUST 2, 2021 DRAWN BY DESIGNED BY DATE COMMERCIAL CIRCLESITE DATAPROPERTY DATALEGAL DESCRIPTION:LOT 22, BLOCK B OF KINGS HIGHWAY INDUSTRIAL PARK UNIT TWO, ACCORDING TOTHE PLAT THEREOF AS RECORDED IN PLAT BOOK 32, PAGE(S) 5 AND 5A, OF THEPUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA.CONTAINING 1.38 ACRES, MORE OR LESS.PROPERTY SIZE:1.38 ACPARCEL ID1335-802-0044-000-4ADDRESS:7397 COMMERCIAL CIRCLEFORT PIERCE, FL 34951SECTION/TOWNSHIP/RANGE:35/34S/39EFUTURE LAND USE:TOWNS, VILLAGES, & COUNTRYSIDE (TVC)ZONING:INDUSTRIAL LIGHT (IL)FLOOD ZONE:FLOOD ZONE X PER FEMA MAP 12111C01260JBUILDING DATAEXISTING 1 STORYGROSS AREA:15,490 SFBUILDING SETBACKSFRONT:25SIDE:10REAR:20BUILDING HEIGHTMAXIMUM ALLOWED:50BUILDING COVERAGEPROPOSED:15,490 SF25.7%MAXIMUM ALLOWED:30,056 SF50%PARKING REQUIREMENTSREQUIRED PARKING(LAND USE 140-MANUFACTURING):16 SPACESPROPOSED PARKING:16 SPACESREQUIRED HANDICAP:1 SPACESPROPOSED HANDICAP:2 SPACESLOADING SPACE REQUIREMENTS1 SPACE/15,000-24,999 S.F. (WAREHOUSE)IMPERVIOUS/PERVIOUS DATATOTAL AREA:60,112 SF1.38 AC100%IMPERVIOUS40,595 SF0.93 AC67.53%PAVING23,549 SF0.54 AC39.17%CONCRETE:1,556 SF0.036 AC2.66%BUILDING:15,490 SF0.35 AC25.7%PERVIOUS19,517 SF0.45 AC32.47%OPEN SPACE:19,517 SF0.45 AC31.56%RETENTION :OFFSITEPROJECT NOTESPARKING DATA CALCULATIONS ACQUIRED FROM THE ITE PARKGEN WEB-BASEDAPP. PARKING GENERATION MANUAL, 5TH EDITIONSTORM WATER DRAINAGE: STORMWATER SHEET FLOWS FROM SOUTH TO THENORTH, EXITING THE SITE VIA EXISTING FLUMES WHICH DIRECT THESTORMWATER TO THE EXISTING MASTER STORMWATER MANAGEMENT SYSTEMTHAT HAS AN UNDERLYING ERP# 56-00599-S.PROJECT WILL UTILIZE EXISTING WATER & WASTEWATER PROVIDED.UTILITY PROVIDERWATER:FPUAWASTE WATER:FPUANEAREST FIRE HYDRANT LOCATIONS:270' EAST OF NORTHEAST PROPERTY CORNER ALONG COMMERCIAL CIRCLE300' EAST OF SOUTHEAST PROPERTY CORNER ALONG COMMERCIAL CIRCLE750' SOUTH OF SOUTHEAST PROPERTY CORNER ALONG COMMERCIAL CIRCLE245' WEST OF NORTHWEST PROPERTY CORNER ALONG COMMERCIAL CIRCLE770' SOUTH OF SOUTHWEST PROPERTY CORNER ALONG COMMERCIAL CIRCLELEGENDEXISTING METERPROPOSED MITEREDEND SECTIONPROPOSEDSIGNHANDICAP PARKING SYMBOLEXISTING CONCRETEEXISTING UTILITY POLEEXIST. DRAINAGE INLETEXISTING STREET LIGHTPROPOSED LIGHT POLE (SINGLE)DRAINAGE FLOW ARROWPROPOSED LIGHT POLE (DOUBLE)PARKING STALL COUNTLEGENDMEEXISTING METERPROPOSED MITEREDEND SECTIONPROPOSEDSIGNHANDICAP PARKING SYMBOLEXISTING CONCRETEPROPOSED PAVERSPROPOSED CONCRETEEXISTING UTILITY POLEPROPOSED DRAINAGE INLETEXIST. DRAINAGE INLETEXISTING STREET LIGHTPROPOSED LIGHT POLE (SINGLE)DRAINAGE FLOW ARROWPROPOSED LIGHT POLE (DOUBLE)PARKING STALL COUNTEXISTING DRAINAGEPROPOSED DRAINAGE PIPEPROPOSED PAVEMENTVICINITY MAPSCALE: 1" = 500'PROJECT LOCATIONXX.XXSPOT ELEVATIONSPACESCOMMERCIAL CIRCLEL-20L-20FPFWCD CANALAS SHOWN SCALE 21-321 spa 9-30-21.dwg FILENAME SPA LAYOUT10250 SW VILLAGE PARKWAY - SUITE 201PORT SAINT LUCIE, FL 34987' 772-462-2455EXISTINGWAREHOUSE FACILITY15,440 S.F.FFE. : 18.60 NAVDMAX. HGT. = 22'-2"PROPERTY LINEADJACENT PARCELSTORMWATER MANAGEMENTTRACTLAND USE:ZONING:ILINDADJACENT PARCELLOT 21 BLOCK "B"(VACANT)LAND USE:ZONING:ILINDADJACENT PARCELLOT 23 BLOCK "B"(OCCUPIED)LAND USE:ZONING:ILINDADJACENT PARCELLOTS 36 & 37 BLOCK "A"(OCCUPIED)LAND USE:ZONING:ILINDPROPERTY LINEPROPERTY LINEPROPERTY LINEEXISTING TOP OF BANKEXISTINGCONCRETE PAD (TYP.)EXISTINGYARD DRAIN (TYP.)PROPOSEDOVERHEAD BRIDGE CRANE& SOAKING TANKSEXISTING DUMPSTERTO BE RELOCATEDEXISTING FIRE HYDRANTASSEMBLYPROPOSEDOUTDOOR STORAGEPROPOSEDOUTDOOR STORAGEEXISTINGPORTION OF ISLANDTO BE REMOVEDEXISTING PORTION OF ISLANDWITH TYPE "D" CURB TO REMAINEXISTINGPARKING LOT LIGHT POLEEXISTING5' WIDE SIDEWALKEXISTING3/4" WATER SERVICESEXISTINGCONCRETE FLUMEEXISTINGCONCRETE FLUMEEXISTINGCONCRETE FLUMEPROPOSED CODECOMPLIANT 12' X 12'SINGLE DUMPSTEREXISTING PARKINGLIGHT POLEEXISTING ROW OF STRIPINGTO BE REMOVEDEXISTINGLOADING ZONETO BE RELOCATED2' OVERHANG1033PROPOSED 12" X 30'LOADING ZONEEXISTING6' HIGH CONCRETEWALL TO REMAINEXISTING MULTI BANKWATER METERSEXISTING FDCEXISTINGGATE2' OVERHANG18' PARKING STALL DETAILFTP-20-06 & FTP-22-06FTP-20-06 & FTP-22-06HANDICAPPED SPACE DETAILNOTES:1. FTP 20-06: TOP PORTION SHALL HAVE REFLECTIVE BLUE BACKGROUNDWITH WHITE REFLECTIVE SYMBOL AND BORDER. BOTTOM PORTION SHALLHAVE A REFLECTIVE WHITE BACKGROUND WITH BLACK OPAQUE LEGENDAND BORDER.2.FTP 21-06: TOP PORTION SHALL HAVE REFLECTIVE BLUE BACKGROUNDWITH WHITE REFLECTIVE SYMBOL AND BORDER. BOTTOM PORTION SHALLHAVE A REFLECTIVE WHITE BACKGROUND WITH BLACK OPAQUE LEGENDAND BORDER.3. FTP 20-06 IS FOR USE IN AREAS WHERE SPACE IS LIMITED.4. FTP 22-06 IS SUPPLEMENTAL PANEL FOR THE FTP 20-06 & FTP 21-06 SIGNS.5. HEIGHT SHALL BE 7 FEET MEASURED FROM THE GROUND OR SIDEWALK TOTHE BOTTOM OF "PERMIT ONLY" SIGN OR 6 FEET TO THE BOTTOM OF "$250FINE" SIGN.6. REFER TO FDOT INDEX No. 711-001 FOR PAVEMENT MARKING DETAILS &FDOT INDEX No. 700-102 SIGN DETAILS PER THE LATEST FDOT DESIGNSTANDARDS.PARKING BYDISABLEDPERMITONLYPARKING BYDISABLEDPERMITONLYFINE$250 MAXFINE$250 MAXFTP 20-06FTP 21-06FTP 22-06FTP 22-06GENERAL NOTES:A) ALL PARKING SPACES WITH EXCEPTION OF HANDICAPPED PARKING SPACES SHALL BEMARKED IN WHITE, RETRO-REFLECTIVE TRAFFIC PAINT AND BE IN ACCORDANCE WITH THEFLORIDA DEPARTMENT OF TRANSPORTATION (FDOT) STANDARD SPECIFICATIONS FORROAD AND BRIDGE CONSTRUCTION,2010 SECTION 710.B) ALL HANDICAPPED PARKING SPACES SHALL BE PROPERLY SIGNED AND STRIPED INACCORDANCE WITH THE FDOT STANDARD INDEX 17346, FY 2017-18.C) ALL COMPACT SPACES SHALL BE MARKED "COMPACT" ON THE STALL OR TIRE STOP.1. Use 3,000 P.S.I. concrete at 28 days for construction.NOTES:R=2"R=3/4" 6"6"8"18"TYPE "D" CURB2. Subgrade to extend an additional 6" beyond Type "D" Curb.Base6"3. Type "D" Curb to be constructed in accordance with FDOT Index #522-001.Pav'tSubgradeTYPE "D"CURB12' x 12' DUMPSTER DETAILEXISTING PAVEMENTEXISTINGTYPE D CURBEXISTINGTYPE D CURBEXISTINGTYPE D CURBEXISTING5' WIDE SIDEWALKEXISTINGSANITARYCLEANOUTEXISTINGSANITARYCLEANOUTEXISTINGFIRE SERVICE ASSEMBLYEXISTING 8" PVC SANITARYSEWER MAINEXISTING 8" PVCWATER MAIN