Loading...
HomeMy WebLinkAbout2022-02-01_CHEM TECH HOLDING_CRANE STRUCTURAL-Rev1-SEALEDAB ANCHOR BOLT A.F.F. ABOVE FINISH FLOOR ADJ ADJACENT AL ALUMINUM ARCH ARCHITECTURAL ATT ATTACHED BD BOARD BLDG BUILDING BM BEAM BOT BOTTOM BLKG BLOCKING BRG BEARING CJ CONTROL JOINT CL CENTERLINE CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE COND CONDITION CONT CONTINUOUS CONST CONSTRUCTION CSK COUNTERSINK C.O. CASED OPENING C.T. CERAMIC TILE CLG CEILING C.M. CROWN MOULD C.R. CHAIR RAIL D DRYER d PENNY DBL DOUBLE DET DETACHED DIA DIAMETER DIR DIRECTION DN DOWN DR DOOR DW DISHWASHER DWG DRAWING DS DOWNSPOUT DTL DETAIL EA EACH EXP JT EXPANSION JOINT ELEC ELECTRICAL EL ELEVATION EQ EQUAL EQUIP EQUIPMENT EXP EXPANSION EXT EXTERIOR FD FLOOR DRAIN FDN FOUNDATION FL FLOOR FP FIREPLACE FR FRAME FT FOOT/FEET FTG FOOTING GA GAUGE GALV GALVANIZED GC GENERAL CONTRACTOR GEN GENERAL GRADE TOP OF FINISH GRADE GYP GYPSUM HDWR HARDWARE HDWD HARDWOOD HGT HEIGHT HOR HORIZONTAL HR HOUR HDR HEADER HB HOSE BIBB ID INSIDE DIAMETER INS INSULATION INT INTERIOR ID INSIDE DIAMETER JT JOINT KSI KIPS PER SQUARE INCH LT LIGHT LV LOUVER LT LAUNDRY TUB MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MIN MINIMUM MET METAL (N.T.S.) NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OPNG OPENING OPT OPTIONAL OSB ORIENTED STRAND BOARD OZ OUNCE 1/R ONE ROD 1/S ONE SHELF PRCST PRECAST PREFAB PREFABRICATED PB PARTICLE BOARD PCBP PORTLAND CEMENT BASED PLASTER PL PLATE PNL PANEL PLY PLYWOOD PR PAIR PROJ PROJECT/PROJECTED PSI POUNDS PER SQ. IN. PSF POUNDS PER SQ. FT. PT PRESSURE TREATED QUAD QUADRUPLE REF REFERENCE REINF REINFORCE-ING-ED REQD REQUIRED RM ROOM RNG RANGE RGH OPNG ROUGH OPENING R RISER RND ROUND R.&S. ROD AND SHELF SCH SCHEDULE SHLV SHELF SHTHG SHEATHING SIM SIMILAR SP SOUTHERN PINE SPF SPRUCE-PINE-FIR SR SHOWER ROD SST STAINLESS STEEL STL STEEL STR STRUCTURAL SUSP SUSPENDED/SUSPENSION SGD SLIDING GLASS DOOR SQ SQUARE TB TOWEL BAR TP TOILET PAPER DISPENSER T & G TONGUE AND GROOVE TYP TYPICAL T OR TR TREAD TPL TRIPLE UNO UNLESS NOTED OTHERWISE VERT VERTICAL VP VENT PIPE W WASHER W/ WITH WC WATER CLOSET WD WOOD WWF WELDED WIRE FABRIC W/O WITHOUT WDW WINDOW 1.5 1. CONTRACTOR AND SUB-CONTRACTORS SHALL STRICTLY OBSERVE ALL APPLICABLE CODES DURING THE COURSE OF CONSTRUCTION INCLUDING ALL STATE, CITY, AND COUNTY BUILDING, ZONING, ELECTRICAL, MECHANICAL, PLUMBING AND FIRE CODES. CONTRACTOR SHALL VERIFY ALL CODE REQUIREMENTS PRIOR TO COMMENCEMENT OF WORK. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL NOTIFY THE DESIGN PROFESSIONAL OF RECORD OF ANY DISCREPANCY PRIOR TO CONSTRUCTION. 3. THE ARCHITECT / ENGINEER SHALL NOT BE RESPONSIBLE FOR SAFETY PROCEDURES, THE MEANS AND METHODS OF CONSTRUCTION, TECHNOLOGIES, OR THE FAILURE OF THE CONTRACTOR TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS OR THE RELATED CODES. 4. CONTRACTOR SHALL FULLY REVIEW ALL ITEMS CONTAINED IN THE DRAWING AND SHALL COORDINATE ALL DIMENSIONS, LOCATE DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, BOLT SETTINGS, SLEEVES, ETC. 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE ERECTION PROCEDURE AND SEQUENCING. 6. UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL CONSTRUCTION SHALL COMPLY WITH THE MINIMUM REQUIREMENTS OF THE APPLICABLE FLORIDA BUILDING CODE AND LOCAL ORDINANCES. 7. ALL CODES, TRADE STANDARDS, AND MANUFACTURER'S INSTRUCTIONS NOTED IN THE DOCUMENTS SHALL BE THE LATEST ADOPTED EDITION. 8. NOTES, DETAILS, AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT. DETAILS NOTED 'TYPICAL' IMPLY ALL CONDITIONS TREATED SIMILARLY. CONTRACTOR SHALL MAKE MODIFICATIONS TO ACCOMMODATE MINOR VARIATIONS. 9. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES OR MODIFICATIONS WITHOUT EXPRESSED WRITTEN APPROVAL OF THE DESIGN PROFESSIONAL OF RECORD. 2. 2.1 1. ALL WORK SHALL CONFORM TO THE FINAL GEOTECHNICAL REPORT AND FINAL GRADING PLAN ACCEPTED BY THE AUTHORITY HAVING JURISDICTION. 2. ALL SITE PREPARATORY WORK REQUIRED BY THE GEOTECHNICAL REPORT SHALL BE PRESUMED TO BE COMPLETED PRIOR TO COMMENCEMENT OF WORK. 3. FOUNDATION IS DESIGNED BASED ON AN ALLOWABLE SOIL BEARING PRESSURE OF 2000PSF, GENERAL CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO PLACEMENT OF FOUNDATION. 4. CONTRACTOR SHALL VERIFY COMPACTION REQUIREMENTS PRIOR TO THE EXECUTION OF WORK. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN PROFESSIONAL PRIOR TO COMMENCEMENT OF WORK, 5. FOOTINGS SHALL BE PLACED ON UNDISTURBED SOIL OR COMPACTED ENGINEERED FILL FREE OF ORGANIC MATTER AND COMPACTED TO 95% OF THE MODIFIED PROCTOR, UNLESS OTHERWISE STATED IN THE GEOTECHNICAL REPORT. 6. BOTTOM OF FOOTINGS SHALL BE 12 INCHES MINIMUM BELOW FINISHED GRADE, OR AS REQUIRED BY LOCAL REQUIREMENTS. 7. NO WOOD, VEGETATION, STUMPS, CARDBOARD, CELLULOSE CONTAINING MATERIALS, OR TRASH SHALL BE BURIED WITHIN 15'-0" OF ANY BUILDING OR PROPOSED BUILDING 8. WATER MANAGEMENT AT THE PERIMETER SHALL BE MAINTAINED AND SHALL INCLUDE; A. CONDENSATE DRAINS AND ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST 1'-0" FROM BUILDING SIDEWALLS. B. IRRIGATION / SPRINKLER SYSTEMS, INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 1'-0" OF BUILDING SIDEWALLS. 2.2 1. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD OR OTHER APPROVED METHODS. 2. BOXED AREAS IN CONCRETE FLOORS FOR INSTALLATION OF TRAPS, ETC.,SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS SHALL BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER INITIAL TREATMENT. 3. SOIL SHALL BE PROTECTED WITH MINIMUM 6 MIL VAPOR RETARDER FOLLOWING TREATMENT. 4. AFTER COMPLETION OF WORK, ALL LOOSE WOOD AND ORGANIC MATERIAL SHALL BE REMOVED FROM WITHIN 1'-0" OF THE BUILDING PERIMETER. 5. AT COMPLETION OF TERMITE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE SHALL STATE: A. "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." 3.1 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE ACI 318. 2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28-DAYS OF 3000 PSI, COMPLYING WITH ASTM C-94 UNLESS NOTED OTHERWISE IN DRAWINGS. 3. A MIX DESIGN SHALL BE SUBSTITUTED TO THE DESIGN PROFESSIONAL OF RECORD FOR ALL CONCRETE USED PRIOR TO PLACEMENT OF ANY CONCRETE. 4, MATERIALS FOR CONCRETE SHALL CONFORM TO THE FOLLOWING: A. PORTLAND CEMENT - ASTM C 150 B. AGGREGATES: I. COURSE AGGREGATE - ASTM C33 II. LIGHTWEIGHT AGGREGATE - ASTM C33 III. FINE AGGREGATE - ASTM C33 5. WATER SHALL BE CLEAN, POTABLE AND FREE OF CONTAMINANTS 6. ADMIXTURES SHALL BE AS NOTED IN THE APPROVED MIX DESIGN. 3.2 1. ALL TESTING OF CONCRETE SHALL BE DONE BY AN INDEPENDENT TESTING LABORATORY IN ACCORDANCE WITH ASTM PROTOCOL. TEST REPORTS SHALL BE SUBMITTED TO THE DESIGN PROFESSIONAL OF RECORD WITHINSEVEN-DAYS OF LABORATORY TESTING. 2. THREE (3) TEST CYLINDERS SHALL BE MADE FOR EACH DAY'S POUR, FOR APPROXIMATELY 50 YARDS OF CONCRETE PLACED. 3. SLUMP TEST SHALL BE MADE ON EACH BATCH TESTED IN ACCORDANCE WITH ASTM C143. 4. ONE CYLINDER SHALL BE BROKEN AT 7-DAYS AND ONE AT 28-DAYS. IF NO FURTHER TEST IS NEEDED, THE RESERVE CYLINDER MAY BE DISCARDED AFTER SIXTY DAYS. 3.3 1. GROUT SHALL BE IN ACCORDANCE WITH ASTM C476 HAVING A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI. 2. FILL CMU CELLS SOLID WITH GROUT AT ALL UNITS RECEIVING REINFORCEMENT AND AS INDICATED ON DRAWINGS. 3. FILL SOLID FIRST COURSE BELOW CHANGE IN WALL THICKNESS AND AT TOP OF ALL CMU WALLS. 4. GROUT SHALL BE PLACED FLUSH TO THE TOP OF ALL LINTELS AND BOND BEAMS. 5. CONSOLIDATE AND RECONSOLIDATE GROUT WITH VIBRATOR FOR FULL HEIGHT OF FILLED CELLS, BOND BEAMS, AND LINTELS. 6 2. REINFORCING SHALL BE FREE OF RUST, SCALE, OR OTHER BOND-REDUCING COATINGS. 3. REINFORCING SHALL BE PLACED IN CONCRETE TO PROVIDE MINIMUM COVERAGE IN ACCORDANCE WITH ACI 318, OR AS INDICATE HEREIN: A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH - 3-INCHES. B. CONCRETE EXPOSED TO EARTH OR WEATHER - 1 1/2-INCHES. C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND - 3/4-INCHES 4. ACCURATELY PLACE AND SUPPORT REINFORCING WITH CHAIRS, BAR SUPPORTS, SPACERS, OR HANGERS AS RECOMMENDED BY ACI DETAILING MANUAL. 5. PLACE ONE (1) ACI STANDARD LAP SPLICE BAR, OF THE SAME SIZE AS FOUNDATION REINFORCING, LOCATED AT THE OUTSIDE BAR OF FOUNDATION CORNERS. 6. WELDED WIRE MESH, IF USED, SHALL BE IN ACCORDANCE WITH ASTM A82 AND SHALL BE 6x6xW1.4xW1.4, UNLESS NOTED OTHERWISE ON DRAWINGS. A. INSTALL WELDED WIRE MESH IN THE MIDDLE OF THE SLAB AND SUPPORT WITH APPROVED MATERIALS OR SUPPORTS AT SPACING NOT TO EXCEED3 FEET ON CENTER OR IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS. B. LAP ALL JOINTS IN WELDED WIRE MESH 8" 7. FIBER MESH, IF USED, SHALL BE IN LIEU OF WELDED WIRE MESH AND AS SPECIFIED IN THE CONCRETE DESIGN MIX. 3.5 1. ALL CONCRETE PLACED UNDER ROOF PROTECTION SHALL BE PLACED OVER MIL POLYETHYLENE VAPOR BARRIER, LAPPED 6" MINIMUM WITH ALL SEAMS TAPED, UNLESS NOTED OTHERWISE 2. PLACE ALL EMBEDDED ITEMS (ANCHOR BOLTS, DOWELS, ETC.) IMMEDIATELY PRIOR TO PLACEMENT OF CONCRETE OR DURING CONCRETING OPERATIONS. 3. PROTECT ALL CONCRETE FROM DAMAGE AFTER PLACEMENT. 4. CONCRETE SHALL BE PLACED WITHIN 90 MINUTES OF BATCHING. 5. CONCRETE SHALL BE PLACED WITHIN THE SLUMP LIMITS SPECIFIED IN THE DESIGN MIX. 6. WATER ADDED AT THE SITE SHALL BE KEPT TO A MINIMUM AND WITHIN THE SPECIFIED SLUMP. RUN MIXER FOR 30 REVOLUTIONS AT EIGHT TO TWELVE RPM FOLLOWING THE ADDITION OF WATER AT THE SITE. 7. CONCRETE SHALL NOT BE PLACED DURING RAIN. FOLLOWING PLACEMENT OF CONCRETE, PROTECT FROM RAIN PRIOR TO INITIAL SET. 8. PLACEMENT SHALL BE CONTINUOUS UNTIL ALL WORK IS COMPLETED. 9. DO NOT USE CONTAMINATED, DETERIORATED, OR RE-TEMPERED CONCRETE. 10. THOROUGHLY WORK CONCRETE AROUND REINFORCING BARS. 11. PLACE CONCRETE TO GRADES AND ELEVATIONS REQUIRED FOR PROJECT 12. REMOVE ALL GRADE STAKES AFTER PLACEMENT OF CONCRETE. 13. CONTRACTOR SHALL INSTALL SAW-CUT CONTROL JOINTS IN CONCRETE SLABS PER ACI 224.3R AS FOLLOWS: A. PROVIDE SAW-CUT FOLLOWING FINISHING AS SOON AS CUT EDGES WILL NOT RAVEL B. SAW CUTS SHALL BE A MINIMUM OF 1/8” WIDE C. CUTS SHALL BE 1/4 OF SLAB DEPTH NO LESS THAN 1", WHICHEVER IS GREATER. FOR STEEL-FIBER-REINFORCED SLABS 1/3 THE SLAB DEPTH. D. SAW CUTS SHALL NOT EXCEED 12 FEET IN ANY DIRECTION E. LOCATE SAW CUT JOINTS: 1. MAKE PANELS AS SQUARE AS POSSIBLE 2. JOINT LOCATIONS SHALL NOT EXCEED 1.5 TO 1 RATIO 3. PANELS SHALL NOT HAVE “T” OR “L” SHAPE 4. NO RE-ENTRANT CORNERS SHALL BE ALLOWED 14. PROVIDE SURFACE FINISH REQUIRED FOR INTENDED FINAL APPLICATION. 15. SILL PLATE ANCHORS SHALL BE AS SPECIFIED IN SECTION 6. 16. CONSOLIDATE CONCRETE DURING PLACEMENT OPERATIONS. CURRENT RELEASE v3.3 020918 C 124 MPH - NOMINAL DESIGN WIND SPEED 160 MPH - ULTIMATE DESIGN WIND SPEED U YES OPEN +/- 0.00 4. 1. STRUCTURAL WORK SHALL CONFORM TO THE " SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INC. LATEST EDITION. 2. STRUCTURAL STEEL SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS: WIDE FLANGE SHAPES ASTM A992 (Fy=50KSI) MISC SHAPES, PLATES AND BARS ASTM A36 (Fy=36KSI) HOLLOW STRUCTURAL SECTIONS (HSS) SQUARE ASTM A500, GRADE B (Fy=46KSI) HIGH STRENGTH BOLTS SAE GRADE 5 ANCHOR BOLTS ASTM F1554, GRADE 36 WELDING ELECTRODES E70 (LOW HYDROGEN) DEFORMED BAR ANCHORS ASTM A496 STEEL WIRE DEFORMED 3. HIGH STRENGTH BOLTS SHALL BE TIGHTENED TO THE "SNUG TIGHT" CONDITION, UNLESS OTHERWISE INDICATED. 4. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING CODE - STEEL". 3.4 1. REINFORCING SHALL HAVE GRADE IDENTIFICATION MARKS AND SHALL CONFORM TO ASTM A615 GRADE 40 OR 60. 13" 11" 42" BAR MINIMUM MINIMUM MINIMUM ACI HOOKBEND DIA.LAPSIZE 10" 10" 5-1/4" 4-1/2" 3-3/4" 3" 36" 30" 24" # 7 # 6 # 5 # 4 60 KSI REINFORCING STEEL MINIMUM REQUIREMENTS 1. 1.1 1. TO THE BEST OF THE DESIGN PROFESSIONALS KNOWLEDGE, THESE DOCUMENTS HAVE BEEN PREPARED WITH AND ARE IN COMPLIANCE WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE CHAPTERS 553 AND 633 OF THE FLORIDA STATUES. THESE DOCUMENTS MEET OR EXCEED THE REQUIREMENTS OF: FLORIDA BUILDING CODE, BUILDING, 7TH EDITION (2020). 1.2 1. REFERENCE STANDARDS A. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE (ACI)318 AND 332. B. ALL MASONRY WORK SHALL BE IN ACCORDANCE WITH ACI 530/530.1; AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE); TMS 402. C. REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI 318 D. ALL STEEL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF AISC MANUAL 1.4 1. BUILDING RISK CATEGORY: II 2. BUILDING CONSTRUCTION TYPE: TYPE V-B 3. OCCUPANCY CLASSIFICATION: 4. WIND SPEED PER ASCE 7-16: 5. WIND SPEED PER ASCE 7-16: 6. EXPOSURE: 7. ENCLOSURE CLASSIFICATION: 8. INTERNAL PRESSURE COEFFICIENT: 9. WIND-BORNE DEBRIS ZONE: 10. REFER TO DRAWINGS FOR NUMBER OF STORIES AND STRUCTURE HEIGHT REVISION TABLE REV DESCRIPTIONREV # INFO WAS ADDED IN GENERAL NOTES AND NEW FRAMING SHEETS101/28/2022 1 SHEET LIST TABLE SHEET # SHEET TITLE REV_NO REV_DATE S001 S100 E100 STRUCTURAL GENERAL NOTES CRANE FOUNDATION PLAN & ELEVATIONS ELECTRICAL ELEVATION 1 01/28/2022 1 0 S200 CRANE FRAMING PLAN & ELEVATION 1 SD303 CRANE FRAMING DETAILS 1 00/00/0000 REV DATE 01/28/2022 01/28/2022 01/28/2022 01/28/221 License No. 26002939 License No. 30900Service Beyond Designwww.forefrontae.comREVISION DATE: JOB #: ANY DISCREPANCY OR ERROR IN DIMENSIONS OR NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN PROFESSIONAL FOR CLARIFICATION PRIOR TO COMMENCEMENT OF CONSTRUCTION.SEALC FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED. 05/21/2021 20-12342 J:\ChemTech Holding\Jobs\Fort Pierce Building\20-12342-04\Dwgs\Sheets\Structural\S001 ; Plot Date: Monday, January 31, 2022 ,12:48:08 PM ; Plotted By: michelleg 1 29'-2"27'-11" 6'-10"14'-3"6'-10" 14"16"24"24" BASE PLATE F2.0 F2.0 STEEL CRANE STRUCTURE (BY OWNER) F2.0 - DENOTES 2'-0" X 2'-0" X 1'-0" THICK FOOTING REINFORCED WITH (3) #5 EACH WAY TOP AND BOTTOM F4.0 - DENOTES 4'-0" X 4'-0" X 1'-6" THICK FOOTING REINFORCED WITH (5) #5 EACH WAY TOP AND BOTTOM REFER TO SITE PLAN FOR LOCATION A S100 F4.0 F4.0 F4.0 F4.0 S100 A S200 C S100 B27'-11" COLUMN CENTER FOOTING PER PLAN B S10014'-0"CLEARANCEW SD303 W 10x22 W 16x67 BRIDGE BEAM (BEYOND)W 10x33W 10x33HSS4x4x3/8 29'-2" COLUMN CENTER FOOTING PER PLAN B S100 X SD303 Z SD303 Y SD303 W 14x30 W 10x33W 10x33HSS4x4x3/8 3/4" DIA HEAVY HEX BOLT F1554, GRADE 36 (GALV) WITH 9" EMBEDMENT 18"18"24"X24" PIER GRADE STEEL COLUMN PER PLAN 3/4" GROUT #3 TIES AT 6" O.C. (8) #6 VERTICAL 14"16"24"24" 3/4" DIA HEAVY HEX BOLT F1554, GRADE 36 (GALV) WITH 9" EMBEDMENT 4"4"5"5"1-1/2"13"1-1/2"11"1-1/2"1-1/2" STEEL COLUMN PER PLAN CONCRETE PIER 01/28/220 License No. 26002939 License No. 30900Service Beyond Designwww.forefrontae.comREVISION DATE: JOB #: ANY DISCREPANCY OR ERROR IN DIMENSIONS OR NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN PROFESSIONAL FOR CLARIFICATION PRIOR TO COMMENCEMENT OF CONSTRUCTION.SEALC FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED. 05/21/2021 20-12342 J:\ChemTech Holding\Jobs\Fort Pierce Building\20-12342-04\Dwgs\Sheets\Structural\S401 ; Plot Date: Tuesday, February 01, 2022 ,12:20:41 PM; Plotted By: courtneyl SCALE: FOUNDATION PLAN - CRANE 1/4"=1'-0" SCALE: ELEVATION - B 1/4"=1'-0" SCALE: ELEVATION - A 1/4"=1'-0"SCALE: DETAIL - A 1"=1'-0" SCALE: DETAIL - B 1"=1'-0" 1 W 10x22 W 10x22 W 14x30W 14x30W 16x67 BRIDGE BEAM D SD303 CRANE INFO: MFG: KONE CAP: 3 TON S100 A S200 C S100 B27'-11" COLUMN CENTER FOOTING PER PLAN B S10014'-0"CLEARANCE9'-0"W 10x33W 10x33W 10x22 W 16x67 BRIDGE BEAM (BEYOND) FOOTING PER PLAN 6'-10" W SD303 H S S 4 x4 x3 /8H SS4x4x3/8 01/28/20221 License No. 26002939 License No. 30900Service Beyond Designwww.forefrontae.comREVISION DATE: JOB #: ANY DISCREPANCY OR ERROR IN DIMENSIONS OR NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN PROFESSIONAL FOR CLARIFICATION PRIOR TO COMMENCEMENT OF CONSTRUCTION.SEALC FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED. 05/21/2021 20-12342 J:\ChemTech Holding\Jobs\Fort Pierce Building\20-12342-04\Dwgs\Sheets\Structural\S200 CRANE FRAMING ; Plot Date: Tuesday, February 01, 2022 ,12:20:42 PM; Plotted By: courtneyl SCALE: FRAMING PLAN - CRANE 1/4"=1'-0"SCALE: ELEVATION - C 1/4"=1'-0" 1 3/4" DIA ANCHOR ROD AT 12" OC STAGGER EACH SIDE BRIDGE BEAM PER PLAN CONT STEEL RUNWAY RAIL CONT 11" STEEL CHANNEL CONT STEEL BEAM PER PLAN 3/8" CAP PLATE 1/4" STIFF PLATE (4) 3/4" DIA BOLTS COLUMN PER PLAN BEAM PER PLAN STEEL CHANNEL W 10X33 1/4" 3/16" 1/4" STIFF PLATE COLUMN PER PLAN (4) 3/4" DIA BOLT HSS BRACE PER PLAN 3/8" END PLATE BEAM PER PLAN 3/8" END PLATE (4) 3/4" DIA BOLTS HSS BRACE PER PLAN 1/4" STIFF PLATE BEAM PER PLAN (4) 3/4" DIA BOLTS 3/8" CONNECTION PLATE W/(2) 3/4" DIA BOLTS 3/8" CAP PLATE COLUMN PER PLAN SCALE: File Name: DETAIL Y SCALE: File Name: DETAIL X SCALE: File Name: DETAIL Z SCALE: File Name: SECTION D SCALE: File Name: DETAIL W 1'-0"=1'-0" 1'-0"=1'-0"1'-0"=1'-0" 1'-0"=1'-0"1'-0"=1'-0" BEAM PER PLAN 01/28/20221 License No. 26002939 License No. 30900Service Beyond Designwww.forefrontae.comREVISION DATE: JOB #: ANY DISCREPANCY OR ERROR IN DIMENSIONS OR NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN PROFESSIONAL FOR CLARIFICATION PRIOR TO COMMENCEMENT OF CONSTRUCTION.SEALC FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED. 05/21/2021 20-12342 J:\ChemTech Holding\Jobs\Fort Pierce Building\20-12342-04\Dwgs\Sheets\Structural\SD303 CRANE FRAMING DETAILS ; Plot Date: Monday, January 31, 2022 ,12:48:11 PM; Plotted By: michelleg 1