Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Revision
OFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 RECEIVED (772) 462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS FEB 2 5 2022 PROJECT INFORMATION St. Lucie County Permitting LOCATION/SITE ADDRESS: -5 5-�. /Ua�IQ�, ���✓e Few �iercC, Ft. DETAILED DESCRIPTION OF PROJECT REVISIONS: /1laa��'� ,� Caics „d Plans � aes 1 , M) 4-f1 CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: e-a BUSINESS NAME: 5I. ) ,_ QUALIFIERS NAME: ADDRESS: �d CITY: Foy-,- ��. e,� STATE: PHONE (DAYTIME): 7 y 2, y 6 q-1 /l7 OWNER/BUILDER INFORMATION: NAME: �) 4. ADDRESS: - ' CITY: IsAr- PHONE (DAY ST. LUCIE CO CERT. #: FAX: - (, FL * STATE: F L -7 ti 2- y 6 9!!17 FAX: ARCHITECT/ENGINEER INFORMATION: NAME: 1,kj e. ADDRESS: WLl sc s+- )u cr Q J!) CITY: c-I- e r Le PHONE DAYTIME): ZIP: -� y FILE COPY ZIP: Sgq_s O TE: FL ZIP: y q y FAX: SLCCC. 9123109 A"N lL) Revised 06/30/17 tlFVlS FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY -PERFORMANCE INDEX* = 98 T ; ° Sh oCr h `E r` e0ormance Index, the more efficient the home. LOT 5-6 Notlem Drive,Fort Pierce,FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows** Description a. U-Factor: Dbl, U=0.60 SHGC: SHGC=0.24 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description U-Factor:(AVG) N/A SHGC(AVG): N/A 9. Floor Types Insulation a. Slab -On -Grade Edge Insulation R= 0.0 b. N/A R= c. N/A R= 3 No 1292 0 Area 85.14 ft2 ft2 10. Wall Types(1248.0 sgft.) Insulation a. Concrete Block - Int Irisul, Exterior R=5.0 b. Concrete Block - Int Insul, AdjacenR=5.0 c. N/A R= d. N/A R= 11. Ceiling Types(1292.0 sqft.) Insulation a. Under Attic (Vented) R=30.0 b. N/A R= c. N/A R= 12. Ducts, location & insulation level a. a. Sup: Attic, Ret: Attic, AH: Laundry b. C. Area 1080.00 ft2 168.00 ft2 ft2 ft2 Area 1292.00 ft2 ft2 ft2 R ft2 6 258 13. Cooling Systems kBtu/hr Efficiency ft2 a. Central Unit 27.6 SEER:16.00 2.000 ft 0.240 14. Heating Systems kBtu/hr Efficiency Area a. Electric Strip Heat 27.3 COP:1.00 N/A ft2 15. Hot Water Systems Area 1291.00 ft2 a. Electric Cap: 40 gallons f EF: 0.950 2 b. Conservation feat LE COPY None 16, Credits CV I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. BuilderSignature: L T ���Date: 3 1ZZ- Address of New Home: LOT 5-6 Notlem Drive City/FL Zip: Fort Pierce, FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/3/2022 3:30:41 PM EnergyGauge® USA 7.0:00 - FlaRes202O FBC 7th Edition (2020) Compliant Software WE MPS o �ou�� S'�• puecm����9 Page 1 of 1 _e'en -* Zo Z.- o v.2(j FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LOT 5 and 6 Notlem Drive Fort Pierce Builder Name: - Habitat for'Humanity Street: LOT 5-6 Notlem Drive Permit Office: City, State, Zip: Fort Pierce, FL, Permit Number: Owner: Joseph Gianna Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1248.0 sqft.) Insulation Area 2. Single family or multiple:family Detached a. Concrete Block - Int Insul, Exterior R=5.0 1080.00 ft2 b. Concrete Block - Int Insul, AdjacenR=5.0 168.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types(1292.0 sqft.) Insulation Area 6. Conditioned floor area above.grade (ft2) 1292 a. Under Attic (Vented) b. N/A R=30.0 1292.00 ft2 R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(85.1 sqft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Dbl, U=0.60 85.14 ft2 a. a. Sup: Attic, Ret: Attic, AH: Laundry 6 258 SHGC: SHGC=0.24 b. b. U-Factor: N/A ft2 C. SHGC: 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 27.6 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft Area Weighted Average SHGC: 0.240 14. Heating Systems kBtu/hr - Efficiency 8. Skylights Description - Area a. Electric Strip Heat 27.3 COP:1.00 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area 15. Hot Water Systems a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R= 0.0 1291.00 ft2 EF: 0.950 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 16. Credits - CV Glass/Floor Area: 0.066 Total Proposed Modified Loads: 40.83 PASS Total Baseline Loads: 41.67 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this p4 TYiB ST Code. calculation indicates compliance ( ),, PGG with the Florida Energy. Code. PREPARED BY: Before construction is completed February 3, 2022 this building will be inspected for oa DATE: _ compliance with Section 553.908 n Florida Statutes. �'cODv5 I hereby certify that this building, as designed, is in compliance WE with the Florida E elMy Co OWNER/AGENT: l BUILDING OFFICIAL: DATE: iZ DATE: - Compliance requires. certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNET/ICC 396, is not greater than 0.060 On for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 3/3/2022 3:28:32 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LOT 5 and 6 Notlem Drive Fort Pierce Address type: Street Address Building Type: User Bedrooms: 3 Lot #: -- Owner: Joseph Gianna Conditioned Area: 1292 Block/SubDivision: - Total Stories: 1 PlatBook: - Builder Name: Habitat for Humanity Worst Case: No Street: LOT 5-6 Notlem Drive Permit Office: Rotate Angle: 0 County: St. Lucie Jurisdiction: Cross Ventilation: Yes City, State, Zip: Fort Pierce, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO-BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1292 10336 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 BEDROOM 3 131 1048 No 1 1 Yes Yes Yes -2 KITCHEN 116 928 Yes 0 Yes Yes Yes -3 pnty 11 88 No 0 No Yes Yes _ 4 BATH 50 396 No 0 No Yes Yes _ 5 Laundry 72 572 No 0 Yes Yes Yes _ 6 BATH 1 66 528 No 0 Yes Yes Yes _ 7 Master Bed 162 1296 'No 2 1 Yes Yes Yes _ 8 M CL 25 196 No 0 Yes Yes Yes _ 9 BEDROOM 2 144 1152 No 1 1 Yes Yes Yes _ 10 CL 3 15 120 No 0 No Yes Yes _ 11 CL 2 16 130 No 0 Yes Yes Yes _ 12 Hall 61 488 No 0 No Yes Yes 13 LIVING ROOM 423 3384 No 0 Yes Yes Yes FLOORS (Total Exposed Area = 1291 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins BEDROOM 3 10.5 131.3 ft 0.710 - 1.00 0.00 0.00 -2 Slab -On -Grade Edge Ins KITCHEN 21.5 115.5 ft 0.710 - 1.00 0.00 0.00 -3 Slab -On -Grade Edge Ins pnty 1 11 ft 0.710 - 1.00 0.00 0.00 _ 4 Slab -On -Grade Edge Ins BATH 1 49.5 ft 0.710 - 1.00 0.00 0.00 _ 5 Slab -On -Grade Edge Ins Laundry 11 71.5 ft 0.710 - 1.00 0.00 0.00 _ 6 Slab -On -Grade Edge Ins BATH 1 5.5 66 ft 0.710 - 1.00 0.00 0.00 _ 7 Slab -On -Grade Edge Ins Master Bed 25.5 162 ft 0.710 - 1.00 0.00 0.00 _ 8 Slab -On -Grade Edge Ins M CL 3.5 24.5 ft 0.710 - 1.00 0.00 0.00 _ 9 Slab -On -Grade Edge Ins BEDROOM 2 24 143.8 ft 0.710 - 1.00 0.00 0.00 _ 10 Slab -On -Grade Edge Ins CL 3 1 15 ft 0.710 - 1.00 0.00 0.00 _ 11 Slab -On -Grade Edge Ins CL 2 2.5 16.3 ft 0.710 - 1.00 0.00 0.00 _ 12 Slab -On -Grade Edge Ins Hall 1 61.3 ft 0.710 - 1.00 0.00 0.00 13 Slab -On -Grade Edge Ins LIVING ROOM 52 423.3 ft 0.710 - 1.00 0.00 0.00 3/3/2022 3:28:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch ✓# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1361 ft' 214 ft' Medium N 0.9 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1291 ft' N N CEILING (Total Exposed Area = 1292 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type _ 1 Under Attic(Vented) BEDROOM 3 30.0 Blown 131.0ft' 0.053 0.10 Wood -2 Under Attic(Vented) KITCHEN 30.0 Blown 116.0ft' 0.053 0.10 Wood -3 Under Attic(Vented) pnty 30.0 Blown 11.0ft' 0.053 0.10 Wood _ 4 Under Attic(Vented) BATH 30.0 Blown 50.0ft' 0.053 0.10 Wood _ 5 Under Attic(Vented) Laundry 30.0 Blown 72.0ft' 0.053 0.10 Wood -6 Under Attic(Vented) BATH 1 30.0 Blown 66.0ft' 0.053 0.10 Wood _ 7 Under Attic(Vented) Master Bed 30.0 Blown 162.0ft' 0.053 0.10 Wood _ 8 Under Attic(Vented) M CL 30.0 Blown 25.0ft' 0.053 0.10 Wood _ 9 Under Attic(Vented) BEDROOM 2 30.0 Blown 144.0ft' 0.053 0.10 Wood _ 10 Under Attic(Vented) CL 3 30.0 Blown 15.0ft' 0.053 0.10 Wood _ 11 Under Attic(Vented) CL 2 30.0 Blown 16.0ft' 0.053 0.10 Wood _ 12 Under Attic(Vented) Hall 30.0 Blown 61.0ft' 0.053 0.10 Wood 13 Under Attic(Vented) LIVING ROOM 30.0 Blown 423.0ft' 0.053 0.10 Wood WALLS (Total Exposed Area = 1248 sq.ft.) Cavity Width Height Area U- Sheath Frm. Solar Below ✓Adjacent # Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 W Exterior Cone. Blk - Int Ins BEDROOM 3 5.0 10.0 6 8.0 0 84.0 0.132 0 0 0.50 0 % -2 E Exterior Cone. Blk - Int Ins KITCHEN 5.0 10.0 6 8.0 0 84.0 0.132 0 0 0.50 0 % -3 N Garage Cone. Blk - Int Ins KITCHEN 5.0 11.0 0 8.0 0 88.0 0.132 0 0 0.50 0 % _ 4 E Exterior Cone. Blk - Int Ins Laundry 5.0 11.0 0 8.0 0 88.0 0.132 0 0 0.50 0 % _ 5 E Exterior Cone. Blk - Int Ins BATH 1 5.0 5.0 6 8.0 0 44.0 0.132 0 0 0.50 0 % -6 E Exterior Cone. Blk - Int Iris Master Bed 5.0 13.0 6 8.0 0 108.0 0.132 0 0 0.50 0 % _ 7 S Exterior Cone. Blk - Int Ins Master Bed 5.0 12.0 0 8.0 0 96.0 0.132 0 0 0.50 0 % _ 8 S Exterior Cone. Blk - Int Ins M CL 5.0 3.0 6 8.0 0 28.0 0.132 0 0 0.50 0 % _ 9 S Exterior Cone. Blk - Int Ins BEDROOM 2 5.0 12.0 6 8.0 0 100.0 0.132 0 0 0.50 0 % _ 10 W Exterior Cone. Blk - Int Ins BEDROOM 2 5.0 11.0 6 8.0 0 92.0 0.132 0 0 0.50 0 % _ 11 W Exterior Cone. Blk - Int Ins CL 2 5.0 2.0 6 8.0 0 20.0 0.132 0 0 0.50 0 % _ 12 N Exterior Cone. Blk - Int Ins LIVING ROOM 5.0 16.0 6 8.0 0 132.0 0.132 0 0 0.50 0 % _ 13 W Exterior Cone. Blk - Int Ins LIVING ROOM 5.0 25.0 6 8.0 0 204.0 0.132 0 0 0.50 0 % _ 14 E Garage Cone. Blk - Int Ins LIVING ROOM 5.0 9.0 6 8.0 0 76.0 0.132 0 0 0.50 0 % 15 N Garage Cone. Blk - Int Ins LIVING ROOM 5.0 0.0 6 8.0 0 4.0 0.132 0 0 0.50 0 % DOORS (Total Exposed Area = 43 sq.ft.) / Width Height ` V # Omt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area -1 N Exterior Wood LIVING ROOM None 0.39 3.00 0 7.00 0 21.0ft' 2 W Exterior Wood LIVING ROOM None 0.39 3.00 2 7.00 0 22.2ft' 3/3/2022 3:28:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 " FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 85 sq.ft.) Wall --Overhang-- V# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening _ 1 W 1 None Double (Clear) Yes 0.60 0.24 Y N 16.9ft2 2.0 ft 0 in 1.0 ft 0 in Drapes/blinds Exterior 50% -2 E 2 None Double (Clear) Yes 0.60 0.24 Y N 10.0ft2 2.0 ft 0 in 1.0 ft 0 in Drapes/blinds Exterior 50% 3 S 7 None Double (Clear) Yes 0.60 0.24 Y N 16.9ft2 2.0 ft 0 in 1.0 ft 0 in Drapes/blinds Exterior 50% 4 S 9 None Double (Clear) Yes 0.60 0.24 Y N 16.9ft2 2.0 ft 0 in 1.0 ft 0 in Drapes/blinds Exterior 50% _ 5 N 12 None Double (Clear) Yes 0.60 0.24 Y N 24.02 2.0 ft 0 in 1.0 ft 0 in Drapes/blinds Exterior 50% INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00036 1205 66.09 124.08 0.1263 7.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 383 ft2 383 ft2 64 ft 8 ft 1 MASS # Mass Type Area Thickness Furniture Fraction Space _ 1 Default(8 lbs/sq.ft.) 0 ft2 O ft 0.30 BEDROOM 3 -2 Default(8 lbs/sq.ft.) 0 ft2 0 ft 0.30 KITCHEN _ 3 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 pnty _ 4 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 BATH _ 5 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 Laundry _ 6 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 BATH 1 _ 7 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 Master Bed _ 8 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 M CL _ 9 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 BEDROOM 2 _ 10 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 CL 3 _ 11 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 CL 2 _ 12 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 Hall 13 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 LIVING ROOM HEATING SYSTEM # System Type Subtype AHRI # Efficiency Capacity --Geothermal HeatPump-- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Strip Heat None COP: 1.00 27.3 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit Split/Single SEER:16.0 27.6 0 0.72 sys#1 1 3/3/2022 3:28:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric None Laundry 0.95 (0.93) 40.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS Duct ---Supply-- - Return Air CFM 25 CFM 25 HVAC # # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 258 ft' Attic 6.0 64 ft' Default Leakage Laundry (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug I] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov I] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 _ Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 _ Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _ Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/3/2022 3:28:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 + wrightsoft, Load Short Form Entire House Webreps LLC RECEIVED FEB 2 5 2022 St. Lucie, county 1880 82nd Are, Vero Beach, n 32966 Phone: (800) 810-3280 Permittin§ Job: LOT 5-6 Notlem Drive, Fort... Date: February4, 2021 By: Josh Putman Plan: LOT 5-6 Notlem Drive Project For. Joseph Gianna, St Lucie Habitat for Humanity 702 South 6th Street, Fort Pierce, FL Phone: (772) 464-1117 FILE COP"Y Email: joseph@stiuciehabitatorg Design Information Htg Clg Infiltration Outside db (°F) 42 90 Method Simplified Inside db ('F) 72 75 C R(ev tNemi-tight Design TD (°F) 30 15 Fi 100 Daily range - M Inside humidity (%) 30 50 Moisture difference (grAb) 3 61 HEATING EQUIPMENT Make Goodman Trade Heat Strip Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflowfactor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 27 °F 920 clmi 0.049 cknBtuh 0.60 in H2O COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Cond GSX160301 F Coil ASPT30C14A AHRI ref 200825240 Efficiency 13.0 EER, Sensible cooling Latent cooling Total cooling Actual airflow Airflowfactor Static pressure Load sensible heat ratio 16 SEER 19872 Btuh 7728 Btuh 27600 Btuh 920 cfrn 0.051 cfm/Btuh 0.60 in H2O 0.73 ROOM NAME Area (ftZ) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) CIgAVF (cfm) BEDROOM 3 131 1669 2965 81 152 KITCHEN 116 2206 2661 108 136 pnty 11 0 0 0 0 BATH 50 73 279 4 14 Laundry 72 1198 1144 58 59 BATH 1 66 644 311 31 16 Master Bed 162 3261 2445 159 125 M CL 25 0 0 0 0 BEDROOM 2 144 3229 2105 158 108 CL 3 15 0 0 0 0 CL 2 16 0 0 0 0 Hall 61 0 0 0 0 1 I\/IAIr_` Dnr%RA A," MCC-7 GnA4 974 oin "IV II 1I I NWWIVI ►LN V V V r V V-ru JL- I V I V Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Wr ight50ft' 2022-Feb-1519:33:18 Right-Suite®Universa1202121.0.08RSU16998 Pagel ACCP....ity PSLIOT 5-6 Notlem Drive Fort PieroeFL_.rup Calc= MJ8 faces: N Entire House 1291 18847 17958 920 920 Other equip loads 122 1707 Equip. @ 1.00 RSM 19665 Latent cooling 7352 TOTAIQ 1)7n4a nnn nnn VVVV LI V IV JLV JLV Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsof , 2022-Feb-1519:33:18 Right -Suite® Universal 202121.0.08 RSU16998 Page 2 XCA ...ity PSLILOT 5-6 Notlem Drive Fort PierceFL rup Calc= MJ8 faces: N Project Summary Job: LOT5.6 Nodern Drive, Fort... Wrightsoft° Entire House ry Date: Josh P anan021 Webreps LLC Plan: LOT 5-6 Notlem Drive 1880 82nd Aoe, Vero Beach, Fl 32966 Phone: (800) 810-3280 Project Information For: Joseph Gianna St Lucie Habitat for Humanity 702 South 6th Street, Fort Pierce, FL Phone: (772) 464-1117 Email: joseph@stiudehabitatorg Notes: LOT 5-6 Notiem Drive, Fort Pierce, FL. Design Information Weather: Fort Pierce, FL, US Winter Design. Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 72 OF Inside db 75 OF Design TD 30 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15602 Btuh Structure 12672 Btuh Duds 3245 Btuh Ducts 5286 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 122 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 18969 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19665 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 5850 Btuh 1500 Central vent (0 cim) Bttuuh Heating Cooling (none) Area (ft2 1291 1291 Equipment latent load 7352 Btuh Volume (ft3) 10326 10326 Air changes/hour 0.31 0.16 Equipment Total Load (Sen+Lat) 27016 Btuh Equiv. AVF (cfm) 53 28 Req. total capacity at 0.72 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Mfg. Trade Heat Strip Trade GOODMAN Model Cond GSX160301 F AHRI ref Coil ASPT30C14A AHRI ref 200825240 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating Input 8.0 kW Sensible cooling 19872 Btuh Heating output 27297 Btuh Latentcooling 7728 Btuh Temperature rise 27 OF Total cooling 27600 Btuh Actual airflow 920 cfm Actual airflow 920 cfirl Airflowfactor 0.049 cf-nBtuh Airflowfactor 0.051 cfmBtuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.73 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ..-Ightsoft- 2022-Feb-1519:33:18 ,.1 Right -Suite® Universal 2021 21.0.08 RSU16998 Page 1 ACCA ...ity PSLILOT 5-6 Notlem Drive Fort PierceFL_.rup Calc= W8 faces: N MAIN FLOOR N BEDROOM 2 10x6 M CL 159 cfm Master Bed 20 0 10" 12x12 . 10x6 158 cfm 12x 12 10' 912x12L3 7" CL2 8x4 BATH 1 31 cfrn 4" 10x6 152 cirn 1 7" 8x4 59 cfm 4 12 BEDROOM 3 16" 4" 20 x 20 x 920 cfm 14 cfrn 8 x 8 107 cfm Laundry 10" pnty KITCHEN 8x8 6" 136 cfrn LIVING ROOM 6" lip 8x8 107 ctrn GARAGE 6" 8x8 107 ch LOT 5-6 Notlem Drive, Fort Pierce, FL. Webreps LLC Scale: 1 : 86 Performed by Josh Putman for: Page 1 Joseph Gianna 1880 82ndAve Right -Suite® Universal 2021 702 South 6th Street E fro Beach, FI 32966 21.0.08 RSU16998 Fort Pierce, FL Phone: (800) 810-3280 2022-Feb-1519:33:44 Phone: (772) 464-1117 Notlem Drive Fort PieroeFL_ rup joseph@stluciehabitatorg wrightsoft° Duct System Summary Job: LOT5.6 Notlem Drive, Fort... Data: February4, 2021 Entire House By: Josh Putman Webreps LLC Plan: LOT 5-6 Notlern Drive 1880 82nd five, Vero Beach, FI 32966 Phone: (800) 810-3280 Project• • For. Joseph Gianna, St Lucie Habitat for Humanity 702 South 6th Street, Fort Pierce, FL Phone: (772) 464-1117 Email: joseph@stluaehabitatorg Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.280 / 0.080 in H2O 0.132 in/100ft 920 dm 273 Supply Branch Detail Table Cooling 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.280 / 0.080 in H2O 0.132 in/100ft 920 cfm Name Design (Btuh) Htg (cfrn) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BXH c 279 4 14, 0.163 4.0 Ox 0 VIFx 16.6 155.0 st2 BlVH 1 h 644 31 16 0.219 4.0 Ox 0 VIFx 8.2 120.0 BEDROOM 2 h 3229 158 108 0.155 7.0 Ox 0 VIFx 21.1 160.0 st2 BEDROOM 3 c 2965 81 152 0.157 7.0 Ox 0 VIFx 18.8 160.0 st2 KITCHEN c 2661 108 136 0.144 6.0 Ox 0 VIFx 29.6 165.0 st1 LMNG ROOM h 2189 107 103 0.141 6.0 Ox 0 VIFx 28.9 170.0 st1 LMNG ROOM -A h 2189 107 103 0.135 6.0 Ox 0 VIFx 33.1 175.0 st1 LMNG ROOM-B h 2189 107 103 0.132 6.0 Ox 0 VIFx 32.7 180.0 st1 Laundry c 1144 58 59 0.287 4.0 Ox0 VIFX 2.5 95.0 Master Bed h 3261 159 125 0.155 7.0 OX O VIFX 20.8 160.0 st2 Trunk Rg Clg Design Veloc Diam H x W Dud Name Type (cfm) (crm) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 428 446 0.132 818 10.0 0 x 0 VinlFlx st2 PeakAVF 402 399 0.155 512 12.0 0 x 0 VinlFlx -*- wr ghtsoft- ,,`t Right -Suite® Universal 202121.0.08 RSU1 6998 ACM ..Jty PSLILOT 5-6 Notlem Drive Fort PierceFL_ rup Calc = MJ8 faces: N 2022-Feb-1519:33:18 Page 1 Name Grille Size (in) Htg (ch) Clg (dm) TEL R Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mal Trunk rb4 Ox 0 920 920 60.5 0.132 659 - 16.0 Ox 0 VIFx wrightsoft- „t Right Suite® Universal 2021 21.0.08 RSU16998 ACCA,..ityPSLILOT5-6NotlemDrive Fort PierceFL .rup Calc=W8 faces: N 2022-Feb-1519:33:18 Page 2 3" VTR 4" TO S.S. SQUAREFOOTAGE SQ. FT. LIVING 1291 S.F. GARAGE 202 S.F. COVERED PORCH 150 S.F. TOTAL: 1643 S.F. VOLUME UNDER AIR 10,328 CU. FT. 3 PLUMBING NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2014 - PLUMBING. 2. DWV PIPING SHALL BE SCHEDULE 40 PVC. 3. WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L COPPER, CPVC, OR PEX. 4. SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND WITHIN BUILDING. 5. HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF R-3 SHALL BE APPLIED TO PIPING LARGER THAN 3/4" NOMINAL DIAMETER, PIPING FROM WATER HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE CONDITIONED SPACE, PIPING FROM THE WATER HEATER TO THE DISTRIBUTION MANIFOLD, PIPING LOCATED UNDER THE FLOOR SLAB, BURIED PIPING, SUPPLY AND RETURN PIPING IN RECIRCULATION SYSTEMS, PIPING WITH RUN LENGTHS GREATER THAN 20 FEET. 6. WATER HEATERS INSTALLED SHALL BE IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION. 2 " O a 2"0 MIN. SCH. 40 PIPE J__'If" 1/2" X 2 3/4" STUD / ANCHOR OR EQUAL DIRECTION > 1/4" STEEL PLATE OF TRAVEL GARAGE FLOOR SLAB / 4" MIN THICKNESS. / 2\ PROTECTIVE BOLLARD A-1.0 SCALE (24 X 36): 3/4" = 1' - 0" INTERIOR DOOR SCHEDULE # SIZE DESCRIPTION REMARKS ❑A 2868 6 - PANEL HOLLOW -CORE © 3068 6 - PANEL STEEL © 4068 4'- 0" X 6'- 8" BI-FOLD EXTERIOR DOOR & WINDOW SCHEDULE M.O. (WIDTH X HT.) (FT -INCHES) MANUFACTURER - SYM. ITEM LOCATION O1 23SH WINDOW KITCHEN 3' - 2" X 3'- 2 7/8" LAWSON O2 25SH WINDOW BEDROOMS 3'- 2" X 5'- 3 1/2" LAWSON O3 35SH WINDOW LIV ROOM 4'- 6" X 5'- 3 1/2" LAWSON 04 2580 SERIES GARAGE DOOR GARAGE 8'- 0" X T - 0" HAAS DOOR THERMA-TRU 3068 OUTSWING DOOR W/ WD. LIVING ROOM 3'- 4" X 6' - 10" THERMA-TRU O FRAME; THSHLD.; PEEP HOLE 4" X 6' - 10' O THERMA-TRU 3068 OUTSWING DOOR WITH WD. DINING ROOM THERMA-TRU FRAME; THSHLD. DESIGN PRESSURES OPENING DESIGN PRESSURES PRODUCT RATED DESIGN PRESSURES POS. NEG. SEE ELEV'S +80.0 -80.0 SEE ELEV'S +80.0 -80.0 SEE ELEV'S +80.0 -80.0 SEE ELEV'S +31.3 -34.9 SEE ELEV'S +67.0 67.0 SEE ELEV'S +67.0 -6�.0 STRUCTURAL NOTES: 1. DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2. SOIL BEARING CAPACITY: 2500 PSF (MIN.). 3. ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4. SLAB/FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1-1/2" SUSPENDED SLABS: 1-1/2". 6. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 9. UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICES. 10. UNLESS OTHERWISE NOTED, ROOF SHEATHING TO BE NAILED WITH 8d RING -SHANK NAILS @ 4" O.C. PERIMETER AND 6" O.C. FIELD. 11. UNLESS OTHERWISE NOTED FOR EXTERIOR WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH 10d OR BETTER NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, OR SCREWED WITH DRYWALL SCREWS 1.5" LONG AND 0.131 DIA. 12. LINTELS SHALL HAVE A MINIMUM 4" BEARING EXCEPT RECESSED LINTELS SHALL HAVE 8" BEARING. 13. PROVIDE #5 CORNER BARS W/30" MIN. LAP SyPLICE, FOR BOND BEAM. 14. STUCCO SOFFIT NOTE: SOFFIT TO BE STUCCO OVER WIRELATH W/ 11 GA. 2" NAILS W/ 3/8" 0 HEAD @ 6" O.C. OVER 3/8" METAL RIB LATH @ 6" O.C. W/ (2 LAYERS OF 15# FELT OVER EACH FRAMING MEMBER. WALL FINISH / INSULATION NOTES: 1. INTERIOR TO BE 1/2" DRYWALL FINISH. 2. ALL INTERIOR GYPSUM BOARD TO BE MIN. 1/2" THICK WITH (13 GA., 1-3/8" LONG, 19164" HEAD; 0.098" DIAMETER, 1-1/4" LONG, ANNULAR -RINGED; 5d COOLER NAIL, 0.086" 0, 1-5/8" LONG, 15/64" HEAD; OR GYPSUM BOARD NAIL, 0.086"0, 1-5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS AND 12" O.C. FOR SCREWS. 3. WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AS BACKERS FOR WA L TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER ARE�S. (PER FRC 702.4.1 & FRC 702.4.2) 4. WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. 5. WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200. 6. ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY WITH SECTION FRC 316. 7. PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1177, C 1178, C 1278, C 1395, C 1396, OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557. 8. INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 4 ENERGY CONSERVATION NOTES: 1. RESIDENCE SHALL'BE IN ACCORDANCE WITH FLORIDA BULDING CODE 2014 ENERGY CONSERVATION RESIDENTIAL. 2. ATTIC ACCESS DOORS OR HATCHES FROM CONDITIONED SPACES TO UNCONDITIONED SPACES SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES, A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS REQUIRED TO BE PROVIDED WHEN LOOSE FILL IS INSTALLED, TO PREVENT LOOSE FILL FROM SPILLING INTO THE LIVING SPACE. 3. THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGH R402.4.4. 4. THE BUILDING SHALL BE TESTED FOR AIR LEAKAGE IN ACCORDANCE WITH R402.4.1.2. 5. WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FT, AND MUST BE TESTED, LISTED, AND LABELED IN ACCORDANCE WITH R402.4.3. 6. CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION R401.3. PRODUCT APPROVAL EXPIRATION NUMBER 17-1212.21 12/27/2021 17-1212.21 12/27/2021 17-1212.21 12/27/2021 FL16660.11 - FL11136-R5 FL11136-R5 I 28' +32.4 ^ +32.4 35.3 2 35.3 �3'-4" 12'-6" 0 , ym ©O x O N io BEDROOM #2 0 10'-6"X10'-0" c MASTER BEDROOM r 12'-6"X11'-4" ;FFA ❑A 40" XL^J / BATHROOM #1 A/C PAD II I1�Y/ 14' - 4" X 13'- 4" L , 00 �i U / AY \- Zt ELEC. LAUNDRY ROOM I PANEL "A" �- OM#2120/240V 1(d 6 4i;�T�xb 10' - 4" 200A MLO OPENING L PAN[A]TRY J A t-/ KITCHEN � 9'-10"X10'-4"' +33.5 36.3 GRANGE' REFRIG. 7ENINC OPENING (EWH \ \ �� BOLLARD IS EE ATTIC DETAIL 2/A- 1.0 ACCESS 11' 00 GARAGE -' 20'- 0" X 18'- 0" ---- ---------------- I I I I I I I I I I I I I I I I I I I I I I I O +29. 321 4 .5 I I 11'-4" (N E01 CLOSET 2'-0"X 4'-10" 15'-10" RECEIVED FEE 2 2i)22 St. Pe .I,% Cfl©nry, CLOSET 2'-0"X4'-10" BEDROOM #3 0 10'- 6" X 10'- 0" DINING DOOM 13'- 8"XI16'-4" (V if) cli LIVING R OM 13'- 8"X1I --8" 17'1 O +32.0 � +31.6 34.8 34.5 I I I I COVERED PORCH 6'-0"X16'-0" I PRE CAST I LINTEL BEAM (TYP ) I I ------------------------ ---------------- 16'-8" 28' 8X16CMU COLUMN 1 \� FLOOR PLAN I\ 7Q-1 0 SCALE: N.T.S. T +32.0 34.8 co 0) v a OF 80 LO PLAUS ' C ' D . WHOLE HOUSE ENGINEERING 4451 St. Lucie Blvd. Suite 201 Fort Pierce, FL 34946 COPYRIGHT 02016 WHOLE HOUSE ENGINEERING DRAWING NOTICE 0 THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS USED FOR GRAPHIC PURPOSES ONLY. SIZE AND LOCATION MAY VARY TO MEET MANUFACTURER'S SPECIFICATIONS. DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER WITH ANY QUESTIONS REGARDING DIMENSIONS. r PROJECT NUMBER: 10178 REVISIONS: DESCRIPTION DATE BY RE FOR PERMIT 02/15/2021 RB - USER CHANGE 02/08/2022 IRS 1 SITE NAME: NOTLEM LOTS 5&6 SITE NUMBER. PARCEL ID: 3403-805-0045-0004/ 3403-805-0046-000-1 SITE ADDRESS: NOTLEM DRIVE FORT PIERCE, FL 34982 SHEET DESCRIPTION: FLOOR PLAN �F1ttI NUIVICStK: A - 100 ATTIC VENTILATION TOTAL FREE VENT ACTUAL ATTIC REQUIRED AREA TOTAL (AREA/300) SQ. FT SQ. IN. SQ. FT. SQ. IN. 1643 236,592 5.48 788.64 ROOF VENTS SOFFIT VENTS REQUIRED REQUIRED (SI/16.0) # OF SQ. FT. SQ. IN. VENTS SQ. FT. SO. IN. LIN. FT. 2.74 394.32 3 2.74 394.32 24.65 ROOF TOP ATTIC VENT: SOFFIT VENT TYPE: 4" 1 SQ. FT.(144 SQ. IN.) /EA. WIDE X 24" LONG @ 4- O.C. ROOF TOP VENTS SOFFIT VENTS REQUIRED = 3 REQUIRED = 13 n 40" X 4( A/C PAI ELEC. PANEL "A" 120/240V 10 200A MLO PROTECTIVI BOLLARD SE! DETAIL 2/A-1.( / 1 \ MECHANICAL PLAN I 1 .0 SCALE: N.T.S. \ c WHOLE HOUSE ENGINEERING 4451 St. Lucie Blvd. Suite 201 Fort Pierce, FL 34946 COPYRIGHT © 2016 WHOLE HOUSE ENGINEERING DRAWING NOTICE THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS USED FOR GRAPHIC PURPOSES ONLY. SIZE AND LOCATION MAY VARY TO MEET MANUFACTURER'S SPECIFICATIONS. DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER WITH ANY QUESTIONS REGARDING DIMENSIONS. PROJECT NUMBER: 10178 REVISIONS: DESCRIPTION DATE BY RE FOR PERMIT 02/15/2021 RB - USER CHANGE 02/08/2022 RB 1 SITE NAME: NOTLEM LOTS 5&6 SITE NUMBER: PARCEL ID: 3403-805-0045-0004/ 3403-805-004.6-000-1 SITE ADDRESS: NOTLEM DRIVE FORT PIERCE, FL 34982 SHEET DESCRIPTION: ECHANICAL PLAN V -1. (3) #2/0 THHN W/ (1) #4 IN 2" CONDUIT FOR O.H. ELECTRICAL SERVICE 200A METER MAIN/DISCONNECT COMBO NOTE: ALL WIRE TO BE COPPER. i M 11 200A PANEL 'A' 200A 10 3W, 120/240V 10 200A METER - Hlu MAIN/DISCONNECT 2 PANEL COMBO ,A, (3) #2/0 THHN W/ (1) #4 IN 2" CONDUIT _ #4 SOLID OR STAND CU. GROUND TO COLD WATER PIPE, FOUNDATION STEEL, & 5/8" X 8' - 0" GALVANIZED GROUND ROD FOUNDATION COLD STEEL WATER PIPE 2 ) ELECTRICAL RISER DIAGRAM O.H. SERVICE 1.0 SCALE: N.T.S. LOAD CAFC U FATI OR C T508 COQU UA AVE FORT PIERCE, FL 3495 1,291 SQ FT 3,873 WATTS (2) SMALL APP CIR. 3,000 WATTS DRYER 5,000 WATTS RANGE (ELECTRIC) 12,000 WATTS LAUNDRY 1,500 WATTS WATER HEATER (ELECTRIC) 4,500 WATTS WP TUB (OPTION) 1,200 WATTS REFRIGERATOR 1,200 WATTS 1RR. PUMP (OPTION) 1,800 WATTS WELL PUMP (OPTION) 2,000 WATTS MISC. 5,000 WATTS 41,073 WATTS SUB TOTAL HOUSE FIRST 10 KW UP 100% 10,000 WATTS REMAINDER @ 40% 12,429 WATTS ABC #1 © 100% 12,000 WATTS 34.429 TOTAL WATTS 143.5TOTAL CONNECTED LOAD USE 200A SERVICE NOTE: ALL WIRE TO BE COPPER. (3) #2/0 THHN W/ (1) #4 IN 2" CONDUIT FROM U.G. ELECTRICAL SERVICE 200A 10 3W, 115/230V FLUSH MOUNTED NEMA-1 (3) #2/0 THHN W/ (1) #4 IN 2" CONDUIT _- _ #4 SOLID OR STAND CU. GROUND TO ------ - --- -� COLD WATER PIPE, FOUNDATION STEEL, & 5/8" X 8' - 0" GALVANIZED GROUND ROD FOUNDATION COLD _ STEEL WATER PIPE 3 ELECTRICAL RISER DIAGRAM U.G. SERVICE SCALE: N.T.S. ELEC. PANEL "A" 120/240V 10 200A MLO ELEC. METER -LOCATION --- DETERMINED BY HABITAT GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH BOTH LOCAL AND NATIONAL ELECTRICAL CODES. 2. ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL PLAN, RISER DIAGRAM, AND LOADS, AND NOTIFY THE GENERAL CONTRACTOR OF ANY ERRORS OR DESCREPANCIES PRIOR TO INSTALLATION. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO MAKE CERTAIN THAT ALL AIR-CONDITIONING POWER AND CONTROL WIRING AND CONDUITS ARE IN THE BID. 4. THE ELECTRICAL CONTRACTOR IS TO ARRANGE FOR TELEPHONE SERVICE AND TELEPHONE WIRING. COORDINATE WITH THE TELEPHONE COMPANY UNLESS OTHERWISE SPECIFIED. 5. ELECTRICAL CONTRACTOR IS TO COORDINATE ALL SERVICE REQUIREMENTS WITH THE POWER COMPANY BEFORE BIDDING TO BE CERTAIN THAT ALL WORK NECESSARY TO MEET POWER COMPANY SPECIFICATIONS IS IN THE BID. 6. THE ELECTRICAL CONTRACTOR IS TO SIZE MOST BRANCH CIRCUITS; A MAXIMUM VOLTAGE DROP OF 3% IS PERMITTED. 7. SMOKE DETECTORS SHALL BE DIRECT WIRED 120V U.L. 217 APPROVED TYPE WITH AUDIBLE ALARM INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND LISTING. CARBON MONOXIDE DETECTOR(S) TO COMPLY W/ UL #2034-96. 8. ALL APPLIANCE / ELECTRICAL EQUIPMENT WILL BE PROTECTED AT NAME PLATE RATING AS PER NEC 110.3 & 110.21. 9. ALL ELECTRICAL CIRCUITS THAT SUPPLY THE FAMILY ROOM, DINING ROOM, LIVING ROOM, STUDY, HALLWAYS, BEDROOMS, CLOSETS, AND FOYER SHALL BE ARC -FAULT PROTECTED. 10. ALL 125 VOLT 15 & 20 AMP RECEPTACLES INSTALLED IN DWELLING UNITS SHALL BE TAMPER RESISTANT AS PER NEC 406.11. 11. INTERSYSTEM BONDING REQUIRED AND SHALL COMPLY WITH SECTION 250.94, 2008 NEC. 12. GARAGE DOOR OPENER TO BE GFI PROTECTED. ° 13. ALL EQUIPMENT INSTALLED OUTSIDE OR EXPOSED TO WEATHER SHALL BE NEMA TYPE 3R. 14. ALL CONDUCTORS ARE TO BE COPPER, TYPE THHN, UNLESS NOTED OTHERWISE. 15. SWITCHES SHALL BE OF STANDARD GRADE OF SILENT TYPE. 16. RECEPTACLES SHALL BE 15A AND 120V OF THE GROUND TYPE. 17. LIGHTING FIXTURES SHALL BE SELECTED BY THE OWNER. 50% OF THE LAMPS SHALL BE HIGH EFFICACY TYPE. 18. ALL DEVICES SHALL BE SMOOTH TYPE, IVORY COLOR, UNLESS OTHERWISE SPECIFIED. 19. ALL 120V 1-PHASE 15A AND 20A BATHROOM, AND EXTERIOR RECEPTACLES SHALL HAVE GROUND FAULT INTERRUPTER (GFI) PROTECTION WITH EXTERIOR RECEPTACLES OF THE WATERPROOF TYPE. ELECTRICAL CONTRACTOR MAY INSTALL INDIVIDUAL (GFI) IN LIEU OF (GFI) BREAKER WITH SEPARATE CIRCUIT. 20. ARC -FAULT CIRCUIT INTERRUPTER PROTECTION: ALL 120V, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED OR DEVICES IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUN ROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN THE NEC 2011 210.12 (A)(1) THROUGH (6) 21. INSTALLATION HEIGHTS ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED: 45" TO CENTER WALL HUNG TELEPHONE. 12" TO CENTER TELEPHONE JACKS. 46" TO CENTER OF LIGHT SWITCHES. 16" TO CENTER OF RECEPTACLES. 46" TO CENTER KITCHEN RECEPTACLES OVER COUNTERS. 42" TO CENTER BATH RECEPTACLES. 12" TO CENTER TELEVISION JACKS. 22. BRANCH CIRCUITS SHALL BE IN THIN WALL CONDUIT OR APPROVED ROMEX. 23. ALL FAN VENTING AND ROOF PENETRATIONS SHALL BE BY MECHANICAL CONTRACTOR. 24. EXHAUST FANS IN BATHROOMS (IF USED) SHALL BE RATE6 AT 1 CFM/SF OF VENTILATED FLOOR AREA. 220V DISC. 1 ELECTRICAL FLOOR PLAN E-1.0 SCALE: N.T.S. ELECTRICAL KEY SYMB. DESCRIPTION SINGLE POLE SWITCH 3 THREE WAY SWITCH PUSH BUTTON SWITCH 0 DUPLEX RECEPTACLE DUPLEX RECEPTACLE - ONE W/ SWITCH 220V OUTLET LIGHT FIXTURE CJ RECESSED LIGHT FIXTURE WALL MOUNT LIGHT FIXTURE PULL CHAIN LIGHT FLOURESCENT LIGHT FIXTURE PLouREscENr FANILT ® COMBQ EXHUAST FAN/LIGHT COMBO 6M COMBO CEILING FAN/LIGHT COMBO DISCONNECT SWITCH SMOKE DETECTOR COMBINATION SMOKE/CARBON MON. DETECTOR GFI GROUND FAULT PROTECTION WP WEATHERPROOF DW DISHWASHER R RANGE B.C. BELOW COUNTER D DRYER FUEL GAS W/ SHUTOFF VALVE N M PLC WHOLE HOUSE ENGINEERING 4451 St. Lucie Blvd. Suite 201 Fort Pierce, FL 34946 COPYRIGHT 02016 WHOLE HOUSE ENGINEERING - DRAWING NOTICE THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS USED FOR GRAPHIC PURPOSES ONLY. SIZE AND LOCATION MAY VARY TO MEET MANUFACTURER'S SPECIFICATIONS. DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER WITH ANY QUESTIONS REGARDING DIMENSIONS. PROJECT NUMBER: 11_ �8 REVISIONS: DESCRIPTION DATE BY RE FOR PERMIT 02/15/2021 RB - USER CHANGE 02/08/2022 RB 1 SITE NAME: NOTLEM LOTS 5&6 SITE NUMBER: PARCEL. ID: 3403-805-0045-0004/ 3403-805-0046-000-1 SITE ADDRESS: NOTLEM DRIVE FORT PIERCE, FL 34982 Emb's TA CRIPTION: L TRICAL PLAN SHEET NUMBER: Eiiiiiiiiiil 0