Loading...
HomeMy WebLinkAboutAPPROVED wind load certification 2110-0357 Ravinia 4 GR Planning& Development Services Department } Building & Code Regulations Division �, # 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1577 Certification for Design Load Compliance 7t" Edition Project Name: RAVINIA 4 RH MASTER PERMIT Project Address: TBD Permit#: Occupancy Type: R-3 Construction Type:5B INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. • If submitting hard copy,submit(2)copies with all pertinent information.St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically,form should be uploaded into Bluebeam.Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format(PDF)version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2020 Code 7th Edition using ASCE 7-16 2. Structure Designed as(check one): X Enclosed Partially Enclosed Open 3. Risk Category: 1 II X III IV Exposure Category: B X C D 4. Design Wind Velocity 170 mph ASD LRFD End Zone Width:3 ft 5. Mean Roof Height 15 ft Roof Pitch:4 :12 Parapet: N/A ft 6. Components&Cladding Design Pressures Used: Zone 4: Zone 5: Garage: +31.86/-38.74 6a. Roofs Maximum+/-pressures:+ psf - psf Or define individual zones on the plans 7. Design Loads: Floor: N/A PSF Roof-Dead:25 PSF Roof-Live:30 Balcony+/-N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs:N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure?X Yes Not Applicable Please Explain: 9. Is a Continuous Load Path Provided?X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure:2500 PSF Soil Test Reports Submitted? Yes No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the current Florida Building Code as adopted. Digitally signed by Lillian Gonz Date:2021.08.2412:59:20-04'alez Lillian Gonzalez 79442 & 32045 Signature, Date,and Seal _Print Name Cert#&Co.CertofAuthorization Goarch Engineering, Inc 1824 Richard Ln Palm Springs, FL 33406 Revised 3/25/2021 Company Name&Address