Loading...
HomeMy WebLinkAboutDensity & Water Content Of Soil521 NW Enterprise Drive • Port St. Lucie, Florida 34986 r NO - 0477 (772) 924-3575 • (772) 924-3580 (fax) 1 C 1 1 1 2 IN -PLACE DENSITY A N AGGREGATE BY NUCLEAI Project: Doyle Masonry, Inc. - Various Pr( Address: Various Client: Doyle Masonry, Inc. Permit No: N/A Field Area Tested: Nettles Island, Lot 49 - Found; Soil Description: Gray and brown fine sand' Proctor / LBR ID: P-003 Max Density (P( D WATER CONTENT OF SOIL AND SOIL* . METHODS (SHALLOW DEPTH) - ASTM 6938 ects Project ID: 12-1489.00 Report ID: D-0022 . Date: 3/17/2014 Tech: Daniel Decaro Test Mode: Direct Transmission Lion Pad 108.2 Opt Moisture (%): 11.7% Test Standard: D 1557 Compaction Required (%): 98.0% Probe Depth (in) Elev Wet Density (PCF) Dry Density (PCF) Moist. (% Compaction Location % Results Northeast Area 12 0-1 117.1 108.1 8.3% 99.9% Pass Center Area 12 0-1 117.2 107.9 8.6% 99.7% Pass Southwest Area 12 0-1 117.3 108.5 8.1 % 100.3% Pass Testing Gauge Information: Manufacturer: Troxler Model Density Standard (DS): 2173 Remarks: Depths are below slab arade. lend for elevation: = Proofroll = Springline = Subgrade = Basecourse P = Top of Pipe 1, 2, 3 = 1st, 2nd, 3rd Lift FL = Final Lift BG = Below Grade BOF = Bottom of Footing FG = Finished Grade 3430 S/N: 34784 Moisture Standard (MS): 609 ee ct t�cina 610r�cT 5 �c o s 4930 • P * 31241201A,U .W.Moler,XPf+ OF ° W l En�ineer e GFA FBPE Test report shall not be reproduced, except in full, without the written approval of GFA International State c Environmental • Geotechnical • Construction Materials Testing • Special and Threshold Inspections • Plan Florida's Leading Engineering Source www.teamgfa.com Mill -01-7"1 Florida's Leading Engineering Source i - Geotechnical - Construction Materials Testing - Threshold and Special Inspections - Plan Review & Code Compliance Rr" A rlo *v JWN Construction 1701 SE Carvalho Street Port St. Lucie, Florida 34982 December 4, 2013 RE: Soil Exploration - Proposed Two -Story Residence 65 Nettles Boulevard, St. Lucie County, FL GFA Project # 13-2500.00 GFA International performed soil testing wp two Standard Penetration Test (SPT) borings at the above referenced project. Based on the test results, the soil on which the referenced structure is to rest is capable of sustaining a safe bearing capacity of 2,560 psf. The subsurface exploration activities were performed in accordance with Section 1818.2 of the Florida Building Code (latest addition) and applicable ASTM and AASHTO standards. For detailed information on subsurface conditions encountered, please refer to the logs attached to this letter. We recommend that the bottom of the fo Itings be founded at a depth of at least 12 inches below finish grade. The depth shall be measured from the lowest adjacent grade. We also recommend a minimum footing width of 18 inches for spread footings and 16 inches for monolithic footings, but not less than 8 inches more than the width of the imposed 'wall. This report does not state or imply that the foundation soils at the bearing level will remain in the original condition in which they were found during the subsurface exploration activities. Exposure to the environment may weaken the foundation soils at the bearing level if the foundation excavations remain open for a long period of time, or if thei foundation soils are exposed to rainfall. Consequently, it is recommended that the excavations for the wall and column footings be performed to final grade and footings constructed as soon as possible to minimize potential damage of the bearing soils. GFA estimates that 0 to 1 foot of fill will be required to bring the foundation pad to design grade. It is also recommended that the 3 feet below existing grade, the bottom of all new -footing excavations and slabs, I material, a co o a minimum density of 95% of the odified Proctor (ASTM D-1557), prior to the placement of the concrete for the footings. If compaction cannot be attained due to persistent wetness or the water table near the bottom of the footing excavation, GFA recommends undercutting below bottom of footing and replacement with No. 57 stone for subgrade that cannot be compacted. The rock fill should be compacted and tamped into the excavation and inspected and verified by a representative from GFA, and tested with hand cone penetrometers, probe rods, or density tests. Foundations and any below grade remains of any structures that are within the footprint of the new construction should be removed so as to not affect structures. Analysis of the foundation performance under hurricane conditions or other storm events, including the effects of loss of soil support due to scour or other forces, is not within the scope of this report, and the recommendations are valid only for normal conditions. Sincerely, GFA International, Inc. FBPE CA #4930 Donald W. Moler, P.E. Senior Geotechnical Engineer Florida Registration No. 60675 Craig A. Hampy, E.I. Staff Engineer Attachments: Test Location Plan, Standard Penetration Test (SPT) Borings (2), Notes Related to Test Borings Copies: Client (2) 521 NW Enterprise Drive • Port St. Lucie, Florida 34986 • (772) 924-3575 • (772) 924.3580 (fax) www.teamgfa.com OFFICES THROUGHOUT FLORIDA i