HomeMy WebLinkAboutAPPROVED Energy Codes 2110-0356 Ravinia 4 GL FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Ravinia 4-LHG Builder Name:
Street: Permit Office: St. Lucie County
City,State,Zip: Port St. Lucie, FL,34953 Permit Number:
Owner: Ravinia 4-LHG Jurisdiction: 661000
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Type$1408.0 sqft.) Insulation Area
2. Single family or multiple family Detached a. Concrete Block-Int Insul, Exterior R=4.1 1184.00 ft2
b.Frame-Wood,Adjacent R=13.0 224.00 ft2
3. Number of units, if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 4 d. N/A R= ft2
5. Is this a worst case? Yes 11.Ceiling Types (1620.0 sqft.) Insulation Area 2
a. Under Attic(Vented) R=30.0 1620.00 ft
6. Conditioned floor area above grade(ft2) 1620 b. N/A R= ft2
Conditioned floor area below grade(ft2) 0 c. N/A R= ft2
7. Windows(126.0 sqft.) Description Area 12. Ducts R ft2
a. U-Factor: Sgl,U=0.39 126.00 ft2 a.Sup:Attic, Ret:Attic,AH:Attic 6 75
SHGC: SHGC=0.20
b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 28.6 SEER:14.50
c. U-Factor: N/A ft2
SHGC: 14. Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 1.417 ft. a. Electric Strip Heat 27.0 COP:1.00
Area Weighted Average SHGC: 0.200
8. Skylights Area
c. U-Factor:(AVG) N/A ft2 15. Hot water systems
SHGC(AVG): N/A a.Electric Cap:50 gallons
9. Floor Types (1620.0 sqft.) Insulation Area EF: 0.950
a.Slab-On-Grade Edge Insulation R=0.0 1620.00 ft2 b. Conservation features
b. N/A R= ft2 None
c.N/A R= ft2 16.Credits CIF
Glass/Floor Area: 0.078 Total Proposed Modified Loads: 50.39 PASS
Total Baseline Loads: 51.07
I hereby certify that the plans and specifications covered by Review of the plans and 'VIAE S 4r
this calculation are in compliance with the Florida Energy specifications covered by this w� 6: S" 0
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE: 11-4-2n21 this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes. � ��,
with the Florida Energy Code. 7,C W'E
OWNER/AGENT: BUILDING OFFICIAL:
DATE: 1 i-!I -7- , DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).
11/4/2021 1:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Ravinia 4-LHG Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1620 Lot#
Owner Name: Ravinia 4-LHG Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Rotate Angle: 180 Street:
Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie
Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Port St. Lucie,
Family Type: Detached FL, 34953
New/Existing: New(From Plans)
Comment:
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1620 12960
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 M Bedroom 196 1568 No 2 1 1 Yes Yes Yes
2 M WIC 48 384 No 0 1 No Yes Yes
3 M Bath 84 672 No 1 1 Yes Yes Yes
4 Bedroom 4 143 1144 No 1 1 1 Yes Yes Yes
5 Bath 2 78 624 No 0 1 Yes Yes Yes
6 Bedroom 2 143 1144 No 1 1 1 Yes Yes Yes
7 Foyer 60 480 No 0 1 Yes Yes Yes
8 Great Room 232 1856 No 2 1 Yes Yes Yes
9 Dining 128 1024 No 2 1 Yes Yes Yes
10 Kitchen 202 1616 Yes 2 1 Yes Yes Yes
11 Laundry 80 640 No 0 1 Yes Yes Yes
12 Bedroom 3 136 1088 No 1 1 1 Yes Yes Yes
13 Hall 90 720 No 0 1 No Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio M Bedroom 32 ft 196 ftz ---- 1 0 0
2 Slab-On-Grade Edge Insulatio M WIC 1 ft 48 ftz ---- 1 0 0
3 Slab-On-Grade Edge Insulatio M Bath 6 ft 84 ftz ---- 1 0 0
4 Slab-On-Grade Edge Insulatio Bedroom 4 11 ft 143 ftz ---- 1 0 0
11/4/2021 1:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
5 Slab-On-Grade Edge Insulatio Bath 2 6 ft 78 ft2 ---- 1 0 0
6 Slab-On-Grade Edge Insulatio Bedroom 2 19 ft 143 ft2 ---- 1 0 0
7 Slab-On-Grade Edge Insulatio Foyer 6 ft 60 ft2 ---- 1 0 0
8 Slab-On-Grade Edge Insulatio Great Room 30 ft 232 ft2 ---- 1 0 0
9 Slab-On-Grade Edge Insulatio Dining 8 ft 128 ft2 ---- 1 0 0
10SIab-On-Grade Edge Insulatio Kitchen 12 ft 202 ft2 ---- 1 0 0
11SIab-On-Grade Edge Insulatio Laundry 8 ft 80 ft2 ---- 1 0 0
12SIab-On-Grade Edge Insulatio Bedroom 3 loft 136 ft2 ---- 1 0 0
13SIab-On-Grade Edge Insulatio Hall 1 ft 90 ft2 ---- 1 0 0
ROOF
/ Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 1811 ft2 406 ft2 Medium N 0.6 No 0.9 No 0 26.57
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1620 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) M Bedroom 30 Batt 196 ft2 0.1 Wood
2 Under Attic(Vented) M WIC 30 Batt 48 ft2 0.1 Wood
3 Under Attic(Vented) M Bath 30 Batt 84 ft2 0.1 Wood
4 Under Attic(Vented) Bedroom 4 30 Batt 143 ft2 0.1 Wood
5 Under Attic(Vented) Bath 2 30 Batt 78 ft2 0.1 Wood
6 Under Attic(Vented) Bedroom 2 30 Batt 143 ft2 0.1 Wood
7 Under Attic(Vented) Foyer 30 Batt 60 ft2 0.1 Wood
8 Under Attic(Vented) Great Room 30 Batt 232 ft2 0.1 Wood
9 Under Attic(Vented) Dining 30 Batt 128 ft2 0.1 Wood
10 Under Attic(Vented) Kitchen 30 Batt 202 ft2 0.1 Wood
11 Under Attic(Vented) Laundry 30 Batt 80 ft2 0.1 Wood
12 Under Attic(Vented) Bedroom 3 30 Batt 136 ft2 0.1 Wood
13 Under Attic(Vented) Hall 30 Batt 90 ft2 0.1 Wood
11/4/2021 1:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N=>S Exterior Concrete Block-Int InsuM Bedroom 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0
2 W=>E Exterior Concrete Block-Int InsuM Bedroom 4.1 18 0 8 0 144.0 ft2 0 0 0.3 0
3 W=>E Exterior Concrete Block-Int Insul M Bath 4.1 6 0 8 0 48.0 ft2 0 0 0.3 0
4 W=>E Exterior Concrete Block-Int InsuBedroom 4 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0
5 W=>E Exterior Concrete Block-Int Insul Bath 2 4.1 6 0 8 0 48.0 ft2 0 0 0.3 0
6 S=>N Exterior Concrete Block-Int InsuBedroom 2 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0
7 W=>E Exterior Concrete Block-Int InsuBedroom 2 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0
8 W=>E Exterior Concrete Block-Int Insul Foyer 4.1 6 0 8 0 48.0 ft2 0 0 0.3 0
9 N=>S Exterior Concrete Block-Int InsuGreat Room 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0
10 E=>W Exterior Concrete Block-Int Insu(Great Room 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0
11 E=>W Exterior Concrete Block-Int Insul Dining 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0
12 E=>W Exterior Concrete Block-Int Insul Kitchen 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0
13 E=>W Exterior Concrete Block-Int Insul Laundry 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0
14 E=>W Exterior Concrete Block-Int InsuBedroom 3 4.1 10 0 8 0 80.0 ft2 0 0 0.3 0
15 W=>E Garage Frame-Wood Foyer 13 10 8 80.0 ft2 0.23 0.3 0
16 S=>N Garage Frame-Wood Foyer 13 6 8 48.0 ft2 0.23 0.3 0
17 W=>E Garage Frame-Wood Bedroom 3 13 12 8 96.0 ft2 0.23 0.3 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 W=>E Insulated Foyer None .39 3 6 10 20.5 ft2
2 W=>E Insulated Foyer None .39 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation(=>)changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>S 1 Vinyl Low-E Single Yes 0.39 0.2 Y 20.0 ft2 1 ft 5 in 1 ft 4 in None None
2 W=>E 4 Vinyl Low-E Single Yes 0.39 0.2 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None
3 S=>N 6 Vinyl Low-E Single Yes 0.39 0.2 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None
4 N=>S 9 Vinyl Low-E Single Yes 0.39 0.2 Y 41.0 ft2 1 ft 5 in 1 ft 4 in None None
5 E=>W 11 Vinyl Low-E Single Yes 0.39 0.2 Y 20.0 ft2 1 ft 5 in 1 ft 4 in None None
6 E=>W 14 Vinyl Low-E Single Yes 0.39 0.2 Y 15.0 ft2 1 ft 5 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 528 ft2 528 ft2 28 ft 8 ft 13
11/4/2021 1:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000254 1080 59.25 111.24 .0902 5
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER: 14.528.6 kBtu/hr 858 cfm 0.7 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Laundry 0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 75 ftz Attic 20 ftz Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
CoolingJan Feb Mar A r May X Jun X JUI X Auge Oct Nov Dec
Heatin Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec
11/4/2021 1:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M Bedroom
Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC
Default(8 Ibs/sq.ft. ft2 ft 0.3 M Bath
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer
Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room
Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining
Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen
Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall
11/4/2021 1:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 6
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
, Port St. Lucie, FL, 34953
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1184.00 ftz
b. Frame-Wood,Adjacent R=13.0 224.00 ft
3. Number of units, if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 4 d. N/A R= ft2
5. Is this a worst case? Yes 11.Ceiling Type and insulation level Insulation Area
a. Under Attic(Vented) R=30.0 1620.00 ft2
6. Conditioned floor area(ft2) 1620 b. N/A R= ft2
7. Windows" Description Area
c. N/A R= ft2
a. U-Factor: Sgl,U=0.39 126.00 ft2 12. Ducts, location&insulation level R ft2
SHGC: SHGC=0.20 a.Sup:Attic, Ret:Attic,AH:Attic 6 75
b. U-Factor: N/A ft2
SHGC: 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 28.6 SEER:14.50
SHGC:
d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency
SHGC: a. Electric Strip Heat 27.0 COP:1.00
Area Weighted Average Overhang Depth: 1.417 ft.
Area Weighted Average SHGC: 0.200
8. Skylights Description Area
15. Hot water systems
a. Electric Cap: 50 gallons
a. U-Factor(AVG): N/A ft2EF:0.95
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 1620.00 ft2 Credits(Performance method) CIF
b. N/A R= ft2
c. N/A R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building 1114E ST
Construction through the above energy saving features which will be installed (or exceeded) �0 m ram'
in this home before final inspection. Otherwise, a new EPL Display Card will be completed w� .., ' _ '` +,
based on installed Code compliant features. =;,, 0
Builder Signature: ¢ Date:
Address of New Home: City/FL Zip: . w1 `��
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/4/2021 1:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Ravinia 4-LHG Builder Name:
Street: Permit Office: St. Lucie County
City,State,Zip: Port St. Lucie, FL,34953 Permit Number: Y
U
Owner: Ravinia 4-LHG Jurisdiction: 661000 w
Design Location: FL, Fort Pierce U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and an gaps in the air barrier shall be sealed.
Y 9 p shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts, penetrations Duct shafts, utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind p'p*na and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or cellinas,
a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
11/4/2021 1:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1