APPROVED Manual J 2110-0358 Ravinia 3 GL
rightsoft Project Summary Jo Date: Entire House By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com Project • • For: Ravinia 3- Left Hand Garage Port St. Lucie, FL Notes: Desiqn Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15178 Btuh Structure 16123 Btuh Ducts 4193 Btuh Ducts 5107 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19370 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 20168 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4045 Btuh Ducts 1590 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1440 1440 Equipment latent load 5634 Btuh Volume (ft3) 11520 11520 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 25802 Btuh Equiv.AVF (cfm) 86 44 Req.total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR403OLl AHRI ref Coil TEM4AOB3OS31++TDR AHRI ref 7482002 Efficiency 100 EFF Efficiency 12.0 EER, 14.5 SEER Heating input 5.7 kW Sensible cooling 20020 Btuh Heating output 19575 Btuh Latent cooling 8580 Btuh Temperature rise 19 °F Total cooling 28600 Btuh Actual air flow 953 cfm Actual air flow 953 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. rlghtsnft- 2021-Oct-1217:38:09 Right-Suite(g)Universal 2021 21.0.08 RSU08101 Page 1 ...rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE +}+ wrightsoft- Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Entire House M Bedroom 2 Exposed wall 141.0 ft 32.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 1.0 x 195.0 ft 5 Room area 1440.0 ft' 195.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'°F (Btu hlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VLG13A-4ocs 0.143 n 4.00 2.19 392 352 1408 769 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 20 0 504 396 0 0 0 0 D 11 DO 0.390 n 10.92 10.34 20 20 223 211 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 80 65 260 142 0 0 0 0 11 1A-rlov 0.900 a 25.20 42.33 15 0 378 635 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 416 386 1546 845 144 144 577 315 1A-rlov 0.900 s 25.20 19.79 30 30 756 594 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 240 179 718 392 112 92 368 201 1A-rlov 0.900 w 25.20 42.33 20 0 504 847 20 0 504 847 1A-rlovd 0.900 w 25.20 42.33 41 0 1028 1727 0 0 0 0 C 166-30ad 0.032 0.90 1.60 1440 1440 1290 2304 195 195 175 312 F 22A-tol 0.989 27.69 0.00 1440 141 3905 0 195 32 886 0 61 c)AED excursion 1 6041 1 1 271 Envelope loss/gain 12519 9465 2510 1946 12 a) Infiltration 2659 728 603 165 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 11 2530 2 460 Appliances/other 3400 0 Subtotal(lines 6 to 13) 15178 16123 3113 2571 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 15178 16123 3113 2571 15 Duct loads 28% 32% 4193 5107 28% 32% 860 814 Total room load 19370 21229 1 1 3973 3385 Air required(cfm) 1 1 953 953 196 152 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■�gntsort 2021-Oct-12 17:38:09 Right-Suite(g)Universal 2021 21.0.08 RSU08101 Page 1 rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE +}+ wrightsoft- Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name M WIC M Bath 2 Exposed wall 0 ft 6.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 8.0 x 6.0 ft 14.0 x 6.0 ft 5 Room area 48.0 ft' 84.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'°F (Btu hlft') or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 D 11 DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 48 48 192 105 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 1A-rlovd 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 C 166-30ad 0.032 0.90 1.60 48 48 43 77 84 84 75 134 F 22A-tol 0.989 27.69 0.00 48 0 0 0 84 6 166 0 6 c)AED excursion 1 -21 I I 14 Envelope loss/gain i 43 75 i 1 434 226 12 a) Infiltration 0 0 113 31 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 43 75 547 487 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 43 75 547 487 15 Duct loads 28% 32% 12 24 28% 32% 151 154 Total room load 55 98 1 1 698 641 Air required(cfm) 1 3 4 34 29 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■�gntsort 2021-Oct-12 17:38:09 RightSuiteO Universal 202121.0.08RSU08101 Page rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE +}+ wrightsoft- Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Bedroom 3 Bath 2 2 Exposed wall 11.0 ft 6.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 13.0 x 11.0 ft 9.0 x 6.0 ft 5 Room area 143.0 ft' 54.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'°F (Btu hlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 D 11 DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 88 73 292 160 48 48 192 105 1A-rlov 0.900 s 25.20 19.79 15 15 378 297 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 1A-rlovd 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 C 166-30ad 0.032 0.90 1.60 143 143 128 229 54 54 48 86 F 22A-tol 0.989 27.69 0.00 143 11 305 0 54 6 166 0 6 c)AED excursion -27 i 6 Envelope loss/gain 1103 658 407 185 12 a) Infiltration 207 57 113 31 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1310 945 520 216 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 8 14 9 16 14 Subtotal 1318 959 529 232 15 Duct loads 28% 32% 364 304 28% 32% 146 74 Total room load 1683 1263 1 1 675 306 Air required(cfm) 1 83 57 33 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■�gntsort 2021-Oct-12 17:38:09 RightSuiteO Universal 202121.0.08RSU08101 Page rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE +}+ wrightsoft- Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Bedroom 2 Great Room 2 Exposed wall 11.0 ft 30.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 13.0 x 11.0 ft 1.0 x 232.0 ft 5 Room area 143.0 ft' 232.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'°F (Btu hlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VLG13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 112 112 448 245 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 D 11 DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 Vy 13A-flocs 0.143 s 4.00 2.19 88 73 292 160 0 0 0 0 L-G 1A-rlov 0.900 s 25.20 19.79 15 15 378 297 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 128 87 349 191 1A-rlov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 1A-rlovd 0.900 w 25.20 42.33 0 0 0 0 41 0 1028 1727 C 166-30ad 0.032 0.90 1.60 143 143 128 229 232 232 208 371 F 22A-tol 0.989 27.69 0.00 143 11 305 0 232 30 831 0 6 c)AED excursion 1 -271 1 1 1 575 Envelope loss/gain 1 1103 658 1 2864 3109 12 a) Infiltration 207 57 566 155 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 0 900 Subtotal(lines 6 to 13) 1310 945 3430 4394 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 11 0 0 14 Subtotal 1317 956 3430 4394 15 Duct loads 28% 32% 364 303 28% 32% 948 1392 Total room load 1680 1259 1 1 4378 5785 Air required(cfm) 1 83 57 215 260 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■�gntsort 2021-Oct-12 17:38:09 RightSuiteO Universal 202121.0.08RSU08101 Page rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE +}+ wrightsoft- Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Dining Kitchen 2 Exposed wall 8.0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 16.0 x 8.0 ft 1.0 x 202.0 ft 5 Room area 128.0 ft' 202.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'°F (Btu hlft') or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VLG13A-4ocs 0.143 n 4.00 2.19 64 44 176 96 96 96 384 210 1A-rlov 0.900 n 25.20 19.79 20 0 504 396 0 0 0 0 D 11 DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 1A-rlovd 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 C 166-30ad 0.032 0.90 1.60 128 128 115 205 202 202 181 323 F 22A-tol 0.989 27.69 0.00 128 8 222 0 202 12 332 0 I I I I I I I I I 61 c)AED excursion I I I I -331 I I 185 Envelope loss/gain 1016 664 1 1 898 449 12 a) Infiltration 151 41 226 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 0 2000 Subtotal(lines 6 to 13) 1167 1165 1124 2971 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 9 15 14 Subtotal 1167 1165 1133 2986 15 Duct loads 28% 32% 322 369 28% 32% 313 946 Total room load 1490 1534 1 1 1446 3932 Air required(cfm) 1 73 69 71 177 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■�gntsort 2021-Oct-12 17:38:09 RightSuiteO Universal 202121.0.08RSU08101 Page rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE +}+ wrightsoft- Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Laundry Hall 1 2 Exposed wall 17.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 12.0 x 7.0 ft 5.0 x 7.0 ft 5 Room area 84.0 ft' 35.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'°F (Btu hlft') or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VLG13A-4ocs 0.143 n 4.00 2.19 56 56 224 123 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 D 11 DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 80 65 260 142 0 0 0 0 11 1A-rlov 0.900 a 25.20 42.33 15 0 378 635 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 1A-rlovd 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 C 166-30ad 0.032 0.90 1.60 84 84 75 134 35 35 31 56 F 22A-tol 0.989 27.69 0.00 84 17 471 0 35 0 0 0 I I I I I I I I I 61 c)AED excursion I I I -33I I I 1 -2 Envelope loss/gain i 1409 1001 i 1 31 1 54 12 a) Infiltration 321 88 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 1729 1819 31 54 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 12 21 -31 -54 14 Subtotal 1741 1840 0 0 15 Duct loads 28% 32% 481 583 28% 32% 0 0 Total room load 2222 2423 1 1 0 0 Air required(cfm) 1 109 109 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■�gntsort 2021-Oct-12 17:38:09 RightSuiteO Universal 202121.0.08RSU08101 Page rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE +}+ wrightsoft- Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Foyer Hall 2 2 Exposed wall 8.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 68.0 ft 4.0 x 6.0 ft 5 Room area 68.0 ft' 24.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'°F (Btu hlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VLG13A-4ocs 0.143 n 4.00 2.19 64 44 175 95 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 D 11 DO 0.390 n 10.92 10.34 20 20 223 211 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 1A-rlovd 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0 C 166-30ad 0.032 0.90 1.60 68 68 61 109 24 24 22 38 F 22A-tol 0.989 27.69 0.00 68 8 222 0 24 0 0 0 I I I I I I I I I 6 c)AED excursion I I I I -13 I 1 1 Envelope loss/gain 680 402 i 1 22 37 12 a) Infiltration 151 41 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 831 444 22 37 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 9 15 -22 -37 14 Subtotal 839 459 0 0 15 Duct loads 28% 32% 232 145 28% 32% 0 0 Total room load 1071 604 1 1 0 0 Air required(cfm) 1 1 53 27 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■�gntsort 2021-Oct-12 17:38:09 RightSuiteO Universal 202121.0.08RSU08101 Page rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE rightsoft Duct System Summary Date: Entire House By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com Project Information For: Ravinia 3- Left Hand Garage Port St. Lucie, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.296 in/100ft 0.296 in/100ft Actual air flow 953 cfm 953 cfm Total effective length (TEL) 169 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 2 h 675 33 14 0.390 4.0 Ox 0 VIFx 13.3 115.0 st2 Bedroom 2 h 1680 83 57 0.378 7.0 Ox 0 VIFx 17.2 115.0 st2 Bedroom 3 h 1683 83 57 0.376 7.0 Ox 0 VIFx 17.8 115.0 st3 Dining h 1490 73 69 0.380 7.0 Ox 0 VIFx 16.5 115.0 SO Foyer h 1071 53 27 0.393 5.0 Ox 0 VIFx 12.2 115.0 st2 Great Room c 2893 108 130 0.301 7.0 Ox 0 VIFx 31.2 135.0 st4 Great Room-A c 2893 108 130 0.301 7.0 Ox 0 VIFx 31.2 135.0 st4 Kitchen c 3932 71 177 0.380 8.0 Ox 0 VIFx 16.5 115.0 SO Laundry h 2222 109 109 0.497 6.0 Ox 0 VIFx 5.7 95.0 M Bath h 698 34 29 0.379 4.0 Ox 0 VIFx 17.1 115.0 st3 M Bedroom h 1987 98 76 0.304 6.0 Ox 0 VIFx 29.3 135.0 st5 M Bedroom-A h 1987 98 76 0.296 6.0 Ox 0 VIFx 33.7 135.0 st5 M wlc c 98 3 4 0.305 4.0 Ox 0 VIFx 28.8 135.0 st5 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 169 97 0.378 483 8.0 0 x 0 VinlFlx st3 Peak AVF 315 242 0.296 578 10.0 0 x 0 VinlFlx SO Peak AVF 360 505 0.301 473 14.0 0 x 0 VinlFlx st5 Peak AVF 198 156 0.296 568 8.0 0 x 0 VinlFlx st3 st4 Peak AVF 215 260 0.301 588 9.0 0 x 0 VinlFlx st1 WV r ightsof#' 2021-Oct-12 17:38:09 Right-Suite(g)Universal 2021 21.0.08 RSU08101 Page 1 ...rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 953 953 0 0 0 0 Ox 0 VIFx ynrr� li# 2021-Oct-1217:38:09 RightSuiteOUniversal 2021 21.0.08 RSU08101 Page ...rightsoft HVAC\Ravina 3-Letft Hand Garage.rup Calc=MJ8 Front Door faces:NE