Loading...
HomeMy WebLinkAboutProject Informationr Project Summary Job: MJ14022OBTB 11\ener house , y Date: February 20, 2014 Entire House By: Bruce Tschosik e c h n o l o g Y Energy House Technology ..uwrc�zr�w.wr.... nnr a.a•rr 3341 Pine Hill Trail, Palm Beach Gardens, FL33418 Phone: 561-459-0242 Email: Bruce@EnergyHT.com Web: www.EnergyHT.com License: 927 For: Brian Roat c/o Kessel, Homecrete Homes 10701 S Ocean Dr, Lot 644, Jensen Beach, FL 34957 Phone:772-873-9574 Email: broat@homecretehomes.com Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 °F Inside db 70 OF Inside db 75 cF Design TD 28 OF Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 19227 Btuh Ducts 1303 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 20529 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ft2) 1184 1184 Volume ft3) 10287 10287 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 77 39 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 0 HSPF 0 Btuh @ 47°F 0 OF 957 cfm 0.047 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 20080 Btuh Ducts 967 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 19995 Btuh Latent Cooling Equipment Load Sizing Structure 5247 Btuh Ducts 719 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 5966 Btuh Equipment total load 25960 Btuh Req. total capacity at 0.70 SHR 2.4 ton Cooling Equipment Summary Make Trade Cond Coil AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 0 SEER 0 Btuh 0 Btuh 0 Btuh 957 cfm 0.045 cfm/Btuh 0.50 in H2O 0.78 Wrl F1t SO1ft" - - 2014-Feb-24 09:45:42 r g Right -Suites Universal 2012 12.1.08 RSU11733 Page 1 ...ftlHomecrete_Homes_Kessel_Hutchinson_Island.rup Calc = MJ8 Front Door faces: W Job M MJ14O22OBTB Energy House Technology Scale: 1 : 60 Performed by Bruce Tschosik for: Page 1 Bdan Roat c/o Kessel 3341 Pine Hill Trail Right -Suite® Universal 2012 10701 S Ocean Dr, Lot 644 Palm Beach Gardens, FL 33418 12.1.08 RSU11733 Jensen Beach, FL 34957 Phone: 772-873-9574 Ph 2014•Fer24 09:45:51 ...mesKesselHutchinson_Island.rup www•EnergyHTcom Bruse@EnergyHTcom broat@homecretehomes.com Level 2 Job M MJ14022OBTB Energy House Technology Scale:1 :60 Performed by Bruce Tschosik for: Page Brian Roat c/o Kessel 3341 Pine Hill Trail Right -Suite® Universal2012 10701 S Ocean Dr, Lot 644 Palm Beach Gardens, FL 33418 12.1.08 RSU11733 Jensen Beach, FL 34957 Phone: 561�159-0242 2014-Fetr2409:45:51 mes Kesset—Hutchinson lsland.np Phone: 772-873-9574 www.EnergyHT.com Bruce@EnergyHT.com broat@hom ec retehom es.com Duct System Summary Job: MJ14022OBTS ener house Date: February 20, 2014 e c h n o l o g y Entire House By: BruceTschosik A,-,t-.-9--.• r.-o ,, Energy House Technology 3341 Pine Hill Trail, Palm Beach Gardens, FL33418 Phone: 561-459-0242 Email: Bruce@EnergyHT.com Web: www.EnergyHT.com License: 927 For: Brian Roat c/o Kessel, Homecrete Homes 10701 S Ocean Dr, Lot 644, Jensen Beach, FL 34957 Phone: 772-873-9574 Email: broat@homecretehomes.com External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating a5o in H2O 0.29 in H2O 0.21 in H2O 0.11 / 0.11 in H2O 0.086 in/100ft 957 cfm 245 ft Cooling 0.50 in H2O 0.29 in H2O 0.21 in H2O 0.11 / 0.11 in H2O 0.086 in/100ft 957 cfm Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 2 h 1305 61 33 0.151 4.0 Ox 0 VIFx 9.2 130.0 st2 Great Room C 3625 169 169 0.098 8.0 Ox 0 VIFx 34.3 180.0 stl Great Room -A C 3625 169 169 0,092 8.0 Ox 0 VIFX 43.4 185.0 stl Guest BR h 2465 115 110 0.150 6.0 Ox 0 VIFx 10.0 130.0 st2 latchen C 2068 81 94 0.104 6.0 Ox 0 VIFX 27.0 175.0 stl Master BR C 3364 123 153 0.086 8.0 Ox 0 VIFx 25.5 220.0 st3 Master BRA C 3364 123 153 0.086 8.0 Ox 0 VIFx 23.1 220.0 st3 Master Bath h 776 36 26 0.146 4.0 Ox 0 VIFX 14.3 130.0 st2 Powder h 1422 66 34 0.106 4.0 Ox 0 VIFX 23.2 175.0 stl Storage C 362 13 16 0.133 4.0 Ox 0 VIFX 22.9 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FR (fpm) (in) (in) Material Trunk stl Peak AVF 485 465 0.092 644 11.3 7 x 17 RectFbg st2 Peak AVF 471 491 0.086 590 11.5 12 x 10 RectFbg st3 Peak AVF 246 306 0.086 561 10.0 0 x 0 VinlFlx st2 Bold/italic values have been manually overridden rC wri htsoft° 2014-Feb-24 09:45:42 9 Right -Suite® Universal 2012 12.1.08 RSU11733 page 1 ...ft\Homecrete_Homes_Kessel_Hutchinson_Island.rup Cale = MJ8 Front Door faces: W Return Branch Detail Table Name Grill Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rbi Ox 0 957 957 0 0 0 0 Ox 0 VIFx ~z' I- wrightsoft' Right -Suite® Universal 2012 12.1.08 RSU11733 X& ..ft\Homecrete_Homes_Kessel_Hutchinson_Island.rup Cato - MJ8 Front Door faces: W 2014-Feb-24 09:45:42 Page 2