HomeMy WebLinkAboutPlan Review RecordWV/IV
CORRECTION LIST
Code
No. DESCRIPTION Section
I
I
-2-
NOTE: Entries to this Plan Review Record that require a field check or Inspection of the Installation must be coordinated with the Inspection phase (R109) of the project.
BUILDING PLANNING (Chapter 3)
DESIGN CRITERIA [Table R301.2(1)]
Floor live load (Table R301.5) psf
Roof live load (Table R301.6) psf
Ground snow load psf
Basic wind speed mph
Wind exposure category (R301.2.1.4)
High wind design criteria applicable /I
(R301.2.1.1) V
Seismic design category (SDC)
[Figure R301.2(2)]
SDC C&D provisions (R301.2.2)
Weathering
Frost line depth
Termite area
Decay area
Winter design temperature
Ice barrier underlayment req
Flood hazards Ii
FIRE -REST TANT CONSTRUCTION (R302)
Exterior walls (R302.1, Table R302.7)
Townhouse separation (R302.2)
Continuity and structural
independence (R302.2.1,
R302.2.4)
Parapets and consltruction
(R302.2.2, R302.2.3)
ROOM PLANNING REQUIREMENTS (R303 through R305)
Two-family dwelling separation (R302.3)
Dwelling unit penetrations (R302.4)
welling/garage opening/penetration protec-
tion (R302.5)
__k��Dwelling/garage fire separation (R302.6)
_ Under -stair protection (R302.7)
_all and ceiling finishes (R302.9)
Flame spread index (R302.9.1)
_Smoke -developed index
(R302.9.2)
/ �esting (R302.9.3, R302.9.4)
Insulation' (R302.10)
P Flame spread/smoke-developed
'/ (R302.10.1, R302.10.2)
!� Cellulose loose -fill and exposed
attic insulation (R302.10.3,
R302.10.4)
!� Testing (R302.10.5)
blocking (R302.11)
Draftstopping (R302.12)
Combustible insulation clearance (R302.13)
Use
Area
ft2
Width
Average
ceilin t
Minimum
ceilin t
Natural*
light
Natural ventilation*
Living
120
7'-0"
7'-0"
5'4"
8% floor area
4% floor area
Dining
70
T-0"
7'-0"
5'-0"
8% floor area
4% floor area
Kitchen
N.A.
N.A.
7'-0"
5'-0"
8% floor area
4% floor area
Bedroom
70
7'-0"
7'-0" -
5'-0"
8% floor area
4%. floor area
Bathroom
N.A.
N.A
7'-0"
5`-0"
3 square feet
11/2 square feet
* See Sections R303.1 & R303.3 for mechanical ventilation and artificial light
t 6'-8' min. at plumbing fixtures and for non -habitable basements.
v Required heating (R303.8)
SANITATI O (R306 and R307)
Water closet
Lavatory
Tub or shower
itchen area with sink
Sanitary sewer (Chapter 30)
-' Private disposal (Appendix /)
GLAZING 308)
JZ Identification (R308.1)
L-ouvered windows or jalousies (R308.2)
f/ Human impact loads/hazardous locations
J (R308.3, R308.4)
Skylights and sloped glazing (R308.6)
-3-
BUILDING PLANNING (contt'd.)
GARAGES AND CARPORTS (R309)
I/ Floor surface noncombustible;) sloped floor
(R309.1)
Carport: open two sides; noncombustible
floors; sloped floor (R309.2)'.
Automatic garage door opener (R309.4)
EMERGENCY ESCAPE AND RESCUE OPENINGS
(R310)
here required (R310.1)
Areas, height, width, operations (R310.1.1-
R310.1.4)
Window wells (R310.2)
Bars, grilles, covers and screens (R310.4)
_Under decks and porches (R310.5)
MEANS OF EGRESS (R311)
General (R311.1)
Egress door (R311.2)
TT,//Landings at exterior doors (R311.3 -
` / R311.3.3)
�/ Vertical egress (R311.4)
Construction and attachment (R311.5)
Hallways (R311.6)
Stairway width, headroom, walkli i e (R311.7.1
R311.7.3)
I
Stairway treads, risers profiles (R311.7.4 -
/ R311.7.4.3)
!/ Stairway landings and walking surfaces
(R311.7.5, R311.7.6)
ndrails required (R311.7.7)
Handrail height, continuity, grip -size
(R311.7.7.1- R311.7.7.3)
tairway illumination (R303.6, R311.7.8)
/Special stairways (R311.7.9)
V Ramp slope, landings, handrails (R31.1.8)
GUARDS (R312)
_Required for open -sided surfaces, stairs,'
ramps and landings > 30" above
floor/grade (R312.1)
Height - 36' (R312.2)
Opening limitations (R312.3)
AUTOMATIC FIRE SPRINKLER SYSTEMS (R313)
Townhouses (R313.1)
One- and two-family dwellings '(R313.2)
SMOKE ALARMS (R314)
Referenced standards (R314.1, R314.2)
-L� Location and interconnection (R314.3)
_Power source (R314.4)
CARBON MONOXIDE.ALARMS (R315)
New construction (R315.1)
Existing construction (R315.2)
Referenced standard (R315.3)
FOAM PLASTIC (R302.8, R316)
_6,_..,Cabeling (R316.2)
Surface burning, thermal barrier, specific
approval (R316.3 - R316.7)
DECAY AND TERMITE PROTECTION
(R317 and R318)
_ Protection required (Table R301.2(1), R317.1,
R318.1)
Quality mark (R317.2 and R318.1.1)
SITE ADDRESS (R319)
Address numbers (R319.1)
ACCESSIBILITY (R320)
Type B dwelling units applicable (R320.1)
ELEVATORS/PLATFORM LIFTS (R321)
Referenced standards (R321.1 - R321.3)
FLOOD -RESISTANT CONSTRUCTION (R322)
General (R322.1)
Hazard area and requirements (R301.2.4,
309.3, R322.2, R322.3)
Design professional (R322.3.6)
STORM SHELTERS (R323)
General and referenced standard (R323.1)
-4-
FOUNDATIONS (Chapter 4)
MATERIALS (R402) ' Concrete foundation walls (R404.1.2)
Wood foundations (R402.1)
_Concrete, compressive strength (R402.2)
FOOTINGS (R403)
Soil bearing value (R401.4, R403.1)
Footing width (see page 5) 1
Footing edge thickness = 6"
projection = 2" minimum, I
thickness (R403.1.1)
Footings in SDC C or D (R4
and R403.1.6.1)
Depth below (outside) grade =
but below frost line except fc
tested footings.(R403.1.4, R
R403.1.4.2)
Sill plate bolting in concrete/rr
ameter bolts, within 12" but
bolt diameters from corner,
(R403.1.6)
Footings adjacent to slopes (f
Frost protected shallow found
Footings for precast concrete
(R403.4)
TION WALLS (R404 - R406)
Masonry foundation walls
iimum; footing
S footing
.2, R403.1.3
2" minimum;
frost pro-
93.1.4.1 and
onry = t/Z"di-
t less than 7
embedment
3.1.7)
ns (R403.3)
ndation
Wall height, unbalanced backfill,'Inominal
thickness [Tables R404.1.1(1)1-
R404.1.1(4), R404.1.5.11
Reinforcement size and spacing
(Tables R404.1.1(2) - R404.1.11(4)]
Wall height, unbalanced backfill, nominal
thickness (Tables R404.1.2(2) -
R404.1.2(8), R404.1.5.2]
Horizontal and vertical reinforcement size and
spacing (Tables R404.1.2(1) - P404.1.2(8),
R404.1.2.21 R404.1.2.3.7]
Stay -in -place forms (R404.1.2.3.6.1)
SDC C and D provisions (R404.1.2.4,
. R404.1.4)
Height above finished grade (R404.1.6)
Sill plate size (R404.3)
Precast concrete foundation walls (R404.5)
Drains required if habitable or usable spaces
are below grade* (R405)
Soil class (Table R405.1)
Dampproofing if basements are below grade*
(R406.1)
Waterproofing if high water table* (R406.2)
* If uninhabitable, see Under -Floor Space (R408)
COLUMNS (R407)
__Protection from decay or corrosion (R407.1
and R407.2)
Structural requirements (R407.3)
. Anchorage (R407.3)
Wood columns (minimum 4" square) (R407.3)
Steel columns minimum 3" diameter, Sched-
ule 40 pipe) �,R407.3)
TABLE R403.1
■Hamel u■ unnTu ^c f%Aw1f`0CTC ooCf`ACT nR RJ1ACnMPY9nnT1K1r:R finchacta
LOAD -BEARING VALUE OF SOIL s
1,500 2,000 3,000 >_ 4,000
Conventional fighWrame construction
1 -story
12
12
12
12
2-story
15
12
12
12
3-story
23
17
12
12
4-inch brick veneer over light frame or 8-inch hollow concrete masonry
1 -story
12
12
12
12
2-story
21
16
12
12
3-story
32
24
16
12
8-inch solid or f41 routed masonry
1 -story
16
12
12
12
2-story
29.
21
14
12
3-story
42
32
21
16
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa
a. Where minimum footing width is 12 inches, a single wythe of solid or fully grouted 12—inch nominal concrete masonry units is permitted.
-5-
UNDER -FLOOR SPACE (R408)
Ventilation (R408.1 and R408.2)
Unvented crawl space (R408. )
Access (R408.4) i
WOOD JOI TS AND GIRDERS (R502)
(/ Species and grade (R502.1)
Joists — Sleeping areas, LL = I30 psf
able R502.3.1(1)]
Joists — Nonsleeping areas, LL = 40 psf
[Table R502.3.1(2)]
Cantilevered joists [Tables R502.3.3(1) and
R502.3.3(2)]
Girder spans and header spans for exterior
bearing walls [Table R502.5(1)]
Girder spans and header spans for interior
bearing walls (Table R502.5(I )]
Joists under bearing partitions (R502.4)
Bearing (1.5" minimum on woold or metal;�3" on
masonry or concrete) and lapped joists (3 )
(R502.6, R502.6..1)
ateral restraint and bridging (R502.7,
�502.7.1)
Drilling and notching (R502.8)
{���F stening (R502.9)
y Framing of openings (R502.10)
ood trusses (R502.11)
i
Draftstopping (R502.12)
LUMBER FLOOR SHEATHING (R503.1)
_4,tf!':�Allowable span (Table R503.1)
A,"" End joints (R503.1.1)
WOOD STRUCTURAL PANEL SHEATHING (R503.2)
FOUNDATIONS (cont'd.)
Removal of debris (R408.5)
/Finished grade (R408.6)
I/ Flood resistance (R408.7)
FLOORS (Chapter 5)
Grade (R503.2.1)
Thickness (R503.2.1)
Allowable spans [Tables R503.2.1.1(1) and
R503.2.1.1(2)]
Installation [Table 602.3(1)]
PARTICLEBOARD UNDERLAYMENT (R503.3)
Grade (R503.3.1)
Thickness (R503.3.2)
Installation [Table R602.3(1)]
=D-WOOD FLOORS (ON GROUND) (R504)
_ Base course: 4" thick with maximum 3/4'
gravel or 1/2" crushed stone (R504.2.1)
— Moisture barrier: placed over base course
(R504.2.2)
— Materials (R504.3)
FLOOR FRAMING (R505)
— Cold -formed steel; applicability limits; in -line
framing (R505.1)
— Structural framing (R505.2)
— Material (R505.2.1)
— Identification (R505.2.2)
— Corrosion protection (R505.2.3)
— Fastening (R505.2.4)
— Floor construction (R505.3)
CONCRETE FLOORS (ON GROUND) (R506)
Thickness: 31/2" minimum; Concrete strength
�506.1)
Support: prepared subgrade; maximum earth
fill = 8"; maximum sand or gravel fill = 24"
�506.2.1)
Ba nurse: 4" graded with 2" maximum
aggregate (R506.2.2) ,
V r retarder (R506.2.3)
Reinforcement support (R506.2.4)
0
WALL CONSTRUCTION (Chapter 6)
GENERAL (R601)
Design (R601.2)
I
_Component and cladding wind loads
[Table R3012(2)]
Vapor retarders (R601.3)
WOOD CO STRUCTION (R602)
Construction (Figures R602.3(1) and
R602.3(2)J
�tud grade (R602.2)
�terior walls (R602.3)
Stud spacing [R602.3.1, TableIR602.3(5)]
Interior load -bearing walls (R6o2.4)
Interior nonbearing walls: 2 x 3 at 24 o.c.
or 2" x 4" flat at 16" o.c. (R602.5)
/rrilling and notching — studs (R602.6)
✓ illing and notching —top plate (R602.6.1)
v Headers (Tables R502.5(1), R502.5(2),
/ R602.7.2 and Figure R602.71 2]
✓ F' eblocking (R602.8, R302.11)
Cripple walls (R602.9)
Wall bracing, braced wall lines, lengths,
connections, support and joints (R602.10,
R602.10.1, R602.10.3, R602110.6 -
02.10.8)
_ I
Bracing based on wind speed
[Table R602.10.1.2(1)]
Bracing based on SDC [Table R602.10.1.2(2)]
Intermittent bracing methods (R602.10.2,
Table R602.10.2)
Continuous sheathing
(R602.10.4, R602.10.5)
Bracing for SDC C and D (R602.10.1..4.1,
R602.40.1.5, R602.11)
Wall bracing for stone and masonry veneer
(R602.12)
STEEL WALL FRAMING (R603) ,
V'_ eneral (R603.1)
V Structural framing (R603.2)
Material (R603.2.1)
Identification (R603.2.2)
Corrosion protection (R603.2.3)
Fastening (R603.2.4)
Wall construction (R603.3 - R603.5)
Headers (R603.6)
Studs, tracks and structural sheathing
(R603.7 - R603.9)
SHEATHING (R604 and R605)
Wood structural panels (R604)
Particleboard (R605)
MASONRY CONSTRUCTION (R606 - R610)
V General design (R606)
C and D (R606.12)
Unit masonry (R607)
Multiple wythe masonry (R608)
V Grouted masonry (R609)
Glass unit masonry (R610)
EXTERIOR CONCRETE WALL
CONSTRUCTION (R611)
Applicability (R611.2)
Concrete wall systems (R611.3)
Stay -in -place forms (R611.4)
Materials, construction details
(R611.5 - R61 1. 10)
EXTERIOR WINDOWS & DOORS (R612)
.�eneral; window sills; performance; testing
and labeling (R612)
STRUCTURAL INSULATED PANEL WALL
CONSTRUCTION (R613)
Applicability (R613.2)
Materials (R613.3)
Wall panels, construction details JR613.4 -
R613.10)
-7-
INTERIOR WALL COVERING (R702)
Plaster material (R702.2)
/Plaster support (R702.2.3)
i! I/psum board material (R;
Gypsum board support, apl
/ fastening (R702.3.2 - R7
v Ceramic tile (R702.4)
Other finishes (R702.5 and
EXTERIOR WALL COVERING (R703)
_Watdr-resistive barrier (R70
Wood siding (R703.3)
Attachment and minimum
(Table R703.4)
WALL COVERING (Chapter 7)
Wood shakes and shingles (R703.5)
_Exterior plaster (R703.6)
Stone & masonry veneer (R703.7 & Figure
1) R703.7); Steel angle lintels-4' minimum
bearing each end (R703.7.3)
m and Veneer ties: #9 U.S. gage wire or #22 U.S.
gage by 7/e"corrugated metal; 24" o.c.
maximum horizontal spacing; 2.67 square
feet maximum area supported (wind > 30 psf
6) and SDC C or D, maximum area = 2 square
feet) (R703.7.4.1),
Flashing (R703.7.5 and R703.8)
Exterior insulation and finish systems (R703.9)
5s
Fiber cement siding (R703.10)
Vinyl siding (R703.11)
ROOF -CEILING CONSTRUCTION (Chapter 8)
GENERAL (R801) Species
Design (R801.2 and R801.3) Grade
Component and cladding wind loads.[Table Span
R301.2(2)]
Size
ROOF FRAMING (R802)
N Fire -retardant -treated wood (R802.1.3) RAFT S [Tables R802.5.1(1) - R802.5.1(8)]
_
Framing details (R802.3)
Rafter tie (R802.3.1)
Collar ties (4' o.c., in upper third of attic)
(R802.3.1)
Purlins (2" x 4" at 4' o.c. minimum)
(Figure R80Z5.1, R802.5.1)
Bearing (R802.6)
Cutting and notching (R802.7)
Engineered wood products (R802.7.2)
Lateral support and bridging (R802.8)
_Wood
of openings (R802.9)
_Wood trusses (R802.10)
Roof tie -down (R802.11)
CEILING JOISTS [Tables R802.4(1), R802.4(2)]
Without attic storage, LL =10psf
With attic storage LL = 20psf
Spacing
Ground snow load/LL = 20psf
Controlling design (LL or snow)
Ceiling not attached/ceiling attached
Spacing
Species
Grade
Span
Size
Hc/HR; Adjustment factor
ROOF SHEATHING (R803.2)
Ple' Grade
Thickness.
RTW allowable stresses/grading
�411owable spans (Table R503.2.1.1(1)1
Installation (R803.2.3)
M
CHIMNEYS AND FIREPLACES (cont'd.)
i
Changes in dimension (R1003.6) Chimney clearance (R1003.18)
Additional load (R1003.8) Fireblocking (R1003.19)
Termination (R1003.9) Chimney crickets 3.20)
Spark arrestors (R1003.9.1) FACTORY BUI EPLACES (R1004)
Wall thickness; >_ 4" (R1003. �0) Listed and labeled (R1004.1)
Flue lining - material/installatii n (R1003.11 Installation (R1004.2)
and R1003.12)
i FACTORY -BUILT CHIMNEYS (R1005)
Multiple flues (R1003.13)
Flue area (appliance) 03.14) Listed and labeled (R1005.1)
1 Installation (R1005.3 and R1005.4)
Flue area (mas fireplace) (R1003.15)
Inlet (R1 .16) EXTERIOR AIR SUPPLY (R1006)
Inlet
opening (R1003.17) Intake size (R1006.2, R1006.4)
ENERGY EFFICIENCY* (Chapter 11)
Compliance; material and equipment
(N1101.2, N1101.3)
Zcimate zone (Table N1101.2)
I
'See energy conservation plan review record
B uild'ng envelope (N1102)
!/ Mechanical systems (N1103)
ECHANICAL (Chapters 12-23)
Appliance labeling (M130Z M1303)
Appliance access (M1305, M 401)
Appliance installation (1W1307)
Heating and cooling equipment; heating
and cooling load calculatio s (Chapter 14)
Exhaust systems (Chapter 15)
Duct systems (Chapter 16)
Combustion air (Chapter 17)
Application (G2401.1)
General regulations (G2404)
Appliance location (G2406)
Air requirements (G2407)
Installation (G2408)
Chimney and vent location and terminations
(Chapter 10 and Chapter 18)
Special fuel -burning equipment (Chapter 19)
Boilers/water heaters (Chapter 20)
Hydronic piping (Chapter 21)
Special piping and storage systems
(Chapter 22)
Solar systems (Chapter 23)
Penetrations of fire -resistance rated assem-
blies (R302.4, R302.5)
FUEL GAS (Chapter 24)
Clearances (G2409)
Electrical and electrical bonding (G2410,
G2411)
Pipe sizing (G2413)
Piping materials (G2414)
-10-
r
FUEL GAS (cont°d)
Piping installation (G2415 and G2419) Venting (G2426 - G2429)
Piping support (G2418 and G2424) Misc appliances (G2423, G2425, G2430 -
Valves, controls, connections! (G2420, G2421 G2453)
and G2422) 1
PLUMBING (Chapters 25-33)
Water service location and depth (P2603,
P2604)
Sanitary and storm sewer location and depth
(P2603, P2604)
Piping support (Table P2605.11)
Listed plastic materials (P2608)
Plumbing fixtures (Chapter 27)
Water heater size and location (Chapter 28)
Water supply and distribution system design
and calculations (Chapter 29)
Dwelling unit fire sprinkler systems (P2904)
NFPA 13D system (P2904.1)
Sprinkler coverage
(P2904.2.4)
Piping materials (P2904.3)
Flow rates (P2904.4.1,
P2904.4.2)
Water supply capacity
(P2904.5.2)
Pipe sizing (P2904.6)
Drain, waste and vent pipe sizing and riser
diagram (P3004, P3005, Chapter 31)
Sumps and ejectors (P3007)
Backwater valves (P3008)
Fixture traps (P3201)
Temperature rating
(P2904.2.1, P2904.2.2)
Storm drainage (Chapter 33)
Freezing protection
Penetrations of fire -resistance rated assem-
(P2904.2.3)
blies (R302.4, R302.5)
:ELECTRICAL (Chapters
34-43)
Penetrations of fire -resistance rated assem-
Wiring methods (Chapter38)
blies (E3402.2)
Required lighting and receptacle outlets
Listed and labeled materials ,(E3403)
(E3901, E3903)
Service equipment and location (E3405,
Ground -fault and arc -fault circuit -interrupter
E3601, E3606)
protection (E3902)
Service size and load calculations (E3602)
Available fault current (E3606)
System grounding (E3607)
Required branch circuits (E3703)
Feeder requirements and load calculations
(E3704)
Devices and lighting fixtures (Chapter 40)
Appliance installation (Chapter 41)
Swimming pools (Chapter 42)
Class 2 remote -control, signaling and power -lim-
ited circuits (Chapter 43)
MANUFACTURED ROUSING USED AS DWELLINGS (Appendix E)
Provisions adopted (R102.5)
Compliance with Appendix E verified
-11-
RADON! CONTROL MEASURES (Appendix IF)
Provisions adopted (R102.5) Compliance with Appendix F verified
SWIMMING POOLS, SPAS AND HOT TUBS (Appendix G)
Provisions adopted (R102.5) Compliance with Appendix G verified
- I
PATIO COVERS (Appendix H)
Provisions adopted (R102.5) Compliance with Appendix H verified
PRIVATE SEWAGE DISPOSAL (Appendix 1)
Provisions adopted (R102.5)1 Compliance with Appendix I verified
I
EXISTING BUILDINGS AND STRUCTURES (Appendix J)
i
Provisions adopted (R102.5) Compliance with Appendix J verified
I
SOUND TRANSMISSION (Appendix K)
Provisions adopted (R102.5) Compliance with Appendix K verified
HOME DAY CARE R-3 OCCUPANCY (Appendix M)
Provisions adopted (R102.5) Compliance with Appendix M verified
-12-