Loading...
HomeMy WebLinkAboutProject Information (2)-�+ wrightsofto Project Summary (Rest of House) Project Information For: MW-1007 9412 MEADOWOOD DR, FORT PIERCE, FL34951 Notes: Design Information Weather: St Lucie Co Inti, FL, US Job: Date: Sep 13, 2021 By. Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 91 OF Inside db 70 OF Inside db 72 OF Design TD 29 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Structure 24236 Btuh Ducts 3511 Btuh Central vent (0 cfm) 0 Btuh (none) ' Humidification 0 Btuh Piping 0 Btuh Equipment load 27747 Btuh Infiltration Method Simplified Construction quality Semi -tight 0 Fireplaces Heatingg Cool"ngg Area (ft2) 1985 1985 Volume (ft3) 20814 20814 Air.changes/hour 0.19 0.10 Equiv AVF (cfm) 67 33 Heating Equipment Summary Make Trade Model AHRI ref Efficiency 100 EFF Heating input 10.1 kW Heating output 34434 Btuh Temperature rise 27 OF Actual airflow 1153 cfm Airflowfactor 0.042 cfm/Btuh Static pressure 0 in H2O • Space thermostat Sensible Cooling Equipment Load Sizing Structure 20865 Btuh Ducts 4091 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Equipment sensible load 24008 Btuh Latent Cooling Equipment Load Sizing Structure 7558 Btuh Ducts 1445 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 9003 Btuh Equipment Total Load (Sen+Lat) 33011 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Lennox Trade LENNOX Cond ML14XClS036-230C** Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 13.0 EER,16 SEER Sensible cooling 24220 Btuh Latentcooling 10380 Btuh Total cooling 34600 Btuh Actual airflow 1153 cfm Airflowfactor 0.046 cfrnBtuh Static pressure 0 in H2O Load sensible heat ratio 0.73 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. C -PW 2021Sep-1411:10:13 �... •�••t w^- Right-Sute®Urnversal202121.0.05RSU29964 Page s1ArryUseMocunerts\WdgMsoftHVAC1MW-1007.nip Calc=MJ6 FrordDoorfaces: S + wrightsoft® Project Summary MASTER AHU Project Inf• • For: MW-1007 9412 MEADOWOOD DR, FORT PIERCE, FL34951 Notes: Job: Date: Sep 13, 2021 By. Design • • Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer.Design Conditions Outside db 41 OF Outside db 91 OF Inside db 70 OF Inside db 72 OF Design TD 29 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing • Structure 11398 Btuh Structure 9434 Btuh Ducts 1319 Btuh Ducts 1596 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 dim) 0 Btuh (none) (none) ' Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12717 Btuh Use manufacturer's data n Rate/swingg multipplier 0.96 Infiltration Equipmentsensibleload 10611 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 3428 Btuh Ducts 590 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft�) 819 819 Equipment latent load 4017 Btuh Volume (fF) 7768 7768 Air changes/hour 0.29 0.15 Equipment Total Load (Sen+Lat) 14628 Btuh Equiv AVF (cfm) 38 19 Req. total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S018-230A** AHRI ref Coil CBA27UHE-018-230*++TDR AHRI ref 10259433 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating Input 3.7 kW Sensible cooling 12600 Btuh Heating output 12717 Btuh Latent cooling 5400 Btuh Temperature rise 19 OF Total cooling 18000 Btuh Actual airflow 600 cfm Actual airflow 600 chn Airflowfactor 0.047 cfmBtuh Airflowfactor 0.054 ofmBtuh Static pressure 0 in H2O Static pressure 0 in H2O . Space thermostat Load sensible heat ratio 0.73 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C -Pk- wrightsoft® 2021-Sep-1411:10:13 •-^w �- Right -Suite® Uriversal 2021 21.0.05 RSU29964 Page 2 ..s1ArryUserlDoamerts\WrightsoftWACWIW-1007.np CaIc=NU8 Frorft Door faces: S �rn O In I- 0 0 0� 7- OU Q 0Of W w CU-z 1.STON CU-1 3.STON J -�- wrightsoft® Load Short Form MASTER AHU Job: Date: Sep 13, 2021 By. Project Inf• • For: MW-1007 9412 MEADOWOOD DR,, FORT PIERCE, FL34951 Htg Clg Outside db (OF) 41 91 Inside db (OF) 70 72 Design TD (OF) 29 19 Daily range - L Inside humidity (%) 30 50 Moisture difference (grAb) 2 60 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 3.7 kW 12717 Btuh 19 OF 600 cfm 0.047 cfmBtuh 0 in H2O Infiltration Method Construction quality Fireplaces Simplified Semi -tight 0 COOLING EQUIPMENT Make Lennox Trade LENNOX Cond MI14XC1S018-23W* Coil CBA27UHE-018-230*++TDR AHRI ref 10259433 Efficiency 13.0 EER, 16 SEER Sensible cooling 12600 Btuh Latent cooling 5400 Btuh Total cooling 18000 Btuh Actual airflow 600 cfm Airflowfactor 0.054 cfmBtuh Static pressure 0 in H2O Load sensible heat ratio 0.73 ROOM NAME Area Htg load Clg load HtgAVF CIgAVF P) (Btuh) (Btuh) (cfm) 0111) MASTER SUITE 333 6147 5550 290 302 HIS WIC 53 880 493 42 27 MASTER BATH 159 1654 1994 78 108 HER W IC 74 62 301 3 16 DEN 201 3973 2691 187 146 MASTERAHU 819 12717 11030 600 600 Other equip loads 0 0 Equip. @ 0.96 RSM 10611 Latent cooling 4017 TnTAI C 010 17717 1AG27Q iznn cnn Calculations approved byACCAto meet all requirements of Manual J 8th Ed. = -*- wrightsoft® 2021-Sep-1411:10:13 '�- AMR•�•r�, �• v..,�mw•, Right-Sute®Uriversal2021 21.0.05 RSU29964 Page 3 ..s1AyUseADocLanerrMWdghtsoftWAC1MW-1007.rup Calc=MJ8 FrordDoorfaces: S