Loading...
HomeMy WebLinkAboutEvaluation CertificateU.S. EPART'NIENT OF HOMELAND SECURITY WA 110N C ER I I I ICA I t OMB No. 1660-0008 µEDERAL IE'�MERGENCY MANAGEMENT AGENCY NationalRoodln=ranceProgram Important: Read the instructions on pages 1-9. Expiration Date: July 31, 2015 SECTION A - PROPERTY INFORMATION Al. Building Owner's Name HELEN. BURNS A2. Building Street Address (including Apt., Unit, Suite, and/o.t Bldg. No.) or P.O. Route and Box No. 2001 NETTLES BLVD. - City JENSEN BEACH State FL ZIP Code 34957 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 1, NETTLES ISLAND PROJECT SECTION 1 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL A5. Latitude/Longitude: Lat 27*17'08.9" N Long. 80*12'55.6" W Horizontal Datum: ❑ NAD 1927 N NAD 198.3 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number I A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) N/A sq ft a) Square footage of attached garage 378 . sq ft 'b) Number of permanent flood openings in the crawlspace b) Number of permanent flood openings in the attached garage or enclosure(s) within 1.0 foot 'above adjacent grade N/A within 1.0 foot above adjacent grade 2 c) Total net area of flood openings in A8.b " N/A sq in c) Total net area of -flood openings in A9.b 400 sq in d) Engineered flood openings? ❑ Yes ❑ No d) Engineered flood openings? N Yes ❑ No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number I B2. County Name I B3. State I UNINCORP 120285 ST. LUCIE FL B4. Map/Panel Number 85. Suffix B6. FIRM Index Date B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone 12111C 0312 J 02/16/2012 Effective/Revised Date Zones) AO, use base flood depth) 02/16/2012 AE 8.0 1310. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile N FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 N NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System CBRS) area or Otherwise Protected Area (OPA)? ❑Yes No' Designation Date: _ f CBRS ❑ OPA SECTION C.- BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, ARIA, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: 94 77 A04 FL DT Vertical Datum: NAVD 88 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 N NAVD 1988 ❑'Other/Source:-_ Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (ncluding basement, crawlspace, or enclosure floor) 8.0 N feet ❑ meters b) Top of the next higher floor 17.4._. N feet ❑ meters c) Bottom of the lowest horizontal structuralmember (V Zones only) N/A._ ❑ feet ❑ meters d) Attached garage (top of slab) 4.6 ❑ feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 8.1 ❑X feet ❑ meters (Describe type of equipment and location in Comments) N feet ❑ f) Lowest adjacent" (finished) grade next to building (LAG) 4.2 N feet meters ❑ g) Highest adjacent (finished) grade next to building (HAG) 4.5 ❑ feet meters ❑ h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support NIA._ meters SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the info►maSon on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine orimprisonment under 98 U.S. Code, Secfion,9001. N Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a N Check here if attachments. licensed land surveyor? N Yes ❑ No Certifiees Name EARLE R. STARKEY _,,,� License Number 004459 L Title PROFESSIONAL LAND SURVEYOR 501 DECKER AVENUE FEMA Form. 086-0-33 (7/12) AyA'y Name ACCURIGHT LAND SURVEYING INC. STUART 9e C9 `04/01/2014 Telephone 772-286-7694 See reverse side for continuation. 1993-01-01 PLACE SEAL Replaces all previous editions. a Building Photographs See Instructions for Item A6. For Insurance Company Use: Buildina Street Address (includina AM. Unit Suite, and/or Bldq. No.) or P.O. Route and Box No. I Policy Nianber � 2001 NETTLES BLVD, City State ZIP Code' N JENSEN BEACH FLORIDA 34957 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side MeW and "Left side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. FRONT 04/01/2014 SIDE 04/01/2014 Building Photographs Continuation Page guiding Strut Address (Mduding Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 2001 NETTLES BLVD, State ZIP Code JENSEN BEACH _ FLORIDA 34957 ` If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; `Front View' and `Rear Yew% and, if required, 'Right Side View° and "Left Side View." SIDE 04/01/2014 ICC-ES Evaluation Report ESR-2074* www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877)441-8368 www.smartvent.com infoC&smartvent.com EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: FLOODVENTTm MODEL #1540-520,' FLOODVENT"m -STACKING MODEL #1640-5521; SMARTVENTM MODEL #1540-510; SMARTVENTTm STACKING MODEL #1540.611; WOOD WALL FLOOD MODEL #1540-570; WOOD WALL FLOOD OVERHEAD DOOR MODEL #1640.674; FLOODVENTTm OVERHEAD DOOR MODEL #1540-524; SMARTVENTTm OVERHEAD DOOR MODEL #1540-514 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2009 and 2006 International Building Code® (IBC) ■ 2009 and 2006 International Residential Code® (IRC) Properties evaluated: ■ Physical operation ■ Water flow 2.0 USES The Smart Vent® units are automatic foundation flood vents (AFFVs) employed to equalize hydrostatic pressure on nonfire-resistance-rated foundation walls, rolling -type overhead doors and building walls subject -to rising or falling flood waters. The Smart Vent® units are intended for use where flood hazard areas have been established in accordance with IBC Section 1612.3 or IRC Section R3222.1. Certain models also allow natural ventilation in accordance with Section 1203 of the IBC or Section 408.1 of the IRC. 3.0 DESCRIPTION 3.1 General: When subjected to pressure from rising water, the Smart Vent® AFFVs disengage, then pivot open to allow flow in either direction to equalize water level. and hydrostatic Reissued December 1, 2012 This report is subject to renewal February 1, 2015. A Subsidiary of the International Code Council® pressure from one side of the foundation to the other. The AFFV pivoting door is normally held in the closed position by a buoyant release device. When subjected to rising water, the buoyant release device causes the unit to unlatch; allowing the plate to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. Each unit is fabricated from stainless steel. The SmartVENTTm' Stacking Model #1540-511 and FloodVENT'rm Stacking Model #1540-521 units each contain two vertically arranged openings per unit. 3.2 Engineered Opening: The AFFVs comply with the design principle noted in Section 2.6.2.2 of ASCE/SEI 24 for a maximum rate of rise and fall of 5.0 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement , of ASCE/SEI 24, Smart Vent AFFVs must be installed in accordance with Section 4.0. 3.3 Model Sizes: The FloodVENTTM Model #1540-520, SmartVENTTm Model #1540-510, FloodVENTTM Overhead Door Model #1540-524, and SmartVENTT4 Overhead Door Model #1540-514 units measure 153/4 inches wide by 73/4 inches high (400 by 196.9 mm). The Wood Wall Flood Model #1540-570 and Wood Wall Flood Overhead Door Model #1540-574 . units measure 14 inches wide by 83/4 inches high (355.6 by 222.25 mm). The SmartVENTTm Stacking Model #1540-511 and FloodVENTM Stacking Model #1540-521 units measure 16 inches wide by 16 inches high (406.4 by 406.4 mm). 3.4 Ventilation: The SmartVENT® Model #1540-510 and SmartVENT® Overhead Door Model #1540-514 both have screen covers with 1/4-inch-by-1/4-inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENTTm Stacking Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches (65 806 mm2) of net free area to supply natural ventilation. Other AFFVs recognized in this report do not offer natural ventilation. 4.0 INSTALLATION SmartVENT® and FloodVENTTm are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. The mounting straps allow mounting in wood, masonry and *Revised July 2013 ICC-ES Evaluation Reports are not to be. construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as y to arty finding or other matter in this report, or as to any product covered by the report. ,oao� Copyright @ 2013 Page 1 of 2 ESR-2074 i Most Widely Accepted and' ;ruoLed - Page 2 of 2 concrete walls up to 12 inches (305 mm) thick. In order to 6.1 comply with the engineered opening design principle noted in Section 2.6.2.2 of ASCE/SEI 24, the Smart Vent® AFFVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one AFFV for every 200 square feet (18.6 m2) of enclosed area, except' that the SmartVENTTM" Stacking Model #1540-511 and. FloodVENT'rm Stacking Model #1540-521 'must be installed with a minimum of one AFFV ,'for every 400 square feet (37.2 m2) of enclosed area. ■ Below the.base flood elevation. I ■ With the bottom of the AFFV located a maximum of 12 inches (305.4 mm) above grade. 6.0 CONDITIONS OF USE The Smart Vent® AFFVs described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report', subject to the following conditions: 6.2 The Smart Vent® AFFVs must be installed in accordance with this report, the applicable code and the manufacturer's' installation instructions. In the event of a conflict, the instructions in this report govern. The Smart Vent® AFFVs must not be used in the place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Automatic Foundation Flood Vents (AC364), dated October 2007. 7.0 IDENTIFICATION The Smart VENT' models recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products, Inc.), the model number, and the evaluation report number (ESR-2074).