HomeMy WebLinkAboutAPPROVED REVISION, PV Plans StampedREV #2 JOHN TRUETT 5612 HICKORY DR, FORT PIERCE, FL 34982 All corresponding changes are notated on the plans by revision clouds. Construction Engineering Freedom Forever engineering@freedomforever.com Revision Details: Attn. ST. LUCIE COUNTY:3/7/2022 The changes outlined in Revision Details have been applied to the plans corresponding to the following customer: Plans were revised with (36) REC: REC305TP2M panels. Layout was adjusted accordingly and matches the as built layout performed at install. Thank you for your time in reviewing these plans. Please reach out if you have any additional questions or concerns. Freedom Forever 3590 NW 54th St #3, Fort Lauderdale, FL 33309, USA PV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-THIS PROJECT COMPLIES WITH THE FOLLOWING:2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY2020 7TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)2017 NATIONAL ELECTRIC CODE (NEC)AS ADOPTED BY ST. LUCIE COUNTYSITE LOCATIONCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BSTRUCTURAL CALCULATIONSPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2017 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.SITE LOCATIONGREG ALBRIGHT2 MSPINVJBUMACSITE PLANSCALE: 3/64" = 1'-0"1PV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-ROOF AREA: 2607.58 SQ FTSITE PLANLEGEND:OBSTRUCTIONPIPE VENTMODULESCONDUITSETBACKMBE AC JBACDISCONNECTMAINBREAKERENCLOSUREJUNCTIONBOXINVINVERTERUMUTILITYMETERGREG ALBRIGHTDRIVEWAYHICKORY DR157'-11"141'-11"141'-11"157'-11"54'-5"14'-7"47'-1"67'-9"PV SYSTEM10.980 kW-DC10.000 kW-ACROOF LINEPROPERTY LINE(N) MAIN SERVICE PANEL(N) 36 REC SOLAR: REC305TP2M(N) AC DISCONNECT EATONDG222NRB (OR EQUIVALENT)(E) UTILITY METER(N) JUNCTION BOXBACKYARDPERIMETERFENCE(N) SOLAREDGE SE10000H-USRGM [SI1]INVERTER WITH RAPID SHUTDOWN22 MSPINVJBUMACPV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-ROOF PLANSCALE: 1/8" = 1'-0"1NOTES:1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3. JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA: 2607.58 SQ FTROOF PLAN WITH MODULES LAYOUTGREG ALBRIGHTLEGEND:OBSTRUCTIONPIPE VENTMODULESCONDUITSETBACKMBE AC JBACDISCONNECTMAINBREAKERENCLOSUREJUNCTIONBOXINVINVERTERUMUTILITYMETERPV SYSTEM10.980 kW-DC10.000 kW-ACFIRE ACCESSPATHWAYS(N) 36 REC SOLAR: REC305TP2M3'-0" 3'-0" 3'-0" 3'-0"3'-0"3'-0"3'-0"3' - 0 "3'-0"2 ROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCH ARRAY PITCHAZIMUTHROOF AREAARRAY AREA11119°19°90°581.18 SQ FT197.56 SQ FT2725°25°226°332.02 SQ FT125.72 SQ FT31819°19°270°814.5 SQ FT323.28 SQ FTPV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-ROOF DETAILS:TOTAL ROOF AREA: 2607.58 SQ FTARRAY COVERAGE: 24.80%SYSTEM DISTRIBUTED WEIGHT: 2.27 LBSSFM INFINITY \ ROCKIT MICRORAIL POINT-LOAD: 12.14 LBSROOF DETAILSGREG ALBRIGHT2 ROOF DECK /MEMBRANESLIDER AND TRIMRAILROOF ATTACHMENTBUILDING STRUCTURE5/16" STAINLESS STEEL LAGBOLT OR STRUCTURAL SCREWWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHER2.5"TRIMRAIL2.5" MIN. EMBED.FLASHINGROOF / DECK MEMBRANESLIDERSBUILDING STRUCTURE5/16" STAINLESS STEELLAG BOLT ORSTRUCTURAL SCREWWITH 2-1/2" MIN.EMBEDMENT AND FLATWASHER2.5"MICRORAILFLASHING2.5" MIN. EMBED.REC SOLAR: REC305TP2MREC SOLAR: REC305TP2MSLIDERSMICRORAIL2.5" MIN. EMBED .5/16" STAINLESS STEEL LAGBOLT OR STRUCTURAL SCREWWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHERTRIMRAIL2.5" MIN. EMBED.FLASHINGFLASHINGSLIDER AND TRIMRAIL ROOFATTACHMENT2X4 TRUSS @ 24" O.C.ROOF / DECK MEMBRANE3" MIN.MAX5" .REC SOLAR: REC305TP2M.\RL_array1.JPGATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPARTIAL ROOF FRAMING PLANScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-MOUNTING DETAILSGREG ALBRIGHTMAX ATTACHMENT SPAN - 4' STAGGERED2222 3 - #6 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 60A FUSEDAC DISCONNECTEATON DG222NRB (OREQUIVALENT)WITH 60A FUSES,KNIFEBLADE, LOCKABLE, NEMA3R, UL LISTEDSOLAREDGE P340 POWER OPTIMIZERSJUNCTIONBOXSTRING-12 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#8 AWG MUST BE IN EMT CONDUITSTRING-2SOLAREDGE P340POWER OPTIMIZERS2 - #10 AWG,PV WIRE19 REC SOLAR: REC305TP2M17 REC SOLAR: REC305TP2M4 - #10 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUIT(N) SOLAREDGESE10000H-USRGM [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCH1 - #6 GEC, BARE COPPERFREE AIR BONDEDEXISTING UFER TIE IN(E) 100A RATEDSUB PANEL1PH, 120/240V 60HZ(N) 100A / 2PSUB PANEL BREAKEREXISTING WIRE RUNTHROUGH CONDUIT(E) 100A RATEDMAIN BREAKER(END FED)UM(N) 200A / 2P MAINBREAKER(END FED)(N) 200A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITYMETER(N) LINESIDE TAP VIA ULLISTED CONNECTORTO UTILITYOVERHEADFEEDNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED FUSE SIZINGMAX. CONTINUOUS OUTPUT 42.00A @ 240V42.00X1.25= 53AMPS 60A FUSES - OKPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-THREE LINE DIAGRAMGREG ALBRIGHTPV SYSTEM10.980 kW-DC10.000 kW-AC222A TAPBOX MAY BE USED IN LIEU OF PERFORMING THE LINESIDETAP IN THE MAIN SERVICE PANEL. THIS IS DEPENDENT UPON SITECONDITIONS.3 - #6 AWG, THWN-2IN 3/4" OR LARGER EMT CONDUIT PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTWIRE LOCATIONCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DCMODULETOOPTIMIZERROOF / FREE-AIR2104012.551140.0015.692DCOPTIMIZERTOJUNCTION BOXROOF / FREE-AIR2104015.001140.0018.753DCJUNCTION BOXTOINVERTEREXTERIOR WALL4104015.0010.832.0018.754ACINVERTERTO AC DISCONNECTEXTERIOR WALL367542.001175.0052.505ACAC DISCONNECT TOPOIEXTERIOR WALL367542.001175.0052.50CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-QTY.PARTPART #DESCRIPTION36 MODULES117-305REC SOLAR: REC305TP2M36OPTIMIZERS130-340SOLAREDGE P340 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON1 JUNCTION BOX480-276600VDC NEMA 3R UL LISTED JUNCTION BOX2 CONNECTORS240-300STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)2 CONNECTORS240-301STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1 INVERTER120-103SOLAREDGE SE10000H-USRGM [SI1] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1 AC DISCONNECT323-06160A RATED 240VAC NEMA 3R UL LISTED2 FUSES330-06060A FUSE 1 PH 240VAC1 FUSE REDUCER330-510100A-60A FUSE REDUCER121 ROOF ATTACHMENT 1261 -602SFM INFINITY \ ROCKIT MICRORAIL26SFM TRIM 1241-253FLASHKIT SFM / ROCK-IT TRIM COMP DARK68SFM SLIDER 1261-603FLASHKIT SFM / ROCK-IT SLIDER COMP DARK20 BONDING CLAMP 1221-100N/S BONDING CLAMP8 BONDING CLAMP 1241-404TRIM BONDING CLAMP38MOUNT ASSEMBLY 1241-405MLPE MOUNT ASSY22SFM SPLICE 1261-604SFM / ROCK-IT SPLICE5SFM ATTACHED SPLICE 1211-101ATTACHED SPLICE 8 INCH30TRIMRAIL 1261-606TRIMRAIL UNIV CLIP W/ HDW9 TRIM SPLICE 1261-605TRIM SPLICE DRK16 TRIMRAIL 1211-115TRIMRAIL UNIV DRK36GROUND LUG 1260-585ILSCO GROUND LUG36 TRIM END CAPS 1221-200UNIRAC SFM / ROCK-IT TRIM END CAPSBREAKER SIZES:SERVICE LIST:TRUEEQUIPMENT & SERVICE LISTGREG ALBRIGHT2 NOTES:M690.54705.12(B)(2)(3)(b)"WARNING"DUAL POWER SOURCESSECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 42.00 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSWARNING:POWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE.TURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAY690.56(C)(1)(A)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC 690.15, 690.54PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 42.00 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)INVERTERARRAYJ/BDC"WARNING"ELECTRICAL SHOCK HAZARD.TERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITION690.13 (B)690.53NEC 690.31(G)(3) & (4)PMPV METERSOLAR ELECTRICPV PANELSPV SYSTEM DC DISCONNECTMAXIMUM VOLTAGE: 480VMAXIMUM CIRCUIT CURRENT: 27AMAX RATED OUTPUT CURRENT OFTHE CONTROLLER OR DC-TO-DCCONVERTER: 15ATURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNENTIRE PV SYSTEMNFPA 11.12.2.1.1.1.1SOLAR ELECTRICPV PANELSEMERGENCY RESPONDERTHIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION.ONLY CONDUCTORS INSIDEBUILDING OR OFF THEROOF WILL SHUT DOWNNFPA 11.12.2.1.1.1.2SOLAR ELECTRICPV PANELSEMERGENCY RESPONDERTHIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWN"WARNING"PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESPV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-LABELSGREG ALBRIGHT1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2. ALL MARKING SHALL CONSIST OF THE FOLLOWING:A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B. RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C. ARIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS CAUTION:POWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNPV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2. ALL MARKING SHALL CONSIST OF THE FOLLOWING:A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C. AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNHICKORY DRINVERTER EQUIPPEDWITH RAPID SHUTDOWNJUNCTION BOX36 PV MODULESAC DISCONNECTUTILITY METERMAIN SERVICE PANEL2 123456789101-10 11-20 21-30 31-40 41-50 51-60123456789101-10 11-20 21-30 31-40 41-50 51-60PV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHARTGREG ALBRIGHTHICKORY DR SAFETY PLANMARK UP KEYINSTRUCTIONS:1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2. SAFETY PLAN MUST BE MARKED BEFORE JOBSTARTS AS PART OF THE PRE-PLAN3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE& MAKE NOTES ON THE JHA SHEETIN CASE OF EMERGENCYNEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINICNAME: _______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATIONNAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THESAFETY PLAN AND SIGN INDICATING THAT THEY AREAWARE OF THE HAZARDS ON-SITE AND THE PLAN FORWORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OPV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-SAFETY PLANGREG ALBRIGHTHICKORY DR JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F121794DESIGNED BY:G.J.CLIENT:JOHN TRUETT5612 HICKORY DR, FORT PIERCE, FL 34982AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (352) 281-5782SYSTEM:SYSTEM SIZE (DC): 36 X 305 = 10.980 kWSYSTEM SIZE (AC): 10.000 kW @ 240VMODULES: 36 X REC SOLAR: REC305TP2MOPTIMIZERS: 36 X SOLAREDGE P340INVERTER: SOLAREDGE SE10000H-USRGM[SI1]DATE:3/7/2022G.J.3/2/20223/7/20222--1G.J.-SAFETY PLANGREG ALBRIGHT REC TwinPeak 2 Mono Series solar panels feature an innovative design with high panel efficiency and power output, enabling customers to get the most out of the space used for the installation.Combined with industry-leading product quality and the reliability of a strong and established European brand, REC TwinPeak 2 Mono panels are ideal for residential and commercial rooftops worldwide.PREMIUM SOLAR PANELSWITH SUPERIOR PERFORMANCErec TwinPeak 2 Mono SeriesMORE POWER OUTPUT PER M²IMPROVED PERFORMANCE IN SHADED CONDITIONS100% PID FREEREDUCES BALANCE OF SYSTEM COSTSPIDFree100%ELIGIBLE FORGRGRGRGR28 [1.1]1675±2.5 [65.94 ±0.1]910 [35.8]382.5 [15.05]956 [37.64]997±2.5 [39.25 ±0.1]17 [0.7]45 [1.5] 1000 [39]1200 [47]11±0.2[0.43 ±0.8]6.6±0.2 [0.26 ±0.08]20.5±0.5[0.78 ±0.08]45 [1.5] 38 [1.5]Ref: PM-DS-07-16 Rev- F 06.202019 TOP PERFORMERPV MODULERELIABILITY SCORECARD2020 TOP PERFORMERPV MODULERELIABILITY SCORECARDSpecifications subject to change without notice.www.recgroup.comREC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power in order to facilitate global energy transitions. Committed to quality and innovation, REC offers photovoltaic modules with leading high quality, backed by an exceptional low warranty claims rate of less than 100ppm. Founded in Norway in 1996, REC employs 2,000 people and has an annual solar panel capacity of 1.8 GW. With over 10 GW installed worldwide, REC is empowering more than 16 million people with clean solar energy. REC Group is a Bluestar Elkem company with headquarters in Norway, operational headquarters in Singapore, and regional bases in North America, Europe, and Asia-Pacific.REC TWINPEAK 2 MONO SERIESTEMPERATURE RATINGS Note! Specifications subject to change without notice.MAXIMUM RATINGSCERTIFICATIONSMECHANICAL DATAWARRANTYDimensions: 65.9 x 39.25 x 1.5 (1675 x 997 x 38 mm)Area: 17.98 ft² (1.67 m²)Weight: 40.8 lbs (18.5 kg)Nominal Module Operating Temperature: 44.6°C (±2°C)Temperature coefficient of PMAX: -0.37 %/°CTemperature coefficient of VOC: -0.28 %/°CTemperature coefficient of ISC: 0.04 %/°C19.8%2520EFFICIENCYYEAR PRODUCT WARRANTYYEAR LINEAR POWER OUTPUT WARRANTYUL 1703, Fire classification: Type 2; IEC 61215, IEC 61730; IEC 62804 (PID), IEC 62716 (Ammonia Resistance), IEC 61701 (Salt Mist Level 6), ISO 9001: 2015, ISO 14001: 2004, OHSAS 18001: 2007Operational temperature: -40 ... +185°F (-40 ... +85°C)Maximum system voltage: 1000 VDesign load (+): snow 3600 Pa (75.2 lbs/ft²)+ Maximum test load (+): 5400 Pa (112.8 lbs/ft²)*Design load (-): wind 1600 Pa (33.4 lbs/ft²)+ Maximum test load (-): 2400 Pa (50 lbs/ft²)*Max series fuse rating: 20 AMax reverse current: 20 A+ Calculated using a safety factor of 1.5 * See installation manual for mounting instructionsMeasurements in mm [in]GENERAL DATACells: 120 half-cut mono-Si p-type PERC cells 6 strings of 20 cells in seriesGlass: 0.13" (3.2 mm) solar glass with anti-reflective surface treatmentBack sheet: Highly resistant polyester polyolefin constructionFrame: Anodized aluminumJunction box: 3-part with 3 bypass diodes, IP67 rated 12 AWG (4 mm²) PV wire, 39" + 47" (1.0 m + 1.2 m)Connectors: Stäubli MC4 PV-KBT4/PV-KST4, 12 AWG (4 mm²)ELECTRICAL DATA @ STCProduct code*: RECxxxTP2MNominal Power - PMAX (Wp) 300 305 310 315 320 325 330Watt Class Sorting - (W)-0/+5 -0/+5 -0/+5 -0/+5 -0/+5 -0/+5 -0/+5Nominal Power Voltage - VMPP (V) 33.0 33.3 33.5 33.7 33.9 34.0 34.3Nominal Power Current - IMPP (A) 9.11 9.17 9.26 9.36 9.45 9.56 9.62Open Circuit Voltage - VOC (V) 38.3 38.8 39.1 39.6 40.0 40.3 40.8Short Circuit Current - ISC (A) 10.01 10.04 10.07 10.10 10.13 10.15 10.19Panel Efficiency (%) 18.0 18.3 18.6 18.9 19.2 19.5 19.8Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. At a low irradiance of 200 W/m² at least 95% of the STC module efficiency will be achieved. *Where xxx indicates the nominal power class (PMAX) at STC indicated above.ELECTRICAL DATA @ NMOTProduct code*: RECxxxTP2MNominal Power - PMAX (Wp) 224 227 231 235 239 242 246Nominal Power Voltage - VMPP (V) 30.7 31.0 31.2 31.4 31.6 31.7 31.9Nominal Power Current - IMPP (A) 7.29 7.34 7.41 7.49 7.56 7.65 7.70Open Circuit Voltage - VOC (V) 35.6 36.1 36.4 36.8 37.2 37.5 38.0Short Circuit Current - ISC (A) 8.01 8.03 8.06 8.08 8.10 8.12 8.15Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 20°C, windspeed 1 m/s). *Where xxx indicates the nominal power class (PMAX) at STC indicated above.StandardREC ProTrustInstalled by an REC Certified Solar ProfessionalNoYesYesSystem Size Any≤25 kW25-500 kWProduct Warranty (yrs)2025 25Power Warranty (yrs)2525 25Labor Warranty (yrs)025 10Power in Year 197.5%97.5% 97.5%Annual Degradation0.7% 0.7% 0.7%Power in Year 2580.7% 80.7% 80.7%See warranty documents for details. Some conditions apply. Power OptimizerFor North AmericaP320 / P340 / P370 / P400 / P401 / P405 / P485 / P50525YEARWARRANTYPV power optimization at the module-levelSpecifically designed to work with SolarEdgeinvertersUp to 25% more energySuperior efficiency (99.5%)Mitigates all types of module mismatch losses,from manufacturing tolerance to partialshadingFlexible system design for maximum spaceutilizationFast installation with a single boltNext generation maintenance with module-level monitoringMeets NEC requirements for arc faultprotection (AFCI) and Photovoltaic RapidShutdown System (PVRSS)Module-level voltage shutdown for installerand firefighter safetysolaredge.comPOWER OPTIMIZERPower OptimizerFor North AmericaP320 / P340 / P370 / P400 / P401 / P405 / P485 / P505Optimizer model(typical modulecompatibility)P320(for 60-cellmodules)P340(for high- power60-cellmodules)P370(for higher- power60 and 72- cellmodules)P400(for 72 &96-cellmodules) P401(for highpower 60and 72 cellmodules)P405(for high- voltagemodules)P485(for high- voltagemodules)P505(for highercurrentmodules)INPUTRated Input DC Power(1)320350370400485505 WAbsolute Maximum Input Voltage(Voc at lowest temperature)48 60 80 60125(2)83(2)VdcMPPT Operating Range8 - 488 - 608 - 808-6012.5 - 10512.5 - 83 VdcMaximum Short Circuit Current(Isc)11 11.02 11 10.1 11.75 11 14 AdcMaximum DC Input Current13.7512.514.6512.517.5 AdcMaximum Efficiency99.5 %Weighted Efficiency98.898.6 %Overvoltage CategoryIIOUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)Maximum Output Current15 AdcMaximum Output Voltage6085VdcOUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)Safety Output Voltage per PowerOptimizer1 ± 0.1 VdcSTANDARD COMPLIANCEEMCFCC Part15 Class B, IEC61000-6-2, IEC61000-6-3SafetyIEC62109-1 (class II safety), UL1741MaterialUL94 V-0, UV ResistantRoHSYesINSTALLATION SPECIFICATIONSMaximum Allowed SystemVoltage1000 VdcCompatible invertersAll SolarEdge Single Phase and Three Phase invertersDimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5/ 5.1 x 6 x 1.3129 x 153 x 29.5/ 5.1 x 6 x 1.16129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59/ 5.1 x 6.4 x 2.3mm/inWeight (including cables)630 / 1.4750 / 1.7 655 / 1.5845 / 1.91064 / 2.3 gr / lbInput ConnectorMC4(3)Single or dualMC4(3)(4)MC4(3)Input Wire Length0.16 / 0.520.16 or 0.9/0.52 or 2.95(5)0.16 / 0.52m / ftOutput Wire Type / ConnectorDouble Insulated / MC4Output Wire Length0.9 / 2.951.2 / 3.9m / ftOperating Temperature Range(6)-40 to +85 / -40 to +185Ü&/Ü)Protection RatingIP68 /7\SH 3Relative Humidity0-100 %  Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed  NEC 2017 requires max input voltage be not more than 80V  For other connector types please contact SolarEdge  For dual version for parallel connection of two modules use P485-4NMDMRM. Inthe case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals  Longer inputs wire length are available for use. For 0.9m input wire length order P401-xxxLxxx  For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for moredetailsPV System Design Using aSolarEdge Inverter(7)(8)Single PhaseHD-WaveSingle phaseThree Phase for208V gridThree Phase for277/480V gridMinimum String Length(Power Optimizers) P320, P340, P370,P400, P4018 1018P405, P485, P5056814Maximum String Length (Power Optimizers)252550(9)Maximum Power per String5700 (6000 withSE7600-US - SE11400- US)52506000(10)12750(11)W Parallel Strings of'L੔HUHQWLengths or Orientations Yes  )RUGHWDLOHGVWULQJVL]LQJLQIRUPDWLRQUHIHUWRKWWSZZZVRODUHGJHFRPVLWHVGHIDXOWILOHVVWULQJBVL]LQJBQDSGI  ,WLVQRWDOORZHGWRPL[333ZLWK33333LQRQHVWULQJ  $VWULQJZLWKPRUHWKDQRSWLPL]HUVGRHVQRWPHHW1(&UDSLGVKXWGRZQUHTXLUHPHQWVVDIHW\YROWDJHZLOOEHDERYHWKH9UHTXLUHPHQW  )RU9JULGLWLVDOORZHGWRLQVWDOOXSWR:SHUVWULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKVWULQJLV:  )RU9JULGLWLVDOORZHGWRLQVWDOOXSWR:SHUVWULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKVWULQJLV:© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date:/2021 DS-000044-1.-NA. Subject to change without notice. 40 INVERTERS solaredge.comOptimized installation with HD-Wave technology6SHFLÀFDOO\GHVLJQHGWRZRUNZLWKSRZHURSWLPL]HUV%XLOWLQPRGXOHOHYHOPRQLWRULQJ2XWGRRUDQGLQGRRULQVWDOODWLRQ2SWLRQDO5HYHQXHJUDGHGDWD$16,&&ODVV DFFXUDF\ 5HFRUGEUHDNLQJH඼FLHQF\)L[HGYROWDJHLQYHUWHUIRUORQJHUVWULQJV,QWHJUDWHGDUFIDXOWSURWHFWLRQDQGUDSLGVKXWGRZQIRU1(&DQGSHUDUWLFOHDQG([WUHPHO\VPDOO8/6$FHUWLÀHGIRU&38&5XOHJULGFRPSOLDQFHSingle Phase Inverter with HD-Wave Technologyfor North America6(+866(+866(+866(+866(+866(+866(+8612-25YEARWARRANTYSE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-USOUTPUT Rated AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAMaximum AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAAC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)9999999VacAC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-9-9--9VacAC Frequency (Nominal)59.3 - 60 - 60.5(1)HzMaximum Continuous Output Current @240V12.5 16 21 25 32 42 47.5 AMaximum Continuous Output Current @208V-16-24- -48.5AGFDI Threshold1AUtility Monitoring, Islanding Protection, &RXQWU\&RQÀJXUDEOH7KUHVKROGVYesINPUT Maximum DC Power @240V4650590077509300118001550017650 WMaximum DC Power @208V-5100-7750--15500 WTransformer-less, Ungrounded YesMaximum Input Voltage480VdcNominal DC Input Voltage380400VdcMaximum Input Current @240V(2)8.510.513.516.5202730.5 AdcMaximum Input Current @208V(2)-9-13.5--27AdcMax. Input Short Circuit Current45AdcReverse-Polarity ProtectionYesGround-Fault Isolation Detection 600k Sensitivity0D[LPXP,QYHUWHU(੕FLHQF\99 99.2 %&(&:HLJKWHG(੕FLHQF\9999 @ 240V98.5 @ 208V%Nighttime Power Consumption< 2.5 WADDITIONAL FEATURESSupported Communication InterfacesRS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20Optional(3)Rapid Shutdown - NEC 2014 and 2017 690.12Automatic Rapid Shutdown upon AC Grid DisconnectSTANDARD COMPLIANCE SafetyUL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07Grid Connection StandardsIEEE1547, Rule 21, Rule 14 (HI)EmissionsFCC Part 15 Class BINSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range1" Maximum / 14-6 AWG1" Maximum /14-4 AWGDC Input Conduit Size / # of Strings / AWG Range0D[LPXPᐎULQJV$:*0D[LPXPᐎULQJV$:*Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 17421.3 x 14.6 x 7.3 / 540 x 370 x 185in / mmWeight with Safety Switch22 / 1025.1 / 11.426.2 / 11.938.8 / 17.6OENJNoise < 25<50dBACoolingNatural ConvectionOperating Temperature Range -13 to +140 / -25 to +60(4) Ü)Ü&RSWLRQ (5)Ü)Ü&Protection Rating NEMA 4X (Inverter with Safety Switch)(1) For other regional settings please contact SolarEdge support (2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG (3) Revenue grade inverter P/N: SExxxxH-US000NNC2(4) For power de-rating information refer to: KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI(5) -40 version P/N: SExxxxH-US000NNU4 SE3000H-USSE3800H-USSE5000H-USSE6000H-USSE7600H-USSE10000H-USSE11400H-USOUTPUTRated AC Power Output30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAMaximum AC Power Output 30003800 @ 240V3300 @ 208V50006000 @ 240V5000 @ 208V76001000011400 @ 240V10000 @ 208VVAAC Output Voltage Min.-Nom.-Max.(211 - 240 - 264)9999999VacAC Output Voltage Min.-Nom.-Max.(183 - 208 - 229)-9-9--9VacAC Frequency (Nominal)59.3 - 60 - 60.5(1)HzMaximum Continuous Output Current @240V12.5162125324247.5AMaximum Continuous Output Current @208V-16-24--48.5AGFDI Threshold1AUtility Monitoring, Islanding Protection,&RXQWU\&RQÀJXUDEOH7KUHVKROGVYesINPUTMaximum DC Power @240V4650590077509300118001550017650WMaximum DC Power @208V-5100-7750--15500WTransformer-less, Ungrounded YesMaximum Input Voltage480VdcNominal DC Input Voltage380400VdcMaximum Input Current @240V(2)8.510.513.516.5202730.5AdcMaximum Input Current @208V(2)-9-13.5--27AdcMax. Input Short Circuit Current45AdcReverse-Polarity ProtectionYesGround-Fault Isolation Detection600k Sensitivity0D[LPXP,QYHUWHU(੕FLHQF\9999.2%&(&:HLJKWHG(੕FLHQF\9999 @ 240V98.5 @ 208V%Nighttime Power Consumption< 2.5WADDITIONAL FEATURESSupported Communication InterfacesRS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20Optional(3)Rapid Shutdown - NEC 2014 and2017 690.12Automatic Rapid Shutdown upon AC Grid DisconnectSTANDARD COMPLIANCESafetyUL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07Grid Connection StandardsIEEE1547, Rule 21, Rule 14 (HI)EmissionsFCC Part 15 Class BINSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range1" Maximum / 14-6 AWG1" Maximum /14-4 AWGDC Input Conduit Size / # of Strings / AWG Range0D[LPXPᐎULQJV$:*0D[LPXPᐎULQJV$:*Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 17421.3 x 14.6 x 7.3 / 540 x 370 x 185in / mmWeight with Safety Switch22 / 1025.1 / 11.426.2 / 11.938.8 / 17.6OENJNoise < 25<50dBACoolingNatural ConvectionOperating Temperature Range -13 to +140 / -25 to +60(4) Ü)Ü&RSWLRQ (5)Ü)Ü&Protection Rating NEMA 4X (Inverter with Safety Switch)(1) For other regional settings please contact SolarEdge support(2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG(3) Revenue grade inverter P/N: SExxxxH-US000NNC2(4) For power de-rating information refer to:KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI(5) -40 version P/N: SExxxxH-US000NNU4Single Phase Inverterwith HD-Wave Technology for North America6(+866(+866(+866(+866(+866(+866(+86Œ6RODU(GJH7HFKQRORJLHV,QF$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF$OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*1$06XEMHFWWRFKDQJHZLWKRXWQRWLFH pe.eaton.com Eaton general duty cartridgefuse safety switchDG222NRBUPC:782113144221Dimensions:Height:14.37 IN●Length:7.35 IN●Width:8.4 IN●Weight:10 LBNotes:Maximum hp ratings apply only when dualelement fuses are used. 3-Phase hp rating shown isa grounded B phase rating, UL listed.Warranties: Eaton Selling Policy 25-000, one (1) year fromthe date of installation of the Product oreighteen (18) months from the date of shipmentof the Product, whichever occurs first.●Specifications:Type:General duty, cartridge fused●Amperage Rating:60A●Enclosure:NEMA 3R●Enclosure Material:Painted galvanized steel●Fuse Class Provision:Class H fuses●Fuse Configuration:Fusible with neutral●Number Of Poles:Two-pole●Number Of Wires:Three-wire●Product Category:General duty safety switch●Voltage Rating:240V●Supporting documents:Eatons Volume 2-Commercial Distribution●Eaton Specification Sheet - DG222NRB●Certifications: UL Listed●Product compliance:No Data______________________________________________________________________© 2016 Eaton. All rights reserved. The RockIt system is the industry’s premier rail-less PV racking system for composition shingle, tile, and metal roofs. Designed in conjunction with the needs of installers, RockIt quickly & easily installs with a single tool. Featuring an easy-to-position alignment slide and a top-down leveling system, RockIt is logistically intelligent with no need to ship or transport long rails. Components are DYDLODEOHLQDEODFNȴQLVKWKDWFRPSOHPHQWVERWKFRPPHUFLDOand residential applications. Conforms to UL 2703. FEATURES & BENEFITS• Patented watertight technology • Fully integrated bonding• Top-down leveling system•North-South adjustability• Single tool installCOMPLETE RAIL-LESS RACKING SYSTEMSTREAMLINED INSTALLATION WITH MINIMAL ROOF PENETRATIONSComposition Shingle, Tile, MetalRail-LessStructural-Attach Direct-AttachECOFASTENSOLAR.COMFRAME MLPE MOUNT Attaches and fully bonds MLPE’s (Module Level Power Electronics) to the module frame with a single bolt clip.COUPLING The fast installing RockIt Coupling easily attaches to the module frame to bridge the gaps between modules. ROCKIT SLIDEAvailable in three variations, the RockIt Slide allows installation on composition shingle, tile, and metal roofs.SKIRTThe sleek black Skirt installs first and acts as an alignment guide for the entire array. The Skirt End Cap does double duty as a skirt coupling device and an aesthetically-pleasing finishing touch.ROCKIT MOUNTFeaturing integrated bonding pins, the RockIt Mount connects to the Slide and can easily be positioned for fast installation. Features top-down leveling. Take your business to the next level with SFM INFINITY, UNIRAC’s rail-less PV mounting system for flush mount installations on comp shingle and tile roofs. An advanced 3rd generation product platform in use by top solar contractors nationwide, SFM INFINITY optimizes your operations on and off the roof, with approximately 40% less labor, 30% logistics savings, and 20% fewer roof attachments than traditional solar racking. Plus, 87% of homeowners prefer SFM INFINITY’s aesthetics.SUPERIOR PERFORMANCEEnhance your business with two installs per dayand 30% less cost.EASY INSTALLATIONPre-assembled components, 20% fewer roof attachments, and level array in seconds with post height adjustment. HOMEOWNER PREFERREDMore than 4 out of 5 homeowners prefer SFM INFINITY’S aesthetics over a leading rail brand.SFM INFINITYFRONT TRIM AND END CAPSUNIVERSAL COMPONENTSFIT 32 – 40MM MODULESEOWNERPREFERRED25 YEAR FULL-SYSTEM WARRANTYONE SKU FITS 32 TO 40mmREVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702REVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702SFM INFINITYDESIGN GUIDELINESAPPLICATION GUIDEWhile you will see advantages simply from switching to SFM INFINITY, the following guidelines will help you to maximize its benefits.When possible, design in landscape orientation in order to fit more modules on the roof and minimize roof attachments.DEFAULT TO LANDSCAPESFM INFINITY is easily configured in mixed array shapes and module orientations to maximize array density and to avoid vent pipes and other obstacles. Because mounting locations are not constrained by rails, SFM INFINITY has unmatched flexibility to enhance your projects.MIX MODULE ORIENTATIONSVisit UNIRAC’s mobile-friendly library of short, topic-specific videos which answer common questions and demonstrate how simple it is to install SFM INFINITY.CONSULT THE QUICK TIPS VIDEOSQuick Tips Videos: https://unirac.com/SFM-Infinity/ Layout your arrays in U-Builder, UNIRAC’s free solar design software, to optimize SFM INFINITY’S capabilities, including mixing module orientations and minimizing roof attachments. Quickly create layouts on Google or Bing Maps and generate project documents.DESIGN IN U-BUILDERU-Builder: https://design.unirac.com/ Report No. 102393982LAX-002Unirac, IncPage 2 of 107Issued: 11-Apr-2016Revised: 20-Mar-2019Product Brand nameModelsUnirac SFM2.0 Product DescriptionPhotovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20UniracDescriptionThe product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground.The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame to contact the metal, creating a bonded connection from module to module.The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to thenational electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same engage cable.ED 16.3.15 (20-Apr-17) MandatoryReport No. 102393982LAX-002Unirac, IncPage 3 of 107Issued: 11-Apr-2016Revised: 20-Mar-20192.0 Product DescriptionModel SimilarityOther RatingsNAFuse Rating: 30AModule Orientation: Portrait or LandscapeMaximum Module Size: 17.98 ftϸUL2703 Design Load Rating:33 PSF Downward, 33 PSF Upward, 10 PSF Down-SlopeTested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down SlopeTrina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical LoadingIncreased size ML test:Maximum Module Size: 22.3 ft²UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-SlopeLG355S2W-A5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24"UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope LG395N2W-A5, LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" Fire Class Resistance Rating:- Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at anyinterstitial gap. Installations must include Trim Rail.- Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at anyinterstitial gap. Installations must include Trim Rail.- Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules.This system was evaluated with a 5” gap between the bottom of the module and the roof’ssurfaceSee section 7.0 illustraction # 1 and 1a for a complete list of PV modules evaluated with these racking systemsRatingsNAED 16.3.15 (20-Apr-17) Mandatory AUTHORIZATION TO MARKApplicant:Manufacturer:Address:Address:Country:Country:Contact: Contact:Phone: Phone:FAX: FAX:Email: Email:Standard(s):Product:Brand Name:Models:This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.Intertek Testing Services NA Inc.545 East Algonquin Road, Arlington Heights, IL 60005Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1]Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20Unirac SFMUniracControl Number:5003705Authorized by: for Dean Davidson, Certification ManagerThis document supersedes all previous Authorizations to Mark for the noted Report Number.klaus.nicolaedis@unirac.comtoddg@unirac.comjia.liu@cxymj.combuwan.luo@cxymj.comParty Authorized To Apply Mark:Same as ManufacturerReport Issuing Office:Lake Forest, CA U.S.A.Klaus NicolaedisTom YoungJia LiuRobin Luo505-462-2190 505-843-1418+86-15267030962+86-13621785753NA NAUnirac, Inc Cixi Emeka Aluminum Co. Ltd1411 Broadway Blvd NEAlbuquerque, NM 87102No. 688 ChaoSheng RoadCixi CityZhejiang Province 315311USA ChinaThis authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)Covered section when made in accordance with the conditions set forth in the Certification Agreement and ListingReport. This authorization also applies to multiple listee model(s) identified on the correlation page of the ListingReport.This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may beapplied only at the location of the Party Authorized To Apply Mark.Page 1 of 1 ATM for Report 102393982LAX-002 ATM Issued: 9-Apr-2019ED 16.3.15 (20-Apr-17) Mandatory ĐŽ&ĂƐƚĞŶ^ŽůĂƌ>>ϰϭϰϭtsĂŶƵƌĞŶ^ƚ͕^ƚĞϮWŚŽĞŶŝdž͕ϴϱϬϬϵd>͗;ϴϳϳͿϴϱϵͲϯϵϰϳƚƚŶ͗͘ĐŽ&ĂƐƚĞŶ^ŽůĂƌ>>ͲŶŐŝŶĞĞƌŝŶŐĞƉĂƌƚŵĞŶƚ^ƵďũĞĐƚ͗ŶŐŝŶĞĞƌŝŶŐĞƌƚŝĨŝĐĂƚŝŽŶĨŽƌƚŚĞ^ƚĂƚĞŽĨ&ůŽƌŝĚĂƵŝůĚŝŶŐŽĚĞƐ͗ ϭ͘ ^ͬ^/ϳͲϭϲ͕DŝŶŝŵƵŵĞƐŝŐŶ>ŽĂĚƐĨŽƌƵŝůĚŝŶŐƐĂŶĚKƚŚĞƌ^ƚƌƵĐƚƵƌĞƐ͕ďLJŵĞƌŝĐĂŶ^ŽĐŝĞƚLJŽĨŝǀŝůŶŐŝŶĞĞƌƐϮ͘ ϮϬϮϬ&ͲƵŝůĚŝŶŐ͕ϳƚŚĚŝƚŝŽŶ͕ĂƐĞĚŽŶϮϬϭϴ/ŶƚĞƌŶĂƚŝŽŶĂůƵŝůĚŝŶŐŽĚĞϯ͘ ϮϬϮϬ&RͲZĞƐŝĚĞŶƚŝĂů͕ϳƚŚĚŝƚŝŽŶ͕ĂƐĞĚŽŶϮϬϭϴ/ŶƚĞƌŶĂƚŝŽŶĂůZĞƐŝĚĞŶƚŝĂůŽĚĞϰ͘ ϰϮϴ͕ĐĐĞƉƚĂŶĐĞƌŝƚĞƌŝĂĨŽƌDŽĚƵůĂƌ&ƌĂŵŝŶŐ^LJƐƚĞŵƐhƐĞĚƚŽ^ƵƉƉŽƌƚWŚŽƚŽǀŽůƚĂŝĐ;WsͿWĂŶĞůƐ͕EŽǀĞŵďĞƌϭ͕ϮϬϭϮďLJ/Ͳ^ϱ͘ ůƵŵŝŶƵŵĞƐŝŐŶDĂŶƵĂůϮϬϭϱ͕ďLJdŚĞůƵŵŝŶƵŵƐƐŽĐŝĂƚŝŽŶ͕/ŶĐ͘ϲ͘ E^/ͬtE^ͲϮϬϭϴ͕EĂƚŝŽŶĂůĞƐŝŐŶ^ƉĞĐŝĨŝĐĂƚŝŽŶĨŽƌtŽŽĚŽŶƐƚƌƵĐƚŝŽŶ͕ďLJƚŚĞŵĞƌŝĐĂŶtŽŽĚŽƵŶĐŝůĞƐŝŐŶƌŝƚĞƌŝĂ͗ ZŝƐŬĂƚĞŐŽƌLJ//^ĞŝƐŵŝĐĞƐŝŐŶĂƚĞŐŽƌLJсͲdžƉŽƐƵƌĞĂƚĞŐŽƌLJс͕ΘĂƐŝĐtŝŶĚ^ƉĞĞĚ;ƵůƚŝŵĂƚĞͿƉĞƌ^ϳͲϭϲсϵϬŵƉŚƚŽϭϴϬŵƉŚ'ƌŽƵŶĚ^ŶŽǁ>ŽĂĚсϬƚŽϲϬ;ƉƐĨͿdŚŝƐůĞƚƚĞƌĐĞƌƚŝĨŝĞƐƚŚĂƚƚŚĞůŽĂĚŝŶŐĐƌŝƚĞƌŝĂĂŶĚĚĞƐŝŐŶďĂƐŝƐĨŽƌƚŚĞĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵ^ƉĂŶdĂďůĞƐĂƌĞŝŶĐŽŵƉůŝĂŶĐĞǁŝƚŚƚŚĞĂďŽǀĞĐŽĚĞƐ͘/ĨLJŽƵŚĂǀĞĂŶLJƋƵĞƐƚŝŽŶƐŽŶƚŚĞĂďŽǀĞ͕ĚŽŶŽƚŚĞƐŝƚĂƚĞƚŽĐĂůů͘WƌĞƉĂƌĞĚďLJ͗W^͕/ŶĐ͘ʹ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌƐZŽƐĞǀŝůůĞ͕DĂLJϮϭ͕ϮϬϮϭW^͕/ŶĐ͘ʹ^ƚƌƵĐƚƵƌĂůŶŐŝŶĞĞƌƐŚĂƐƉƌŽǀŝĚĞĚĞŶŐŝŶĞĞƌŝŶŐĂŶĚƐƉĂŶƚĂďůĞƐĨŽƌƚŚĞĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵ͕ĂƐƉƌĞƐĞŶƚĞĚŝŶW^ZĞƉŽƌƚηϮϬϭϱͲϬϱϴϴϰ,'͘Ϭϳ͘Ϭϭ͕ΗŶŐŝŶĞĞƌŝŶŐĞƌƚŝĨŝĐĂƚŝŽŶĨŽƌƚŚĞĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵĨŽƌ'ĂďůĞĂŶĚ,ŝƉZŽŽĨƐΗ͘ůůŝŶĨŽƌŵĂƚŝŽŶ͕ĚĂƚĂ͕ĂŶĚĂŶĂůLJƐŝƐƚŚĞƌĞŝŶĂƌĞďĂƐĞĚŽŶ͕ĂŶĚĐŽŵƉůLJǁŝƚŚ͕ƚŚĞĨŽůůŽǁŝŶŐďƵŝůĚŝŶŐĐŽĚĞƐĂŶĚƚLJƉŝĐĂůƐƉĞĐŝĨŝĐĂƚŝŽŶƐ͗ZĞ͗ZĞƉŽƌƚηϮϬϭϱͲϬϱϴϴϰ,'͘Ϭϳ͘ϬϭʹĐŽ&ĂƐƚĞŶͲZŽĐŬ/ƚ^LJƐƚĞŵĨŽƌ'ĂďůĞĂŶĚ,ŝƉZŽŽĨƐEXP. 02/28/2023ZACHERPAULK.ENSECILARIDAOLFNOISSEFORP LENGINEERSTATE OFNo. 7352205/21/2021THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY PAULK. ZACHER, PE ON 05/21/2021 USING A SHA-1 AUTHENTICATION CODE.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNEDAND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.