Loading...
HomeMy WebLinkAboutInsulation - Installation Certificate403-0 t(-,,,4 INSULATION INSTALLATION CERTIFICATE LOT BLOCK: SECTION: JOB ADDRESS: lU IU I---) ( 1 ,�ckf ,Ur" "7 'LATh) 1"'1 1 V The undersigned; hereby certifies that insulation has, been installed at the above described property as follows: 1. Exterior CBS wafts have been -insulated: ...........................Check.one ( )"Spray on cellulose to a thickness of NIA inches, which thickness, according to the O Fiberglass blankets manufacturer; � Aluminum Foil Density N/A will4 i" Rk' value of L I �WRiaid Exterior Frame walls have been insulated with . ............................Check one ( Spray on cellulose to a thickness ( J2 inches; which thickness, according to the Fiberglass blankets manufacturer, o ,t j� "Ova � Corn l�� ( ) Aluminum Foil Densi. N/A will ieTd ar?`* value o. t ( ) Other Spray Foam Main Ceilings have been insulated. With .......................... Check.one (j Fiberglass blankets to a.thickness of inc s, wh�Of_� ordin a the () Fiberglass loose fill manufacturer, O Aluminum Foil Density N/A will yr e , , an "R" vOther Cellulose Ceilings Cathedral have been insulate_ d'with ......:......:.:.:.:..:.:Check one ( )_Fiberglass blankets to a thickness of inches,, which thickness, according to the (j Fiberglass loose fill manufacturer, () Aluminum Foil Density N/A will yield an "R" value of ( ) Other Ceulose 3. Interior knee walls.have been insulated with.................................Check one O Fiberglass blankets to: a thickness of inches, which .thickness, according to, the (,) Polyurethane manufacturer, () Spray on cellulose Density NIA will yield an "R" value of ()Other Spray Foam 4. Garage partition walls of conditioned living areas have. been insulated with.. ..............::: :: ::................................................ Check one WFibprglass blankets to a thiekness_o �2 inches, which thickness, according to the () Spray on cellulose manufacturer, CV 17 CLQ6fr 7 () Polyurethane Density N/A will—yiel an �►'�, ` I O Other Aluminum Foil MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating different tenants shall be insulated as follows - Frame/Metal stud walls R-11 (Min.); CBS or Concrete walls. R-3 (Min.); by Energy Code requirements. See Energy Code Rev. I/87, paragraph 903.2(b), on page 9-17, latest edition. These "minimums. levels of insulation" are ngt -included in the Energy Calculations, but shall be installed.in the field. NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulation shall be the ,P.C.F. (lb/R3) average of three (3)"DRY SAMPLES" of actaal installatr'Qri,, , ' r -k ti TI Uuz Insulation Contractor insulation Contractor's CC# Date, of: Certification i - , - I ]��_ C6C1AZ37b uilder's Name Builder's CC# No Pub 'c ,,.o.o`' °yea, KELLY L YOUNG Notary Public -State of Florida ec My Comm. Expires Jul 1. 2018 .�,. Commission # FF 138101