Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
HVAC Load Calculations
y Burns Residence HVAC Load Calculations for Burns Lot 2001 Nettles Island Fort Pierce, Florida I FN"VACHVAC LoADs Prepared By: Residential Energy Calc's Tuesday, July 02, 2013 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac Residential Light Commercial HVAC Loads Ehte Software Development, Inc: Resi il ia C'alc's Burns Residence` 06h'Saint Lucie, FL 34983 _Page 2. -Project Report General Rco'ect Information ,: ' Project Title: Burns Residence Designed By: Paul Robb Project Date: Friday, June 28, 201;3 Client Name: Burns Client Address: Lot 2001 Nettles Island Client City: Fort Pierce, Florida Company Name: Residential Energy Calc's Reference City: Fort Pierce, Florida Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 251 ft. Altitude Factor: 0.999, Elevation Sensible Adj. Factor: 1.000' Elevation Total Adj. Factor: 1.000" Elevation Heating Adj. Factor: 1.000� Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor I Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61 Total Building Supply CFM: 1,144 CFM Per Square ft.: 0.700 Square ft. of Room Area: 1,633 Square ft. Per Ton: 555 Volume (ft3) of Cond. Space: 13,053 Buildin :Loads ,, . � _ Total Heating Required Including Ventilation Air: 28,078 Btuh 28.078 MBH Total Sensible Gain: 26,174 Btuh 74 % Total Latent Gain: 9,114 Btuh 26 % Total Cooling Required Including Ventilation Air: 35,288 Btuh 2.94 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM - Residential &.Light"Commercial HVAC Loads .- Elite Software Development, Inc: �Rhvac Residential Energy Cale Burns Residence ,"`,P'drt,5aint Lucie, FL 34983, . _ Page 3' Miscellaneous :Report - ' System 1 Carrier Or Equivalent - .'' Outdoor Outdoor • Outdoor`, ;;IndoorIndoor:: Grains 'Input Data' D Bulb Wet Bulb . Rel.Hum . Rel.Hum Dry -Bulb Difference Winter,: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 2 Carrier. Or Equivalent .'.',Outdoor Outdoor,, Outdoor Indoor;' Indoor Grains �System !nput Data Dry Bulb Wet Bulb,.,• ReLHum'_ Re1:Hum D Bulb._ Difference': Winter: 42 39.4 80% n/a 70 n/a Summer: 1 90 - 78 59% 50% 75 6.1.09 Duct Sizin `;In uts' Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./l00 ft. 0.1000 in.wg./100 Minimum Velocity:. _ 650 ft./min 450 ft./min Maximum Velocity: goo ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter ! Summer Infiltration Specified: 0.475 AC/hr '0.248 AC/hr 103 CFM 54 CFM Infiltration Actual: 0.264 AC/hr 0.000 AC/hr Above Grade Volume: X 13,053 Cu.ft. X 13,053 Cu.ft. 3,452 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 58 CFM 0 CFM Total Building Ventilation: 90 CFM 90 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp'. Difference) Winter Infiltration Specified: 0.310 AC/hr (30 CFM), Construction: Semi -Tight Summer Infiltration Specified: 0.160 AC/hr (16 CFM), Construction: Semi -Tight ---System 2--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.610 AC/hr (73 CFM), Construction: Average Summer Infiltration Specified:. 0.320 AC/hr (38 CFM), Construction: Average Duct,Load factor Scenarios for System 1 Attic Duct Duch} Surface from j,,",,No, ' T ,,Description. Location,_ :`Ceiling,-. Leakage Insulation" Area [T.]MDD 1 Supply Open Crawl - 0.12 6 198 No 1 Return , Open Crawl - 0.12 6 37 No Duct Load'Fact& Scenarios for System 2 Attic Duct Duct ii Surface : From No. =Type ; ; Description' Location Ceiling ` Leakage Insulation ; Area [T]MDD . 1 Supply Attic 16B 0.12 6 242 No 1 Return Attic 16B 0.12 6 45 No C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM Load Preview Netj ft. Lat Netj Se, Sysj Sysl Sysj Duct Scope Ton rron I Area G JaTin Gain Gain CFM CFM CFM Size 892 892- Duct Latent 1,087' 1,087' CA... \BurnaRaeidencarhS i Tuesday, July 02.2D13.2:4QPyN Elite �Soft*arw Development,, Inc. rp Port Saint Lucie, FL 34983 Duct Size Preview Room or Source Minimum] Maximuml Rough.1 Designi SPI D�ct Duct Htg Cig I Act. Duct Duct Name Velocityl Velocityl Factorl U1001 Lossl Velocity L ength Flow Flow I Flow Size System I Supply Runouts Zone 1 Other Ducts in System 1 Supply Runouts Zone 2 Other Ducts in System 2 Supply Main Trunk Built -In 650 900 0 0.1 592 OxO / System�-��1 ------------- 1� -'- 8G------''-------- ----'-- -' -r ---' ---- - -----'---------- ---- ---- ----- - Cooling552 System-2 HeoUngFkmv 174 ! --- - ---- --'----- ------'------ ''� - --- '----- --- ----- - ----- ---- - - -1 Coolin CA'. \BurnoRaoidenmadh8 ( Tuesday, July O2.2O13.2:4OPM Rhvac Residential& Light COmmeeClal HVAC Loads k Elite Software Deyelopment, Inc:; Buns`Re sa ence Port Sa nit Luc e�gFL 34983 ,..r� , �:, Pace e11 Total Building Summary Loads, ' Component Area �Sen;� at° en Total DescriptionLoss' Gam.; _ _.. _ Gain Gain IA-cb-o: Glazing -Single pane, operable window, clear, 223.5 1,815 0 5,527 5,527 metal frame with break, u-value 0.29, SHGC 0.3 1A-cm-o: Glazing -Single pane, operable window, clear, 23.5 835 0 1,161 1,161 metal frame no break, u-value 1.27, SHGC 0.75 10A-m: Glazing -French door, single pane clear glass, 48 2,244 0 2,706 2,706 metal frame no break, u-value 1.67, SHGC 0.53 11 D: Door -Wood - Solid Core 45 491 0 456 456 13A-5fcs: Wall -Block, board insulation only, R-5 board 1432.4 4,212 0 2,300 2,300 insulation, filled core, siding finish 12C-Osw: Part -Frame, R-13 insulation in 2 x 4 stud 132 180 0 180 180 cavity, no board insulation, siding finish, wood studs 12E-Osw: Wall -Frame, R-19 insulation in 2 x 6 stud j 268.2 510 0 318 318 cavity, no board insulation, siding finish, wood studs 12E-Obw: Wall -Frame, R-19 insulation in 2 x 6 stud I 57 109 0 44 44 cavity, no board insulation, brick finish, wood studs 12B-Osw: Wall -Frame, R-11 insulation in 2 x 4 stud � 160 436 0 376 376 cavity, no board insulation, siding finish, wood studs 16F-30: Roof/Ceiling-Under Attic with Insulation on Attic 898 805 0 431 431 Floor (also use for Knee Walls and Partition j Ceilings), Vented Attic,, No Radiant Barrier, White Tile, Slate or Concrete, White Metal or White Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 119 4,525 0 0 0 insulation below floor, any floor cover, passive, (heavy moist soil 20P-11: Floor -Over open crawl space or garage, Passive, 66 144 0 51 51 _ R-11 blanket insulation, any cover Subtotals for structure: 16,306 0 13,550 13,550 People: I 11 2,200 2,530 4,730 Equipment: 1,200 4,500 5,700 Lighting: 0 0 0 Ductwork: 8,063 1,979 4,470 6,449 Infiltration: Winter CFM: 58, Summer CFM: 0 1,771 0 0 0 Ventilation: Winter CFM: 90, Summer CFM: 90 1,939 3,735 1,039 4,774 AED Excursion: 0 0 85 85 Total Building Load Totals: 28,078 9,114 26,174 35,288 Check Fi ures Total Building Supply CFM: 1,144 CFM Per Square ft.: 0.700 Square ft. of Room Area: 1,633 Square ft. Per Ton: 555 Volume (fP) of Cond. Space: 13,053 :Building Loads il Total Heating Required Including Ventilation Air: 28,078 Btuh 28.078 MBH Total Sensible Gain: 26,174 Btuh 74 % Total Latent Gain: 9,114 Btuh 26 % Total Cooling Required Including Ventilation Air: 35,288 Btuh 2.94 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Burns Residence.rh9 i Tuesday, July 02, 2013, 2:40 PM Rhvac Residential A Light Commercial HVAC Loads Elite Software Development! Inc. Residential Energy Calc's burns Residerice PortSaint�Lucie, FL 34,983-• ,. Pa a 14 [System 1 Carrier Or Equivalent. S0,Mmary_Load8 Component s Y Area Sen Lat7 Sen TotaF Descnptlon, _.-:. Gain,; Gam., ..:Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 78 632 0 1,864 1,864 metal frame with break; u-value 0.29, SHGC 0.3 IA-cm-o: Glazing -Single pane, operable window, clear, 23.5 835 0 1,161 1,161 metal frame no break, u-value 1.27, SHGC 0.75 11 D: Door -Wood - Solid Core 1 45 491 0 456 456 13A-5fcs: Wall -Block, board insulation only, R-5 board 667.9 1,965 0 1,073 1,073 insulation, filled core, siding finish 12C=0sw: Part -Frame, R-13 insulation in 2 x 4 stud 132 180 0 180 180 cavity, no board insulation, siding finish, wood studs 22A-ph: Floor -Slab on grade, No edge insulation, no 119 no 4,525 0 0 0 insulation below floor, any floor cover, passive, moist soil Subtotals for structure: 8,628, 0 4,734 4,734 People: 8 1,600 1,840 3,440 Equipment: 600 3,900 4,500 Lighting: 0 0 0 Ductwork: 4,138 892 1,572 2,464 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 45, Summer CFM: 45 554 1,868 297 2,164 AED Excursion: 0 0 85 85 System 1 Carrier Or Equivalent Load Totals: I 13,320 4,959 12,428 17;387 Check Fi ures "'10 Supply CFM: 552 CFM Per Square ft.: 0.751 Square ft. of Room Area: 735 Square ft. Per Ton: 507 Volume (ft) of Cond. Space: 5,869 ,S stern Loads Total Heating Required Including Ventilation Air: 13,320 13.320 MBH Total Sensible Gain: 128 Btuh Total Latent Gain: 4,959 Btuh 29 % Total Cooling Required Including Ventilation Air: i 17,387 Btuh 1.45 Tons (Based On Sensible + Latent) Notesjp „.:77 Rhvac is an ACCA approved Manual J and Manual D computer,program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use; and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM Rhvac Residential & Light Commercial`HVAC Loads Elite Software Development,ilnc.' Residential'Energy Calcs' , Burns Residence Port Saint"L`ucie, FL 34983 ", Pa a 15 System' 2'Carrier Or Equivalent -Summary Loads Corn onent :z y x F Area, �z s r �� Senszy Lat E Sen Total t Quan� y _ Loss> ain r .1�. �', ain�x<± N� r :. 1A-cb-o: Glazing -Single pane, operable window, clear, 145.5 1,183 0 3,663 3,663 metal frame with break, u-value 0.29, SHGC 0.3 1 OA-m: Glazing -French door, single pane clear glass, 48 2,244 0 2,706 2,706 metal frame no break, u-value 1.67, SHGC 0.53 13A-5fcs: Wall -Block, board insulation only, R-5 board 764.5 2,247 0 1,227 1,227 insulation, filled core, siding finish ! - 12E-Osw: Wall -Frame, R-19 insulation in 2 x 6 stud 268.2 510 0 318 318 cavity, no board insulation, siding finish, wood studs 12E-Obw: Wall -Frame, R-19 insulation in 2 x 6 stud, 57 109 0 44 44 cavity, no board insulation, brick finish, wood studs 12B-Osw: Wall -Frame, R-11 insulation in 2 x 4 stud I 160 436 0 376 376 cavity, no board insulation, siding finish, wood studs 16F-30: Roof/Ceiling-Under Attic with Insulation on Attic 898 805 0 431 431 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White Tile, Slate or Concrete, White Metal or White Membrane, R-30 insulation 20P-11: Floor -Over open crawl space or garage, Passive, 66 144 0 51 51 R-11 blanket insulation, any cover Subtotals for structure: 7,678 0 8,816 - 8,816 People: 3 600 690 1,290 Equipment: 600 600 1,200 Lighting: 0 0 0 Ductwork: 3,924 1,087 2,898 3,985 Infiltration: Winter CFM: 58, Summer CFM: 0 1,771 0 0 0 Ventilation: Winter CFM: 45, Summer CFM: 45 _ 1,3851,868 742 2,610 System 2 Carrier Or Equivalent Load Totals: { 14,758 4,155 13,746 17,901 9 Supply CFM: 592 CFM Per Square ft.: 0.659 Square ft. of Room Area: 898 Square ft. Per Ton: 602 Volume (ft3) of Cond. Space: 7,184 1r Total Heating Required Including Ventilation Air: 14,758 Btuh 14.758 MBH Total Sensible Gain: 13,746 Btuh 77 % Total Latent Gain: 4,155 Btuh 23 % Total Cooling Required Including Ventilation Air: 17,901 Btuh 1.49 Tons (Based On Sensible + Latent) R Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Burns Residence.rh9 1 Tuesday, July 02, 2013, 2:40 PM m Rhvac Residential -A- L.Ight Comercial HVAC Loads Elite Software Development; lnc. Residential Energy Cal's .. - Burns Residence Port Saint Liacie, FL 34983 ,; ,. : _ Pa a 24 S stem 1, Zone 1•. Summary Loa6,•(Avera6e Load Procedure for Rooms) Component a G �Et : s , Area Sen Lat °Sen Total am :� .r Gain 1A-cb-o: Glazing=Single pane, operable window, clear, 78 632 0 1,864 1,864 metal frame with break, u-value 0.29, SHGC 0.3 1A-cm-o: Glazing -Single pane, operable window, clear, 23.5 835 0 1,161 1,161 metal frame no break, u-value 1.27, SHGC 0.75 11 D: Door -Wood - Solid Core 1, 45 491 0 456 456 13A-5fcs: Wall -Block, board insulation only, R-5 board 667.9 1,965 0 1,073 1,073 insulation, filled core, siding finish 12C-Osw: Part -Frame, R-13 insulation in 2 x 4 stud 132 180 0 180 180 cavity, no board insulation, siding finish, wood studs 22A-ph: Floor -Slab on grade, No edge insulation, no 119 4,525 0 0 0 insulation below floor,, any floor cover, passive, heavy moist soil Subtotals for structure: 8,628 0 4,734 4,734 People: 8 1,600 1,840 3,440 Equipment: 600 3,900 4,500 Lighting: 0 0 0 Ductwork: 4,138 0 1,572 1,572 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 System 1, Zone 1 Load Totals: 12,766 2,200 12,131 14,331 •:CheckFi uses ;Y Supply CFM: 552 CFM Per Square ft.: 0.751 Square ft. of Room Area: 735 Square ft. Per Ton: 615 Volume (ft3) of Cond. Space: 5,869 Zone Coads:, Total Heating Required: 12,766 Btuh 12.766 MBH Total Sensible Gain: 12,131 Btuh 85 % Total Latent Gain: 2,200 Btuh 15 % Total Cooling Required: 14,331 Btuh 1.19 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. , All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I Q\ ...\Burns Residence.rh9 j Tuesday, July 02, 2013, 2:40 PM Rhvac - Residential,`8< Light Commercial,HVAC Load , _ Elite Software Development, Inc, Residential Energy Cal c s Bums Residence Port Sainttu616, FL '*6 :System 2, Zone 2- S'ummary Loads -(Average Load Procedure for Rooms) Component Area Sen E� Lat . Sen Total :.(F C c � ?� ,L 6 .. 'Gain 4Loss{ i, Gain- 5 Gain, :.,... _ - 1A-cb-o: Glazing -Single pane, operable window, clear, 145.5 1,183 0 3,663 3,663 metal frame with break, u-value 0.29, SHGC 0.3 10A-m: Glazing-French,door, single pane clear glass, 48 2,244 0 2,706 2,706 metal frame no break, u-value 1.67, SHGC 0.53 13A-5fcs: Wall -Block, board insulation only, R-5 board 764.5 2,247 0 1,227 1,227 insulation, filled core, siding finish 12E-Osw: Wall -Frame, R-19 insulation in 2 x 6 study 268.2 510 0 318 318 cavity, no board insulation, siding finish, wood studs 12E-Obw: Wall -Frame, R-19 insulation in 2 x 6 study 57 109 0 44 44 cavity, no board insulation, brick finish, wood studs 12B-Osw: Wall -Frame,. R-11 insulation in 2 x 4 studi 160 436 0 376 376 cavity, no board insulation, siding finish, wood studs 16F-30: Roof/Ceiling-Under Attic with Insulation on lAttic 898 805 0 431 431 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White Tile, Slate or Concrete, White Metal or White Membrane, R-30 insulation 20P-11: Floor -Over open crawl space or garage, Passive, 66 144 0 51 51 R-11 blanket insulation, any cover Subtotals for structure: 7,678 0 8,816 8,816 People: 3 600 690 1,290 Equipment: 600 600 1,200 Lighting: 0 0 0 Ductwork: 3,924 0 2,898 2,898 Infiltration:_ Winter CFM: 58, Summer CFM: 0 1,771 0 0 0 _ System 2, Zone 2 Load Totals: 13,373 1,200 13,004 _ 14,204 Check.Fi ores ,: ;y Supply CFM: 592 CFM Per Square ft.: 0.659 Square ft. of Room Area: 898 Square ft. Per Ton: 759 Volume (ft3) of Cond. Space: 7,184 4 Zone Loads r x s Total Heating Required: 13,373 Btuh 13.373 MBH Total Sensible Gain: 13,004 Btuh 92 % Total Latent Gain: 1,200 Btuh 8 % Total Cooling Required: 14,204 Btuh 1.18 Tons (Based On Sensible + Latent) `Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i 1 C:\ ...\Burns Residence.rh9 11 1 Tuesday, July 02, 2013, 2:40 PM i Rhvac Residential & Light. Commercial HVAC Loads Elite Software Development, Inc. `J[ .Residenfial Energy Calc's Bums Residence" ,.. Port Saint Lucie, FL 34983•'_ . ,. Page 30' Detailed Room Loads-.Ro6rrm T - i o er.(Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.5 ft. ; System Number: 1 Room Width: 6.0 ft. Zone Number: 1 Area: 73.0 sq.ft. Supply Air: 84 CFM Ceiling Height: 8.0 ft. - Supply Air Changes: 8.7 AC/hr Volume: 580.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 10 CFM Runout Air: 84 CFM Percent of Supply.: 11 % Runout Duct Size: 0 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 8 % Runout Air Velocity:;. 0 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 in.w9./100 ft. Actual Summer Infil.: 0 CFM y item ,,' ,jss . vf F tr .•y�'� Area j.•._ U,;,w fHtgx 4 SenClg 3 Lat, r,Sen`: OFF <7 3;rn�,,.,�� Quaritit �t rt �� .�� �Loss�H� Gain ., , . :Value „r Y , .. #HTM . ; + .. x TM , E ;, ::Gain'= E -Wall-I3A-5fcs 14.5 X 8 68 1 0.105 2.9 200 1.6 0 109 S -Part-15'/150-12C-Osw 4 X 8 32 0.091 1.4 44 1.4 0 44 W -Part-15°/15°-12C-Osw 2.5 X 8 20 0.091 1.4 27 1.4 0 27 E -Door-11 D 3 X 7 21 { 0.390 10.9 229 10.1 0 213 E -GIs-IA-cb-o shgc-0.3 100%S 15 0.290 8.1 122 10.7 0 160 E -GIs-IA-cm-o shgc-0.75 96%S (2) 12 1.270 35.6 426 36.7 0 440 Floor-22A-ph 21 ft..Per. 21 1.358 38.0 799 0.0 0 0 Subtotals for Structure: 1,847 0 993 Infil.: Win.: 0.0, Sum.: 0.0 116 0.000 0 0.000 0 0 Ductwork: 886 239 AED Excursion: 13 Equipment: 0 600 Room Totals: i 2,733 0 1,845 C:\ ...\Burns Residence.rh9 j Tuesday, July 02, 2013, 2:40 PM Rhvac Residential &Light Commercial HVAC Loads; Elite Software Development,,lnc." Residential Energy Calc's _ Bums Residence.. ;.. Port Saint Lucie, FL 34983 . ,, Pa a 31 Detailed Roomloads - Room 2 -Den/Study (Avers e, Load, Procedure)., •l� $.-'. ,r _ tv x2 - F iT y:t 3 .' iG Y" 'f >s r` by J -- .1'K t t d General.-t,��� t. 'F•"++$ _. Calculation Mode: Htg. '& clg. Occurrences: 1 Room Length: 16.6 ft.. System Number: 1 Room Width: 15.0 ft. j Zone Number: 1 Area: 249.0 sq:ft. Supply Air: 145 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.4 AC/hr Volume: 1,992.0 cu;ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 12 CFM Runout Air: 145 CFM Percent of Supply.: 8 % Runout Duct Size: 0 in. Actual Summer Vent.: 12 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 8 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 in.1 /100 ft. Actual Summer Infil.: 0 CFM . .w �»�.' .W )i } .p` " ,^. ¢. .. Areax ,: aD ,:� `Ht ,. �. 9 Semen W , .. CIg g 1pat; Sen � HTM;Loss HTIVI � Gain Gam; ,v,QuantI n,`��'��Ualue, ,., . ,. w }' S -Wall-13A-5fcs 7 X 8 56 0.105 2.9 165 1.6 0 90 E-Wali-13A-5fcs 12 X 8 60, 0.105 2.9 176 1.6 0 96 NE-Wall-13A-5fcs 15 X 8 108 0.105 2.9 318 1.6 0 174 E -GIs-1A-cb-o shgc-0.3 20%S (3) 36 0.290 8.1 291 28.5 0 1,026 NE-GIs-IA-cb-o shgc-0.3 0%S 12 0.290 8.1 97 25.1 0 301 Floor-22Aph 34 ft..Per_ _ 3_4 1.358 38.0 1,293 0.0 0 0 Subtotals for Structure: 2,340 0 1,687 Infil.: Win:: 0.0, Sum.: 0.0 272 0.000 0 0.000 0 0 Ductwork: 1,122 412 AED Excursion: 22 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600 600 Room Totals: I i 3,462 1,000 3,182 C:\ ...\Burns Residence.rh9 j Tuesday, July 02, 2013, 2:40 PM ;Rhvac -.Residential &' Light:Commercial HVAC,Loads j Elite Software Development,' -Inc., Residential Energy Calc's Burns Residence, Poit Saint Lucie, FU` 4983` page 32 Detailed Room' Loads"�- Room 3 - Bedroom 1 (Average Load Procedure General <;. t - Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 13.7 ft. Zone Number: 1 Area: 233.0 sq.ft. Supply Air: 121 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.9 AC/hr Volume: 1,863.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 13 CFM Runout Air: 121 CFM Percent of Supply.: 10 % Runout Duct Size: 0 in. Actual Summer Vent.: 10 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 8 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM i Item M 1 Y Y,'W v J14, ' JK kK a 4 y Are! *F:ft� P.'}Y'-Is ys a z,U,ra s Htg kk,'�en:„ Clg3, t Lat, f en' `..' r rr ,.;, 4 lz t yap!TaTy,.§ .t ,t :eta,"°.:rsf, a fi g l✓a ✓ Y r -.. r t a na't.,: 1tg r f95� $T;0yy +,::r,; ` a'a -«:1i 6"Twrt, CS,Prf Desc`ri tionw, ,.<k u r Quan#i, ...Value.,, HTM p Loss,�aT.,',.;; >�tHTM Gain, .y<s .Gain n a::. N E-Wall-1 3A-5fcs 14.5 X 8 . 101 .,, 0.105 2.9 297 1.6 0 162 W -Wall-13A-5fcs 19.5 X 8 148.51 0.105 2.9 437 1.6 0 239 NE-GIs-1A-cb-o shgc-0.3 0%S 151 0.290 8.1 122 25.1 0 377 W -GIs-1A-cm-o shgc-0,75 55%S 7.5 1.270 35.6 267 60.0 0 450 Floor-22A-ph 34 ft._ Per..._.. _.._... _ 34 _. _..._ �.. - 1.358 -._ ' 38.0- -1,293 . - 0. - ....0 0 - -0 Subtotals for Structure: 2,416 0 1,228 Infil.: Win.: 0.0, Sum.: 0.0 272 0.000 0 0.000 0 0 Ductwork: 1,159 344 AED Excursion: 19 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 0 600 Room Totals: i i 3,575 400 2,650 C:\ ...\Bums Residence.rh9 Tuesday, July 02, 2013, 2:40 PM Rhvac - Residential & Light Commercial HVAC Loads ' Elite Soflware'Development,lnc. iResidential Energy Uds :; ; ,' ; Burns Residence, Port `Saint Lucie, FL;.34983 : , Page 33 Detailed Room Loads`- Room ,4 :- Bath 1 (Average Load Procedure) ' Calculation Mode: Htg. & clg. I Occurrences: 1 Room Length: 9.0 ft. System Number: 1 Room Width: 5.3 ft. Zone Number: 1 Area: 48.0 sq.ft. Supply Air: 74 CFM Ceiling Height: 8.0 'ft. � Supply Air Changes: 11.5 AC/hr Volume: 382.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 j Actual Winter Vent.: 3 CFM Runout Air: 74 CFM Percent of Supply.: 3 % Runout Duct Size: 0 inj Actual Summer Vent.: 6 CFM Runout Air Velocity: 0 ft.{min. Percent of Supply: 8 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 in!wg./100 ft. Actual Summer Infil.: 0 CFM .::, *x '"t h ,+a 1 3 <- ; y .. wk , .ipy' r r>fnk�,Area t N< , a Ht x � ' CI.. � �, a r _.g gtw.r Descrf�ion *���� rQuanti,;;Value{ Lo sgHTIVIr ,HTM?wO . �, .'Gain�Gain' W -Wall-13A-5fcs 5.5 X- 8 401 0.105 2.9 118 1.6 0 64 W -GIs-1A-cm-o shgc-0.75 41 %S 4 1.270 35.6 142 67.8 0 271 Floor-22A-ph 6 ft.. Per. 6, 1.358 38.0 228 0.0 0 0 Subtotals for Structure: 488 0 335 Infil.: Win.: 0.0, Sum.: 0.0 44 0.000 0 0.000 0 0 Ductwork: 234 209 AED Excursion: 11 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 0 600 Room Totals: I 722 400 1,616 C:\ ...\Burns Residence.rh9- I - Tuesday, July 02, 2013, 2:40 PM Rhvac -,Residential & Light Commercial HVAC Loads Elite Software Development, Inc:' Residential E646 Bu ns Reside ."Calc's'" FL 34983 . • , , Page. 34 ;Detailed -Room. Loads 7,,Room.5 - Laundry (Average Load 'Procedure) Calculation Mode: Htg. & clg. Occurrences:" 1 Room Length: 9.0 ft. System Number: 1 Room Width: 6.5 ft. Zone Number: 1 Area: 59.0 sq.ft. Supply Air: 76 CFM Ceiling Height: 8.0 ft.1 Supply Air Changes: 9.8 AC/hr Volume: 468.0 cu.ft. Req. Vent. Clg: 0 CFM Number of.Registers: 1 I Actual Winter Vent.: 2 CFM Runout Air: 76 CFM Percent of Supply.: 3 % Runout Duct Size: 0 in.! Actual Summer Vent.: 6 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 8 % Runout Air Velocity: 0 Umin. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 in.�wg./100 ft. Actual Summer Infil.: 0 CFM Item:$ ,.f� r� ,„ t ti t 4 �r .:,� -Are xD yHtg; :`,;Sen w C,I /:� Lat { Sen ffi„af;. ?<x-E r. S:_.'Lx, !.! o?vb '""k+3, .n,.. I§nx`;2; �D:. i:_±=; X Quaintlty , .F , .Value„ri i"$. HTMn H, ,Doss' `„k�tTlUl �_ `Gain .fGain> W -Wall-13A-5fcs 6.5 X 8 521 0.105 2.9 153 1.6 0 84 Floor-22A-ph 7 ft..Per. 7 1.358 38.0 266 0.0 0 0 Subtotals for Structure: 419 0 84 Infil.: Win.: 0.0, Sum.: 0.0 521 0.000 0 0.000 0 0 Ductwork: 201 217 AED Excursion: 12 People: 200 lat/per, 230 sen/per: 2 � 400 460 Equipment: 0 900 Room Totals: i I i i I I I i I 620 400 1,672 C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM I Rhvac Residential 16Light Commercial HVAC Loads flite8oitware Development, lnc: Residential Energy CaIds w Burns Residence Port Saint Lucie, FL 34983 , i Pa a 35, Detailed Room: Loads-.Room�6.- Sta rwa (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 7.3 ft.! Zone Number: 1 Area: 73.0' sq.ft. Supply Air: 53 CFM Ceiling Height: 8.0 ft. j Supply Air Changes: 5.5 AC/hr Volume: 584.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 1 Actual Winter Vent.: 6 CFM Runout Air: 53 CFM Percent of Supply.: 11 % Runout Duct Size: 0 in Actual Summer Vent.: 4 CFM Runout Air Velocity: 0 ft.0in. Percent of Supply: 8 % Runout Air Velocity: 0 ft. Imin. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 in.wg./l00 ft. Actual Summer Infil.: 0 CFM Item, fiS z �' ' "L <r�v Are, ,. �r ;ff� }sr T 4 s_- �x �. aka x�gt�rHtg <Sen ,a{Ct9�k `°aLattiSen peseription �a.; "tVaJue ' �HTM r. Loss'x �� Galr%2 HT.Mr �ti�� ,.r°.Quantit rff 4.r_ _ ,..: w ;.Gain W -Wall-13A-5fcs 7.3 X 8 34.41 0.105 2.9 101 1.6 0 55 S -Part-15°/15°-12C-0sw 10 X 8 80[ 0.091 1.4 109 1.4 0 109 W-Door-11 D 3 X 8 241 0.390 10:9 262 10.1 0 243 Floor-22A-ph 17 ft..Per. 171 1.358 38.0 646 0.0 0 Subtotals for Structure: 1,118 _0 0 407 Infil.: Win.: 0.0, Sum.: 0.0 58 0.000 0 0.000 0 0 Ductwork: 1 536 151 AED Excursion: 8 Equipment: 0 600 Room Totals: I I I I I C 1,654 _ 0 1,166 C:1..:1Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM I Rhyac Residential & Light Commercial HVAC Loads " Elite Software Development, Inc; ' ,Residential Energy Calei ; Burns Residence Port Saint Lucie, FL 34983 .. Pa a 36. Detailed Room 'Loads -.Room 7- Master Bedroom, ,..(Avers e Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 21.5 ft. System Number: 2 Room Width: 10.0 ft.! Zone Number: 2 Area: 215.0 sqA. Supply Air: 141 CFM Ceiling Height: 8.0 ft. I Supply Air Changes: 4.9 AC/hr Volume: 1,720.0 W.A. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 11 CFM Runout Air: 141 CFM Percent of Supply.: 8 % Runout Duct Size: 0 in: Actual Summer Vent.: 11 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 8 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 14 CFM Actual Loss: 0.000 in wg./l00 ft. I Actual Summer Infil.: 0 CFM 7 Lat°S r Item; Area t U Ht �a Sen ;& Cl/� Sen' fs n: n h •"R i, F3 t , c.: 1, y 9 �` �, } j,`J' <r A Value HTLossin E -Wall-18A-5fcs 9 X 8 42 0.105 2.9 123 1.6 0 67 S -Wall-13A-5fcs 6.5 X 8 43' 0.105 2.9 126 1.6 0 69 E-Wall-13A-5fcs 2 X 8 161 0.105 2.9 47 1.6 0 26 S -Wall-13A-5fcs 13.5 X 8 94.5 , 0.105 2.9 278 1.6 0 152 W -Wall-I3A-5fcs 13 X 8 1041 0.105 2.9 306 1.6 0 167 E -GIs-lA-cb-o shgc-0.3 16%S (2) 301 0.290 8.1 244 29.5 0 884 S -GIs-lA-cb-o shgc-0.3 100%S 13.51 0.290 8.1 110 10.7 0 144 S -GIs-10A-m shgc-0.53 0%S 9 1.670 46.8 421 37.7 0 339 UP-Ceil-16F-30 21.5 X 10 215I 0.032 0.9 193 0.5 0 103 Subtotals for Structure: _ 1,848 0 1,951 Infil.: Win.: 14.0, Sum.: 0.0 352, 1.227 432 0.000 0 0 Ductwork: 1 947 691 People: 200 lat/per, 230 sen/per: 21 400 460 Room Totals: I I i 3,227 400 3,102 C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM - Residential & Light_Commercial HVAC Loads " Elite Software Development, Inc: Residential Energy bales �"'Rhvac Burns Residence` Pbdbaini'Lucle,'FL.34983 Pa a 37" Detailed Room Loads - Room:, 8.-..?Walk 'ln Closet (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 7.0 ft. System Number: 2 Room Width: 6.0 ft.� Zone Number: 2 Area: 42.0 sq.ft. Supply Air: 10 CFM Ceiling Height: 8.0 ft.! Supply Air Changes: 1.7 AC/hr Volume: 336.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 10, CFM Percent of Supply.: 21 % Runout Duct Size: 0 in: Actual Summer Vent.: 1 CFM Runout Air Velocity: 0 fti/min. Percent of Supply: 8 % Runout Air Velocity: 0 6min. Actual Winter Infil.: 4 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM ,, 4Y, .tg ,t �5en , Y* ��9R ,,, Later ,Sen'; �•,,HTM �?x OD scnovon , Y ,.N , .:y< ° Qua•ntlty; , iLoss � Gam:r.r Gam: ; .k.d?: , s,<<. ,.. . , c .Value t ,HTMp . E -Wall-I3A-5fcs 6 X 8 48, 0.105 2.9 141 1.6 0 77 N -Wall-12E-Osw 7 X 8 56 0.068 1.9 107 1.2 0 66 UP-Ceil-16F-30 7 X 6 42 0.032 0.9 38 0.5 0 20 Subtotals for Structure: I 286 0 163 Infil.: Win.:4.1, Sum.: 0.0 104 1.231 128 0.000 0 0 Ductwork: 1 172 47 Room Totals: 1 I I I I i i I 586 0 210 C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM vac - Residential`& Light Commercial HVAC Loads ; Elite Software Development, 'In c. sidential Energy Calc's Ert"SijfitLu'6'ie- Bums Residence FU 34983 t ,` Page 38 F Detailed Room Loads - Room 9 -- ',iFoyer 2 (Average Load Procedure), General , ...EK d )1 ,(> • {-xt.F f A..x 3ni.. t.f'�it 1f � ?x 2.. 1 d Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.9 ft., System Number: 2 Room Width: 5.5 ft., Zone Number: 2 Area: 82.-0 SO. Supply Air: 124 CFM Ceiling Height: 8.0 ft.1 Supply Air Changes: 11.3 AC/hr Volume: 656.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 1 Actual Winter Vent.: 7 CFM Runout Air: 124 CFM Percent of Supply.: 6 % Runout Duct Size: 0 in. Actual Summer Vent.: 9 CFM Runout Air Velocity: 0 ftl/min. Percent of Supply: 8 % Runout Air Velocity: 0 ft]/min. Actual Winter Infil.: 5 CFM Actual Loss: 0.000 in.wg./l00 ft. Actual Summer Infil.: 0 CFM Item Area' `>' r3 r , , w�+� z 1 UHtg Sen Clg{ L 4s?Sen: kFS�...... �.,.-5�. - "�i'yy d +y� '?✓..+"€kQ�i2�ve" at Descn fiony�` t'.a:Quantit"'`_ - p . r.Ualue°.Hl M, �?3Loss _J _, r airt E -Wall-12E-Osw 14.9 X 8 89.2! 0.068 1.9 170 1.2 0 106 E -GIs-1A-cb-o shgc-0.3 41 %S 6 0.290 8.1 49 23.8 0 143 E -GIs-1 OA-m shgc-0.53 0%S (2) 241 1.670 46.8 1,122 76.0 0 1,824 UP-Ceil-16F-30 14.9 X 5.5 81.9 0.032 0.9 0.5 0 39 Subtotals for Structure: I1,414 _73 0 2,112 Infil.: Win.: 4.8, Sum.: 0.0 119 1.225 146 0.000 0 0 Ductwork: 648 606 Room Totals: I i I i i I 1 _ _ 2,208 0 2,718 C:1... \Burns Residence.rh9 I Tuesday, July 02, 2013, 2:40 PM i Rhvac w Residential & Light Commercial HVAC Loads Elite Software Development, Inc. sid Reential Energy Cale s f Burns R esidence Port Saint Lucie, I.Detafled. Room Loads,-, Room 1O j=: Living (Avers e.Load Procedure) s Calculation Mode: Ht . & cl . g g Occurrences: rences: 1 Room Length: .13.0 ft. System Number: 2 Room Width: 12.0 ft: Zone Number: 2 Area: 156.0 sq.ft. Supply Air:. 117 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.6 AC/hr Volume: 1,248.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1, Actual Winter Vent.: 11 CFM Runout Air: 117 CFM Percent of Supply.: 9 Runout Duct Size: 0 in. Actual Summer Vent.: 9 CFM Runout Air Velocity: 0 Admin. Percent of Supply: - 8 % Runout Air Velocity:. 0 ft./min. Actual Winterinfil.: 12 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM Ht x i Sens 4 CI t[D"escription Quantif' ° Value„ $1=1TM^k' LLoss, HTM`k, g -: _, . h ;, �.fi,,; ,t . . - Gain! Gain; S -Wall-12E-Obw 9 X 8 57 0.068 1.9 109 0.8 0 44 E -Wall-13A-5fcs 12 X 8 66 0.105 2.9. 194 1.6 0 106 NE-Wall-13A-5fcs 13 X 8 104 0.105 2.9 306 1.6 0 167 N -Wall-12E-Osw 4 X 8 17 0.068 1.9 32 1.2 0 20 S -GIs-1A-cb-o shgc-0.3 '100%S 15 0.290 8.1 122 10.7 0 160 E -GIs-1A-cb-o shgc-0.3 16%S (2) 30 0.290 8.1 244 29.5 0 884 N -GIs-10A-m shgc-0.53 100%S 15 1.670 46.8 701 36.2 0 543 UP-Ceil-16F-,30 13 X 12 156 0.032 0.9 140 0.5 0 75 Subtotals for Structure: I 1,848 0 1,999 Infil.: Win.: 12.1, Sum.: 0.0 304 1.227 373 0.000 0 0 Ductwork: 922 573 Room Totals: I i I i 3,143 0 2,572 CA ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM I Rhva_c Residential Light Commercial HVAC Loads Elite Software Development, Inc.; Residential Energy Calc's s „ Bums Residence_ Port Saint Lucie, FL 34983 Detailed Room Loads...' -Room 1..j L Kitchen (Average'Load Procedure)', General Calculation Mode: Htg. & clg. i Occurrences: 1 Room Length: 20.0 ft: System Number: 2 Room Width: 12.0 %, - Zone Number: 2 Area: 240.0 sq.ft. Supply Air: 94 CFM Ceiling Height: 8.0 ft! Supply Air Changes: 2.9 AC/hr Volume: 1,920.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 7 CFM Runout Air: 94 CFM Percent of Supply.: 7 % Runout Duct Size: 0 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 0 k/min. Percent of Supply: 8 % Runout Air Velocity: 0 fl:./min. Actual Winter Infil.: 12 CFM Actual Loss: 0.000 iri.wg./100 ft. Actual Summer Infil.: 0 CFM yHtg ,r �� Sens Clg CN Latz k Sen Description:' ,,,.., ..Quanti.. s.� ;Value,;:=3. HTIUI x.Loss¢Gain: NE-Wall-12E-Osw 8 X 8 58 0.068 1.9 110 1.2 0 69 N -Wall-12E-Osw 6 X 8 48 0.068 1.9 91 1.2 0 57 W -Wall-13A-5fcs 23 X 8 172 0.105 2.9 506 1.6 0 276 NE-GIs-1A-cb-o shgc-0.3 0%S 6 0.290 8.1 49 25.2 0 151 W -GIs-1A-cb-o shgc-0.3 20%S 12 0.290 8.1 97 28.5 0 342 UP-C_eil-16F-30 20 X 12 240 0.032 0.9 215 0.5 0 115 Subtotals for Structure: 1,068 0 1,010 Infil.: Win.: 11.8, Sum.: 0.0 296 1.226 363 0.000 0 0 Ductwork: 594 462 Equipment: 600 600 Room Totals: i i i i I _ 2,025 600 2,072 C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM Rhvac Residential & Light Commerc_ ial HVAC Loads, Elite, Software. Development, Inc.; Inc, Residential E=nergy Calc's Burns Poit:Saint Lucie, FL 34983 _ _. = Ra e,41, Detailed Room Loads - Rom' 121,- Powder Room (Average:Load Procedure) General k S , : S 7 sy Calculation Mode: Ht . & c1g. Occurrences: 1 Room Length: 5.0 ft. System Number: 2 Room Width: 5.0 ft] Zone Number: 2 Area: 25.0 sq.ft. Supply Air: 23 CFM Ceiling Height: 8.0 ,fti Supply Air Changes: 6.8 AC/hr Volume: 200.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 1 Actual Winter Vent.: 3 CFM Runout Air: 23 CFM Percent of Supply.: 14 % Runout Duct Size: 0 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 8 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM �Sen. t 'iaTz Sf �� ty �'1 XF X7'C�• 4enJa 4 3 5 d ) e,{y v,jFC f ,+F :�y. +Y' f � Pi t� �� . }'ki95-j,'a S sraVt F. ..� N -Wall-12B-Osw 5 X 8 40 0.097 2.7 109 2.3 0 94 E -Wall-12B-Osw 5 X 8 40 0.097 2.7 109 2.3 0 94 S -Wall-12B-Osw 5 X 8 410 0.097 2.7 109 2.3 0 94 W -Wall-12B-Osw 5 X 8 410 0.097 2.7 109 2.3 0 94 UP-Ceil-1617-30 5 X 5 25 0.032 0.9 22 0:5 0 12 Subtotals for Structure: � 458 0 388 Infil.: Win.: 6.4, Sum.: 0.0 160 1.225 196 0.000 0 0 Ductwork: 272 111 Room Totals: i i 926 0 499 C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM Rhvac - Residential &,Light Commercial Residential Energy ¢ales - HVAC Loads Elite Software Development, Inc. Bums Residence'' Port -Saint Lucie, FL 34983 Pa a 42 Detailed Room Loads - Room 1.3 fl-.Stairway (Average Load Procedure) �.'�`A1'c d ry, iy? 1 r+P'�'rP*`t1 4 C :.p st 1, ., ht,4 #, Kt 4' s w D Fv 1 S,t 7•ts ; -'"q`h... General- � Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 10.0 ft: System Number: 2 Room Width: Area: 6.6 k 66.0 sq.ft. Zone Number: Supply Air: 2 55 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 6.3 AC/hr Volume: 528.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 1 Actual Winter Vent.: 3 CFM Runout Air: 55 CFM Percent of Supply.: 5 % Runout Duct Size: 0 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 8 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.000 in.wg./100 ft: Actual Summer Infil.: 0 CFM 0,-Azen? Descn tion, �� "���,= uanti r alue� HTr.IVI��„ •Gains. W -Wall-13A-5fcs 7.5 X 8 33 0.105 2.9 97 1.6 0 53 W -GIs-1A-cb-o shgc-0.3 13%S 27 0.290 8.1 219 30.1 0 812 UP-Ceil-I6F-30 10 X 6.6 66 0.032 0.9 59 0.5 0 32 Floor-20P-1 16.6 X 10 66 0.078 2.2 144 0.8 0 51 Subtotals for Structure: _ i 519 0 948 Infil.: Win.: 2.4, Sum.: 0.0 60 1.233 74 0.000 0 0 Ductwork: 246 272 Room Totals: 839 0 1,220 C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM �Rhvac -Residential'& Light Commercial HVAC Loads a Elite Software Development, Inc. • Residential Energy C,alc's " Bums Residence Port'Saint,Lucie, FL- 34983 Page 43 Detailed Room Loads - Room 14,j: Master Bath (Average Load Procedure) General... ..• k .:::. ,., .,� ?., '.,te7 .a ...: ..,„.. �-_.,:vt rn� '!:,,'t'16 .. ,^�i:.•, ;�'. 7. =�Tcr. .�:. �:. '{` c�: =4 Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 2 Room Width: 6.0 ft. Zone Number: 2 Area: 72.0 sq.ft. Supply Air: 28 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.9 AC/hr Volume: 576.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 I Actual Winter Vent.: 1 CFM Runout Air: 28 CFM Percent of Supply.: 5 % Runout Duct Size: 0 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 8 % Runout Air Velocity: 0 h./rein. Actual Winter Infil.: 2 CFM Actual Loss: 0.000 jin.wg./l00 ft. Actual Summer Infil.: 0 CFM W -Wall-13A-5fcs 6 X 8 42 0.105 2.9 123 1.6 0 67 W -GIs-IA-cb-o shgc-0.3 41 %S 6 0.290 8.1 49 23.8 0 143 UP-Ceil-16F-30 12 X 6 72 0.032 0.9 65 0.5 0 35 Subtotals for Structure: 237 0 245 Infil.: Win.: 1.9, Sum.: 0.0 .48 1.229 59 0.000 0 0 Ductwork: 123 136 People: 200 lat/per, 230 sen/per: 1 200 230 Room Totals: i I I 419 200 611 C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM - Rhvac - Residential 8� Light Commercial HVAC Loads Elite So_ ftware Development, Inc. Residential Energy Calc's Burns Residence Port Saint Lucie, FL 34983 _ Pa a 48 System I Room Load Summary '. . =Act': �tRoornz" FArea Sens'��}Ht�:�Duct.� Duct Sens:. lit C.I' S: S. '�No`���Name�:,,,�;. n����,��,,�',�`SFx;x:..w+: := Btuh�`�����CF�M�' ,�; Size�Vel=,��r,' . Btuh.� . �B.tuh ��,. CF�M� � i•, _ y" ---Zone 1--- 1 Foyer 73 2,733 I 36 1-0 0 1,845 0 84 84 2 Den/Study 249 3,462 45 1-0 0 3,182 1,000 145 145 3 Bedroom 1 233 3,575 46 1-0 0 2,650 400 121 121 4 Bath 1 48 722 i 9 1-0 0 1,616 400 74 74 5 Laundry 59 620 8 1-0 0 1,672 400 76 76 _ 6 Stairway 73 1,654 22 1-0 0 1,166 0 53 53 Ventilation 5541 297 1,868 _ Duct Latent j 892 System 1 total 735 . 13,3201 166 _ 12,428 4,959 552 ` 552 System 1 Main Trunk Size: _ Ox0 'in. Velocity: O l ft./min Loss per 100 ft.: 0.000 ; in.wg i }....f e iyi - s 'ff� - C:oohng x'; Sensible/yL'at`ent. -:a> Sensible -. " ' -Latent:','; - ;fotal •i k�y"iT�9y .4 Uy��' 'X1C oi�Pv'. " �.Btuh� l Y,'Btuh Net Required: 1.45 71 % / 29% 12,428 4,959 17,387 Actual: 1.50 75% / 25% 13,500 4,500 18,000 rnent-Data, Heating System Cooling System Type: Electric Resistance Standard Air Conditioner Model: 24A6C618A/FV4CNFOO2 FV4CNF002 Indoor Model: 24ABV618A Brand: COMFORT CONTROL COMFORT CONTROL Description: 10 KW 16 SEER 16 SEER Efficiency: 0 0 Comment: 0 Sound: 0 0 Capacity: 18000 18000 Sensible Capacity: n/a 13,500 Btuh Latent Capacity: n/a 4,500 Btuh AHRI Reference No.: n/a 363816 C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM ---cone z--- 7 Master Bedroom 215 3,227 42 1-0 0 - 3,102 400 141 141 8 Walk In Closet 42 586 8 . 1-0 0 210 0 10 10 9 Foyer 2 82 2,208 20 1-0 0 2,718 0 124 124 10 Living 156 3,143 41 1-0 0 2,572 0 117 117 11 Kitchen 240 2,025' 26 1-0 0 2,072 600 94 94 12 Powder Room 25 926 12 1-0 0 499 0 23 23 13 Stairway 66 839 11 1-0 0 1,220 0 55 55 _14 Master Bath 72 419 _ 5 1-0 0 611 200 28 28_ Ventilation 1,385 ! 742 1,868 Duct Latent 1,087 System 2 total 898 14,758 174 13,746 4,155 592 592 System 2 Main Trunk Size: Ox0 in. Velocity: 0 ft./min Loss per 100 ft.: 0.000 'in.wg Coolie S stem Surnma Net Required: 1.49 77% / 23% 13,746 4,155 17,901 Actual: 1.50 75% / 25% 13,500 4,500 18,000 Type: Model: Indoor Model: Brand: Description: Efficiency: Comment: Sound: Capacity: Sensible Capacity: Latent Capacity: AHRI Reference No.: Electric Resistance 24ABC618A/FV4CNF002 COMFORT CONTROL 10 KW 16 SEER 0 0 18000. n/a n/a n/a Cooling System Standard Air Conditioner FV4CNF002 24ABC618A COMFORT CONTROL 16 SEER 0 0 0 18000 13,500 Btuh 4,500 Btuh 363816 C:\ ...\Burns Residence.rh9 Tuesday, July 02, 2013, 2:40 PM