Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HomecreteHomes_Kessell_Hutchinson_Island Builder Name: Homecrete Homes Street: 10701 S Ocean Dr Lot 644 Permit Office: City, State, Zip: Jensen Beach, FL , 34957- Permit Number. Owner: Kessel Residence Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL 1. New construction or existing New (From Plans) 9. Wall Types (1724.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1634.00 ft2 b. Concrete Block - Int Insul, Adjacent R=4.1 90.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (655.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 655.00 ft2 6. Conditioned floor area above grade (ft2) 1184 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(232.7 sqft.) Description Area a. Sup: Level 2, Ret: Level 2, AH: Level 2 6 236.8 a. U-Factor. Sgl, U=0.63 232.71 ft2 SHGC: SHGC=0.33 b. U-Factor: WA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: WA ft2 a. Electric Heat Pump 25.5 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.330 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (655.0 sqft.) Insulation Area EF:0.920 a. Slab -On -Grade Edge Insulation R=0.0 529.00 ft2 b. Conservation features b. Floor over Garage R=30.0 126.00 ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.197 Total Proposed Modified Loads: 26.22 PASS Total Standard Reference Loads: 33.18 I hereby certify that the plans and specifications covered by Review of the plans and 4TKE STq p, this calculation are in compliance w. a nda Energy specifications covered by this 1►� Code. calculation indicates compliance :ssr•; !r with the Florida Energy Code. ++,r„''%.•::�•'•; ,� O 3 PREPARED BY: DATE: 2 / 24 / 2014 Before construction is completed this building will be inspected for compliance with Section 553.908 c --�-' a , I hereby certify that thi 'ding, s signed, is in compliance Florida Statutes. ✓,� �� COD with the Florida Energ a WE'�� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 406.4.1 Compliant Software Page 1 of 6 PROJECT Title: HomecreteHomes_Kessell_H Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1184 Lot # Owner: Kessel Residence Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Homecrete Homes Rotate Angle: 0 Street: 10701 S Ocean Dr Lot Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Jensen Beach, Family Type: Single-family FL, 34957- New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_ST LUCIE_CO_INTL 2 39 90 70 75 722 58 Medium BLOCKS Number Name Area Volume 1 Block1 1184 10656 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Level 529 4761 Yes 1 0 1 Yes Yes Yes 2 Level 655 5895 No 0 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Level 1 86 ft 0 529 ft' -_- 1 0 0 2 Floor over Garage Level 2 ___ --__ 126 ft' 30 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 709 ft' 0 ft' Medium 0.96 No 0.9 No 20 22.6 ATTIC Area RBS IRCC V # Type Ventilation Vent Ratio (1 in) 1 Full attic Unvented 0 655 ft' N N 2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Unvented) Level 2 1 655 ft2 0.11 Wood WALLS Ornt Adjacent Space TO Wall Type1 Cavity Width Height Sheathing Framing Solar Below W Exterior Concrete Block - Int Insul Level 1 4.1 10 9 9 96.8 ft2 0 0.75 0 2 W Exterior Concrete Block - Int Insul Level 1 4.1 15 5 9 138.8 ft2 0 0.75 0 3 S Exterior Concrete Block - Int Insul Level 1 4.1 21 8 9 195.0 ft2 0 0.75 0 4 E Exterior Concrete Block - Int Insul Level 1 4.1 6 9 54.0 ft2 0 0.75 0 5 S Exterior Concrete Block - Int Insul Level 1 4.1 3 2 9 28.5 ft2 0 0.75 0 _ 6 E Garage Concrete Block - Int Insul Level 1 4.1 10 9 90.0 ft2 0 0.75 0 7 NE Exterior Concrete Block - Int Insul Level 1 4.1 27 9 243.0 ft2 0 0.75 0 8 W Exterior Concrete Block - Int Insul Level 2 4.1 26 2 8 209.3 ft2 0 0.75 0 9 S Exterior Concrete Block - Int Insul Level 2 4.1 33 7 8 268.7 ft2 0 0.75 0 10 E Exterior Concrete Block - Int Insul Level 2 4.1 14 4 8 114.7 ft2 0 0.75 0 11 NE Exterior Concrete Block - Int Insul Level 2 4.1 35 8 8 285.3 ft2 0 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood Level 1 None .46 3 6 8 20 111:2 WINDOWS Orientation shown is the entered. Proposed orientation. Overhang JWall # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 1 Metal Low-E Single Yes 0.63 0.33 20.0 111:2 1.5 1110 in 11 ft 0 in Drapes/blinds None 2 W 1 Metal Low-E Single Yes 0.63 0.33 12.8 ft2 1.5 ft 0 in 10 ft 0 in Drapes/blinds None 3 W 2 Metal Low-E Single Yes 0.63 0.33 38.5 1112 1.5 ft 0 in 10 ft 0 in Drapes/blinds None 4 S 3 Metal Low-E Single Yes 0.63 0.33 12.8 ft2 1.5 ft 0 In 10 ft 0 in Drapesiblinds None 5 S 3 Metal Low-E Single Yes 0.63 0.33 4.0 ft2 1.5 ft 0 in 10 ft 0 in Drapesiblinds None 6 NE 7 Metal Low-E Single Yes 0.63 0.33 25.7 111:2 1.5 ft 0 in 10 ft 0 in Drapes/blinds None 7 W 8 Metal Low-E Single Yes 0.63 0.33 64.2 ft2 1.5 ft 0 in 1 ft0 in Drapes/blinds None 8 S 9 Metal Low-E Single Yes 0.63 0.33 12.8 111:2 1.5 ft 0 in 1 ft0 in Drapes/blinds None 9 S 9 Metal Low-E Single Yes 0.63 0.33 8.0 ft2 1.5 ft 0 in 1 ft 0 in Drapes/blinds None 10 E 10 Metal Low-E Single Yes 0.63 0.33 4.0 ft2 1.5 It 0 in 1 ft 0 In Drapes/blinds None 11 E 10 Metal Low-E Single Yes 0.63 0.33 25.7 111:2 1.6 ft 0 in 1 ft0 in Drapesiblinds None 12 NE 11 Metal Low-E Single Yes 0.63 0.33 4.0 111:2 1.5 ft 0 in 1 ft 0 in Drapes/blinds None 2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wail Insulation 1 126ft' Oft' 31 ft 9ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 1552.8 85.25 160.32 .4617 8.7434 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 8.2 25.5 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15 30 kBtu/hr 900 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS V # - - Supply -- Location R-Value Area --- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Level 2 6 236.8 ft Level 2 59.2 ft' Default Leakage Level 2 (Default) (Default) 1 1 2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programablre Ceiling Fans: �Thermostart:�Y Heating [X] Jan [X] Feb r , [X] Mar Apr May Jun [)(] [ j Jul r�(] [ ] Aug [� [) Sep j Oct �,{ Oct Nov Nov Dec; Dec Venting [[[[ 1111 Jan [[[[ 1111 Feb [[[[�xxx]]]] Mar Jun [)Jul [[[ 1 Aug [)Sep �^� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 10701 S Ocean Dr Lot 644 PERMIT #: Jensen Beach, FL, 34957- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and. sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6