Certification for Design Load Compliance
7t" Edition
Project Name: RAVINIA 4 RH MASTER PERMIT
Project Address: TBD
Permit#: Occupancy Type: R-3 Construction Type:5B
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record.
• If submitting hard copy,submit(2)copies with all pertinent information.St Lucie Fire District requires a digitally
signed electronic version.
• If submitting electronically,form should be uploaded into Bluebeam.Separate submission to Fire is still required
• All digital files must be in an unlocked Portable Document Format(PDF)version
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the plan reviewer. Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2020 Code 7th Edition using ASCE 7-16
2. Structure Designed as(check one): X Enclosed Partially Enclosed Open
3. Risk Category: 1 II X III IV Exposure Category: B X C D
4. Design Wind Velocity 170 mph ASD LRFD End Zone Width:3 ft
5. Mean Roof Height 15 ft Roof Pitch:4 :12 Parapet: N/A ft
6. Components&Cladding Design Pressures Used:
Zone 4: Zone 5: Garage: +31.86/-38.74
6a. Roofs
Maximum+/-pressures:+ psf - psf Or define individual zones on the plans
7. Design Loads: Floor: N/A PSF Roof-Dead:25 PSF Roof-Live:30 Balcony+/-N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs:N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure?X Yes Not Applicable Please Explain:
9. Is a Continuous Load Path Provided?X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure:2500 PSF Soil Test Reports Submitted? Yes No Assumed
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the current Florida Building Code as adopted.
Digitally signed by Lillian Gonz
Date:2021.08.2412:59:20-04'alez Lillian Gonzalez 79442 & 32045
Signature, Date,and Seal _Print Name Cert#&Co.CertofAuthorization
Goarch Engineering, Inc 1824 Richard Ln Palm Springs, FL 33406
Revised 3/25/2021 Company Name&Address