HomeMy WebLinkAboutEnergy Efficiency CodeI
FOR0405-10 I
FLORIDA ENERGY .EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: . Bums Residence
Builder Name:
Street: Lot 2001 Nettles Island
Permit Office: St. Lucie County
City, State, Zip: Ft. Pierce, FL, -
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (FromPlans)
9. Wall Types (2224.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1760.00 ft2
b. Frame -Wood, Exterior
R=11.0 464.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1636.0 sqft.)
Insulatio( Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=0:0,5a 1636.00 ft2
6. Conditioned floor area above grade (ft2) 1633
b. N/A
R= ft2
c. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(211.5 sqft.) Description Area
a. Sup: Exterior, Ret: RoomslnBlock1, AH: Garage 6 181.4
a. U-Factor. Sgl, U=0.29 211.50 ft2
b. Sup: Attic, Ret: RoomslnBlock2, AH: Attic 6 200
SHGC: SHGC=0.29
b. U-Factor:. N/A ft2
SHGC:
12. Cooling systems
a. Central Unit
kBtu/hr Efficiency
17.0 SEER:16.00
b. Central Unit
18.0 SEER:16.00
c. U-Factor. N/A ft2
SHGC:
d. U-Factor: N/A ft2
13. Heating s,stem
a. Electric rip He t
kBtu/hr Efficiency
40.5 COP:1.00
SHGC:
b I S n ed
18.0 COP:1.00
Area Weighted Average Overhang Depth: 0.887 ft.l
Area Weighted Average SHGC: 0.290
14. Ho t s
a. Ele ric Tankless
Cap: 1 gallons
8. FlborTypes (1633.0 sqft.) Insulation Area i
EF:0.990
a. Slab -On -Grade Edge Insulation R=0.0 1633.00 ft2j
b. Conservation features
b. N/A R= ft�
Heat Recovery Unit
c.'N/A R= ft2
15. Credits
CF, Pstat
Area: 0.130 Total Proposed Modified Loads: 27.46
PASS
Glass/Floor
Total Standard Reference Loads: 34.99
d by
I hereby certify that the plans and ci boVaEne
Review of the plans and
�T�IIE SSA?,
!this calculation are in compliance with the Floy
specifications covered by this
Code.
calculation indicates compliance
r
PREPARED BY: �� ��/ C G S
with the Florida Energy Code.
Before construction is completed
ti rrrr„�."
DATE: Z '3
this building will be inspected for
compliance with Section 553.908
I hereby certify that this buil g, as designe is in compliance
'
Florida Statutes.
1�,
COD v
with the Florida Energy.,C
WE
OWNER/AGENT: -
BUILDING OFFICIAL:
-
DATE: -
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
i
7/1/2013 2:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
I
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 78
The lower the EnergyPerformance Index, the more efficient the home.
Lot 2001 Nettles Island, Ft. Pierce, FL, -
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows** Description
a. U-Factor: Sgl, U=0.29
SHGC: SHGC=0.29
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
New (From Plans)
Single-family
1
2
No
1633
Area
211.50 ft2
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ft2
ft2
ft2
0.887 ft.
0.290
Area
1633.00 ft2
ft2
ft2
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=5.0
1760.00 ft2
b. Frame - Wood, Exterior
R=11.0
464.00 ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
a. Roof Deck (Unvented)
R=0.0
1636.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
11. Ducts
R ft2
a. Sup: Ext iio RoomslnBlockl, AH: Garage
6 181.4
b. Sup:i e : R slnBlock2, AH:
Attic
6 200
12. Cob 1�gsy tems
� C In ral V it
kBtu/hr
17.0
Efficiency
SEER:16.00
'entra I nit
18.0
SEER:16.00
eat,' systems
��'ctric Strip Heat
b. lectric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
Heat Recovery Unit
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final insinection. Otherwise, a new EPL Display Card will be completed
based on installed Code mpliant feat es.
Builder Signature: Date: 3
Address of New Ho % ,tom �o� ���/ City/FL Zip:,eWew,, 4,04
kBtu/hr Efficiency
40.5 COP:1.00
18.0 COP:1.00
Cap: 1 gallons
EF: 0.91
CF, Pstat
0�-TUE STgp�
*
Ir
COD WE v
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support.
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
PROJECT
Title:
Burns Residence
Bedrooms: 2
Address Type: Street Address
Building Type:
FLProp2010
Conditioned Area: 1633
Lot #
Owner.
Total Stories: 2
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street: Lot 2001 Nettles Island
Permit Office:
St, Lucie County
Cross Ventilation:
County: St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip: Ft. Pierce,
Family Type:
Single-family
FL, -
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp Heating Design Daily Temp
V Design
Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL,
Fort Pierce FL ST LUCIE_CO_INTL 2 39 90
70
75 722 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
898 7184
2
Block2
735 5880
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
RoomslnBlock1
898 7184 Yes 1.09981628 1
1 Yes Yes Yes
2
RoomslnBlock2
735 5880 No 0.90018371 1
2 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio RoomslnBlock1 907 ft 0
1633 ft2
_--- 0 0 1
ROOF
/
Roof Gable Roof
Solar
SA Emitt Emift Deck Pitch
V #
Type
Materials Area Area Color
Absor.
Tested Tested Insul. (deg)
1
Hip
Metal 1769 ft2 0 ft2 Medium
0.96
No 0.9 No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0
1633 ft2
N N
I
7/1/2013 2:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
CEILING
I
#
Ceiling Type Space
R-Value
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) RoomslnBlockl
30
898 ft2
0.11
Wood
2
Under Attic (Unvented) RoomslnBlock2
l 30
738 ft2
0.11
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
hype Space R_yalue
Et
In
Ft In
Area
R-value-Fraction-Absor-Gra
°
1 NE
Exterior
Concrete Block - Int InsMoomslnBloc
15
30
8
240 ft2
0 0.75
0
2 S
Exterior
Concrete Block - Int InsBloomsinBloc
i 5
21
8
168 ft2
0 0.75
0
3 E
Exterior
Concrete Block - Int InsGIoomsInBloc
i 5
42
8
336 ft2
0 0.75
0
4 W
Exterior
Concrete Block - Int InsBloomslnBloc
15
38
8
304 ft2
0 0.75
0
5 S
Exterior
Frame - Wood RoomslnBloc
11
16
8
128 ft2
0.23 0.75
0
6 NE
Exterior
Concrete Block - Int InsBIoomsInBloc
5
30
8
240 ft2
0 0.75
0
7 S
Exterior
Concrete Block - Int Ins6l00mSlnBloc
5
21
8
168 ft2
0 0.75
0
8 E
Exterior
Frame - Wood RoomslnBloc
i 11
42
8
336 ft2
0.23 0.75
0
9 W
Exterior
Concrete Block - Int InSBoornsInBloc i 5
38
8
304 ft2
0 0.75
0
DOORS
#
Omt
Door Type Space
Storms U-Value
eightln
Area
Ft
In
In
Ft
1
W
Wood RoomslnBloc
None
0.460000 3
7
21 ft2
2
E
Wood RoomslnBloc
None
0.460000 3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Storms Area
Depth
Separation
Int Shade
Screening
1
E 3
Metal Single (Tinted) . Yes
0.29
0.29
N
60 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
2
E 3
Metal Single (Tinted) Yes
0.29
0.29
N
9 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
3
E 3
Metal Single (Tinted) Yes
0.29
0.29
N
36 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
4
NE 1
Metal Single (Tinted) Yes
0.29
0.29
N
6 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
5
NE 1
Metal Single (Tinted) Yes
0.29
0.29
N
12 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
6
S 2
Metal Single (Tinted) Yes
0.29
0.29
N
15 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
7
S 2
Metal Single (Tinted) Yes
0.29
0.29
N
13.5 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
8
E 3
Metal Single (Tinted) Yes
0.29
0.29
N
9 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
9
W 4
Metal Single (Tinted) Yes
0.29
0.29
N
12 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
10
W 4
Metal Single (Tinted) Yes
0.29
0.29
N
27 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
11
W 4
Metal Single (Tinted) Yes
0.29
0.29
N
12 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
I
7/1/2013 2:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
I
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
382.8 ft2
382.8 ft2
64 ft 8 ft - 1
I
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 BySpaces
2 BySpaces
Proposed SLA
Proposed SLA
0.000360
0.000360
847.96 46.552 87.548 0.3235 7.0821
694.04 38.102 71.657 0.3235 7.0821
HEATING SYSTEM
#
System Type
Subtype
j Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat
Electric Strip Heat
None
None
i COP: 1 40.5 kBtu/hr 1
i COP: 1 18 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit
Central Unit
None
None
SEER: 16 17 kBtu/hr 510 cfm 0.75 1
SEER: 16 18 kBtu/hr 540 cfm 0.75 2
sys#1
sys#2
HOT#ATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric Tankless
Garage
0.9108 1 gal 50 gal 120 deg Heat Recovery Unit
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
#
— Supply —
Location R-Value Area
— Return = Air Percent
Location Area Leakage Type Handler CFM 25 Leakage QN RLF
HVAC #
Heat Cool
1
2
Exterior 6 181.4 ft RoomslnBloc 45.35 ft DSE=0.88 Garage 0.0 cfm 0.00 % 0.00 0.60
Attic 6 200 ft2 RoomslnBloc 118.4 It DSE=0.88 Attic 0.0 cfm 0.00 % 0.00 0.60
1 1
2 2
i
7/1/2013 2:16,PM EnergyGauge® USA+I- FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
I
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Heating f X� Jan
Feb
Mar
Ma
Jun
Jul
Aug
Nov
Dec
rXI
RI
Rj
Apr rxi
May
Jun
Jul
Aug
Sep
rXI Occtt
X� Nov
�X� Dec
Venting [X Jan
Feb
Mar
X
X
X�
X�
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
7/1/2013 2:16 PM EnergyGauge® USA
- FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: Lot 2001 Nettles Island PERMIT #:
Ft. Pierce, FL, -
.MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of.this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
7/1/2013 2:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6