Loading...
HomeMy WebLinkAboutAPPROVED 5105 Myrtle Dr PSL Prop Duct DrawingJob #: 1627 Performed by Chris Bateman for: Tamez Residence 5105 Myrtle Dr Fort Pierce, FL 34982 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 113 Page 1 Right-Suite® Universal 2021 21.0.10 RSU29066 2021-Dec-16 13:49:14 ...HVAC\5105 Myrtle Dr PSL Prop.rup N Level 1 Garage WIC Laundry AHU Master Bed Master Bath Living Room Kitchen Nook Family Room Bed 3 Bed 2 Bath HallFoyer 10 x 10 160 cfm 12 x 8 194 cfm 12 x 8 134 cfm 8 x 8 79 cfm 8 x 8 79 cfm 10 x 6 58 cfm 10 x 6 67 cfm 10 x 6 60 cfm F F 12 x 12 134 cfm 12 x 12 194 cfm H/W 10 x 10 143 cfm 10 x 10 143 cfm 30 x 18 956 cfm 12 x 12 198 cfm 12 x 12 12 x 8 250 cfm 4 " 7 " 5 " 5 " 5 " 12 " 14 " 9 "5 " 6 " 5 " 7 " 12 " 7 " 7 " 7 " 7 " 8 " 16 "7 " 8 " DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE 50 CFM 4" Duct 4" Exhaust Vent 100 CFM 6" Duct 6" Exhaust Vent 12 " 8 x 4 41 cfm 4 " 10 x 10 136 cfm 10 x 10 136 cfm