HomeMy WebLinkAboutEPL Display CardENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 79
The lower the EnergyPerformance Index, the more efficient the home.
10701 S Ocean Dr Lot 644, Jensen Beach, FL, 34957-
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
Windows"
Description
a. U-Factor:
Sgl, U=0.63
SHGC:
SHGC=0.33
b. U-Factor:
WA
SHGC:
c. U-Factor.
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. Floor over Garage
c. N/A
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1
1634.00 ft2
b. Concrete Block - Int Insul, Adjacent
R=4.1
90.00 ft2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Roof Deck (Unvented)
R=20.0
655.00 ft2
1184
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
232.71 ft2
11. Ducts
a. Sup: Level 2, Ret: Level 2, AH: Level 2
R ft2
6 236.8
ft2
12. Cooling systems
kBtulhr
Efficiency
ft2
a. Central Unit
30.0 SEER:15.00
Insulation
R=0.0
R=30.0
R=
ft2
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
25.5 HSPF:8.20
1.500 ft.
0.330
Area
14. Hot water systems
a. Electric
Cap: 50 gallons
529.00 ft2
EF: 0.92
126.00 ft2
b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction throughAe above energy saving features which will be installed (or exceeded)
in this home before in I 'nspecti n. i9therwise, a new EPL Display Card will be completed
based on installed ' e o lia t t es.
Builder Signature: Date:
Address of New Home: . QC F-pN D 2W I, City/4 Zip: --SSP5c„� g9AC4{ I
--�A (,q ry 3 49s �
E
N
a
c
"Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
"Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software