Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeI FOR0405-10 I FLORIDA ENERGY .EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: . Bums Residence Builder Name: Street: Lot 2001 Nettles Island Permit Office: St. Lucie County City, State, Zip: Ft. Pierce, FL, - Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (FromPlans) 9. Wall Types (2224.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1760.00 ft2 b. Frame -Wood, Exterior R=11.0 464.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1636.0 sqft.) Insulatio( Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=0:0,5a 1636.00 ft2 6. Conditioned floor area above grade (ft2) 1633 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(211.5 sqft.) Description Area a. Sup: Exterior, Ret: RoomslnBlock1, AH: Garage 6 181.4 a. U-Factor. Sgl, U=0.29 211.50 ft2 b. Sup: Attic, Ret: RoomslnBlock2, AH: Attic 6 200 SHGC: SHGC=0.29 b. U-Factor:. N/A ft2 SHGC: 12. Cooling systems a. Central Unit kBtu/hr Efficiency 17.0 SEER:16.00 b. Central Unit 18.0 SEER:16.00 c. U-Factor. N/A ft2 SHGC: d. U-Factor: N/A ft2 13. Heating s,stem a. Electric rip He t kBtu/hr Efficiency 40.5 COP:1.00 SHGC: b I S n ed 18.0 COP:1.00 Area Weighted Average Overhang Depth: 0.887 ft.l Area Weighted Average SHGC: 0.290 14. Ho t s a. Ele ric Tankless Cap: 1 gallons 8. FlborTypes (1633.0 sqft.) Insulation Area i EF:0.990 a. Slab -On -Grade Edge Insulation R=0.0 1633.00 ft2j b. Conservation features b. N/A R= ft� Heat Recovery Unit c.'N/A R= ft2 15. Credits CF, Pstat Area: 0.130 Total Proposed Modified Loads: 27.46 PASS Glass/Floor Total Standard Reference Loads: 34.99 d by I hereby certify that the plans and ci boVaEne Review of the plans and �T�IIE SSA?, !this calculation are in compliance with the Floy specifications covered by this Code. calculation indicates compliance r PREPARED BY: �� ��/ C G S with the Florida Energy Code. Before construction is completed ti rrrr„�." DATE: Z '3 this building will be inspected for compliance with Section 553.908 I hereby certify that this buil g, as designe is in compliance ' Florida Statutes. 1�, COD v with the Florida Energy.,C WE OWNER/AGENT: - BUILDING OFFICIAL: - DATE: - DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist i 7/1/2013 2:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 I ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the EnergyPerformance Index, the more efficient the home. Lot 2001 Nettles Island, Ft. Pierce, FL, - 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows** Description a. U-Factor: Sgl, U=0.29 SHGC: SHGC=0.29 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: New (From Plans) Single-family 1 2 No 1633 Area 211.50 ft2 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ft2 ft2 ft2 0.887 ft. 0.290 Area 1633.00 ft2 ft2 ft2 9. Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R=5.0 1760.00 ft2 b. Frame - Wood, Exterior R=11.0 464.00 ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Roof Deck (Unvented) R=0.0 1636.00 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts R ft2 a. Sup: Ext iio RoomslnBlockl, AH: Garage 6 181.4 b. Sup:i e : R slnBlock2, AH: Attic 6 200 12. Cob 1�gsy tems � C In ral V it kBtu/hr 17.0 Efficiency SEER:16.00 'entra I nit 18.0 SEER:16.00 eat,' systems ��'ctric Strip Heat b. lectric Strip Heat 14. Hot water systems a. Electric b. Conservation features Heat Recovery Unit 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final insinection. Otherwise, a new EPL Display Card will be completed based on installed Code mpliant feat es. Builder Signature: Date: 3 Address of New Ho % ,tom �o� ���/ City/FL Zip:,eWew,, 4,04 kBtu/hr Efficiency 40.5 COP:1.00 18.0 COP:1.00 Cap: 1 gallons EF: 0.91 CF, Pstat 0�-TUE STgp� * Ir COD WE v *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support. staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: Burns Residence Bedrooms: 2 Address Type: Street Address Building Type: FLProp2010 Conditioned Area: 1633 Lot # Owner. Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Lot 2001 Nettles Island Permit Office: St, Lucie County Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Ft. Pierce, Family Type: Single-family FL, - New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 898 7184 2 Block2 735 5880 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 RoomslnBlock1 898 7184 Yes 1.09981628 1 1 Yes Yes Yes 2 RoomslnBlock2 735 5880 No 0.90018371 1 2 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio RoomslnBlock1 907 ft 0 1633 ft2 _--- 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emift Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1769 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1633 ft2 N N I 7/1/2013 2:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING I # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Unvented) RoomslnBlockl 30 898 ft2 0.11 Wood 2 Under Attic (Unvented) RoomslnBlock2 l 30 738 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below hype Space R_yalue Et In Ft In Area R-value-Fraction-Absor-Gra ° 1 NE Exterior Concrete Block - Int InsMoomslnBloc 15 30 8 240 ft2 0 0.75 0 2 S Exterior Concrete Block - Int InsBloomsinBloc i 5 21 8 168 ft2 0 0.75 0 3 E Exterior Concrete Block - Int InsGIoomsInBloc i 5 42 8 336 ft2 0 0.75 0 4 W Exterior Concrete Block - Int InsBloomslnBloc 15 38 8 304 ft2 0 0.75 0 5 S Exterior Frame - Wood RoomslnBloc 11 16 8 128 ft2 0.23 0.75 0 6 NE Exterior Concrete Block - Int InsBIoomsInBloc 5 30 8 240 ft2 0 0.75 0 7 S Exterior Concrete Block - Int Ins6l00mSlnBloc 5 21 8 168 ft2 0 0.75 0 8 E Exterior Frame - Wood RoomslnBloc i 11 42 8 336 ft2 0.23 0.75 0 9 W Exterior Concrete Block - Int InSBoornsInBloc i 5 38 8 304 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value eightln Area Ft In In Ft 1 W Wood RoomslnBloc None 0.460000 3 7 21 ft2 2 E Wood RoomslnBloc None 0.460000 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 E 3 Metal Single (Tinted) . Yes 0.29 0.29 N 60 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 2 E 3 Metal Single (Tinted) Yes 0.29 0.29 N 9 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 3 E 3 Metal Single (Tinted) Yes 0.29 0.29 N 36 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 4 NE 1 Metal Single (Tinted) Yes 0.29 0.29 N 6 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 5 NE 1 Metal Single (Tinted) Yes 0.29 0.29 N 12 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 6 S 2 Metal Single (Tinted) Yes 0.29 0.29 N 15 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 7 S 2 Metal Single (Tinted) Yes 0.29 0.29 N 13.5 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 8 E 3 Metal Single (Tinted) Yes 0.29 0.29 N 9 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 9 W 4 Metal Single (Tinted) Yes 0.29 0.29 N 12 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 10 W 4 Metal Single (Tinted) Yes 0.29 0.29 N 27 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 11 W 4 Metal Single (Tinted) Yes 0.29 0.29 N 12 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None I 7/1/2013 2:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft - 1 I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 BySpaces 2 BySpaces Proposed SLA Proposed SLA 0.000360 0.000360 847.96 46.552 87.548 0.3235 7.0821 694.04 38.102 71.657 0.3235 7.0821 HEATING SYSTEM # System Type Subtype j Efficiency Capacity Block Ducts 1 2 Electric Strip Heat Electric Strip Heat None None i COP: 1 40.5 kBtu/hr 1 i COP: 1 18 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit None None SEER: 16 17 kBtu/hr 510 cfm 0.75 1 SEER: 16 18 kBtu/hr 540 cfm 0.75 2 sys#1 sys#2 HOT#ATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.9108 1 gal 50 gal 120 deg Heat Recovery Unit SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # — Supply — Location R-Value Area — Return = Air Percent Location Area Leakage Type Handler CFM 25 Leakage QN RLF HVAC # Heat Cool 1 2 Exterior 6 181.4 ft RoomslnBloc 45.35 ft DSE=0.88 Garage 0.0 cfm 0.00 % 0.00 0.60 Attic 6 200 ft2 RoomslnBloc 118.4 It DSE=0.88 Attic 0.0 cfm 0.00 % 0.00 0.60 1 1 2 2 i 7/1/2013 2:16,PM EnergyGauge® USA+I- FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 I TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heating f X� Jan Feb Mar Ma Jun Jul Aug Nov Dec rXI RI Rj Apr rxi May Jun Jul Aug Sep rXI Occtt X� Nov �X� Dec Venting [X Jan Feb Mar X X X� X� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/1/2013 2:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: Lot 2001 Nettles Island PERMIT #: Ft. Pierce, FL, - .MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of.this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 7/1/2013 2:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6