Loading...
HomeMy WebLinkAboutFoundation Plan & Details5TRUGTURAL NOTES: • 501L BEARING CAPACITY MIN. 2500 PSF • ALL 5TRUGTURAL CONCRETE SHALL DEVELOP A MIN. COMPRESSIVE STRENGTH OF 3000 P51 AT 25 DAYS. • ALL REINFORCING STEEL SHALL BE GRADE 60 MEETING A5TM 5PE05 A-615 • MIN. GONG. PROTECTION FOR RE-5AR5: FT65:3" BEAMS:1V SLABS: 1" • LAP REINFORGIN6 BARS 30 INCHES MINIMUM EXPOSURE "G" - 1-70 MPH 3 SEC GUSj PROVIDE 3OX30 6 ALUM A0GES5-- NOTE: DOOR. THE FOUNDATION/PIER SYSTEM 15 DE516NED TO RF-515T FLOOD ELEMENTS OF FLOTATION, GOLLAP5E AND LATERAL MOVEMENT PER FEMA CRITERIA FOR EXP05URE "C" LOCATIONS. ACGE55 DOORS TO BE BUILT ON A 1" X 2" OPEN BACK FR. SECURED WITH #10 X 2" SHEET METAL 5GREW5, WITH A HALF-Z WRAP (#5 X 3/4" TEK5 ON THE FACE); DOOR 5LAB 15 50REEN DOOR MAINFRAME #10 X 1" SHEET METAL 5GREW5 INTO AN INTERNAL ALUMINUM CORNER WITA .024 STUCCO COIL FOR THE FACE OF THE DOOR. ATTACH,U TO FRAME WITH 2 STANDARD SCREEN DOOR OFF5ET HINC STANDARD SCREEN DOOR LATCH FOR HARDWARE. . CONCRETE THICKENED EDGE: S"D X 5"W YV/ (1) #5 RB CONT CONCRETE EXTENSION G REQUIRED ALONG ENTIRE 6' LENGTH OF CARPORT (FOR FUTURE IMPROVEMENT) SECTION E3-5 SCALE: 3/4" = 1'-0" UNIT TO BE TIED DOWN HYDRO VENT (5) THI5 SIDE PROVIDE 5OX50 ALUM ACCESS - -T- .- - t — I— —1cD-- -�— =T =tfII tv t— F— —Ic-r L —1— —N II— -A SEE STAIR DETA $ DECK DETAILS HYDRO ENT . THIS SIDE 36" 16H ;l_A-VIN RAIL tt5 PROVIDE BOX30 I�� ALUM ACCESS-�"'T I R1 3' HYDRO VENT (5) THI5 SIDE PROVID /8" TOU6HROCK FIRE GUA GYP. BOARD (BOTH SIDES MALL) (U305) 1 HOUR AAtL.L ON ZERO LOT LINEbVE TIE-DO^N /F I ER REQU I REM EN TS SCALE: 1/4" = I'-O" PROVIDE (2) #9 X 2-' 2X 5YP DECK 5GREW5 TOE NAILED V AT EACH VERTICAL MEMBER OF KNEE PNALL TIE DOWN STRAP PER SPECIFICATIONS YlIALL COMPLIES WITH UNIT MANUFAGTURER'5 PERIMETER YHALL BLOCKING REQUIREMENT -BEAM HYDRO VENT SEE PLAN b" X all X 16" 2X4 P.T. 5YP KNEE Y'1ALL W/ STUDS 0 16" OG GB5 BLOCK W/Yd'x3" TAP -DONS 24' OC-" PIERS ' (BOTTOM PLATE) W/ 1 , GDX PLYWOOD COVERED W/ /8" CEMENT BOARD YV/ IN TYVEX W/ HARDI LAP SIDING 4" SLAB YV/ RB xx I- 4 H w SEE TIE -DOWN/ m > PIER REOUIREMENT5 n L MI052 ANCHOR %"x-I" WEDGE ` CONCRETE THICKENED EDGE: 5"D X 5"W A/ (1) #5 RB CONT (SEE DETAIL) ANCHOR (RED HEAD) O�G fu�P \ JP �k Q SECTION A -A PROVIDE MIAMI TECH GUTD BRACC KETS GONDEN51N6 UNIT (5) SELF TAPPING METAL 5GREW5 3/6' X 1 Y4' TAPGON A/C TIE -DOWN DETA CONCRETE FAD I -BEAM PART # 59002 5TRAP/5WIVEL CONNECTOR y FACTORY WELDED BRACKET FRAME ATTACHMENT FOR FACTORY BRACKETS GONGRETE UNIT WT3560 LB5. 55.5 #/ FT (1) Y4' X 2Y4' L6. TAPCON PER BLOCK ' 8 (2) AT CONCRETE: 180 LB5. PIER DETAIL 3-BOLT 50ME HOMES MAY HAVE FACTORY BRACKETS WELDED TO THE I -BEAMS FOR LON61TUOINAL ANCHORS. ATTACH THE 57RAP/51/4IVEL CONNECTOR TO THE FACTORY BRACKETS U51NO A 2" GRADE 5 BOLT & NUT. ANCHORS/TIES MUST BE IN5TAL.LED TO PROVIDE A 450 OR LOWER 5TRAP ANGLE. CONDENSING UNIT SIMP50N M5TG5.2 8X16 BLOCK 4 COUR5E (2) #14 5HEET METAL 51-REW5 TO CONDENSING UNIT. 200 LB. 5HEER WORKING GAPAOTY P05T PIGKE 1X2-3/4" ONE (5) THI5 SIDE 39'-O" 5-4" 5-4" 5-4" 5'-4" 5-4" 5'-4" 1'-4" ❑ ❑ ❑ ❑ ❑ ❑ ❑ I PROVIDE Y2" MACHINE BOLT THRU I -BEAM I W/ (2) TIE DOWN STRAPS AT BOLT (2) MI052 ANCHORS AT CONCRETE AS 5HOY4N I (SEE TIE DOWN ENGINEERING C:V= FOR D_E NFORMATI - - - - - - - ---- IT❑ -�--- n - - o - - o - - a -�- ❑ th 4" 3'-9" 1 4,_�,4'_S""4'_5z'.4l-��. 4'-51„ 4,_„ 5,_3„ Til E�-------------------�----�-- g�� I IDE Y,' MACHINE BOLT THRU I -BEAM 5"x16" CONCRETE FOOTING I YV/ (2) TIE DOWN 5TRAP5 AT BOLT Yll/ (2) #5 RB CONTINUOUS (2) MIG52 ANCHORS AT CONCRETE I ? I A5 SHOWN (SEE TIE DOWN ENGINEERING FOR DETAILED INFORMATION) 60 to a, I - — - — - — - — - 'ACT WINDQW - — - — - ]'_4" 1'_4" 6uM'w10d 5EE SHEET 5-2 FOR aUnPOoo^j„3 5T G ROOM Ffi�MING R. HYDRO VENTS IN KNEE WALL TO BE SCALE: 1/4° r—O° MODEL F5 1605 (80.7 50. IN. NET) PER 322.2.2. (1) 50. IN. FOR EACH 5Q. FT. OF ALL MATE91A1L BELOW FLOOD MUST BE CONSTRUCTED ENCLO5E1;) AREA. EACH VENT COVERS ao 5a. FT, WITH FLOOD RE515TANT MATERIAL, IN ACCORDANCE WITH PER PRODUCT APPROVAL. SECTION R322 OF THE 2020-1 (7TH EDITION) RE51DENTIAL BUILDING CODE. 535 5Q. FT. / 80 = 10 VENTS 4X4 5YP POST PER 408.2. EXCEPTION (1) SQ. ".STAIR DETAIL PER 1500 5Q. FT. OF FLOOR ARE I I 2X6 5YP DECK WITH VAPOR BARRIER. JOISTS ®16" OG (1) 50. FT. = 144 5Q. IN. I I I I m NET VENT AREA 15 80 SQ. � GOMP051TE DECKING ATTACHED W/ (2) #10 2X6 5YP STRINGER 144 / 80 = 2 VEN 75 GALV DECK 50REW5 AT EACH BEARING POINT 3'-6" 2-#10 X 1" NON-GORR051VE 5.M.5. @ EACH PICKET CONNECTION. TOP PLATE TO P05T 8 POST TO CHANNEL W/ #10 X 1-)/y 5.M.5. NOTES: HANID RAIL DETAIL 2-6ALV. BOLTS 5e'-11 kX/ HEX. 5Q. NECK W/ NUTS TEN51ON BOLT LABELED (A) FOR FRAME ATTACHMENT ONLY. 5/e'x1" WEDGE ANCHOR (RED HEAD) TEN51ON BOLT LABELE VERTICAL TENSION. #10 5.5.5. MIN. 2" EMBEDMENT. 4-REQ'D. M IG52 ANCHOR BY: TIE DOWN ENGINEERING MAX UPLIFT PER COMPOSITE DEVICE 15 4,750 LB5 DEGKIN6 2X5 5YP STRINGER 2X COMPOSITE DECKING ATTACHED W/ (2) #10 DECK FRAMINO DETAIL AT EACH BEAR N6 POENT SCALE: 1/4" 1'-0" 2X5 5YP DECK J015T SUPPORT W/ (2) %" GALV LAG 5GREW5 VINYL 2X2 RAIL P05T AT GARAGE DECK OR ATTACHED TO VINYL (2) Y2" GALV MACHINE CASTERS BOLTS AT EXTERIOR DECKS Y3" 5.5.5. MIN. 1" EMBEDMENT. 4-REQ'D. 2X6 5YP STRINGER DECIG CONNECTION DETAIL TYPICAL ELEVATION5 FOR DEGK5 SCALE: 1/2" I'-O" N.T.S. (FOR VISUAL PURPOSES ONLY) 51MP50N FACE MOUNT HANGER LU26 - 2X6 5YP DECK JOISTS 0 16" OG LENGTH VARIES 51MF50N STRAP 2X6 5Y7 5TRINOER SIMP50N LU25 AT STAIR 5TRINC,ER5 TO 2XE5 DECK J015T SUPPORTS OR (2) 3/s" 6ALV LAC, 5GREW5 AT 5TRIN6ER TO P05T 2X COMPOSITE DEGKIN6 ATTACHED YV (2) #10 6ALV DECK 5GREW5 AT EACH BEARING POINT 4X4 PT P05T W/ SIMP50N AB44 '5 2X12 5YP 5TRIN6ER 2X12 SYP STEP 1X5 5YP W/ DECK 50REW5 3/6 X 3" 6ALV. HEX 5GREW5 4-REQ'D. :R N6LE "APGONS TREAD + 1" NOSE STAIR DETAIL NOTE: HANDRAIL BRACKETS OR BALUSTERS N.T.S. SHALL NOT BE CONSIDERED TO BE OBSTRUCTIONS TO C,RA5PABILITY. BOTTOM OF HANDRAIL SHALL CONTINUE TO SLOPE FOR A DISTANCE OF THE DEPTH OF ONE TREAD FROM BOTTOM RISER. RAILING BASE CONCRETE J Y2' WEDGE ANCHOR A/ 5" EMBEDMENT MIN m i #8 C,ALV 5GREW5 (2) EACH 51DE 4X4 5YP POST ATTACHED TO GONG W/ SIMPSON AB44 P05T BASE HANDRAIL HAS CIRCULAR GR055-5ECTION W/ 1-Y4" TO 2" DIMENSION. NOTE: GUARDRAIL SHALL COMPLY NV FBG 2020 (TTH EDITION) THIS SETUP HAS BEEN DESIGNED FOR A FLOOD ZONE INSTALLATION PE51ON GORE FBG — 2020 (`iTH EDITION) L Architecture AA20005774 W SW nALKLL AVrnUF POPT SAID LUCK LL. 34V 772-800-5700 www.1b1dr(hite(ture.(om pF FLU Cc y ti �w F � clsrFRED N C �L 0 U-) 0 OG Q o 0 "-' J Q F— Q 0 a DO(UnETIT DATE:: 11.9.2021 Uvislor is fl% TOUR RRO R[55 MAIT DAT[ 1 6UIIDIfib DTaTAWT (OMMTS 09212020 2 PO MAWS V222020 CCU �c LUC. v / o Q WE COPY _ (L/ LULU m ED L z O 1 u- � L.Un NN� VI M kD SHEET TITLE: FOUNDATION PLAN & DETAILS SHEET MUAWD TYFI GAL WALL SECTION SCALE: -114- = I'-0" HATGHIN6 DENOTES A55EMBLY 5IMF50N H5 5TRAP5 AT EACH STUD TO SEAM ATTACH TO STUDS AND BEAM iON 5TRON6 DRIVE FRAMING 5GREW TO WOOD SON 5TRON6 DRIVE XM 50REW TO ALUM. X9 ALUMINUM BEAM IN6 TO BOTTOM OF ,LUMINUM BEAM SOARD 51DIN6 OVER "HARDIE WRAP OR EQUIVALENT" BOARD ON (WOOD ON 161,00 b DETAILS TH15 SHEET FOR FA5TENIN6 INFORMATION >5T STUD TO EXI5TIN6 4X4 P05T W/ rAL 5GRE N5 6" FROM ENDS 8 12' OG 5PH4 AT EACH STUD 5E PLATE =-GON5 @ 24" Or - EXTENSION ALONG ENTIRE CARPORT FOOTING TINUOU5 Q Ul FLOOR FLAN_ SCALE: 1/4" = I'-0" 2xh STP WOOD FASTEN 5TUD5 TO DBL TOP PLATE W/ SIMPSON 5PH6 FILL ALL HOLES W/ 10d NAILS P (SEE FLOOR PLAN) LB1 Architecture AA26003774 (MIN 2X10 HEADERS YV Y,' T SW HAI K�I /�Il�nl I� PLYWOOD FLITGHIN6 FOR JI VVVV 1 �HLI\ LL HV U FLUSH MOUNTING OF DRYWALL POPT SQII IT OGI FL 3495.E F DOUBLE TOP PLATE i K 7.JN2_I8I OO\-J700 f 7 CONTINUE STRAPPING www.lbjdr(hk(ture.(om Fa— TOP PLATE ACROSS HEADER 9 16" O.G. FA5TEN JAGK5 TO OF FL WOOD HEADER W/ `�� S A4 51MP50N ST15 Cl) c d FILL ALL HOLES W/ 16d NAILS �A 14248 PROVIDE DOUBLE STUDS FIST �l` UNDER ALL BEARING WALL ERED N HEADER OMNIN65 U.N.O. PROVIDE SINGLE STUD UNDER 5-0" OPENING FASTEN STUDS TO BASE PLATE W/ 51MP50N 5PH6 FILL ALL HOLES YV 10d NAILS �L O 4— WOOD HEADER DETAIL HardiePlank® Lap Siding WATER RESISTIVE FARRIER HardleWrap TM or Equivalent MIR 1 1/4" OVERLAP REVIEWED FOR CODE COMPLIANCE ST LUCIE COUNTY E CC 4d SIDING NAIL b" O.C. PER FL`131% FILE copy 1/2" EXTERIOR SHEATH[Ws SIDING ATTACHMENT DETAIL EXT'R DOOR DETAILS ALL MATERIAL BELOW FLOOD MUST BE CONSTRUCTED DOOR5 BY DOOR MANUF. ATTACHED TO 5TUD5 WITH FLOOD RESISTANT MATERIAL, IN ACCORDANCE WITH PER PRODUCT APPROVAL 5EGTION R322 OF THE 2020 (ITH EDITION) RESIDENTIAL BUILDING ALL WALL 5HEATHIN6 TO BE NAILED AS 4" OG VV/ 10d NAILS AT ALL EDGE5 6" OG W/ 10d NAILS AT ALL INTERIOR PANEL BEARING POINTS DESIGN CRITERIA 1) PER FBG - TfH EDITION 2) USE & OGGUPANGY R-3 3) GON5TRUGTION TYPE V_ 4) RI5K GATEGORY 11 ULTIMATE DESIGN WIND SIMEP 5) EXPOSURE G_ SURFACE ROUGHNES5 G 6) GOMPONENT5 $ GLAI7VING (WOR5E WALL5 +34.4 -42.I ON I O T- r o J —J �1 O lLJ J Q F— LLJ U.-J r Q Q r D0(U/1EI7T DATE:: 08.15.2020: REVISIOfIS: N% TOUR PROW55 SUMIT WC LLI J W O T � >- m U.l 0 Q L � z O LL F- V/ m � S11EET TITLE: DETAILS SHEET 1`11-1/16ER: S-2