Loading...
HomeMy WebLinkAboutTruss-s A-1 ROOF TRUSSES A FLORIDA CORPORATION RE: Job 57380 Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 These truss designs rely on lumber values established by others. A-1 Roof Trusses 4451 St Lucie Blvd Site Information: i Fort Pierce, FL 34946 Customer Info: JWN CONSTRUCTION Project Name: PHILLIP MORRIS Lot/Block: - Model: Address: Subdivision: City: County: St. Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: I License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2010/TP12007 ;Design Program: MiTek 20/20 7.4 Wind Code: ASCE 7-10 Wind Speed: 170 MPH Roof Load: 55.0 psf Floor Load: 65.0 psf This package includes 59 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal #I Truss Name Date No. Seal # Truss Name Date 1 A0263517 A01G 12/21/13 13 A0263829 CJ2D 12/21/13 25 A0263541 F04 12/21/13 2 A0263518 A02G 12/21/13 14 A0263530 CJ3 12/21/13 26 A0263542 F05 12/21/13 3 A0263519 A03 12/21/13 15 A0263531 CJ3A 12/21/13 27 A0263543 F06 12/21/13 A0263520 A04 12/21/13 16 A02635132 CA 12/21/13 28 A0263544 F07 12/21/13 5 A0263521 A05 12/21/13 17 A0263533 CAA 12/21/13 29 A0263545 F08 12/21/13 E4 -6-- A0263522 A06 12/21/13 18 A0263534 CJ5 12121/13 30 'A0263546. F09 12/21/13 7. A0263523 A07 12/21/13 19 A02635135 CJ5A 12/21/13 31 A0263547 F10 12/21/13 8 A0263524 A08G 12/21/13 20 A0263636 CJ7 12/21/13 32 A0263548 F11 12/21/13 9 A0263525 CA 12/21/13 21 A0263537 CJCA 12/21/13 33 A0263549 F12 12/21/13 10 A0263526 CJ1A 12/21/13 22 A0263538 F01 12/21/13 34 A0263550 F13 12/21/13 11 A0263527 CJ2 12/21/13 23 A0263539 F02 12/21/13 35 A0263551 F14 12/21/13 12 A0263528 CJ2A 12/21/13 24 A0263540 F03 12/21/13 36 A0263552 F15 12/21/13 The truss drawing(s) referenced have been prepared;by MiTek Industries, Inc. under my direct supervision based on the parameters provided.by A-1 Roof Trusses, Ltd. Truss Design Engineer's Name: Julius Lee My license renewal date for the state of Florida is February 28,2015 NOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI-1 Sec. 2. Page 1 of 2 Julius Lee, PE / Florida Certification Number 34869 1109 Coastal Bay, Boynton Beach, FL 33435 12/21/13 S o EN * ' N 34869 _� �_ STATE OF S�ONA1-1\\\.�. 1109 COASTAL BAY BOYNTON BEACH,FL 33435 r A-'1 ROOF A10 TRUSSES. AFLORIDA CORPORATION RE: Job 57380 No. Seal # Truss Name Date 37 A0263553 F16 12/21/13 38 A0263554 F17G 12/21/13 39 A0263555 F18 12/21/13 40 A0263556 F19 12/21/13 41 A0263557 F20 12/21/13 42 A0263558 FT1 12/21/13 43 A0263559 FTG1 12/21/13 44 A0263560 FTG2 12/21/13 45 A0263561 FTP1 12/21/13 46 A0263562 FTP10 12/21/13 47 A0263563 FTP2 12/21/13 48 A0263564 FTP3 12/21/13 49 A0263565 FTP4 12/21/13 50 A0263566 FTP5 12/21/13 51 A0263567 FTP6 12/21/13 52 A0263568 FTP7 12/21/13 53 A0263569 FTP8 12/21/13 54 A0263570 FTP9 12/21/13 55 A0263571 HJ3 12/21/13 56 A0263572 HJ7 12/21/13 57 A0263573 J2 12/21/13 58 1 A0263574 I J5 12/21/13 59 1 A0263575 I J9 12/21/13 Lumber design values are in accordance with ANSIITPI 1-2007 section 6.3 These truss designs rely on lumber values established by others. Page 2 of 2 Job I russ I russ I ype y 57380 A01G Roof Special Girder 1 1 � Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer _ Run: 7.500 6 Nov 26 2013 Pont: 7.500 a Nov 26 2013 MI IeK Incuslne5 Inc. Sat Dec 21 08:49:43 2013 Page 1 ID:OkilyUUrWFoYXN4BLICLJhy732V-gr7HUbOXXXi tA28}�U?jJKAeD3GC3whOCltdOFXy6p_6 0.0-0 7-4-0 7.4-0 6 0 10 13-4-11 40 0 17-4-11 3 7-14 21.0.9 Scale =1:35.3 0-0.0 7-4-0 LOADING (psf) SPACING 2-0-0 TOLL 30.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BOLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC201 O/TPI2007 LUMBER TOP CHORD 2x6 SP 240OF 2.OE *Except* T2: 2x4 SP M 30 BOT CHORD 2x6 SP 240OF 2.0E WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 5x10 MT20H co Io 7.4-D 6 0 10 13.4-11 a 0 0 17.4-t1 3 7-1a 21-D-9 CSIi. DEFL in (loc) I/defl Ud PLATES GRIP TO 0.68 Vert(LL) 0.49 7-9 >516 360 MT20 244/190 BC 1 0.71 Vert(TL) -0.77 7-9 >330 240 MT20H 187/143 WB 0.96 Horz(TL) 0.14 5 n/a n/a (Matrix-M) Weight:115 Ib FT = O% BRACING TOP CHORD Structural wood sheathing directly applied or 2-3-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-5-4 oc bracing. WEBS 1 Row at midpt 2-7 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 5.2659/0-7-4 (min. 0-2-3), 1=2015/0-11-0 (min.0-1-11) Max Horz 1=-81(LC 9) Max Uplift5=-1643(LC 5), 1=-1265(LC 4) FORCES (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-15=-8347/5312, 15-16 8853/5321, 16-17--8312/5330, 2-17=-8306/5331, 2-18=-6981/4542,18-19— 6925/4528, 3-19= 6804/4466, 3.4.- 7362/4790, 4-5=-7457/4679 BOT CHORD 1-20=-5221/8193, 20.21=-5221/8193, 21-22=-5221/8193, 9-22=-5221/8193, 8-9= 5221 /8193, 8-23=-5221 /8193, 23-24--5221 /8193, 7-24=-5221 /8193, 6-7=-4378f7049, 5-6=-4378/7049 WEBS 2-7=-1529/902, 3-7=-1627/2513, 4-7— 664/674 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plate(s) at joint(s) 3, 5, 2, 9, 7, 4, 6 and 1 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s) 8 checked for a plus or minus 2 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1643 lb uplift at joint 5 and 1265 lb uplift at joint 1. 9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 67 lb down and 76 lb up at 1-11-10, 74lb down and 49 lb up at 2-11-13, 88 lb down and 87 lb up at 5-3-8, 112 lb down and 124 lb up at 7-7-3, and 160 lb down and 160 lb up at 9-10-15, and 580 lb down and 454 lb up at 12-2-10 on top chord, and 33 Ib up at 1-11-10,1 lb down and 31 lb up at 2-11-13, 22 lb down and 33 lb up at 5-3-8, 41 lb down and 34 lb up at 7-7-3, 59 lb down and 35 lb up at 9-10-15, and 231 lb down and 290 lb up at 12-2-10, and 1817 lb down and 1246 lb up at 13-4-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Continued on page 2 Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 o russ russ Type y 57380 A01 G Roof Special Girder 1 1 Job Reference (optional) Al HWr 1 HUSSCS, rOM I VMHUh, 1-L:l4`J46, Myan Spencer nun: /.mu s Nov zb zuij rnni: /.ouu s Nov zo zuia w ieK Incusines, Inc. Sal Uec zl ui1:4y:4J zui j ra e z j ID:Ql ilyUUrWFoYXN4BLICLJhy732V-gr7HUbOXXX7tA28hU?JJKAeD3GC3whOCltdOFXy p_6 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert:1-3=-90, 3-5=-90, 5-12= 20 Concentrated Loads (lb) Vert: 2— 52(F) 9=-41(F) 7=-1 817(F) 1 5=76(F) 16=49(F)17— 3(F) 1 8=-100(F) 1 9=-520(F) 20=14(F) 21=0(F) 22=-22(F) 23=-59(F) 24=116(F) I - Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job russ I was Type y 57380 A02G Roof Special Girder 1 1 Job Reference (optional) Al HUUI- l 1`11.155t.S, t-UN I NItNUt, r-L J4e4b, nyan bpencei nun: iauu s Nov zo zu ia root. aauu s Nov co cu is mi i nR mousmas, inc. ,at uec z i uo:ga:" zu ia 9 ID:QkilyUUrWFoYXN4BLl(�-Jhy732V-11hgix091rAkoBj2iEYsNBQegZOfEdLzXMan.3 p 5 0.0-0 2 4.3.2 4-2-28 5-0-1 P 13.5 15 4D 6 17.E-5 49 B 22-3-12 Scale-1:38.3 I 21.00 12 4x4 = 1.5x4 11 31 = US MT20H= 3x8 = 1.5x4 II US - 3xB 11 j 3x4 = NAILED 0-0-0 E15*14 B� 5.4 13-5.15 LOADING (psi) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud TCLL 30.0 Plates Increase 1.25 TC 0.57 Vert(LL) 0.16 10 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 10.66 Vert(TL) -0.32 8-10 >834 240 BOLL 0.0 ' Rep Stress Incr NO WB 0.49 Horz(TL) 0.08 6 n/a n/a BCDL 10.0 Code FBC2010fTP12007 (Matrix-M) LUMBER TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE 17-6.5 ¢M 22�-12 PLATES GRIP MT20 244/190 MT20H 187/143 Weight: 99 lb FT - 0% BRACING TOP CHORD Structural wood sheathing directly applied or 3-1-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-7-5 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Left: 2x4 SP No.3 Stabilizer Installation guide. .REACTIONS (lb/size) 6=1206/0-7-4 (min. 0-1-8), 1=1338/0-8-0 (min. 0.1-9) Max Horz 1=82(LC 8) Max Uplift6=-503(LC 5). 1=-633(LC 4) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-1— 894/419, 1-2=-2556/1209, 2-3--2866/1343, 3-4— 2153/967, 4-5=-2221/985, 5-6=-2769/1110 BOT CHORD 1 -1 5=-435/836, 1-11=-1114/2360, 10-11--1107/2356, 9-10=-1253/2810, 8-9=-1253/2810, 7-8=-992/2568,6-7=-992/2568 1 WEBS 2-10=-317/481, 3-8=-883/491, 4-8=-230/639, 5-8=-627/382 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; 6=25ft; Cat. II; Exp D; Encl., GCpI-0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL-1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 503 lb uplift at joint 6 and 633 lb uplift at joint 1.. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) "NAILED" indicates 2-12d (0.148"x3.25") toe -nails. For more details refer to MiTek's ST-TOENAIL Detail. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-2=-90, 2-4=-90, 4-6=-90, 12-15=-20 Concentrated Loads (lb) Vert:2=-46(F) 11=-44(F) Julius Lee, P.E. #34869 ,1109 Coastal Bay Boynton Beach, FL 33435 t o russ fruss lype Fly 57380 A03 Roof Speclal 1 1 Job Reference (Options]) A7 Muur I mubb=b, run 1 ri=mum, — Off-C, my— bF1tlflGtll 0 0 D 7-8.111 7.8.11 48 = 2.00 F2 y16:6ZIill WFoI'XN4BLICCI_Jhy732V-11hgix091rAkoBji2iEYsNBICFIgZCfHoLiXMany�p 5 12.4.2 3.7.13 15-11-15 6.3-13 22-3-12 Scale-1:38.3 4x4 = 3 3x6 = 5x8 11 1.5x4 I I 3x4 = 3x8 - 1.50 11 3x6 —_ ao-o 7.8-11 12-4.2 15-11-15 22.3-12 M Io LOADING (psf) SPACING . 2-0-0 CSI I DEFL in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.91 Vert(LL) 0.22 6-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.65 Vert(TL) -0.27 6-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.28 Horz(TL) 0.08 5 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 93 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-1-1 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross WEDGE bracing be installed during truss erection, in accordance with Left: 2x4 SP No.3 Stabilizer Installation guide. REACTIONS (lb/size) 5=1195/0-7-4 (min. 0-1-10), 1=1260/0-8-0 (min.0-1-11) Max Horz 1=92(LC 12) Max Uplift5=-512(LC 9),1=-571(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-873/624, 1-2=-2625/2025, 2-3= 2190/1795, 3-4--2262/1828, 4-5=-2946/2265 BOT CHORD 1-13— 674/858,1-9=-1719/2363, 8-9=-1717/2369, 7'B=-1717/2369, 6-7=-1999/2693, 5-6=-1999/2693 WEBS 2-7=-451/346, 3-7=-482/662, 4-7— 783/692 1 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf;.h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL-1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 512 lb uplift at joint 5 and 571 lb uplift at joints. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I russ I ype 57300 A04 Common 10 �P" 1 Job Reference (Options]) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencei 0-0-0 3x6 = 5x8 I I 6-0-0 Run: 7s00 s NOV zs zoca rnn[: iaoo s Nov zti zvc a mi iex mcus[nes, mc. sac uec zc ue:ay:as ruc rage i ID:OkilyUUrWFoYXN4BLICLJhy732V-mEE2vH1 n3BlbPLl3c0lnPbjXd3tuOJJVCB67KOy6p_4 11-2.4 4x6 = 3x4 = i 3x4 = 3x4 = 0.0.0 7.7.2 7-7.2 7-2.4 14-9.6 R- .n 22-3-12 Scale-1:37.7 3x6 = . 22-3-12 co to LOADING (psi) SPACING 2-0-0 CSI I DEFL in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plates Increase -1.26 TC 0.81 Vert(LL) 0.30 6-8 >880 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.81 Vert(fL) -0.41 6-8 >657 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.33 Horz(TL) 0.08 5 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 92 lb FT - 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-7-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-0-4 cc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross WEDGE bracing be installed during truss erection, in accordance with Left: 2x4 SP No.3 Stabilizer Installation guide. REACTIONS (Ib/size)_ 5=1193/0-7-4 (min. 0-1-10), 1=1262/0.8-0 (min.0-1-11) Max Horz 1=102(LC 12) Max Uplift5=-531(LC 9), 1=-561(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD - 1 -1 =-934/707,1-2= 2807/2214, 2-3=-2529/2022, 3-4=-2699/2152, 4-5=-3044/2386 BOT CHORD 1-12 669/859, 1-8=-1940/2563, 7-8=-1272/1825, 6-7=-1272/1825, 5-6=-2130/2799 WEBS 3-6=-615/846, 4-6=-599/666, 3-8=-443/622, 2-8=-474/557 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat.11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plate(s) at joints) 5, 3, 6, 4, 8, 2, 1 and 1 checked for a plus or minus 0 degree rotation about its center. 4) Plate(s) at joint(s) 7 checked for a plus or minus 5 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 531 lb uplift at joint 5 and 561 lb uplift at joint 1. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. 434869 1109 Coastal Bay Boynton Beach, FL 33435 Job I ruse I russ I ype y y 57380 A05 Common 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: 7.500 a Nov 26 2013 Print: 7.500 s Nov 26 2013 MTek Industries, Inc. Sat Dec 21 DBA9:45 2013 Page 1 ID:QldlyUUrWFoYXN4BLIQ_Jhy732V-mEE2vH1 n38lbPL13cQInPbjVG3wQOkhVCB67KQy6p_4 i D-0-0 s ao �a0 5-2-4 11-2-4 18-3-7 7-1-3 Scale =1:31.2 4x6 = 0.0-0 7.7-2 I 7.7 2 7-2 4 14.9.6 3 61 18-3-7 Plate Offsets (X,Y): [1:0-0-4,1-3-4], [1:0-2-14,0-0-2], [4:Edge,0-1-8]1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1:25 TC 0.96 Vert(LL) 0.13 6-8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.59 Vert(fL) -0.21 6-8 >999 240 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.31 Horz(TL) 0.04 5 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 83 lb FT - 0% LUMBER TOP CHORD 2x4 SP No.2 *Except* T2: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP'No.3 WEDGE Left: 2x4 SP No.3 BRACING TOP CHORD . Structural wood sheathing directly applied or 3-8-14 oc purlins, except end verticals. - BOT CHORD Rigid ceiling directly applied or 4-7-1 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 5=947/0-8-0 (min. 0-1-8),1=1048/0-8-0 (min. 0-1-8) Max Horz1=167(LC 12) Max Uplift5=-403(LC 9), 1=-477(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-736/558, 1-2= 2158/1690, 2-3=-1874/1496, 3-4=-1178/864, 4-5— 1064/843 BOT CHORD 1-9=-635/704, 1-8=-1612/1998, 7-8— 925/1218, 6-7 925/1218 WEBS 3-6=-310/365, 4-6=-505/88613-8=-465/668, 2-8=-490/562 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp D; Encl., GCp)=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and -forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 403 lb uplift at joint 5 and 477 lb uplift at joint 1. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 o russ I russ I ype y 573�AcsI 80 Common 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: 7.500 s Nov 26 2013 Print: 7.50D s Nov 26 2013 MTek Industries, Inc. Sat Dec 21 06:49:46 2013 Page 1 ID:OkilyUUrWFoYXN4BLICLJhy732V-EQoQ7d2PgSOS1 VtGA7G0yoGIKTGh766eRrrgssytip_3 0-0-0 11.2-4 , � 11 15-9-14 Scale-1:26.9 46 = N N 3x8 11 I 5x6 = 0-0-0 1 7-7-2 15.9-14 7-7-2 1 1 B-2-12 Plate Offsets (X Y): [1:0-0-4 Edge] [1:0-2-14 0-0-2] [5:0-3.0,0-3-0] 1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0,62 Vert(LL) -0.12 5-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.58 Vert(TL) -0.32 5-6 >591 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.62 Horz(TL) 0.03 5 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) , Weight: 72 lb FT = 0% LUMBER 1 BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-11-10 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 4-10-0 oc bracing. WEDGE MiTek recommends that Stabilizers and required cross Left: 2x4 SP No.3 bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 5=811/0-8-0 (min. 0-1-8), 1-913/0-8-0. (min. 0-1-8) Max Horz1=206(LC 12) Max Uplift5=-344(LC 8), 1=-416(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) -or less except when shown. TOP CHORD 1-1— 614/480, 1-2=-1779/1398, 2-3=-1474/1175, 4-5 257/274 BOT CHORD 1-7= 620/610, 1-6= 1442/1672, 5-6=-657/787 WEBS 3-5=-938/809, 3-6=-537/766, 2-6=-547/637 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VuIt=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MW FRS (envelope) and C-C Extehor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL-1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 344 lb uplift at joint 5 and 416 lb uplift at joint 1. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ Inuss lype y y 57380 A07 Common I 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer D•0.0 0-0.0 Run:7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 M7ek Industries, Inc. Sat Dec 21 06:49:46 2013 Page 1 ID:QldlyUUrWFoYXN4BLl0_Jhy732V-EQo07d2PgSOS1 VtGA7GOyoGIOTKS7AyeRrrgssybp_3 6-0.0 11-2.4 124-5 t-2.1 44 — Scale: 1/2"=1' 1.5x4 II 3 4 3x8 11 j 3x4 = 7-7-2 12-4-5 LOADING (psf) SPACING 2-0-0 CSI DER in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.61 Vert(LL) 0.05 6-11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.34 Vert(TL) -0.08 6-11 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.37 Horz(fL) -0.02 5 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight: 60 lb FT - 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BOT CHORD WEDGE Left: 2x4 SP No.3 REACTIONS (lb/size) 5=620/0-8-0 (min. 0-1-8),1=724/0-8-0 (min{ 0-1-8) Max Horz 1=260(LC 12) Max Uplift5=-326(LC 8). 1— 314(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-445/344, 1-2=-1192/925, 2-3— 861/667 BOT CHORD 1-7=-605/472, 1-6=-1161/1169 WEBS 3-6=-686/802,2-6=-617f732,3-5= 787/798 Structural wood sheathing directly applied or 5-0-9 oc purlins, except end verticals. Rigid ceiling directly applied or 5-5-13 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-5.Opsf; BCDL=5.0psf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 326 lb uplift at joint 5 and 314 lb uplift at joint 1. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I cuss I ype c1ty ply 57380-, A08G Common Girder 1 2 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: /.00u s NOV ZO Zu1a Vnni: /.ODU s NOV Zb ZU1J MI IeK mcusines Inc. sai uec zi uu:4u:4/ "Lul Ya e 7 ID:OkilyUUrWFoYXN4BLIQ_Jhy732V-IcMoKz32amYJffSjroGU0ps5tVts1Mg`\91E y p_2 0 0 0 4-8-12 8-3-5 11-10-0 15-4-11 18.11.4 24-7-4 4-8-12 3-6.9 3 6 11 3.6 11 3.6 9 5 8 0 1 Scale=1:41.8 6x12 = 2x4 11 3x4 = I 7x10 MT20H= 4x6 11 3x6 11 0-0-0 48 4-8-12 1 3.6.9 8 3 5 I3-6-11 11-10 0 15.4-11 18-11-4 24-7.4 3-6 11 3.6 9 5 Plate Offsets (X,Y): [1:0-0-0,0-2-61, [5:0-1-8,0-1-8],[7:1-8-7,0-3-2],[7:0-10-0,0-0-3],[8:0-4-4,0-1-8],[9:0-3-8,0-1-12],[10:0-5-0,0-4-8] LOADING (psf) SPACING 2-0-0 I CSI DEFL in (loc) I/dell L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.87 Vert(LL) 0.67 , 9-10 >442 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 10.97 Vert(TL) -0.84 9-10 >350 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr NO WB J 0.67 Horz(TL) 0.17 7 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 273 lb FT = 0% LUMBER TOP CHORD 2x4 SP M 30'Except' T2: 2x4 SP M 31 BOT CHORD 2x6 SP 2400F 2.0E 'Except' B2: 2x6 SP M 26 WEBS 2x4 SP No.3 *Except* W5: 2x4 SP No.2 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING TOP CHORD Structural wood sheathing directly applied or 2-8-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-3-14 oc bracing. REACTIONS (lb/size) 1=5610/0-8-5 (min. 0.2-5), 7=6625/0-7-8 (min. 0-2-12) Max Horz 1=-113(LC 9) Max Uplift1=-4767(LC 4), 7--5105(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less exclept when shown. TOP CHORD 1-18=-14378/12033, 2-18=-14376/12053, 2-19— 1361'5/11190, 3-19=-13584/11177, 3-20=-11347/9163, 4-20=-11298/9164, 4-5=-11327/9169, 5-6=-14993/11810, 6-7=-19163/14692 BOT CHORD 1-21=-11536/13736, 21-22=-11536/13736, 22-23=-11536/13736, 12-23=-11536/13736, 12-24=-11536/13736, 11-24=-11536/13736, 11-25=-10670/13051, 10-25=-10670/13051, 10-26=-11227/14372, 9-26=-11227/14372, 9-27=-14041/18320, 8-27=-14041/18320, 8-28— 14041/18320, 7-28=-14041/18320 WEBS 4-10=-4861/5911, 5-10=-4380/3216, 5-9=-2508/3315, 6-9=-4346/3088, 6-8=-1826/2480, 3-10=-2764/2524, 3-11 =-1 739/1843, 2-11=-1071/1138, 2-12=-736l741 NOTES 1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 -1 row at 0-9.0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B); unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; porch left exposed; Lumber DOL-1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) Plates checked for a plus or minus 0 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4767 lb uplift at joint 1 and 5105 lb uplift at joint 7. 10) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee, P.E. #34869 Continued on page 2 1109 Coastal Bay Boynton Beach, FL 33435 Jou I russ I ruse I ype y 57380 AOBG Common Girder I 2 Job Reference (optional) Al ROOF THUSShS, FUR PItHOh, FL 34946, Hyan Spencer nun: imuu s my eo cu is rnnu 7.566 s muv m cu iu m� nn n,uusuros, um. - - .+ ID:OkilyUUrWFoYXN4BLIC Jhy732V-icMoKz32amYJif SjroGU0ps5tVtsYY04Zb J P 2 NOTES 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 66 lb down and 78 lb up at 1-4-10, and 144 lb down and 154 lb up at 5-4-10, and 109 lb down and 100 lb up at 9-4-10 on top chord, and 860 lb down and 817 lb up at 2-6-4, 47 lb down and 26 lb up at 1-4-10, 88 lb down and 33 lb up at 5-4-10, 323 lb down and 209 lb up at 9-4-10, 600 lb down and 346 lb up at 13-4-10, and 791 lb down and 364 lb up at 17-4-10, and 927 lb down and 423 lb up at 21-4-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase-1.25 Uniform Loads (plf) - Vert: 1-4=-90,4-7=-90,13-23=-20,7-23=-295(B=-275) Concentrated Loads (lb) Vert: 18=71(F) 19=-84(F) 20= 28(F) 21=10(F) 22=-860(B)j24=-55(F) 25=-323(F) 26=-600 27--791 28--927 i I Julius Lee, P.E. #M69 1109 Coastal Bay Boynton Beach, FL 33435 Job NSS NSS Type y 573BO W1 Jack -Open 1 1 Job Reference d tional „i nuur inuaa=a, rune r-i=nu=, rL J9C40, nyan opener nun. i.auu s,.ov co a 1e rnm.r.-a,.uv co-m"' Ian umusuies, I—. oar-ci_'...o cu,u ID:OkilyUUrWFoYXN4BLIG1_Jhy732V-ApwAYJ3gL gAGp1eHYJV1DLDTH2sb9Dxu9Knwly p_1 0.0-0 I 1.4.6 1.4.6 - Seale =1:6.4 4.00 12 N 1 a o i T1 m dr 0 131 i ' c o 2x4 = 0.0.0 1 4 6 1. -6 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.06 Vert(LL) 0.00 6 n/r 120 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.16 Vert(TL) -0.00 6 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(fL) 0.00 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight: 4 lb FT = 0% LUMBER TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 1-4-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=37/Mechanical, 2=1 11 /Mechanical Max Horz 3=202(LC 8), 2=197(LC 1) Max Uplift3=-42(LC 8), 2=-99(LC 8) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-531/230 BOT CHORD 1-3=-222/541 NOTES A) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0:18; MW FRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=' 1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s), for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 42 lb uplift at joint 3 and 99 lb uplift at joint 2. 7) Non Standard bearing condition. Review required. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 JOID I russ russ I ype y y 57380 CJ1A �Jack-Open 1 1 Job Reference optional Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer LOADING (psf) SPACING 2-0-0 TCLL 30.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2010/TP12007 Run: 7.500 6 NOV 26 2013 Pnnt: 7.500 6 NOV 26 2013 Mi IeK Industries, Inc. Sat Dec 21 08:49:48 2013 Page 1 ID:QWIyUUrWFoYXN4BLIC Jhy732V-ApwAYJ3gL3gAGp1eHYJV1DLE9H4ub9Dxu9Knwly6p_l 0•D•0 1.3.9 1-3-9 Scale -1:6.4 4.00 12 3 1-3.9 CSI I DEFL in (loc) I/defl Ud PLATES GRIP TC 0.02 Vert(LL) -0.00 7 >999 360 MT20 244/190 BC 0.03 Vert(TL) -0.00 7 >999 240 WB 0.00 Horz(TL) -0.00 1 n/a n/a (Matrix-M) Weight: 4lb FT-0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-3-9 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=70/0-7-4 (min. 0-1-8), 2=46/Mechanical, 4=24/Mechanical Max Horz 1=33(LC 8) Max Upliftl=-25(LC 8), 2=-38(LC 8), 4=-10(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL 11.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plateicapable of withstanding 25 Ib uplift at joint 1, 38 lb uplift at joint 2 and 10 lb uplift at joint 4. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ russ Type y 57380 CJ2 Jack -Open 2 1 Job Reference (Optional) 1 ID:OMIyUUrWFoYXN4BLI�*:Jhy732V-ApwAYj3gL3gAGp1 eHYJV1 DLEGH; fb9Dxu9Knwlydp_i 0-0.0 2-6-4. 3x6 11 Scale -1:8.2 0.0.0 z 6 4 2.6.4 Plate Offsets (X Y)• [1.0-2-14 0.0-101 11:0-1-4 1-3-4) 1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.06 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.04 Vert(TL) -0.00 4 >999 240 BCLL 0.0 Rep Stress Incr -YES WB 0.00 Horz(TL) -0.00 1 n/a n/a BCDL 10.0 Code FBC2010lfP12007 (Matrix-M) Weight: 9 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-6-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE MiTek recommends that Stabilizers and required cross Left: 2x4 SP No.3 bracing be installed during truss erection, in accordance with Stabilizer Installation uide.' REACTIONS (lb/size) 2=41/Mechanical, 3=20/Mechanical, 1=210/0-8-0 (min. 0-1-8) Max Horz 1=61(LC 8) Max Uplift2=-36(LC 8), 3=-11(LC 8), 1=-86(LC 8) Max Grav2=41(LC 1), 3=21(LC 3), 1=21 O(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL 1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 36 lb uplift at joint 2,11 lb uplift at joint 3 and 86 lb uplift at joint 1. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard i Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 I Job I russ I Was Type y 57380 CJ2A Jack -Open 1 1 Job Reference (optional) Al MUUr I Kubbrb. run I rlCMur, rL A9`J40, nyen opener 0-0-0 I 1 2x4 = D•D-0 ID:OWIyUUrWFoYXN4BLl0 Jhy732V-e?NN16No0uzarFgIZ uOkhPrKcS57p4LTBy6p_0 2.5-7 2-5-7 Scale -1:8.2 4.00 12 T1 B1 2-5.7 LOADING (psf) 2x4 = D•D-0 ID:OWIyUUrWFoYXN4BLl0 Jhy732V-e?NN16No0uzarFgIZ uOkhPrKcS57p4LTBy6p_0 2.5-7 2-5-7 Scale -1:8.2 4.00 12 T1 B1 2-5.7 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.10 Vert(LL) 0.01 3-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.11 Vert(TL) 0.01 6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 1 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 8 lb FT - O% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-5-7 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=144/0-7-4 (min. 0-1-8), 2=81/Mechanical, 3=38/Mechanical Max Horz 1=59(LC 8) Max Uplift1=-60(LC 8), 2=-60(LC 8), 3--9(LC 8) Max Grav 1-144(LC 1), 2=81(LC 1), 3=42(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less ex i ept when shown. BOT CHORD 1-3=-269/216 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TI DL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MW FRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOI-11.60 plate gdp'DOL-1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed,for a 10.0 psf bottom chord live load honconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate'capable of withstanding 60 lb uplift at joint 1, 60 lb uplift at joint 2 and 9 lb uplift at joint 3. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job Truss Inuss type y 57380 CJ2D Jack -Open 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0-0-0 D-0.0 LOADING (psf) SPACING 2-0-0 TCLL 30.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2010R'P12007 LUMBER TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEDGE Left: 2x4 SP No.3 Run: 7.500 s NOV 25 2013 Ynrtt: 7.5u0 s NOV 25 2013 m lex indusines, Inc. bat Dec 21 WKW AU 201J rage 1 ID:OkilyUUrWFoYXN4BLIQ Jhy732V-e7UZR416No0uzcxrFgkZRuPLhOxKcS57p4LTBy6p_0 3x6 11 2-0.2 2-0-2 Scale =1:7.4 CSI I DEFL in (loc) I/defl Ud PLATES GRIP TC 0.06 Vert(LL) -0.00 4 >999 360 MT20 244/190 BC 0.04 Vert(fL) -0.00 4 >999 240 WB 0.00 Horz(TL) -0.00 1 n/i n/a (Matrix-M) Weight: 8lb FT-0% BRACING TOP CHORD Structural wood sheathing directly applied or 2-0-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Rtahili7er Inctallatinn guide_ REACTIONS (lb/size) 2=14/Mechanical, 3=6/Mechanical,1-195/0-8-0 (min. 0-1-8) Max Horz 1=48(LC 8) Max Uplift2=-17(LC 8), 3=-8(LC 8), 1=-80(LC 8) Max Grav2=14(LC 1), 3=7(LC 3). 1=195(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less excll pt when shown. NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=',1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 17 lb uplift at joint 2, 8 lb uplift at joint 3 and 80 Ito uplift at joint 1. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 o russ russ I ype i y 57380 CJ3 Jack -Open 2 1 Job Reference (Optional) Ai Hour pusses, rani rienue, rL .3aanc, Ryan spencer °"' AID0WIyUUrWFoYA4BL14Jhy732V-6B2x75wtW56eAv883iEMTpu?dygp_? 0.0.0 3 -8-2 3-8-2 r Scale=1:10.0 1 D-0-0 2x4 = �� 3x6 11 4.00 12 T1 131 3.8.2 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.14 Vert(LL) 0.01 3-8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.17 Vert(fL) -0.01 3-8 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010lrP12007 (Matrix-M) Weight:13 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-8-2 oc purlins. SOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE MiTek recommends that Stabilizers and required cross Left: 2x4 SP No.3 bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=93/Mechanical, 3=42/Mechanical, 1=262/i-8-0 (min. 0-1-8) Max Horz 1=89(LC 8) Max Uplift2=-74(LC 8), 3=-13(LC 8), 1=-108(LC 8) Max Grav2=93(LC 1), 3=47(LC 3), 1=262(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES i 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOI-1.60 plate grip DOL-1.60 2) Plates checked for a plus or minus 0 degree rotation about Its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 74 lb uplift at joint 2,13 lb uplift at joint 3 and 108 lb uplift at joint 1. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay i Boynton Beach, FL 33435 Job I russ I cuss I ype i Uty y 57380 CJ3A Jack -Open 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT HF-HOE, FL 34945, Hyan spencer 0.0-0 2x4 = nun: t.buu s Nov zb zwo rnra: i.ouu s Nov zb zu i o mi ieR mausmes, mc. aai use z i uo:vyau zu o ra e ID:QkilyUUrWFoYXN4BLIQ_Jhy732V-662xy?5wthwtW6BlPzLz6eRXA4jQ331EMTpu?d p_? 3-7-5 Scale =1:10.0 0-0-0 i 3 7 5 3-7.5 _ LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TO 0.24 Vert(LL) 0.02 3-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.21 Vert(TL) -0.02 3.6 >999 240 BOLL 0.0 Rep Stress Incr YES WB j 0.00 Horz(TL) -0.00 1 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight:11 lb FT - 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-7-5 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=220/0-7-4 (min. 0-1-8), 2=122/Mechanical, 3=48/Mechanical Max Horz 1=87(LC 8) Max Uplift1=-94(LC 8), 2=-92(LC 6), 3.-5(LC 8) Max Grav 1=220(LC 1), 2=122(LC 1), 3=60(LC 3) . FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-462/480 BOT CHORD 1-3=-654/546 i NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; I WL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 94 lb uplift at joint 1, 92 lb uplift at joint 2 and 5 lb uplift at joint 3. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I Ruse ruse Type I Y ' 57380 CA Jack -Open I 2 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0.0-0 ono Nun: /.buy s Nov Z6 wou F-nnc /.buU S NOV Z6 Zu1J MI IeK Incusines, Inc. bat uec Zl uti'm u ZUl J Ya e 7 ID:OkilyUUrWFoYXN4BLIC Jhy732V-6B2xy?5wthwtW6BlPzLz6eRVS4hu33iEMTpu?dy p_? Scale - 1:11.8 °-0-0 i 4-s-1s 4-s-1s Plate Offsets (X Y): [1:0-2-14 0.0-101 [1:0-1-4 1-3-4] 1 LOADING (psf) SPACING 2-0-0 CSI 1, DEFL in (loc) I/dell Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TO 0.35 Vert(LL) 0.05 3-8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.38 Vert(TL) -0.04 3-8 >999 240 BOLL 0.0 " Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:16 lb FT - 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 I TOP CHORD Structural wood sheathing directly applied or 4-9-15 oc pudins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE MiTek recommends that Stabilizers and required cross Left: 2x4 SP No.3 bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=142/Mechanical, 3.61/Mechanical, 1=321/0-8-0 (min. 0-1-8) Max Horz 1=117(LC 8) Max Uplift2=-110(LC 8), 3=-14(LC 8), 1--133(LC 8) Max Grav 2=142(LC 1), 3=71(LC 3),1=321(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. I 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate'capable of withstanding 110 lb uplift at joint 2, 14 lb uplift at joint 3 and 133 lb uplift at joint 1. - 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I russ Type y 57380 CAA Jack -Open 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0-0-0 Run: 7.500 S Nov 26 2013 Print: 7.500 S Nov 26 2013 M7ek Industner, Inc. Sat Dec 21 08:49:51 2013 Pagel ID:DkIIyUUrWFoYXN4BLl(_Jhy732V-bNcJAK6Ye_2k7GIDygsCfszeNU1 moWyNa7ZRX4y6p_ 4-9-3 Scale-1:11.8 0-0-0 4 9 3 4-9-3 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.47 Vert(LL) 0.06 3-6 >893 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.33 Vert(TL) -0.06 3-6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WE 0.00 Horz(TL) -0.01 1 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:15 lb FT - 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-9-3 oc puriins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=298/0-7-4 (min. 0-1-8), 2=161/Mechanica1, 3=57/Mechanical Max Horz 1-116(LC 8) j Max Uplifts =-129(LC 8), 2=-124(LC 8), 3=-1(LC 8) Max Grav 1=298(LC 1), 2=161(LC 1), 3=78(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-865/917 BOT CHORD 1-3— 1219/1038 NOTES j 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load;nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 1, 124 lb uplift at joint 2 and 1 lb uplift at joint 3. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 Job russ runs I ype y 57380 OJS Jade -Open 2 1 i Job Reference o Uonal Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: 7.500 a Nov 26 2013 Print: 7.5D0 s Nov 26 2013 MTek Industries, Inc. Sat Dec 21 08:49:51 2013 Page 1 ID:OkilyUUrWFoYXN4BLICLJhy732V-bNcJAK6Ye_2k7GIDygsCfszbGUyvoWyNa7ZRX4y6p 0.0.0 5-11-13 5-11-13 3x8 I I 0-0.0 5.11-13 5-11,13 J Scale-1:13.6 Plate Offsets (X,Y): [1:0-1-3,Edgel, [1:0-0-4,Edge] I LOADING (psf) SPACING - 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.66 Vert(LL) 0.15 3-8 >487 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.65 Vert(TL) 0.12 3-8 >595 240. BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.03 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Ma trix-M) Weight: 20 lb FT - 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEDGE Left: 2x4 SP No.3 REACTIONS (lb/size) 2=190/Mechanical, 3=79/Mechanical, 1=38I/0-8-0 (min. 0-1-6) Max Horz 1=146(LC 8) Max Uplift2=-146(LC 8), 3=-15(LC 8), 1=-158(LC 8) Max Grav2=190(LC 1), 3=95(LC 3), 1=382(LC 1)' FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BOT CHORD 1-4=-285/161 1 Structural wood sheathing directly applied or 5-11-13 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Wind: ASCE 7-10; VUlt=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical (eft exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 146 lb uplift at joint 2, 15 lb uplift at joint 3 and 158 lb uplift at joint 1. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #f34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ cuss I ype I Lity Y 57380 CJSA Jack -Open 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0-0.0 3x4 = GOM Run: 7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 MTek Industries, Inc. Sat Dec 21 08:49:51 2013 Page 1 ID:QldlyUUrW FoYXN4B LIQLJhy732V-bNcJAKSYe_2k7GiDygsCfszzzU 7ooWyNa7ZRX4y6p_ _ ... ^ 5-11-1 Scale - 1:13.6 Plate Offsets (X,Y): 11:0-1-4,0-1-81 LOADING (psf) SPACING 2-0-0 CS1 DEFL in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.78 Vert(LL) 0.12 3-6 >563 360 MT20 244/190 TCDL 15.0 _ Lumber Increase 1.25 BC 0.46 Vert(TL) -0.12 3-6 >591 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 1 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:18 lb FT = 0% LUMBER TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-9-13 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=377/0-7-4 (min. 0-1-8), 2-201/Mechanical; 3=66/Mechanical Max Horz 1=144(LC 8) Max Upliftl_ 164(LC 8), 2--155(LC 8) Max Grav 1=377(LC 1), 2=201(LC 1), 3=95(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less excl pt when shown. TOP CHORD 1-2=-1389/1463 BOT CHORD 1-3=-1922/1680 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 164 lb uplift at joint 1 and 155 lb uplift at joint 2. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I cuss I russ type Uty "Iy 57380 CJ7 Jack -Open 2 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0-0-0 4x8 11 0-0.0 Run:7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 Mrrek Industries, Inc. Sat Dec 21 08:49:52 2013 Page 1 ID:QWIyUUrWFoYXN4BLICLJhy732V-3aAhNg7APIAblOKOWONRB3WpkuNOXxuXpnl?3Wy6ozz 7-1-11 3x4 11 Scale: 3/4"=1' 1.5x4 II 7-1-11 Plate Offsets (X,Y): [1:0-0-4,Edgel, [1 :0-2-14, Edge], [2:0-3-5,0.0-8] 1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.49 Vert(LL) 0.22 4-10 >375 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.37 Vert(TL) -0.18 4-10 >453 240 BCLL 0.0 Rep Stress Incr YES WB 0.15 Horz(TL) -0.05 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 26 lb FT = 0% LUMBER TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 31 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 BRACING - TOP CHORD Structural wood.sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=-270/Mechanical, 2=61O/Mechanical, 1-446/0-8-0 (min. 0-1-8) Max Horz 1=176(LC 8) Max Uplift4=-270(LC 1), 2=-440(LC 8),1 186(LC 8) Max Grav4=241(LC 8), 2=61 O(LC 1), 1=446(LC 1) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less exll ept when shown. BOT CHORD 1-6_ 389/234 WEBS 2-4=-591 /501 1 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 270 lb uplift at joint 4, 440 lb uplift at joint 2 and 186 lb uplift at joint 1. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. #M69 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ cuss ype y 57380 CJCA Jack -Open 1 1 Job Reference (optional) Al Hour i nussts, rune rienue, rL danan, nyan spencer IDAkIIyUUrWFoYXN4BLICLJhy732V-3aAhN07APIAblOKQWONR63WpOuKoX CXp,,I .My- 0.0-0 7 a 14 7-0-14 Scale-1:15.3 1 "11 B1 4• 0 3x6 = I I " 0.0-0 7 0 14 7-0.14 LOADING (psf) SPACING 2-0-0 CSI DEFL In (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.45 Vert(LL) 0.19 3-6 >438 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.54 Vert(TL) -0.20 3-6 >413 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(fL) -0.01 1 n/a n/a BCDL 10.0 Code FBC2010frP12007 (Matrix-M) Weight: 22 lb FT - 0% LUMBER BRACING TOP CHORD 2x4 SP M 31 TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=452/0-7-4 (min. 0-1-8), 2=247/Mechanical, 3=73/Mechanical Max Horz 1=173(LC 8) Max Upliftl=-196(LC 8), 2— 191(LC 8) Max Grav1=452(LC 1), 2=247(LC 1), 3=111(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2161/2220 BOT CHORD 1-3=-2518/2274 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.0psf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MW FRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL 1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load honconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 196 lb uplift at joint 1 and 191 Ito uplift at joint 2. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 JOID I russ russ I ype y 57380 F01 Floor 1 1 Job Reference (optional) Ai ROOF i nuSSFS, run i ritnut, FL.3aaao, Bryan Spencer nun: aauu s Nov 26 2013 n,rn: 7.500 s Nuv co cum mne" ,nousmes, ,nc. Sal Dec 21 ue:ge:aa 20i a ra e i ID:OIdlyUUrWFoYXN48LIL1 Jhy732V-Xmj3b07oAcISNavc45ugkH3361m7GPXg2R2Ybyy zy 0 4-8 Scale-1:11.3 LOADING (psf) SPACING 1-4-0 CSI DEFL in poc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.13 Vert(LL) . -0.00 7 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.09 Vert(fL) -0.01 7 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(TL) -0.00 4 n/a n/a BCDL 10.0 Code FBC2010frP12007 (Matrix) Weight: 30 lb FT - 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 5-6-10 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=203/0-4-0 (min. 0-1-8), 4-203/0-4-0 (min! 0-1-8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 1-7=0/259,4-6=0/259 1 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used In the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restralnea by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard ' I Julius Lee, P.E. 434869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I russ I ype y 57380 F02 I Floor I 3 1 i�Ltty Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0-3-5 Run: 7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 MTek Industries, Inc. Sat Dec 21 08:49:53 2013 Page 1 ID:OkilyUUrWFoYXN48LICLJhy732V-Xm)3b07oAcISNavc45ugkH34711zGOsg2R2Ybyy6ozy 1.3-0 1-6-10 1-6-10 Oi 3.5i �l 3x6 11 3x3 11 3x3 11 3x6.11 1 2 3 3x3 = 4 5 Scale a 1:13.5 0 O N O LOADING (psf) SPACING 1-4-0 CSI I DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.08 Vert(LL) -0.00 7-8 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.16 Vert(TL) -0.02 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.17 Horz(TL) -0.00 5 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix) Weight: 39 lb FT - 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except and verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=259/0-2-15 (min. 0-1-8), 5=259/02-15 (min. 0-1-8) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-287/0, 2-3= 285/0, 3-4=-285/0, 4-5=-287/0 BOT CHORD 7-8=0/378 WEBS 1-8=0/350, 5-7=0/350 NOTES 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1, 5. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I cuss I ype Qty 57380 F03 Floor 2 1 Fy Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0.3-5 1�� Run: 7.500 s Nov 262013 Print: 7.500 s Nov 26 2013 MTek Industries, Inc. Sat Dec 21 08:49:53 , Pagge 1 ID:OIdlyUUrWFoYXN4BL10 Jhy732V-Xmj3b07oAcISNavc45ugkH32alhCGLIg2R2Ybyy—y T� Scale =1:19.5 13 12 11 10 9 8 1.5x4 11 3x6 = 11.5x4 11 3x3 = 3x6 = 1.5x4 11 I HUB 10-8-9 11-11-14 3.5 1 10-5-4 -3- Plate Offsets (X,Y): (3:0-1-8,Edge) LOADING (psf) SPACING 1-4-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.23 Vert(LL) -0.04 9-10 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.40 Vert(TL) -0.10 9-10 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.33 Horz(TL) -0.01 7 n/a , n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight: 60 lb FT = 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathingdirectly applied or 6-0-0 oc.purlins, BOT CHORD 2x4 SP N0.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) I BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=447/0-2-15 (min. 0-1-8), 7-447/0-2-15 (mIin. 0-1-8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-555/0, 2-3=-554/0; 3-4=-1094/0, 4-5=-1094/0, 5 66=-566/0, 6-7=-567/0 BOT CHORD 11-12=0/1094, 10-11=0/1094, 9-10=0/1059 WEBS 1-12=0/680, 7-9-0/695, 5-9= 532/0, 3-12=-581/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Provide mechanical connection (by others) of truss to bearing platen at joint(s)1, 7. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I toss I cuss Type y 57380 F04 Floor 12 1 Job. Reference (option wVr �VJJ�J rv� r o o, ro„ QNo , i �U IDAkiIyUUav rWFoYXN4BLIQJhy732V-XmJ3b07oAcISNavc45ugkH3zdla7GGRg2R2Ybyygozy 03-5 1-3-0 2-6-0 2� 210, 18-0 22-9 0 6 -M i Scale m 1:36.5 3x6 = 46 11 , 3x3 11 3x6 = 1.5x4 11 3x4 = 3x4 = 1.5x4 11 3x6 FP= 3x3 11 4x6 11 1 2 3 4 T 1 51 5 6 7 8 9 10 11' I9EIN 20 19 18 17 16 15 14 13 12 1.5x4 11 3x8 = 3x6 FP= 3x6 = 1.5x4 11 1.5x4 11 3x6 = 3x8 = 1.5x4 II I 70-10-15 4 LOADING (psf) SPACING 1-4-0 CSI DEFL in- (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.31 15-16 >763 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.85 Vert(TL) -0.60 15-16 >392 360 BCLL 0.0 Rep Stress Incr YES WB 0.64 Horz(TL) -0.08 11 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix) Weight:102 lb FT = 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, SOT CHORD 2x4 SP No.2(fiat) *Except* except end verticals. 132: 2x4 SP M 30(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3(flat) REACTIONS (lb/size) 1=844/0-2-15 (min. 0-1-8), 11=844/0-3-0 (min. 0-1-8) FORCES (lb)- Max. Comp./Max. Ten. -All forces 250 (lb) or less ex Iept when shown. TOP CHORD 1-2— 1098/0, 2-3=-1096/0, 3-4= 3546/0, 4-5=-3546/0,II5-6= 3917/0, 6-7 3544/0, 7-8=-3544/0, 8-9=-3544/0, 9-10=-1097/0, 10-11=-1098/0 BOT CHORD 18-19=0/2553, 17-18=0/2553, 16-17=0/3917, 15-16=0/3917, 14-15=0/3917, 13-14=0/2554 WEBS 1-19=0/1346, 11-13=0/1346, 3-19=-1572/0, 3-17=0/1072, 5-17_ 660/0, 9-13=-1573/0, 9-14=0/1069, 6-14=-662/0 NOTES 1 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Provide mechanical connection (by others) of truss to bearing plate at joint(s)1. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between Inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 ion I russ russ I ype y 57380 FOS FLOOR 9 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer I 0-3-5 , 1.3-0 ,,, 2-7-12 I1 I� nun: /.Duu s NDV ZD ZU 1 J r 1m; /AUu s Nov CD G I 7114K InpUSVIDa, IIIp. Jal Uuu G 1 UD:YD:DY GV IJ ra a 1 ID:OkllyUUrWFoYXN4BUILJhy732V-?yHSoM8RxvW_kUoepOvGUbBgi1G?pugH5n67P N1 1-8-0 0-9.10 2-6-0 Scale-1:18.9 3x6 = 0 N Plate Offsets (X,Y): [3:0-1-8,Edge] i LOADING (psf) SPACING 1-4-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.33 Vert(LL) -0.05 9-10 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.41 Vert(fL) -0.08 9-10 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.31 Horz(TL) -0.01 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight: 52 lb FT = O%F, O%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 7=408/Mechanical, 1=408/0-3-0 (min. 0-1-8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-528/0, 2-3=-527/0, 3-4=-909/0, 4-5=-902/0 BOT CHORD 9-10=0/909, 8-9=0/909, 7-8=0/782 WEBS 1-10=0/647, 3-10=-431/0, 5-7=-842/0, 5-8=0/304 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Refer to girder(s) for truss to truss connections. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ 71russ type y 573BO FO6 FLOOR I 1 1 Job Reference (optional.) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: 7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 MTek Industries, Inc. Sat Dec 21 08:49:54 2013 Page 1 ID:OkilyUUrWFoYXN4BLICLJhy732V-7yHSoM8RxvOJ_kUoepOvGUbByi3p7gcgH5n67Pg.eL 0-6-4 1-3-0 0-9-3 ,, 1-8-0 0-9.10 2-6-0 T� Scale: 3/4"=1' 0-6-4 , 2-10-15 LOADING (psf)' SPACING 1-4-0 CSI I I DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.32 Vert(LL) -0.03 7-8 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.31 Vert(TL) -0.07 7-8 >999 360 BCLL 0.0 Rep Stress Inca YES WB 0.20 Horz(TL) 0.01 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight: 44 lb FT = 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, BOT CHORD 2x4 SP No.2(flat) I except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 7=327/Mechanical, 1=327/0-5-14 (min. 0-1-8) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-343/0, 2-3=-340/0, 3-4=-564/0, 4-5— 566/0 BOT CHORD 9-10=0/564, 8-9=0/564, 7-8=0/567 WEBS 1-10=0/418, 3-10=-379/0, 5-7=-610/0 NOTES 1) Unbalanced floor live loads'have been considered for this design: 2) Plates checked for a plus or minus 0 degree rotation about Its center. 3) Refer to girder(s) for truss to truss connections. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained Iby other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. , LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 o russ Iruss ype y 57380 �F07 Floor 1 1 Job Reference (option Q MI nwr nupJC.7, rvn i r�cnVC, r� uYa+o, n)— uNo�i�oi ....� �......... o �.... -.. ................_.._ .. .._. __ __._ ..... _.. ...___...__, ..._. __. ___ _. __. ._._ . __. _ _ _ . ID:OkilyUUrWFoYXN4BLICLJhy732V-?yHSoMBFIxvQJ_kU36pY UbECi58?gVgH5n670 ozx 0-6-4 1.3-0 1-5-14 1-5-14 D:3-12i Scale-1:13.8 3x3 11 2 3x3 11 3x6 11 33x3 = 4 5 6 3x6 = 3x6 10 98= 7 1.5x4 11 1.5x4 11 0-6-4 LOADING (psf) SPACING 1-4-0 CSI I DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 10.18 Vert(LL) -0.01 8 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.16 Vert(TL) -0.02 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.21 Horz(TL) -0.00 6 n/a n/a BCDL 10.0 Code FBC2010fTPI2007 (Matrix) Weight: 39 lb FT = 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) ( BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=270/0-5-14 (min. 0-1-8), 6-265/0-2-1 (min. 0-1-8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-300/0, 2-3--298/0, 3-4=-351/0, 4-5=-350/0 BOT CHORD 8-9=0/404 WEBS 1-9=0/366, 5-8=0/431 NOTES 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Provide mechanical connection (by others) of truss to bearing plate tat joint(s) 6. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I runs Type y 57380 FOB Floor 1 1 Job Reference (optional). M 1 mV Vr i nwoo=o, rwr I rl=mu=, m aYrgo, nyan opancer I nun: /.ouu a IYov do 4u I rnnr. I.ouu a IVOv Zo CU Ia IVII eR Inuueul g Inc. oat Uec e 1 Ua:9a:aa ZUIa ra e 7 ID:OkilyUUrWFoYXN4BLIC Jhy732V-T9rg0i9.3167 u3_BWx8pi80J5TgkJfzVIXffry ozw 0-6-6 - ' 1 4-3! 0-3-12 3 6 11 i 3 6 i i 3x6 11 Scale -1:8.1 1 1 2 3 4 LOADING (psf) SPACING 1-4-0 CSI I DEFL in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.09 Vert(LL) -0.00 6 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.02 Vert(TL) -0.00 5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.08 Horz(TL) -0.00 4 n/a n/a BCDL 10.0 Code FBC2010frP12007 (Matrix) Weight: 24 lb FT - 0%F, 0%E LUMBER I BRACING TOP CHORD 2x4 SP No.2(flat) I TOP CHORD Structural wood sheathing directly applied or 3-11-1 oc pur ins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=144/0-5-14 (min.0-1-8),4=139/0-2-6 (min.0-1-8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Provide mechanical connection -(by others) of truss to bearing plate at joint(s) 4. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0.0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ Irugs ype y y 57380 F09 ROOFTRUSS 1 1 Job Reference (optional) nl nwr I nwoco, r�nl nonvc, rL aYaYo, nytln optlrnal nun. lD:OkilyUUrWFonYXN4BLl0 Jhy732V-T9rgoiealDYAcu3_BWxBpiBHjSLgkFtzVlXffry6ozw 0-3-5 130 u , 2-6-0 1_ 1� 2-0-0 2-2-6 0�6� Scale -120.6 I 3x6 11 3x3 I I 3x3 1.5x4 11 3x3 11 3x6 11 e d 63x3 — 0 4C6 13 12 11 10 9 6. 1.5x4 11 3x6 = I 3x3 = 1.5x4 11 3x6 = 1.5x4 11 LOADING (pso _ SPACING 1-4-0 CSI I DEFL in (loc) I/defl Vd PLATES GRIP TCLL - 40.0 Plates Increase 1.00 TC 0.70 Vert(LL) 0.2611-12 >497 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 6.53 Vert(TL) 0.23 11-12 >558 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.33 Horz(TL) 0.02 7 n/a ' n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix) Weight: 65 lb FT - 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) I BOT CHORD Rigid ceiling directly applied or 8-10-6 oc bracing. REACTIONS (lb/size) 1=473/0-2-15 (min. 0-1-8), 7=473/0-5-14 (min. 0-1-8) Max Upliftl=-380(LC 9), 7=-380(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-458/890, 2-3=-457/893, 3-4 908/1743, 4-5=-908/1743, 5-6=-423/803, 6-7— 425/801 BOT CHORD 11-12=-1619/873, 10-11--1738/908, 9-10=-1738/908 WEBS 1-12=-1228/632, 7-9=-1103/585, 3-12=-472/829, 5-9=-563/1093 I NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantileverlleft and right exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Plates checked for a plus or minus 0 degree rotation about its center) 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 380 lb uplift at joint 1 and 380 lb uplift at joint 7. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Jou I russ I russ I ype I Lqy illy 57380 F10 ROOFTRUSS 1 1 1 Job Reference (optional) Al MUUr I MUbbtb, rUM I rltHUt, M J4`J4b, nyan bpencer nun; /.auU s N V eb eUTA rnni: /.DUU s rvov Zb aUl J MI IeK Inausines, Inc. Jai UBc el uu:49:bo eui J ra e ID:OkilyUUrWFoYXN4BLIGLJhy732V-T9rg0i93iDYAcu3_BWx8pi8Mt5NEkGMzVIXffry ozw 0-3-5 , 13.0 2-6-0 1-1.3 , 2-0-0 , , _ 2-5-8 , , 1-9-8 OBE Scale -124.9 LOADING (psf) SPACING 1-4-0 CSI TCLL . 40.0 Plates Increase 1.00 TC TCDL 15.0 Lumber Increase 1.00 BC BCLL 0.0 Rep Stress Incr YES WB BCDL 10.0 Code FBC2010/7PI2007 (Me 6-6.0 , 7-6-0' . 1 DEFL in (loc) Well Ud Vert(LL) 0.0813-14 >999 360 Vert(TL)-0.1213-14 >995 240 Horz(TL) -0.01 11 n/a n/a PLATES GRIP MT20 244/190 Weight: 80 lb - FT - 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=462/0-2-15 (min. 0-1-8), 8=249/0-5-14 (min. 0-1 -8), 11=435/0-9-4 (min. 0-1-8) Max Upliftl= 189(LC 8), 8=-151(LC 8), 11=-249(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-466/334, 2-3=-466/337, 3-4 894/640, 4-5=-894/640, 5-6=-280/196, 6-7 281/198, 7-8= 208/262 BOT CHORD 13-14=-644/876, 12-13=-635/893, 11-12 635/893, 10'11=-260/207 WEBS 1-14=-459/642, 8-10=-359/286, 3-14=-466/354, 5-11=-693/500 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL-1.60 2) Provide adequate drainage to prevent water ponding. 1 3) Plates checked for a plus or minus 0 degree rotation about its center! 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurr(int with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 189 lb uplift at joint 1, 151 Ito uplift at joint 8 and 249 lb uplift at joint 11. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 10) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I russ Type Qty y 57380 F11 ROOFTRUSS 1 1 I Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: 7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 Welt Industries, Inc. Sat Dec 21 08:49:56 2013 Page 1 ID:QkilyUUrWFoYXN48LIC_Jhy732V-xLPCD2AhTXg1 El eBIESNMvgXsVijTjg7kPGCCHysozv 0-3-5 1�3-0 „ 2-6.0 1•1 3 „ 2-0-0 1-8-4 2.6-0 2-2-15 Seale =129.2 3x3 = 1.5x4 11 3x3 II 3x6 FP= I 3x3 = 1.5x4 II LOADING (psf) SPACING 1-4-0 CSI I DEFL in ..(loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.36 Vert(LL) 0.0916-17 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC b.48 Vert(TL)-0.1316-17 >840 240 BCLL 0.0 Rep Stress Incr YES WB 6.29 Horz(TL) -0.01 14 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight: 92 lb FT = O%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1 =45410-2-15 (min. 0-1-8), 10=364/0-5-14 (min. 0-1-8), 14=528/0-9-4 (min. 0-1-8) Max Uplifts=-185(LC 12), 10=-253(LC 8),14--338(LC 81 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-457/300, 2-3=-456/303, 3-4=-853/546, 4-5= 853/546, 5-6--853/546, 6-7--430/276, 7-8=-5861761, 8-9=-586f761, 9-10=-328/474 BOT CHORD 16-17=-566/847,15-16=-542/852, 14-15=-542/852, 13I14— 272/429,12-13=471/327 WEBS 1-17=-412/630, 9-12--291/282, 10-12— 652/452, 7-14 =-224/382, 3-17=-444/304, 6-14=-524/335, 7-13=-544/190, 9-13=-329/299 NOTES 1 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; cantileverlleft and right exposed ; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are 3x6 MT20 unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center: 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 185 lb uplift at joint 1, 253 lb uplift at joint 10 and 338 lb uplift at joint 14. 9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 11) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ russ ype�"'y 57380 F12 ROOF TRUSS 1 1 Job Reference (optional) n, nwr , nuaaca, run, ricnuc, rL a4u4o, nyan apanuur ! nun: aouu 6 ,vov co cu,a rune i.ouu a nov cc cu, a mnan inausmus mc. aat uB0 zl u0:4a:ab eul a rage l ID:OkilyUUrWFoYXN4BL10 Jhy732V-xLPCD2AhTXgiEleSESNMvgWLVkcTin7kPGCCHy ozv 0-3-5 1 1-3-0 „ 2.6-0 1-1-3 „ 2.0.0� 1-1-0 ! • 2-7-15 R� Scale - 1:33.5 30 = 3x6 11 1.5x4 11 1.5x4 II 3x3 = 3x3 11 3x6 FP= 1.5x4 II 3x3 = 3x3 = 3x6 II 1 2 3 4 5 6 7 8 9 10 T.14 11 12 13 O �9 G a'a 22 21 20 19 I18 a 77e 16 15 14 1.5x4 II 3x6 = 3x6 FP= 3x3 = 1 l.5x4 II 3x8 = 3x3 = 3x6 = 1.5x4 II 0.3�5 5.4.8 5 &06.6.0 7.6.0 I,. 8.9-15 18.2.14 18-9-2 0'-3-5 5-1-3 a9`•81.0 0 1-0-0 1r 1-4-0 9-4.15 6-4 Plate Offsets (X,Y): (8:0-1-8,Edge) LOADING (psf) SPACING 1-4-0 CS DEFL in (loc) I/defl Ud ' PLATES GRIP TCLL . ,40.0 Plates Increase 1.00 TC 0.39 Vert(LL) 0.3015-16 >375 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.36 Vert(TL) 0.2615-16 >425 240 BCLL 0.0 ' Rep Stress Incr YES WB 6.35 Horz(TL) -0.02 17 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix) Weight:101 Ib FT = O%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP M 30(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10.0.0 oc bracing. REACTIONS (lb/size) 1=434/0-2-15 (min. 0-1-8), 13=463/0.5-14 (min. 0-1-8), 17=649/0-8-0 (min. 0-1-8), Max Uplifts 177(LC 12), 13=-340(LC 8), 17=-444(LC 8)1 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-431/261, 2-3=-430/263, 3-4=-430/263, 4-5=-765/4,11, 5-6=-765/411, 6-7=-440/174, 7-8=-438/172, 8-9=-906/1219, 9-10=-906/1219, 10-11=-440/735, 11-12=-440/735, 12-13=-441r/33 BOT CHORD 20-21=-468/787, 1'9-20=-468/787, 18-19=-407/764, 17-1B=-407/764, 16-17=-1214/906, 15-16=-1135/850 WEBS 1-21=-357/593,13-15=-1010/609, 4-21=-406/238, 6-17=-473/345, 10-15— 471/459, 8-16=-329/78, 8-17= 547/1165 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Op'sf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Plates checked for a plus or minus 0 degree rotation about its center.) 4) This truss has been designed for a 10.0 psf bottom chord live load nohconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s)1. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 177 Ito uplift at joint 1, 340 lb uplift at joint 13 and 444 lb uplift at joint 17. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 10) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 oI russ I russ I ype CAyply 57380 F13 ROOFTRUSS 3 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0-3-5 1I .9-0 2-6-0 1-1-3 2-0-0 1� 0-15� I 3x3 I I 3x3 = 1.5x4 11 1.5x41 Run: 7.500 a Nov 26 2013 Print: 7.500 s Nov 25 2013 MiTek Industries, Inc. Sat Dec 21 08:49:57 2013 Page 1 I D:QldlyU Ur W FoYXN4BLICLJhy732V-PXzaROAJEgou rB D NJxzcu,73DeeT3vzGCSKGz30mkjy6ozu 1�— O93-0 Scale =1:36.5 3x3 = 3x3 = 1.5x4 II 3x6 FP= 3x3 1.5x4 11 3x6 FP=3x3 = 3x3 1.5x4 6-6.0 1 8-11-7 1-n-n Plate Offsets (X,Y): [21:Edge,0-0-12) 1 LOADING (psf) SPACING 1-4-0 CSI I DEFL In (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.56 Vert(LL) 0.3314-15 >403 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 - BC 0.78 Vert(TL) 0.2914-15 >459 240 BCLL 0.0 ' Rep Stress Incr YES WB 6.33 Horz(TL) -0.02 16 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:110 lb FT = 0%F, 0%E LUMBER I BRACING TOP CHORD 2x4 SP N0.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10.0.0 oc bracing, Except: 2-2-0 oc bracing:14-15. REACTIONS (lb/size) 1=417/0-2-15 (min. 0-1-8), 12=51410-2-15 (min. 0-1-8), 16=756/0-8-0 (min. 0-1-8) Max Upliftl=-169(LC 12), 12=-388(LC 8), 16— 524(LC 81 FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-421/244, 2-3=-421/247, 3-4=-695/312, 4-5=-695/312, 5-6--695/312, 6-7=-331/100, 7-8=-1147/1692, _ 8-9=-1147/1692, 9-10= 1147/1692, 10-11 =-498/824,11-12=-499/822 BOT CHORD 19-20=-406/741, 18-19=-406/741, 17-18=-308/694, 16,,17=-97/330, 15-16=-902/817, 14-15=-1413/998 WEBS 1-20=-335/581, 12-14=-11331688, 5-17= 279/253, 6-1=-420/264, 3-20=-364/186, 6-17=-337/538, 10-14=-568/674, 10-15=-311/168, 7-15=-891/374, 7-16=-620/1012 NOTES I 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever�left and right exposed ; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are 3x6 MT20 unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s)1, 12. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 169 lb uplift at joint 1, 388 lb uplift at joint 12 and 524 lb uplift at joint 16. 9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 11) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job Iruss I russ I ype I y 57380 �P`14 �ROOFTRUSS 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: 7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 Mrrek Industries, Inc. Sat Dec 21 08.49:58 2013 Page 1 ID:OkilyUUrWFoYXN4BLILt_Jhy732V4kXyekBx?8wlTLoZteUrRKms_JOdxd?PBJIJGAy6ort 0-3-5 13011 2-6-0 1.1.3 2-0-0 1-0-15 , 2-8.14 2-10-6 01 8 Stale -1 :26.1 16 0 q-3.5 8.9-15 1 , 11-9-13 14-11-3 3-5 "A 0 1 2-11-14 3-1-6 Plate Offsets (X,Y): [8:0-1-8,Edgel, [10:0-1-8,Edgel, [1S:Edge,0-0-12), [16:0-1-8,0-0-12) LOADING (psf) SPACING 1-4-0 CSI I DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TO 0.38 Vert(LL) 0.09 13-14 >999 360 MT20 244/190 1 TCDL 15.0 Lumber Increase 1.00 BC 0.51 Vert(TL) -0.1313-14 >776 240 BOLL 0.0 ' Rep Stress Incr YES WB 0.30 Horz(TL) -0.02 11 n/a n/a BCDL 10.0 Code FBC2010frP12007 (Matrix) - Weight: 83 lb FT. 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. REACTIONS (lb/size) 9=366/0-6-14 (min. 0-1-8), 1-448/0-2-15 (min. 0-1-8), 11=435/0-8-0 (min. 0-1-8) Max Horz 1=3(LC 8) Max Uplift9=-244(LC 8), 1=-183(LC 12), 11--292(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 9-16=-350/428, 8-16= 349/428, 1-2=451/306, 2-3= 451/309, 34=-829/549, 4-5=-829/549, 5-6=-522/351, 6-7=-519/348, 7-8=-589/767 BOT CHORD 13-14=-580/832, 12-13=-549/829, 11-12--549/829, 10111=-767/589 WEBS 1-14— 428/624, 3-14— 432/308, 5-11--447/289, 7=11=-97/464, 8-10= 823/631 NOTES i 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 1 3) Plates checked for a plus or minus 0 degree rotation about its center: 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. - 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 244 lb uplift at joint 9, 183 lb uplift at joint 1 and 292 lb uplift at joint 11. - 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Gap between inside of top chord bearing and first diagonal or vertical, web shall not exceed 0.500in. 10) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I ruse I ype y 57380 F15 ROOF TRUSS 4 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run:7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 MMek Industries Inc. Sat Dec 21 08:49:58 2013 Page 1 ID:OkilyUUrWFoYXN4BLl0 Jhy732V-tkXyekBx?BwltLo2teUrRKmrpJLjxdOPB)UGAy6ort 0-3-5 H 13-0 2-6-0 1-1-4 2-0-0 11-1-2 1-7-1 0uu1 8 Sdale =1:23.4 1.5x4 11 3x6 11 3x3 11 3x3 —_ 11.5x4 11 3x3 = 3X3 11 3x6 = 1.5x4 = 14 5 6 7 8 I - I 15 14 13 12 d. d• ° d• 10 d• d d' d• 1.bx4 11 3X6 = LOADING (psf) SPACING 1-4-0 TCLL 30.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC201 O/TPI2007 LUMBER TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) 3X3 = 1.bX4 II 11 1=4 II 3x6 = 3X6 = CSI , DEFL in (loc) I/defl L/d PLATES GRIP TC 0.39 Vert(LL) 0.0913-14 >999 360 MT20 244/190 BC 0.70 Vert(TL)-0.2013-14 >516 240 WB 6.30 Horz(TL) -0.02 11 • n/a n/a (Matrix) Weight: 77 Ito FT = 0%F, 0%E BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 1'0-0-0 oc bracing. REACTIONS (lb/size) 9=317/0-6-14 (min. 0-1-8), 1=538/0-2-15 (min. 0-1-8), 11=412/0-8-0 (min. 0-1-8) Max Horz 1=3(LC 12) Max Uplift9--186(LC 8), 1=-28(LC 12), 11=-81(1-0 8) FORCES (lb) - Max. Comp./Max: Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-603/129, 2-3=-603/133, 3-4=-994/359, 4-5=-994/359, 5.6=-541/270, 6-7=-541/269 BOT CHORD 14-17=-389/985, 13-17=-389/985, 12-13=-359/994, 11-'12=-359/994, 10-11=-516/489, 9-10=-516/489 WEBS 1-14=-183/834, 3-14=-433/291, 7-9— 546/576, 5-11— 663/131, 7-11=0/313 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; porch right exposed; Lumber DOL-1.60 plate grip DOL-1.60 2) C-C wind load user defined. 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about Its center.) 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s)1. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 186 Ito uplift at joint 9, 28 lb uplift at joint 1 and 81 lb uplift at joint 11. 9) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 10) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 12) CAUTION, Do not erect truss backwards. 13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)160 Ito down at 2-6-0, and 160 Ito down at 7-6-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 14) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 9-1 5=-1 3, 1 -8=-60 Concentrated Loads (lb) Vert: 12— 160(F) 17=-160(F) 2) Dead + 0.75 Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Julius Lee, P.E. #34869 Continued on page 2 1109 Coastal Bay Boynton Beach, FL 33435 job I russ ruse I ype y 57380 F15 �RIOOFTRUSS 4 1 Job. Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34945, Ryan Spencer Hun: 7.500 Is Nov 25 2013 Print: 7.590 s Nov 26 2013 MITeK Industries Inc. Sat Dec 21 08:49:58 2013 Page 2 ID:QldlyUUrWFoYXN4BLl(� Jhy732V-tkXyekBx7BWWoZteUrRKmrpJLjxdOPBJIJGAy6ort LOAD CASE(S) C Uniform Loads (plf) Vert: 9-1 5=-1 3, 1-8=-50 Concentrated Loads (lb) Vert:12=-160(F) 17=-160(F) 3) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.2I5, Plate Increase=1.25 Uniform Loads (plf) Vert: 9-15=-27,1-8=-20 Concentrated Loads (lb) Vert: 12— 160(F)17=-160(F) 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 11-15=-7, 9-11=85, 1-8=75 Horz: 1-2=-81 Concentrated Loads (lb) Vert: 12= 160(F) 17_ 160(F) 5) Dead + 0.6 C-C Wind (Pos. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert:11-15=-7, 9-1 1=85,1-8=75 Horz: 1-2=-81 Concentrated Loads (lb) Vert: 12=-160(F)17 160(F) 6) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 11-15=-13, 9-11=-1, 1-8— 43 Horz: 1-2=23 Concentrated Loads (lb) Vert: 12=-160(F) 17=-160(F) 7) Dead + 0.6 C-C Wind (Neg. Internal) Case 2: Lumber Increase-1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 11-1 5=-13, 9-11=-1, 1-8=-43 Horz: 1-2=23 Concentrated Loads (lb) Vert: 12— 160(F) 17=-160(F) 8) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase-1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 11 -1 5=-7, 9-11=27, 1-8=43 Horz: 1-2=-49 Concentrated Loads (lb) Vert: 12— 160(F)17— 160(F) 9) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert:11-15=-7, 9-11=27, 1-8=43 Horz:1-2=-49 Concentrated Loads (lb) Vert: 12=-160(F) 17=-160(F) 10) Dead+ 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=4-60 Uniform Loads (plf) Vert: 11-15=-13, 9-11=20, 1-8=9 Horz: 1-2=-29 Concentrated Loads (lb) Vert: 12=-1 60(F) 17=-160(F) 11) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 11-15=-13, 9-11=20, 1-8=9 Horz: 1-2=-29 Concentrated Loads (lb) Vert: 12=-160(F) 17=-160(F) 12) Dead+ 0.6 MWFRS Wind (Pos. Internal)1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 9-15= 7, 1-8=43 Horz: 1-2=-49 Concentrated Loads (lb) Vert: 12=-160(F) 17=-160(F) 13) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 9-15=-7, 1-8=43 Horz: 1-2=-49 Concentrated Loads (lb) Vert:12=-160(F) 17 160(F) 14) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 9-15=-7, 1-8=43 Horz: 1-2=-49 Concentrated Loads (lb) Vert: 12— 160(F) 17=-160(F) 15) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1,60, Plate Increase=1.60 Uniform Loads (plf) Virt:-9=15= 7, 1-8=43 Horz: 1-2=-49 Concentrated Loads (lb) Vert: 12=-160(F) 17=-160(F) Continued on page 3 Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job ruse I russ I ype y 57380 �F15 ROOF TRUSS 4 1 Job Reference (optional) Al HOOF I NUS5t5, hOM I FMHUt, M J494ti, nyan spencer nun: iauu 5 NOV zo zu I a rnrn: 1,WO 51111 114111, yen maU 1, me. OM uec c i ue:ra:oo cu ro raga u ID:OkilyUUrWFoYXN4BLIQ Jhy732V-tk ;G&X48ZNLoZteUrRKmrNLJxdOPBJWUG y6ort LOAD CASE(S) 16) Dead + 0.6 MWFRS Wind (Neg. Internal) 1 st Parallel: Lumber In rease=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 9-15=-13, 1-8=9 Horz:1-2=-29 Concentrated Loads (lb) Vert:12=-160(F) 17=-160(F) 17) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase-1.60 Uniform Loads (plf) Vert: 9-15=-13, 1-8=9 Horz: 1-2=-29 Concentrated Loads (lb) Vert:12=-160(F) 17— 160(F) 18) Dead: Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90 Uniform Loads (plf) Vert: 9-15=-13, 1-8=-20 Concentrated Loads (lb) Vert: 12=-160(F)17=-160(F) 19) Dead + 0.75 Roof Live (be[.) + 0.75(0.6 C-C Wind (Neg. Int) Case 1): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert:11-15=-13, 9-11=-4, 1-8=-67 Horz:1-2=17 Concentrated Loads (lb) Vert:12=-160(F) 17=-160(F) 20) Dead + 0.75 Roof Live (be[.) + 0.75(0.6 C-C Wind (Neg. Int) Case 2): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 11-15=-13, 9-11=-4, 1-8— 67 Horz:1-2=17 Concentrated Loads (lb) Vert: 12=-160(F) 17=-160(F) 21) Dead + 0.75 Roof Live (be[.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 11 -15=-1 3, 9-1 1=12,1-8=-28 Horz: 1-2=-22 Concentrated Loads (lb) Vert: 12=-160(F) 17=-160(F) 22) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 11-15=-13, 9-11=12, 1-8=-28 Horz: 1-2=-22 Concentrated Loads (lb) Vert: 12 160(F) 17=-160(F) 23) Dead + 0.75 Roof Live (be[.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 9-15=-13,1-8_ 28 Horz: 1-2= 22 Concentrated Loads (lb) Vert: 12=-160(F) 17=-160(F) 24) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 9-15=-13, 1-8=-28 Horz: 1-2=-22 Concentrated Loads (lb) Vert: 12=-1 60(F) 17— 160(F) j Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 o russ I russ Type y y 57380 F16 Floor 3 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run:7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 MTek Industries, Inc. Sat Dec 21 08:49:58', Page 1 ID:GkilyUUrWFoYXN4BLl(3_Jhy732V-tkXyekBx?8wiTLoZteUrRKmnOJKGxZXPBjUGAy6ort 0-3-8 H 1i-2 0 1 1-2-8 2-5.9 2�� 1-1-14 1 2-6-0 Scale m 1:29.0 17 16 15 14 13 12 11 1.5x4 II 46 = 3x6 FP= 3x3 = 3x6 = 3x6 = 3x4 = 1-7.0 LOADING (psf) SPACING 1-4-0 CSI I DEFL in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.68 Vert(LL) -0.20 12-13 >953 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.73 Vert(TL) -0.40 12-13 >480 360 BCLL 0.0 Rep Stress Incr NO WB 0.52 Horz(TL) 0.03 11 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight: 88 lb FT - 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(fiat) *Except* TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, T2: 2x4 SP M 30(flat) except end verticals. BOT CHORD 2x4 SP No.2(flat) *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. B2: 2x4 SP M 30(flat) WEBS 2x4 SP No.3(flat) REACTIONS (lb/size) 1=847/0-3-0 (min. 0-1-8), 1 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2--772/0, 2-3--769/0, 3-4=-2270/0, 4-5=-2270/0; 5-6'— 2270/0, 6-7=-2054/0, 7-8=-2054/0, 8-9=-2054/0 BOT CHORD 16-18=0/1316, 15-18=0/1316, 14-15=0/1316, 14-19=0/2270, 13-19=0/2270, 12-13=0/2365, 11-12=0/1245 WEBS 4-14--339/013-16=-806/0, 3-14=0/1093, 9-11=-1405/01 9-12-0/918,-6-12=-373/0, 6-13=-252/163,1-16=0/1097 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about Its center: 3) Refer to girder(s) for truss to truss connections. 4) Load case(s)1, 2, 3, 4, 5, 6 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 1 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 8) CAUTION, Do not erect truss backwards. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 100 lb down at 2-6-0, and 100 lb down at 7-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (pif) Vert: 11-17=-13, 1-10=-73 Concentrated Loads (lb) Vert: 18=-100(F) 19=-100(F) 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-13, 1-10= 73 Concentrated Loads (lb) Vert: 18=-100(F) 19=-100(F) 3)1 st chase Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11 -1 7=-1 3, 1-5=-73, 5-10=-20 Julius Lee, P.E. #34869 Continued on page 2 1109 Coastal Bay Boynton Beach, FL 33435 Job I toss I cuss Type Uty y ' 57360' F16 i Floor 3 1 - � Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Hurl: /.b00 S NOV 26 Zu73 FrIM: /.00U S NOV Zb ZU14 MI 113K Inoueine6, Inc. fiat Uec zi utmu:b6 2ui a rage z ID:OWIyUUrWFoYXN4BLIO Jhy732V-tkXyekBx78wITLoZteUrRKmnOJKGxZXPB)IJGAy6ort LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 18=-100(F)19— 100(F) 4) 2nd chase Dead + Floor Live (unbalanced): Lumber Increase=1.00; Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-13,1-4=-20, 4-10=-73 Concentrated Loads (lb) Vert: 18=-100(F)19=-100(F) 5) 3rd chase Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-13, 1-5— 73, 5-10=-20 Concentrated Loads (lb) Vert: 18=-100(F) 19=-100(F) 6) 4th chase Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 11-17=-13, 1-4= 20, 4-10= 73 Concentrated Loads (lb) Vert: 18=-100(F) 19=-100(F) Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 o russ I cuss I ype t y 57380 F17G Floor Girder 1 1 Job Reference (optional) „c nuur 1 musses, run, r,enue, ru.J4a4b, nyan spencer nun: t.ouu s rvov zo zuca rnnc: i.auv s Nov eo eu, a m, len IOanS[ne6, mc. sac uec zI ue:4aaa zuc a ra e I ID:QkilyUUrWFoYXN4BLlp Jhy732V-Mw5Lr4CZmS2c5VNm�M74zYlzkje2gyBZQNVsocy ozs 0.3-5 H I� 1-2-3 1-i 1-0-9 � 2-6-0 „ 2-0-0 „ 1-0-9 , 2-0-5 r-� , 1-5-7 „ 1-4-11 , Scale =1:35.6 1 ►C1.\` 1\ III `l �iNI !t W� I a. 1 1 1 a3•s 0-Jr7 1.7-0 5.6.1 6.6.1 7-6.1 16-9-11 18.5.6 20-1-14 0- 7 1.3-11 3-11-1 1-0.0 1-0.0 9-3.10 1-7-11 1-8-7 0-1.14 1 (sets (X.Y): 11:0-3-0.Edoel,12:0-3-O.Edoel, f4:0-1-8,Edoel, r5:0-3.0.0-0-01. f7:0-3-O.Edoel. H2:0-3-O.Edoel. 113:0-1-8,Edoel, f14:0-3.O.Edael.116:0-3-4.Ed LOADING (psf) SPACING 1-4-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.64 I Vert(LL) -0.27 20-22 >887 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.88 Vert(TL) -0.53 20-22 >445 360 MT20H 187/143 BCLL 0.0 Rep Stress Incr NO WB 1 0.82 Horz(TL) 0.02 15 n/a n/a BCDL 10.0 Code FBC2010lrP12007 (Matrix) Weight: 168 lb FT - 0%F, 0%E LUMBER BRACING TOP CHORD 2x4-SP M 30(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP M 30(flat) except end verticals. WEBS 2x4 SP No.3(flat) *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.. W7,W8: 2x4 SP No.2(flat) REACTIONS (lb/size) 1=1182/0-2-15 (min.0-1-8), 15=3337/Mechanical FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 14-15=-3336/0, 1-2=-1189/0, 2-3=-2019/0, 3-4=-2019/O, 4-5=-4418/0, 5-6=-4418/0, 6-7=-4418/0, 7-8=-6112/0, 8-9=-6112/0, 9-10=-6112/0, 10-11=-6285/0, 11-12=-6285/0, 12-13=-6074/0, 13-14=-3772/0 BOT CHORD 24-25=0/1189, 23-24=0/4418, 22-23=0/4418, 21-22=0/5366, 20 21=0/5366, 19-20=0/6413, 18-1 9=0/6413,17-18=0/6074,16-179!0/3772 WEBS 4-24=-2657/0, 4-23=0/467, 5-22=0/769, 10-20= 413/0, 7-20=0/947, 2-24=0/1215, 2-25=-1 027/0,1-25=0/1 645, 7-22=-1523/0,12-17_ 1871/0,12-18=01356, 13-16=-2885/0, 13-17=0/2893, 14-16=0/4809 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) All plates are 3x6 MT20 unless otherwise indicated. 4) Plate(s) at joint(s) 26, 14, 1, 9, 4, 23, 22, 5, 3, 18, 11, 10, 20, 8, 7, 24, 2, 25, 19, 6, 12, 15, 16, 13 and 17 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s) 21 checked for a plus or minus 5 degree rotation about its center. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s)1. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 11) CAUTION, Do not erect truss backwards. 12) Use USP MSH422 (With 10d nails into Girder & 10d nails into Truss) or equivalent at 16-9.11 from the left end to connect truss(es) F19 (1 ply 2x4 SP) to back face of top chord, skewed 0.0 deg.to the left, sloping 0.0 deg. down. 13) Fill all nail holes where hanger is in contact with lumber. 14) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 15-26=-13,1-12=-73, 12-14=-573 Julius Lee, P.E. #34869 Continued on page 2 1109 Coastal Bay Boynton Beach, FL 33435 J013 Truss I cuss I ype i y 57380 F17G Floor Girder 1 1 _ Job Reference (optional) Al nWr I MUsbts, run I MrHUr, rL J484b, nyan spencer nun: /.buu s Nov zb eui j rnm: /.buU S rvov zb zU1J MueK Inaus[nes, Inc. sat uee zi ob:4e:b9 zo13 reg0 z ID:QldlyUUrWFoYXN4BLIQ Jhy732V-Mw5Lr4CZmS2c5VNmQM?4zYlzkje2gyBZaNVsocyeozs LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 12= 1200(B) Julius Lee, P.E. *34869 1109 Coastal Bay Boynton Beach, FL 33435 Job russ rusS Type I y 57380 �F118 Floor 10 1 Job Reference (optional) nun: i.— a a root. i auu n rvw co cu i u mne" mausmns, mc. aa[ uec [, ue:va'oB ZU14 ra B ID:pkilyUUrWFoYXN48L10_Jhy732V-Mw5Lr4CZmS2c5VNmpM?4zYlxUjggrZpNVsocy ozs 0-3.8 1-2-8 , 2.5-10 �2-0.0 „ 1-10-4 „ 2-6-0 46 11 3x3 11 3x6 = 1.5x4 11 30 = 1.5x4 11 3x3 = 9 A d F' R 7 0 8 3kale =1:36.5 1.5x4 II 3x6 FP= 3x4 = 3x3 II 4x6 it 1.5x4 II 4x6 = 3x6 FP= 3x6 = 1.5x4 II 3x6 = 3x6 = 4x6 = 1.5x4 II 20-1-14 LOADING (psf) SPACING 1-4-0 CSI DEFT in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.72 Vert(LL)-0.3216-17 >738 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.76 Vert(TL)-0.5916-17 >396 360 BCLL 0.0 Rep Stress Incr YES WB 0.65 Horz(TL) -0.06 12 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:108 lb FT - 0%F, 0%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) *Except* TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, T2: 2x4 SP M 30(flat) except end verticals. BOT CHORD 2x4 SP No.2(flat) *Except` BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 132: 2x4 SP M 31(flat) WEBS 2x4 SP No.3(flat) I REACTIONS (lb/size) 1=843/0-3-0 (min. 0-1-8),12-843/0-3-0 (min. 0-1-8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less exlcept when shown. TOP CHORD 1-2=-732/0, 2-3=-730/0, 3-4=-2542/0, 4-5=-2542/0, 5-6=-3048/0, 6-7= 3048/0, 7-8= 2350/0, 8-9=-2350/0, 9-10=-2350/0, 10-11=-747/0, 11-12=-750/0 BOT CHORD 19-20=0/1 350,18-19=0/1350, 17-18=0/2542, 16-17=0/2542, 15-16=0/2857, 14-15=0/1378 WEBS 4-18=-411/0, 5-17=-274/0, 3-20=-913/0, 3-18=0/1357,10-14=-930/0, 10-1 5=0/1 103, 7-15=-575/0, 6-16=-304/0, 5-16=0/728, 12-14=0/1065, 1-20=0/1041 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius tee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ russ Type y 57380 �F19 FLOOR GIRDER 1 1 � Job Reference (optional) Al MUUr I MUb=b, rUM I r1rMUr, M J4a9o, riyan opencer nun: i.ou s Nov Za eui a rnni: /.aUU s NOV 40 [UlA MI ex Inausines, IfIC. bal Ac Zl UTATU ful rage 7 ID:OkilyUUrWFoYXN4BLICLJhy732V-g6e)3PDBXIBTffxy_3WJWIr3 61kPTEK1EOL2y6ozr 2-6.0 L 2-6-8 7 34 11 5x6 = 3x6 11 Scale =1:11.1 1 1 1 2 3x6 = 1.5x4 II 5 5.8-0 3 4 3x6 = LOADING (psf) SPACING 0-6 0 CSI DEFL - in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.93 Vert(LL) -0.02 5 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.60 Vert(TL) -0.05 5 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.57 Horz(TL) 0.02 4 n/a n/a BCDL 10.0 Code FB0201 O/TP12007 (Matrix), Weight: 42 lb FT - 0%F, 0 %E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 5-8-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 6=1173/0-3-8 (min. 0-1-8), 4=1249/Mecha l ical FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-262/0, 3-4--352/0 BOT CHORD 5-6=0/1845, 4-5=0/1845 WEBS 2-4=-2047/0, 2-6=-2053/0 NOTES 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Refer to girder(s) for truss to truss connections. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model iwas used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc andlfastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 749 lb down at 1-6-12, and 749 lb down at 3-0.12, and 749 lb down at 4-4-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1,00 Uniform Loads (plf) Vert: 4-6--5, 1-3=-27 Concentrated Loads (lb) Vert: 2=-749(F) 7= 749(F) 8=-749(F) Julius Lee, P.E. ;934869 1109 Coastal Bay Boynton Beach, FL 33435 Job Truss Iruss Type y ply 57380 F20 Floor 1 1 Job, Reference (optional) n nwr t nuaaw, rvn i ncnuc, rc ...... ny— aP.—.' nm I. nuuu a tvuv m cu u root. auuu a rvuv co cu m moan muuanaa, um. out uuu c t twau:uu zu �� raga ID:QZy`UUrWFoYXN4BL1(�Jhy732V-g6eJ3PDBXu1'9 xy_3WJWIrEN69aPbCit1EOL2y6ozr 2-0.11 1-2-8 1.2-0 3x3 = 3x6 11 3x6 I I Scale-1:11.0 1 3x3 11 2 3 4 3x3 = Q, 6 5 0' 3x3 = 3x6 = 2-3-11 4-11-3 2-3-11 %2-11 2-7-8 0-3-8 LOADING (psf) SPACING 1-4-0 CSI DEFL in (loc)' I/de0 Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.20 Vert(LL) -0.00 6 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.10 Vert(TL) -0.01 5-6 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.06 Horz(TL) 0.00 4 - n/a n/a BCDL 10.0 Code FBC201 O/fP12007 (Matrix) Weight: 33 lb FT = O%F, O%E LUMBER BRACING TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 5-2-11 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 7=206/0-6-14 (min. 0-1-8), 4=206/0-3-0 (min. 0-1.8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less exlept when shown. NOTES 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. - 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E. *34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I toss I toss I ype Qty ply 57380 FT1 FLOOR GIRDER 1 3 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: 7.500 s Nov 26 2013 Print: 7.500 a Nov 26 2013 Wek Industries Inc. Sal Dec 21 08:50:00 2013 Page 1 ID:OkilyUUrWFoYXN4BLIQ.Jhy732V-g6ej3PDBXIBixy_3WJWIr7g64XPSiif1 EOL2y6ozr 2-8.4 Scale-1:13.0 1 2x4 11 1 2 4x8 = 48 = 5 2x4 11 3.5-4 32x4 II 4x8 = LOADING (psf) SPACING 0-4-0 CS' DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.68 Vert(LL) -0.05 5 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.42 Vert(TL) -0.10 5 >742 360 BCLL 0.0 Rep Stress Incr NO WB 0.61 Horz(TL) 0.01 4 n/a n/a BCDL 10.0 - Code FBC2010/TP12007 (Ma flx) — Weight: 113 Ib FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-10-8 oc purlins, BOT CHORD 2x6 SP 240OF 2.0E except end verticals. WEBS 2x4 SP No.3 *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. W1: 2x8 SP No.2 REACTIONS (lb/size) 6=4232/0-2-0 (min. 0-1-8), 4=4232/0-2-0 (min. 0-1-8) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-975/013-4=-975/0 BOT CHORD 5-6=0/7684, 4-5=0l7684 WEBS 2-4=-7926/0, 2-6=-7926/0, 2-5=0/1201 NOTES 1) 3-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-01oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9.0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6, 4. 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 4-6=-61 1 (F=-304, B=-304), 1-3=-738 Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I russ Type y 57380 FTG1 Floor Girder 1 2 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: 7.500 s Nov 26 2013 Print: 7.500 s Nov 26 2013 MTek Industries, Inc. Sat Dec 21 08S0:00 2013 Page 1 ID:akilyUUrWFoYXN4BLILt_Jhy732V-g6ej3PDBXIBTifxy_3WJWIr9n62GPXoif1 EOL2y6ozr 2.1-4 2.6-0 L 2.0-0 1.11-10 2-4-6 1-6-1 Scale-1:33.5 2x4 11 3x4 = I 3x4 — 1.5x4 11 3x4 = 2x4 11 3 4 1 5 6 3x4 = 1.5x4 II 3x4 = 2x4 II 7 8. 9 10 W1 Bi j Li 112� W1 16 15 13 12 1 46 = 3x4 = 1.5x4 11 412 = 3x4 = 3x8 = 46 = 10-1-0 5-6-0 6 6 D 7 6 D, 9.11-12 1Dip-8 2a1-9 5-6-0 1-a0 1-aD 2.5-12 0-012 10.0-9 0.0.8 Plate Offsets (X,1): [11:0-2-0,0-2-0],[17:0-2-0,0.2-0] LOADING (psf) SPACING 1-4-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.0616-17 >999 480 MT20 244/190 TCDL 15.0 • Lumber Increase 1.00' BC 0.56 Vert(TL) -0.11 16-17 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.28 Horz(TL) 0.02 11 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 195 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4SPNo.3'Except* WI: 2x8 SP No 2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. I REACTIONS (lb/size) 11=969/0-3-8 (min. 0-1-8), 17-968/0-3-8 (min. 0.1-8), 14=2391/0-3-8 (min, 0-1-8) Max Grav 11 =992(LC 7), 17=1 020(LC 3), 14-2391(LC 1) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1648/0, 3-4=-1648/0, 4-5=0/866, 5-6=0/866, 6-7=0/866, 7-8=-1894/0, 8-9=-1894/0 BOT CHORD 16-17=0/1551, 15-16=0/1648, 14-15=0/1648, 13-14=0/1262, 12-13=0/1262, 11-12=0/1233 WEBS 4-15=0/316, 6-14=-521/0, 2-17--1615/0, 4-14=-2414/0, 7-14=-2088/0, 7-12=0/793, 8-12=-553/0, 9-12=0/727, 9-11=-1417/0 NOTES 1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 -1 row at 0.9-0 oc. Webs connected as follows: 2x4 -1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase-1.00 Uniform Loads (plf) Vert: 11-17=-13, 1-10=-208 Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I cuss I ype 573e0 FTG2 FLOOR 1 2 Job Reference (optional) Al hUUt- I hUJbtb, r'Uh I rIChlit, rL a4s4b, hyan APencer nun: /.Duu s Nov zo zui a rnnr. aouu s Nov zo zu,a mn uK mnusines, inc. oai Uec Z, ca:OV:u1 eul ra ID:QldlyUUrWFoYXN4BLICLJhy732V-IJCSGIEgH3JJKpW8Yn2Y3zOPpWRf871suh z\7ya(se i1q 2-9-8 2-6-0 Scale-1:18.2 2x4 II 3x4 1.5x4 II 2x4 II 2 3 4 3x4 = 5 1 W1 W2 W3 W3 W1 1Lj 9 3x6 = 8 7 6 3x4 = 1.5x4 11 3x6 = 0-6.4 I 9-i-1 q1.8 0 6 4 9-2-5 0. Plate Offsets (X,Y): [6:0-2-0,0-1-8],[9:0-2-0,0-1-8] 1 LOADING (psf) SPACING 1-4-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TO 0.22 Vert(LL) -0.03 8-9 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.36 Vert(TL) -0.06 8-9 >999 360 BOLL 0.0 Rep Stress Incr NO WB 0.22 Horz(TL) 0.02 6 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:100 Ib FT - 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. W1: 2x8 SP No.2 REACTIONS (lb/size) 9=1023/Mechanical, 6=1023/Mechanical FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less exlcept when shown. TOP CHORD 1-9--318/015-6--309/0, 2-3=-1803/0, 3-4— 1803/0 BOT CHORD 8-9=0/1807, 7-8=0/1803, 6-7=0/1803 WEBS 2-9=-1797/0, 4-6=-1822/0, 2-8=-197/275 NOTES 1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 6c, 2x4 - 1, row at 0-9-0 oc. Bottom chords connected as follows: 2x4 -1 row at 0-9-0 oc. Webs connected as follows: 2x4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced'floor live loads have been considered for this design. 4) Plates checked for a plus or minus 0 degree rotation about Its center. 5) Refer to girder(s) for truss to truss connections. 6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 8)' CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 6-9=-13, 1-5=-206,_. Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I toss I toss Type y y 573BO FTP1 Flat 1 1 Job Reference(optional)_ Ni nuur i rnussra, run i rienue, rL J484b, nyan Spencer nun: r.aoo a NOV Zb Z01J runt: 1.t1[)0 a NOV ?b ZO1J Mi l eK Inaustnes, Inc. Sat uec 21 oato 12013 Page 1 ID:OkityUUrWFoYXN4BLl0_Jhy732V-IJC5GIEgH3JJKpW8Yn2Y3zOSD W W582Rsuh_ztVy6ozq 0 6 14 0.6-14 0.0-0 1-6-9 1-6.9 0-3-7 1.10.0 Scale =1:5.8 m 6 0-0.0 1 6 9 1-6-9 _Plate Offsets (X,Y): [2:0-3-0,0-0-0),[3:0-3-0,0-0-8) LOADING (psf) SPACING 1-4-0 CSI I DEFL in (loo) I/deft L/d PLATES. GRIP TCLL 40.0 Plates Increase • 1.00 TC 0.06 Vert(LL) -0.00 5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.01 Vert(rl-) -0.00 5 >999 240, BCLL 0.0 Rep Stress Mor YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 8 lb FT = 0% LUMBER TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING TOP CHORD Structural wood sheathing directly applied or 1-6-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. REACTIONS (lb/size) 1=69/0-5-14 (min. 0-1-8), 3-74/0-2-15 (min. 0-1-8) Max Upliftl=-40(LC 8), 3=-47(LC 8) FORCES (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=170mph (3 second gust) Vasd=132mph; 7CDL=5.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOIj=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 40 lb uplift at joint 1 and 47 lb uplift at joint 3. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I cuss Type Qty y 57380 FTP2 Flat 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34945, Ryan Spencer -D-6-14 . _ 0-0-0 Run: 7.590 s Nov 25 2013 Print: 7.500 s Nov 26 2013 Mi IeK Incustne6 Inc. Sal Uec 21 00:50:02 2013 Page 1 ID:Ok➢yUUrWFoYXN4BLICLJhy732V-mVmTU5ES2NRAyy5L6UZnbAwYOwgTtUg 76LjXPxy6ozp 3.10-4 _ 4-1-11 1.5x4 11 I 1.5x4 11 0-D-0 3-10-4 3-1 D-4 Scale - 1:10.1 Plate Offsets (X,Y): [2:0-3-8,Edge], [3:0-3-8,Edge], [4:0-2-0,0-1-4], [5:0-2-0,0-0-12] LOADING (psf) SPACING 1-4-0 CSI 1 DEFL in (loc) I/dell Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.38 Vert(LL) 0.03 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.13 Vert(TL) 0.03 4-5 >999 240 MT20H 187/143 BCLL 0.0 ' Rep Stress incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC201 OfrPi2007 (Matrix-M) Weight:14 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-10-4 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=169/0-5-14 (min. 0-1-8), 3=175/0-2-15 (min. 0-1-8) Max Upliftl =-1 04(LC 8), 3=-113(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-5.Opsf; BCDL-5.0psf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL 1 1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 1 and 113 lb uplift at joint 3. 9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I russ I ype y 573e0 FTP3 . Flat 1 - 2 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34945, Ryan Spencer 040 2.11-3 Nun: /.t10u 6 NOV Zb Zulp rnm: /.DUU 6 rvov ZC ZU1.1MI IeK MOUemea, mc, Sai U8C Z7 uw6u:UZ Zu1J ra e 1 ID:QWIyUUrWFoYXN4BLICLJhy732V-mVmTU5ES2NRAyy5L6UZnbAwXNwgEtFN76L)XP ozp 2-11-3 pa i&: 5.10-5 3x4 11 1 3x4 11 2 3 T7 W1 W2 i 1 W3 W2 W1 Li B1 Scale-1:11.3 502 = 12x18 MT20H= 5x12 = 6 I 0 D 0 2 11.3 2-11-3 2-11-3 5-10.5 Plate Offsets (X Y): 14:0-5-8 0-3-0] [5:0-9-0,0-3-4],[6:0-5-8,0-3-0] 1 LOADING (psf)- SPACING 1-4-0 CSI DEFL in (]cc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.42 Vert(LL) 0..15 5 >430 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.79 Vert(TL) 0.13 5 >486 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr NO WB 0.98 Horz(TL) -0.04 4 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight: 58 lb FT - 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP M 30 WEBS 2x8 SP No.2 *Except* BOT CHORD W3: 2x6 SP No.2, W2: 2x4 SP No.2 REACTIONS (lb/size) 6=2228/Mechanical, 4=2228/Mechanical Structural wood sheathing directly applied or 5-10-5 cc purlins, except end verticals. Rigid ceiling directly applied or 4-4-13 cc bracing. Max Uplift6— 1448(LC 8), 4=-1448(LC 8) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-6— 185/279, 3-4=-185/279 BOT CHORD 5-6=-10543/592214-5=-10543/5922 WEBS 2-5=-256/229, 2-6=-6242/11113, 2-4=-6242/11113 NOTES 1) 2-ply truss to be connected together with 1 Od (0.131 "xW) nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x4 -1 row at 0-2-0 cc. Bottom chords connected as follows: 2x4 -1 row at 0-9-0 cc. Webs connected as follows: 2x6 - 2 rows staggered at 0-9-0 cc, 2x4 -1 row at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-5.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) Plates checked for a plus or minus 0 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1448 lb uplift at joint 6 and 1448 lb uplift at joint 4. 11) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2083 lb down and 3679 lb up at 2-11-3, and 2083 lb down and 3679 lb up at 2-11-3 on top chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert:1-3=-73, 4-6=-13 Julius Lee, P.E. 934869 Continued on page 2 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I cuss Type LIt y y 57380 FTP3 Flat 1 2 Job Reference o tionai Hl MIJVr 1 %UbbCb, r•VM1 M=MUC, M a4`J4b, riyan Spencer LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 2=-4000(F=-2000, B=-2000) nun: /.buy s NDV Zb ZUl J rnni: /.ODU a NDV Zb Zul J MI ieK InOuainea, Inc. bat Ueo zi utmumz Zu13 rage 2 ID:OkilyUUrWFoYXN4BUQ Jhy732V-mVmTU5ES2NRAyy5L6UZnbAwXNwgEtFN76L)XPX .p Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I cuss I ype y 57380 FTP4 Flat 1 1 Job Reference (optional) nwara, con, ­.. r....... nyan aP.—, -D-6.14 _ ..0-0-0 ID.QkilyUUrWFoYXN4BLIC_Jhy732V-mVmTl15ES2NRAyy5L6UZnbAwSXwmHtSY?6LjXPxy&-p Scale =1:14.8 0.0.0 6 1-15 &1-15 Plate Offsets (X,Y): [2:0-3-8,0-2-0], [3:0-3-8,Edge] I LOADING (psf) SPACING 1-4-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TO 0.73 Vert(LL) 0.16 4-5 >475 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.40 Vert(TL) 0.14 4-5 >542 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.14 Horz(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC201 D/TP12007 (Matrix-M) Weight: 30 lb FT - 0% LUMBER BRACING TOP CHORD" 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.2'Except' BOT CHORD Rigid ceiling directly applied or 6-7-7 oc bracing. W2: 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=269/0-5-14 (min. 0-1-8), 3=275/0-2-15 (min. 0-1-8) Max Upliftl— 169(LC 8), 3=-178(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3--164/311, 3-4=-259/90 BOT CHORD 4-5=-592/360 WEBS 2-4=-198/284 NOTES I 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or -minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 169 lb uplift at joint 1 and 178 lb uplift at joint 3. 9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I cuss I ype y y 57380 FTP5 Flat 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, R. 34946, Ryan Spencei Run: 7.500s Nov 26 2013 Print: 7.500 s Nov 26 2013 MiTek Industries, Inc. Sat Dec 21 0850:03 2013 Page 1 ID:OkilyUUrWFoYXN4BLICLJhy732V-EhKrhRF4pgZ1 Z6gXfC408OTaSKApcg58L4T4xNy6ozo 4-2.13 1 48 = 12x14 = Scale-1:19.3 1' 0 D-D-O 4-2-13 4 2-13 4.2.13 8.5-10 Plate Offsets_ (X,Y): 15:Edge,0-8-121, [7:Edge,0-8-12] LOADING (psi) SPACING 1-4-0 CSI DEFL in (loc) Well L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.91 Vert(LL) 0.13 6-7 >820 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.19 Vert(TL) 0.11 6-7 >936 240 BCLL 0.0 Rep Stress Incr YES WB 0.50 Horz(TL) 0.02 4 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix! M) Weight: 40 lb FT - 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-5-10 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 8-2-13 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=369/0-5-14 (min. 0-1-8), 4=375/0-2-15 (min: (0-1-8) Max Upliftl=-234(LC 8), 4=-243(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-974/1656, 3-4=-974/1656 BOT CHORD 6-7= 464/285 WEBS 3-6= 326/300, 2-6=-1219/704, 4.6=-1498/880 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.160 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joints) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 234 lb uplift at joint 1 and 243 lb uplift at joint 4. - 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I russ Type Y 57380 FTP6 Flat 1 1 Job Reference (optional) At ROOF TRUSSES, FORT PIERCE, FL 34845, Ryan Spencer 1.5x4 II 2 46 11 1.5x4 11 8 4x8 = D-0-0 L 5-1Pit 5 Run: 7.500 a Nov 26 2013 Print: 7.500 s Nov 26 2013 Welt Industries, Inc. Sat Dec 21 0850:03 2013 Page 1 ID:OkilyUUrWFoYXN4BLICLJhy732V-EhKrhRF4pgZ1 Z6gXfC408OTgzK5dcme8L?T4xNy6ozo 5-10-15 44 = 7 44 = 4-10.6 5x6 = 1.5x4 II 10-9.5 J 1.0-12 Scale-1:21.3 c lop l!4 O Plate Offsets (X,Y): [5:0-2-8,0-2-12) 1 LOADING (psf) SPACING 1-4-0 CSI I DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.56 Vert(LL) 0.19 6-7 >602 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 6.46 Vert(TL) 0.17 6-7 >692 240 BCLL 0.0 ' Rep Stress Incr YES WB 6.72 Horz(TL) 0.01 5 n/a n/a BCDL 10.0 Code FBC2010frP12007 (MatrixM) Weight: 51 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-9.6 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 4-5-1 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=-205/0-5-14 (min. 0-1-8), 5=376/0-2-15 (min. 0-1-8), 8=' 73/0-6-15 (min. 0-1-8) Max Upliftl=-205(LC 1), 5=-245(LC 8), 8— 482(L(,- 8) 1 Max Gravl=146(LC 8), 5=376(LC 1), 8=773(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-254/171, 4-5=-1013/1631 BOTCHORD 7-8=-1631/1013 1 WEBS 5-7=-1658/1030, 3-8=-269/205, 2-8=-235/349, 4-8=-1167/1887 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-5.0psf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever eft and right exposed ; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 1, 245 lb uplift at joint 5 and 482 lb uplift at joint 8. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I russ Type I LIEy y 57380 FTP7 Flat 1 1 �J.b.Ref.rence (optional) Ai RWF TRUSSES, rune RERut, FL 34946, Ryan Spencer Run: r.auu s Nov zo zuiS rnni: i.auu s Nov as zuiS muex inaustnes, inc. sai use zi ueau:oa zuia rage i ID:OkilyUUrWFoYXN4BLIQ.Jhy732V-IuuEvnGla huBGFJDvbFgbOtakTbLlllafCdLlq 6 .n a�a4 140.0 � 4.3 4 I 4-4-14 B-8 2 4.414 1307 3.4-7 4-3 Scale-1,25.5 1.5x4 11 4x8 = 3x6 11 2 44 = 3 4 5 � 1 m4 I� 6s. 9 7 6 1.5x4 11 8 1.5x4 11 4x4 = 4x8 = LOADING (psf) SPACING 1-4-0 CSI I I DEFL in (loc) I/dell Ud PLATES- GRIP TCLL 40.0 Plates Increase 1.00 TC 0." Vert(LL) 0.11 6-7 >990 360 MT20 2"/190 TCDL 15.0 Lumber Increase 1.00 BC d.35 Vert(TL) 0.09 6-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB d.44 Horz(TL) -0.00 5 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-�M) Weight: 62 Ito FT = 0% LUMBER I BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 5-2-6 oc bracing. MiTek recommends that Stabilizers and required cross I bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=106/0 5-14 (min. 0-1-8), 5=329/0 2 15 (min. 0 1 8), 8=708/0 6 15 (min. 0 1 8) Max Uplift1=-64(LC 8), 5— 215(LC 8), 8=-459(LC 8) 1 FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-294/204, 3-4=-294/204, 5-6=-362/174 BOT CHORD 7-8=-1159/75216-7=-1159/752 WEBS 2-8=-295/413, 3-8=-365/336, 4-8=-974/1481, 4-7— 264/I �01, 4-6= 649/1000 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.0psf; BCDL-5.0psf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1 60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Plates checked for a plus or minus 0 degree rotation about its center. ) 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of.withstanding 64 lb uplift at joint 1, 215 Ito uplift at joint 5 and 459 lb uplift at joint 8. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 Job Truss I cuss Type I I y 57380 FTP8 FLOOR 1 1 Job Reference (optional) n i nwr , nuoaco, ran i --, — uroYp, ny— opencc� nun./AUub.-Gp.... rI"Il. /.pYp 6 nW ap cp i'Z "NYbWCS,""''GI"' G I up"I'u";ei ID:OkilyUUrWFoYXN4BLI�Jhy732V-iuuEvnGla_huBGF)DvbFgbOlakPCLELIafrdUgy ozn 15-8-3 Scale-1:28.7 0.0.0 5-2-3 5-2-3 5-0.7 10.2.9 5-2-3 15-4-12 Plate Offsets (X,Y): [2:0-3-8,0-3-4],[6:0-2-8,0-3-01, [8:0-3-0,0-1-8],[9:0-4-0,0-1-12] LOADING (psf) SPACING 1-4-0 CSI I DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.95 Vert(LL) -0.25 8-9 >760 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.63 Vert(TL) -0.48 8-9 >390 360 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES WB d.69 Horz(TL) -0.06 6 n/a n/a BCDL 10.0 Code FBC2010lfP12007 (Matrix1M) Weight: 86Ito FT-0% LUMBER BRACING TOP CHORD 2x4 SP M 30 I TOP CHORD Structural wood sheathing directly applied or 3-10-14 oc puriins, BOT CHORD 2x4 SP M 30 except end verticals. WEBS 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. W3: 2x4 SP No.3 MiTek recommends that Stabilizers and required cross OTHERS 2x4 SP M 30 bracing be installed during truss erection, in accordance with LBR SCAB 1-4 2x4 SP M 30 one side Stabilizer Installation Guide. REACTIONS (lb/size) 1=669/0-5-14 (min. 0-1-8), 6=675/0-2-15 (min! 0-1-8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11— 2696/0, 3-11=-2696/0, 3-12= 2696/0, 4-12=-2696/0, 4-5=-2696/0, 5-6--2649/0 BOT CHORD 9-10=0/519, 8-9=0/2649 WEBS 2-9=0/2210, 3-9=-348/0, 5-8=-380/0, 6-8=0/2456 NOTES 1) Attached 9-4-0 scab Ito 4, front face(s) 2x4 SP M 30 with 1 row(s) off 10d (0.131 "x3") nails spaced 9" o.c.except :starting at 4-9-1 from end at joint 1, nail 1 row(s) at 7" o.c. for 2-0-0; starting at 7-4-0 from end at joint 1, nail 1 row(s) at 7" o.c. for 2-0-0. 2) All plates are MT20 plates unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job Truss cuss Type y 57380 FTP9 FLOOR 1 1 Job Reference (optional) Hl ROOF i RDSSCS, FORT FERCE, FL 34946, Ryan Spencer nun: i.ouu s Nov zo zu io Fnni: 7.500 s Nov co cu is m5ek mcusmes inc, oai Dec 21 ua:Su:uv zui a ra e i ID: OkilyUUrWFoYXN4BLIO_Jhy732V-IuuEvnGia huBG�FJDvbFgbOppkT9LldlafC'dUq ozn 0 14 o-ao 3.4-2 5 4 2 7-9-10 11-8-3 15-3-12 17-8-7 17-11-14 L4 3.4.2 2-0.0 2-5.8 3.10.9 3-7-9 2.4-11 O 3:)7 Scale-1:34.8 1.5x4 11 4x4 = 1.Sx4 11 1 4x8 = 5x6 = 2x4 11 30 = 0.0.0 _ , _ 34-2 5.4-2 2-6 13 7.10-15 3-9-511.8.3 3.7.9 15-3-12 2-4-11 17494 m I� LOADING (psf) SPACING 1-4-0 CSI I DEFL in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.68 Vert(LL)-0.0511-12 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.38 Vert(TL) -0.09 11-12 >999 360 BCLL 0.0 Rep Stress Incr YES WB 6.42 Horz(TL) -0.02 9 n/a n/a — BCDL 10.0 Code FBC201 O/TPI2007 (Matrix m) Weight: 82 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-6-11 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. Except: WEBS 2x4 SP No.3 *Except* 10-0-0 oc bracing: 7-8 W5: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=277/0-5-14 (min. 0-1-8), 9=380/0-3-0 (min. 0-1 -8), 13=887/0-4-0 (min. 0-1-8) Max Grav1=302(LC 3), 9=390(LC 4), 13=887(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-521/0, 3-4=-521/0, 4-5=0/416, 5-6=0/334, 6-7=-946/0, 9-10=0/327 BOT CHORD 14-15=0/521, 13-14-0/521, 12-13=0/941, 11-12=0/901 ,� 10-11=0/505 WEBS 5-13=-271/0, 8-10=-550/0, 6-13=-1230/0, 4-13=-853/0, 2-15_ 66/315 NOTES 1) Unbalanced floor live loads have been considered for thisdesign. 2) Plates checked for a plus or minus 0 degree rotation about its center.) 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 Jot) Russ I n1S5 Type y 57380 FrP10 FLOOR I 3 1 Job Reference (optional) hi nuur i nuaa=o, run i ri=nu=, r� jvvgo, Ryan OF—r nun: vv co 1— ,. 1 e - , - ID:OkilyUUrWFoYXN4BLlCLJhy732V-A4Sc67HKLIplp6Z; BUDpY0m7n84jzRol;B Gy6ozm a37aa0 2.7-6 %%115-2.110.0 7.2111 2.613 9-9-8 5.1.2 14-10-10 �6 1eil19-1a7 a3W7 -2-7.6 2.5-2 0 2r3 7 3x6 II 3x4 = 1.5x4 II 3x4 = 44 = 1 2 3 41 5 m 15 14 13 3x4 = 3x4 = 1.5z4 II 3x4 = Scale-1:38.1 3x6 = 5x6 = 3x8 = 7 8 I� Io N 11 10 9 3x4 = 400 = 1.5x4 11 aao 5-2-11 5.2-11 2•a0 7 2 1 2.6-13 9" 5 1.2 14-1 a10 4.8.6 19-7.0 Plate Offsets (X Y): [1:0-3-0 0-0-0][6:0-3-4,0-1-81,[7:0-1-8,0-1-8],[8:0-2-8 0-2-121 LOADING (psf) SPACING 1-4-0 CSI, I DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC Q.54 Vert(LL) -0.0614-15 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.46 Vert(TL) -0.1214-15 >976 360 BCLL 0.0 Rep Stress Incr YES WB 6.54 Horz(TL) -0.03 8 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 90 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-2 oc purlins, BOT CHORD 2x4 SP No.2 except and verticals. WEBS 2x4 SP No.3 *Except* BOT CHORD _Rigid ceiling directly applied or 10-0-0 oc bracing, Except: W5: 2x6 SP No.2 6-0-0 oc bracing:10-12. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=375/0.2-15 (min. 0-1-8), 8=375/0-3.0 (min. 0-1-8). 12=922/0-4-0 (min. 0-1-8) Max Grav1=387(LC 3), 8=390(LC 4), 12=922(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-15=0/303, 2-3=-801/0, 3-4=-801/0, 5-6=-1031/0, 6-10=-332/0, 7-8=-762/0 BOT CHORD 14-15=0/772, 13-14=0/801, 12-13=0/801 WEBS 4-12=-1064/0, 5-12=-551 /0, 5-10=0/1138, 2-15=-745/018-10=0/708 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center! 3) Provide mechanical connection (by others) of truss to bearing plate at joint(s)1. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 oruss cuss type _ y y 57380 �HIJ3 Diagonal Hip Girder I 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0.0.0 3x6 II 0-0-0 Run: 7.500 s Nov 26 2013 Print: 7.500 a Nov 26 2013 MTek Industries, Inc. Sat Dec 21 0850:05 2013 Page 1 ID:QkilyUUrWFoYXN4BLIQ Jhy732V-A4Sc67HKLlplpQgvnd6UDpY3g7pU4rQRoIyBOGy6ozm _ 4.10.9 4.10.9 Scale-1:10.8 LOADING (psf) SPACING 2-0-0 CSI I DEFL in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.35 Vert(LL) 0.05 4-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.37 Vert(TL) 0.04 4-9 >999 240 BCLL 0.0 Rep Stress Incr . NO WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0, Code FBC201O)TP12007 (Matdx-'M) Weight:16 lb FT= 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-10-9 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE MiTek recommends that Stabilizers and required cross Left: 2x4 SP No.3 bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=136/Mechanical, 1=333/0-9-4 (min. 0-1-8), _Max Horz 1=103(LC 8) Max Uplift2— 102(LC 8), 1— 144(LC 8), 4=-13(LC 8) Max Grav2=136(LC 1),1=333(LC 1), 4=75(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.0psf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1 ,60 plate grip DOL=1.60 2) This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration. 3) Plates checked for a plus or minus 0 degree rotation about its center. 1 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 102 lb uplift at joint 2, 144 lb uplift at joint 1 and 13 lb uplift at joint 4. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 Job I russ I russ I ype y 57380 HJ7 DIAGONAL HIP GIRDER 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer 0-0-0 7-1(61 d Run: 7.500 s Nov 26 2013 Print: 7.500 s Nov 25 2013 MTek Industries, Inc. Sat Dec 21 0850:06 2013 Page 1 ID:QkilyUUrWFoYXN4BLICLJhy732V-eGO JTHy6bxcQaP6LKdjm057gX1up5hblyhkYiy6ozl 7-10.14 s a 1a 11.3-12 a to 15-4-0 Scale-1:25.9 1.5x4 II 4 5 2.00 12 3x6 = 3 1.5x4 11 2 1 4 1 1 vi Ll 3x6 = 8 3x4 = 7 3x8 11 4x8 11 6 46 II 0 0 0 2 3 10 I 11.3-12 15.4-0 2.3-10 9-D-3 4-0-4 Plate Offsets (X,Y): [1:0.6.5,0-0-1],[1:0-0-6,Edge],[1:0.0-2,2-9-7],[4:0-2-8,0-0-12],[7:0-3-4,0-2-0] LOADING (psf) SPACING 1-0-0 CSI J.78 DEFL in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC Vert(LL) -0.19 7-8 >966 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 6.81 Vert(TL) -0.52 7-8 >349 240 BCLL - 0.0 Rep Stress Incr NO WB O 90 HOrz(TL) 0.05 7 n/a n/a BCDL 10.0 Code FBC2010/1'PI2007 (Matrix -IA) Weight: 65 lb FT = 0% LUMBER TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Lett: 2x4 SP No.3 REACTIONS (lb/size) 1=1026/1-6-10 (min. 0-1-8), 7=1837/Mechanical Max Horz 1=94(LC 4) Max Upliftl=-583(LC 4), 7=-1226(LC 4) BRACING TOP CHORD Structural wood sheathing directly applied or 3-8-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-4-8 oc bracing. FORCES (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-14=-1287/757, 1-15=-3278/1837, 15-16=-3239/1827, 2-16=-3208/1807, 2-17=-3249/1854, 3-17=-3186/1822 BOT CHORD 1-9=-779/1239, 1-20=-1860/3195, 20-21=-1860/3195, 8121— 1860/3195, 8.22=-1364/2106, 22-23=-1364/2106, 23-24=-1364/2106, 7-24=-1364/2106 WEBS 2-8=-291/279, 4-7=-679/508, 3-8=-568/1250, 3-7=-2361/1530 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide metal plate or equivalent at bearing(s) 7 to support reaction shown. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 583 lb uplift at joint 1 and 1226 lb uplift at joint 7. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 30 lb down and 41 lb up at 2-8-10, 59 lb down and 64 lb up at 5-0-7, 26 lb down and 39 lb up at 5-0-6, 99 lb down and 96 lb up at 7-4-2, 71 lb down and 77 Ib up at 7-4-2, 139 lbdown and 127 Ib up at 9-7-14, 120 lb down and 114 lb up at 9-7-13, 178 lb down and 159 lb up at 11-11-9, 168 Ib down and 150 Ib up at 11-11-9, and 224 Ib down and 194 Ib up at 14-3-4, and 588 Ib down and 444 Ib up at 14-3-4 on top chord, and 33 lbdown and 14 Ib up at 5-0-7, 15 Ib down and 16 Ib up at 5-0.6, 50 Ib down and 10 Ib up at 7-4-2, 37 Ib down and 18 lb up at 7-4-2, 68 lb down and 6 lb up at 9-7-14, 61 lb down and 19 lb up at 9-7-13, 85 lb down at 11-11-9, 85 lb down and 20 Ib up at 11-11-9, and t01 Ib down at 14-3-4, and 238 Ib down and 275 Ib up at 14-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Julius Lee, P.E. #34869 Continued on page 2 1109 Coastal Bay Boynton Beach, FL 33435 job I russ I ruse I ype Lily Fly 57380 HJ7 I DIAGONAL HIP GIRDER 1 1 I Job Reference (optional) Al ROOF TRUSSES, FORT PIEROE, FL 34946, Ryan Spencer Hun: r.ouu a rvov zo zu» rnni: r.ouu s Nov zo zui a mi i eK mousmes, inc. oa[ Liec z j uo:ou:uo zu i a rage z ID:QIdIyUUrWFoYXN4BLII] Jhy732V-eGOJTHy6b.;&P6LKdjm057gX1up5hblyhkYiy6ozl LOAD CASES) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-45, 4-5— 15, 6-9=-10 Concentrated Loads (lb) Vert: 14=-24(F)15= 77(F=-59, B=-18) 16=-170(F= 99, B=-71)17= 259(F=-139, B=-120)18=-346(F=-178, B=-168) 19=-812(F=-224, B=-588) 20=48(F=-33, B=-15) 21=-80(F=-43, B=-37) 22=-109(F=-52, B=-56) 23=-136(F_ 61, B=-74) 24=33(F=-68, B=101) I I Julius Lee,P.E #34869 1109 Coastal Bay Boynton Beach, FL 33435 JOD I russ russ I ype y 57380 J2 Jack -Open i 1 1 . Job Reference o tional AI nV ,,nUODCD, rVn rICRVC,-0 .,ny—ONO,I 0.0.0 0 ID:OkilyUUrWFoYXN4BLICJhy732V-e&0 JTHy66xc6a06LKdjmO5J2XDvplgb1yhkry6ozl 4 3x6 11 2-0.14 Scale -1:7.5 0.0.0 2.0-14 2.0-14 Plate Offsets (X Y)• [1.0-2-14 0-0-10] [1:0-1-41-3-4] LOADING (psf) SPACING 2-0-0 CSI I DEFL in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.06 Vert(LL) -0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.04 Vert(TL) -0.00 6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 61.00 Horz(TL) -0.00 1 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-IM) Weight: 8 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-14 oc pur ins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE MiTek recommends that Stabilizers and required cross Left: 2x4 SP No.3 bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=19/Mechanical, 1=194/0-8-0 (min. 0-1-8), 5=10/Mechanical Max Horz 1=51(LC 8) Max Uplift2=-29(LC 8),1=-77(LC 8), 5=-6(LC 8) Max Grav2=19(LC 1), 1=194(LC 1). 5=15(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES j 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about Its center. 3) This truss has been designed for a 10:0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 29 lb uplift at joint 2, 77 lb uplift at joint 1 and 6 lb uplift at joint 5. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 1109 Coastal Bay Boynton Beach, FL 33435 oruss russ Type y 57380 JIB Jack -Open 1 1 Job Reference (optional) A7 muur i musseb, run i riemum, rL Oaawo, myan open—, 0-0-0 1 ��ID:OkilyUUrWFoYXN4BLIG1_Jhy732V-7SaMXplatv3T2k_Iu18ylEeNgxRaYlwkGcRl48y�ozk 5-6-7 Scale-1:12.9 US 11 4 0.0.0 5.6-7 5-6-7 , Plate Offsets (X Y)• [1.0-2-14 0-0-10] [1:0-0-4 Edge] LOADING (psf) SPACING 2-0.0 i CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 6.50 Vert(LL) 0.10 5-10 >664 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.52 Vert(TL) 0.08 5-10 >805 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.02 2 n/a n/a BCDL 10.0 Code FBC201 orrP12007 (MatrixM) Weight: 18Ib FT-0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-6-7 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0.oc bracing. WEDGE MiTek recommends that Stabilizers and required cross Left: 2x4 SP No.3 bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=174/Mechanical, 1=355/0-8-0 (min. 0-1-8), 5=75/Mechanical Max Horz 1=137(LC 8) Max Uplift2— 140(LC 8), 1=-146(LC 8), 5=-13(LC 8) Max Grav2=174(LC 1), 1=355(LC 1), 5=91(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BOT CHORD 1-6--250/136 NOTES 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 140 lb uplift at joint 2, 146 lb uplift at joint 1 and 13 lb uplift at joint 5. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435 o russ russ ype y 57380 J9 Jack -Partial 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946, Ryan Spencer Run: 7.500 s Nov 26 2013 Print: 7.500 a Nov 26 2013 MTek Industries, Inc. Sat Dec 21 0850:07 2013 Pag¢e 1 ID:OkilyUUrWFoYXN4BUC Jhy732V-7SaMXplatv3T2k Iu18ylEeOTxS1YhnkGcR148;gzk 0-0-0 411-11 4.11.11 4 0 5 9-0-0 3x4 11 Scale a 1:19.8 _Plate Offsets MY): [1:0-1-4,1-3-4], [1:0.2-14,0-0.2], [3:0-2-13,0-0-8], [6:0-1-8,0-1-8] LOADING (psf) SPACING 2-0=0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL - 0.0 Plates Increase 1.25 TIC 0.40 Vert(LL) -0.09 6-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.49 Vert(TL) 70.22 6-12 >466 240 BCLL 0.0 Rep Stress Incr YES WB 0.27 Horz(TL) -0.01 6 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 39 lb FT - 0% LUMBER TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-5-13 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 6=343/Mechanical, 3=118/Mechanical,1=532/0-8-0 (min. 0-1-8) Max Horz 1=224(LC 8) Max Uplift6=-189(LC 8), 3— 86(LC 8), 1=-217(LC 8) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-1=-303/211, 1-2--687/569 BOTCHORD 1-8=-473/298, 1-6=-819/719 WEBS 2-6=-781/892 NOTES I 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 189 lb uplift at joint 6, 86 lb uplift at joint 3 and 217 lb uplift at joint 1. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. 934869 1109 Coastal Bay Boynton Beach, FL 33435