HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: HomecreteHomes_Kessell_Hutchinson_Island
Builder Name: Homecrete Homes
Street: 10701 S Ocean Dr Lot 644
Permit Office:
City, State, Zip: Jensen Beach, FL , 34957-
Permit Number.
Owner: Kessel Residence
Jurisdiction:
Design Location: FL, ST LUCIE_CO_INTL
1. New construction or existing New (From Plans)
9. Wall Types (1724.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1634.00 ft2
b. Concrete Block - Int Insul, Adjacent
R=4.1 90.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (655.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 655.00 ft2
6. Conditioned floor area above grade (ft2) 1184
b. N/A
R= ft2
c. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(232.7 sqft.) Description Area
a. Sup: Level 2, Ret: Level 2, AH: Level 2
6 236.8
a. U-Factor. Sgl, U=0.63 232.71 ft2
SHGC: SHGC=0.33
b. U-Factor: WA ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
30.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: WA ft2
a. Electric Heat Pump
25.5 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 1.500 ft.
Area Weighted Average SHGC: 0.330
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (655.0 sqft.) Insulation Area
EF:0.920
a. Slab -On -Grade Edge Insulation R=0.0 529.00 ft2
b. Conservation features
b. Floor over Garage R=30.0 126.00 ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.197 Total Proposed Modified Loads: 26.22
PASS
Total Standard Reference Loads: 33.18
I hereby certify that the plans and specifications covered by
Review of the plans and
4TKE STq p,
this calculation are in compliance w. a nda Energy
specifications covered by this
1►�
Code.
calculation indicates compliance
:ssr•;
!r
with the Florida Energy Code.
++,r„''%.•::�•'•; ,� O
3
PREPARED BY:
DATE: 2 / 24 / 2014
Before construction is completed
this building will be inspected for
compliance with Section 553.908
c --�-'
a
,
I hereby certify that thi 'ding, s signed, is in compliance
Florida Statutes.
✓,� ��
COD
with the Florida Energ a
WE'��
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 406.4.1 Compliant Software Page 1 of 6
PROJECT
Title:
HomecreteHomes_Kessell_H Bedrooms: 2
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1184
Lot #
Owner:
Kessel Residence
Total Stories: 2
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Homecrete Homes
Rotate Angle: 0
Street:
10701 S Ocean Dr Lot
Permit Office:
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
Jensen Beach,
Family Type:
Single-family
FL, 34957-
New/Existing:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST LUCIE_CO_INTL FL_ST LUCIE_CO_INTL 2 39 90
70
75 722
58
Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1184 10656
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
Level
529 4761 Yes 1
0
1 Yes
Yes
Yes
2
Level
655 5895 No 0
2
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio Level 1 86 ft 0
529 ft'
-_-
1 0
0
2 Floor over Garage
Level 2 ___ --__
126 ft'
30
1 0
0
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip
Metal 709 ft' 0 ft' Medium
0.96
No 0.9
No 20
22.6
ATTIC
Area
RBS IRCC
V #
Type
Ventilation Vent Ratio (1 in)
1
Full attic
Unvented 0
655 ft'
N N
2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
CEILING
#
Ceiling Type Space
R-Value
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) Level 2
1
655 ft2
0.11
Wood
WALLS
Ornt
Adjacent Space
TO Wall Type1
Cavity
Width
Height
Sheathing Framing Solar
Below
W
Exterior
Concrete Block - Int Insul Level 1
4.1
10
9 9
96.8 ft2
0 0.75
0
2 W
Exterior
Concrete Block - Int Insul Level 1
4.1
15
5 9
138.8 ft2
0 0.75
0
3 S
Exterior
Concrete Block - Int Insul Level 1
4.1
21
8 9
195.0 ft2
0 0.75
0
4 E
Exterior
Concrete Block - Int Insul Level 1
4.1
6
9
54.0 ft2
0 0.75
0
5 S
Exterior
Concrete Block - Int Insul Level 1
4.1
3
2 9
28.5 ft2
0 0.75
0
_ 6 E
Garage
Concrete Block - Int Insul Level 1
4.1
10
9
90.0 ft2
0 0.75
0
7 NE
Exterior
Concrete Block - Int Insul Level 1
4.1
27
9
243.0 ft2
0 0.75
0
8 W
Exterior
Concrete Block - Int Insul Level 2
4.1
26
2 8
209.3 ft2
0 0.75
0
9 S
Exterior
Concrete Block - Int Insul Level 2
4.1
33
7 8
268.7 ft2
0 0.75
0
10 E
Exterior
Concrete Block - Int Insul Level 2
4.1
14
4 8
114.7 ft2
0 0.75
0
11 NE
Exterior
Concrete Block - Int Insul Level 2
4.1
35
8 8
285.3 ft2
0 0.75
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value Width
Height
Area
Ft In
Ft In
1
E
Wood Level 1
None
.46
3
6 8
20 111:2
WINDOWS
Orientation shown is the entered. Proposed orientation.
Overhang
JWall
#
Omt ID
Frame Panes NFRC
U-Factor
SHGC
Area
Depth Separation
Int Shade
Screening
1
W 1
Metal Low-E Single Yes
0.63
0.33
20.0 111:2
1.5 1110 in 11 ft 0 in
Drapes/blinds
None
2
W 1
Metal Low-E Single Yes
0.63
0.33
12.8 ft2
1.5 ft 0 in 10 ft 0 in
Drapes/blinds
None
3
W 2
Metal Low-E Single Yes
0.63
0.33
38.5 1112
1.5 ft 0 in 10 ft 0 in
Drapes/blinds
None
4
S 3
Metal Low-E Single Yes
0.63
0.33
12.8 ft2
1.5 ft 0 In 10 ft 0 in
Drapesiblinds
None
5
S 3
Metal Low-E Single Yes
0.63
0.33
4.0 ft2
1.5 ft 0 in 10 ft 0 in
Drapesiblinds
None
6
NE 7
Metal Low-E Single Yes
0.63
0.33
25.7 111:2
1.5 ft 0 in 10 ft 0 in
Drapes/blinds
None
7
W 8
Metal Low-E Single Yes
0.63
0.33
64.2 ft2
1.5 ft 0 in 1 ft0 in
Drapes/blinds
None
8
S 9
Metal Low-E Single Yes
0.63
0.33
12.8 111:2
1.5 ft 0 in 1 ft0 in
Drapes/blinds
None
9
S 9
Metal Low-E Single Yes
0.63
0.33
8.0 ft2
1.5 ft 0 in 1 ft 0 in
Drapes/blinds
None
10
E 10
Metal Low-E Single Yes
0.63
0.33
4.0 ft2
1.5 It 0 in 1 ft 0 In
Drapes/blinds
None
11
E 10
Metal Low-E Single Yes
0.63
0.33
25.7 111:2
1.6 ft 0 in 1 ft0 in
Drapesiblinds
None
12
NE 11
Metal Low-E Single Yes
0.63
0.33
4.0 111:2
1.5 ft 0 in 1 ft 0 in
Drapes/blinds
None
2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wail Insulation
1
126ft'
Oft'
31 ft 9ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Best Guess
.0005
1552.8 85.25 160.32 .4617 8.7434
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Heat Pump
None
HSPF: 8.2 25.5 kBtulhr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
None
SEER: 15 30 kBtu/hr 900 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.92 50 gal 50 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft'
DUCTS
V #
- - Supply --
Location R-Value Area
--- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Level 2 6 236.8 ft
Level 2
59.2 ft' Default Leakage Level 2 (Default) (Default)
1 1
2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
TEMPERATURES
Programablre
Ceiling Fans:
�Thermostart:�Y
Heating [X] Jan
[X] Feb
r ,
[X] Mar
Apr
May
Jun
[)(]
[ j Jul
r�(]
[ ] Aug
[�
[) Sep
j Oct
�,{ Oct
Nov
Nov
Dec;
Dec
Venting [[[[ 1111 Jan
[[[[ 1111 Feb
[[[[�xxx]]]] Mar
Jun
[)Jul
[[[ 1 Aug
[)Sep
�^�
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 10701 S Ocean Dr Lot 644 PERMIT #:
Jensen Beach, FL, 34957-
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and.
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
2/24/2014 9:38 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6