Loading...
HomeMy WebLinkAboutTrussM1t� MiTek' Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. File C®pf -HE: M11323 - 62' Grand Carlton III with porch MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: WYNNNE DEVELOP EMENT CORP Project Name: M11323 Modeil p1a1�1236104115 Lot/Block: Subdivision: 1 Address: N/A City: PORT ST LUCIE State; FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2014/TP12007 Design Program: MiTek 20/20 7.6 Wind Code: ASCE 7-10 [All HeighIl Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. I Seal# Truss Name Date 1 IT9680954 JA 10/17/16 12 I T9680955 I A5 1 10/17/16 1 13 I T9680956 I A6 f 10/17/16 14 I T9680957 J A7 j 10/17/16 1 15 I T9680958 J A8 1 10/17/16 1 16 I T9680959 J A9 1 10/17/16 1 17 I T9680960 I G RA 1 10/17/16 1 18 IT9680961 I GRB 1 10/17/16 1 19 I T9680962 J J2 1 10/17/16 1 110. I T9680963 J J4 1 10/17/16 1 Ill I T9680964 J J6 1 10/17/16 1 112 I T9680965 l J8 1 10/17/16 1 113 I T9680966 J KJ8 1 10/17/16 1 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2017. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon•parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. �%���`QV I N r VF 4% �s G�E N 6 182 � r : 3 •. STATE OF : 4/Z 1 Joaquin Velez PE No.68182 MiTek USA, Inc. FL Gert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: October 17,2016---_ Velez, Joaquin 1 of 1 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9680954 M11323 A COMMON 9 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Apr 19 2016 MiTek Industries, Inc. Mon Oct 17 10:40:01 2016 Page 1 I D:a3B4PavKnnZweXyJckSFBgyuFUN-iMeaXsQ91 rHM W rvch)pgcTUSEIMd6iD2tQGCyMySYQy r1-0-Q 6-7-13 12-4-13 17-0-0 21-7-0 27-4-3 i 34-0-0 3.5 1-0-0 6-7-13 5-9-0 4-7-3 4-7-3 5-9-0 6-7-13 1-0 0 r)1 6 4.00 12 4x4 = 25 Scale = 1:59.2 17 15 `- " 14 '- 12 4x5 — 2x3 II 4x6 = 3x8 = 3x8 = 4x6 2x3 II 4x5 = 1 t2 0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.33 Vert(LL) 0.29 15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.55 Vert(TL) -0.72 14-15 >567 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.54 Horz(TL) 0.14 10 n/a n/a BCDL 10.0 Code FBC2014lTP12007 (Matrix-M) Weight: 163 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-11-7 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-9-1 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1362/0-8-0, 10=1362/0-8-0 Max Harz 2=179(LC 7) Max Uplift2=-832(LC 8), 10— 832(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3= 3188/1833, 3-4=-2663/1558, 4-5— 2616/1565, 5-24=-2668/1672, 6-24=-2608/1669, 6-25=-2608/1669, 7-25=-2668/1672, 7-8— 2616/1565, 8-9=-2663/1558, 9-10=-3188/1833 BOT CHORD 2-17=-1629/2972, 16-17= 1629/2972, 15-16= 1629/2972, 15-26=-934/1925, 26-27= 934/1925, 14-27_ 934/1925, 13-14=-1629/2972, 12-13=-1629/2972, 10-12= 1629/2972 WEBS 6-14= 533/948, 7-14=-328/317, 9-14=-550/387, 6-15= 533/948, 5-15=-328/317, 3-15= 550/387 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VUlt=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL=10.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 832 lb uplift at joint 2 and 832 lb uplift at joint 10. ' 6) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 29 lb up at 15-0-0, and 50 lb down and 29 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-6= 54, 6-11= 54, 18-21=-20 Concentrated Loads (lb) Vert: 24=-50(F) 25=-50(F) 0 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MrrEKREFERANCE PAGE MII-7473 rev. 10/03,2015 BEFORE USE Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not � a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall bullding design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' prevent Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage. delivery. erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSE-89 and SCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute. 218 N. Lee Street. Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9680955 M11323 AS SPECIAL 9 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Apr 19 2016 M11 eK Inaustries, Inc. Mon Uci 1 t 10:40:u8 Z01 b rage 1 ID:2GIScwwyY5hnGhXVARzUkuyuFUM-eilLyYSPZSX4mg2—pLr8huZh1Zy4adbKKkll1 FySYQw 1-0-Q 7-8-5 10-6-4 17.0-0 go 4-8 26-4-0 34-0-0 35-0-p 1-0-0 7-8-5 2-9-15 6-5-12 3-4.8 5-11-8 7-8-0 1-0-0 4.00 12 5x8 11 Scale = 1:61.2 13 12 5x12 = 2x3 II 3x6 = Wo = 2.00 12 LOADING (psf) SPACING- 2-0-0 CSL TCLL 20.0 Plate Grip DOL 1.25 TC 0.82 TCDL 7.0 Lumber DOL 1.25 BC 0.87 BCLL 0.0 Rep Stress Incr YES WB 0.49 BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except` 6-14: 2x4 SP M 30 REACTIONS. (lb/size) 2=1297/0-8-0, 10=1327/0-8-0 Max Horz2=179(LC 7) Max Uplift2=-795(LC 8), 10=-812(LC 8) DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) 0.74 14 >553 360 MT20 244/190 Vert(TL)-1.4813-14 >275 240 MT18HS 244/190 Horz(TL) 0.43 10 n/a n/a Weight: 154lb FT=0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-3-11 oc bracing. WEBS 1 Row at midpt 6-14 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3= 5402/3080, 3-4=-5047/2830, 4-5=-5005/2833, 5-6=-5093/2947, 6-7= 2352/1498, 7-8=-2330/1420, 8-9= 2383/1406, 9-10— 2979/1705 BOT CHORD 2-14= 2837/5142, 13-14=-990/2054, 12-13— 1496/2765, 10-12= 1496/2765 WEBS 3-14=-342/30915-14=-297/306, 6-14=-1796/3265, 6-13=-246/514, 7-13=-259/242, 9-13=-634/426 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tail by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 795 lb uplift at joint 2 and 812 lb uplift at joint 10. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 0 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MrTEK REFERANCE PAGE MI1-7473 rev. 1010312015 BEFORE USE Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not �� a truss system. Before use, the building designer must vetlfy the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe k' Is always required for stability and to prevent collapse with possible personal injury and property damage. for general guidance regarding the fabrlcatlom storage, delivery. erection and bracing of trusses and tn1SS systems. seeANSI/TPI1 Quality Criteria, OSa-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9680956 M11323 A6 SPECIAL 1 i Job Reference (option 1 Chambers Truss, Fort Pierce, FL r.ovv s Apr ru 20 i o Mn uk mu. - r i v u iv aga- , ID:2GIScwwyY5hnGhXVARzUkuyuFUM-6xJj9uT1 KmfxNJdBM3MNE56scyHtJ?2UZOVsZhySYQv 1-0- 8-11-11 16-0-0 18-0-0 20-4-8 25-11-15 34-0.0 5-0 1-0- 8-11-11 7-0-5 2-0-0 2-4-8 5.7-7 8-0-1 -0-0 Scale: 3/16°=1' 4.00 F12 6x8 = 5x6 = 5x6 = 2x3 11 3x6 = 3x10 = 2.00 F12 Plate Offsets (X,Y)-- (2.0-2-2 0-0-7j f3:0-3-0 Edgej (5:0-4-0 0-2-31 17:0-2-7 Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (Ioc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) 0.68 14 >601 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(fL) -1.13 14-17 >362 240 MT18HS 2441190 BCLL 0.0 ' Rep Stress Incr YES WB 0.79 Horz(TL) 0.41 9 n/a n/a BCDL 10.0 Code FBC2014/fP12007 (Matrix-M) Weight: 156lb FT=0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 'Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. 3-5: 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 4-4-0 oc bracing. BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except' 5-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1298/0-8-0, 9=1326/0-8-0 Max Harz 2=169(LC 7) Max Uplift2=-796(LC 8), 9= 811(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=5374/3073, 34=-5240/3075, 4-5= 4981/2826, 5-6=-2255/1421, 6-7=-2312/1390, 7-8=-2320/1368, 8-9=-3010/1736 BOT CHORD 2-14=-2825/5111, 13-14=-1110/2301, 12-13— 1043/2141, 11-12=-1528/2799, 9-11=-1528/2799 WEBS 4-14=-487/484, 5-14=-1581/2900, 5-13=-402/185, 6-13=-166/517, 8-12= 764/537, 8-11=0/257 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=14ft B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 796 lb uplift at joint 2 and 811 lb uplift at joint 9. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 0 WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1--7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additlonal temporary and permanent bracing MOW �p I OW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Cty, Ply 62' Grand Carillon III with porch T9680957 M11323 A7 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 1.641) S Apr 1 w zui b mi i ex industries, me. Mon Oct 1 r 1 U:4U:Ub zui b rage 1 ID:WSJgpGwalPpeur6hk9UjG5yuFUL-a7t5NETf53no?TCNwmtcnJfOEMeV2Pldn1 EP58ySYQu 1-0 8-10-10 140-0 20-M 25-11-15 34-0-0 5-0 oo 8-10-10 5-1-6 6-0-0 5-11-15 8-0-1 '1-0-0 5x10 = d nnF19 U10 = 2.00 12 5x6 = 2x3 11 LOADING (psf) SPACING- 2-0-0 CS'. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) 0.66 11 >623 360 TCDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(TL) -1.40 10-11 >291 240 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(TL) 0.41 7 n/a n/a BCDL 10.0 Code FBC2014/fP12007 (Matrix-M) LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1297/0-8-0, 7=1327/0-8-0 Max Horz2— 149(LC 6) Max Uplift2=-795(LC 8), 7=-812(LC 8) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5357/3035, 3-4— 4993/2805, 4-5=-2157/1368, 5-6=-2364/1410, 6-7- 2960/1697 BOT CHORD 2-11= 2785/5096, 10-11=-1430/2801, 9-10_ 1486/2746, 7-9=-1486/2746 WEBS 3-11=-412/418, 4-11— 1327/2588, 4-10=-810/415, 5-10= 166/455, 6-10= 636/444 Scale = 1:62.3 t2 I v 16 I 4x5 = PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 147 lb FT = 0% Structural wood sheathing directly applied or 2-2-0 oc purlins. Rigid ceiling directly applied or 4-3-13 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52fh L=34fh eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 795 lb uplift at joint 2 and 812 lb uplift at joint 7. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 0 WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11,1II-7473 rev. 10/032015 BEFORE USE ' Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW prevent is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabdcatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DS8-89 and SCSI Ruliding Component 6904 Parke East Blvd. Safety Information available from Truss Plate institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9680958 M11323 AB SPECIAL 1 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Apr 19 2016 MiTek Industries, Inc. Mon Oct 17 10:40:07 2016 page 1 ID:WSJgpGwalPpeur6hk9UjG5yuFUL-XW?sovVwdhl WEmM12Bw4skkNSAK2WNRwFLjWAOySYQs 1.0- 8-8-4 12-0-0 15-8-4 20-4-8 22-0-0 24-8-12 34.0-0 5-0- -0-0 8-8-4 33-12 3-8-4 4-8-4 1-71 2-8-12 9-3-4 1 -0-0 3x10 = 4.00 12 2.00 12 5x6 = 3x4 = 20 5 2x3 11 4x8 = 6 21 7 9r3 12 11 5x12 = 3x4 = Scale = 1:62.2 IIoI 4x6 = ' 10-6-4 9-10-4 1-7-8 12-0-0 ' Plate Offsets (X,Y)-- f2:0-2-2,0-0-71, 17:0-5-8,0-2-41, f9:0-2-6,Edge1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) 0.64 12-13 >642 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.87 Vert(TL) -1.36 12-13 >301 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress Incr YES WB 0.69 Horz(TL) 0.39 9 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight: 154 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-3-14 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1292/0-8-0, 9=1332/0-8-0 Max Horz2=129(LC 7) Max Uplift2=-794(LC 8), 9=-813(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3= 5337/3033, 3-4=-4970/2788, 4-20— 3801/2193, 5-20— 3801/2193, 5-6— 2464/1521, 6-21 =2472/1529, 7-21=-2472/1529, 7-8= 2492/1487, 8-9= 2808/1655 BOT CHORD 2-13=2785/5078, 12-13= 1698/3180, 11-12=-1158/2331, 9-11=-1432/2593 WEBS 3-13=-389/395, 4-13— 895/1665, 5-13=-291/796, 5-12=-894/538, 7-12=-303/452, 7-11=-228/474, 8-11=-408/405 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 794 lb uplift at joint 2 and 813 lb uplift at joint 9. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11,171-7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not � a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the Gobricatlon. storage. dellvery, erecffon and bracing of trusses and truss systems. seeANSI/TPII Quallt•/ Cdterlo, DSB-88 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9680959 M11323 A9 HIP 1 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Apr 19 2016 MiTek Industries, Inc. Mon Oct 17 10:40:00 2016 Nage 1 I D:_etCt cxC3ixVV?huls?ypJyuFU K-?iZE?FWYO_9MswxybvRJOxHgpalH FnB4U?T3iSySYQr 1 6-7-155 2-14 20-4 4-0-0 7-4-11 34-0-0 5-0 -8-3-0 6-7-13 5 1041 -0 6 3x5 = 4.00 12 4x4 = 3x4 2x3 11 4X8 = = 4 22 5 6 23 7 14 IL 3x8 = 3x6 = 6x8 = 3x6 = 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In ([cc) Udefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.24 Vert(LL) -0.17 13-15 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.49 Vert(TL) -0.42 13-15 >574 240 BCLL 0.0 Rep Stress Incr YES WB 0.85 Horz(TL) 0.02 13 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=687/0-8-0, 9=382/0-8-0, 13=1554/0-8-0 Max Horz2=-109(LC 6) Max Uplift2=-441(LC 8), 9=-262(LC 8), 13=-904(LC 8) Max Grav2=709(LC 17), 9=420(LC 18), 13=1554(LC 1) Scale = 1:60.1 3x5 = PLATES GRIP MT20 2441190 Weight: 156 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc puffins. BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1196/685, 3-4=-874/475, 4-22= 797/472, 5-22=-797/472, 5-6=-369/747, 6-23= 369/747, 7-23= 369/747, 7-8=-78/269, 8-9=-295/175 BOT CHORD 2-15=-543/1091, 14-15=-39/316, 13-14=-39/316, 12-13=-245/259, 11-12=-245/259. WEBS 3-15= 349/338, 5-15=-256/615, 5-13= 1162/752, 6-13=-260/229, 7-11= 156/325, 8-11= 387/359, 7-13=-762/448 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6fh Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.6b plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 441 lb uplift at joint 2, 262 lb uplift at joint 9 and 904 lb uplift at joint 13. 7) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. 0 N Im 6 Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERA NCE PAGE M11-7473 rev. 10/032016 BEFORE USE. Design valid for use only with Mffek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not �- a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary curd permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage. delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BC31 Building Component 6004 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9680960 M11323 GRA HIP 1 1 Job Reference (optional) Chambers I russ, Fort Fierce, FL --rip rips ,u —w it i an inuusuies, a c. -1 - 11 i a o U. , 1 D:_etC 1 cxC3ixVV? huts?ypJyuFU K-Tv7cDb W A91 H D U4 W 89cyYx9pg Dz6A_Cf DifCdEvySYQq • rt-0•Q 8-" 11-1-1 17-" ,18.6-0 22-2-2 26-0-0 34-0-0 35-0-0 1-0-0 8-0.0 3-1-1 5-10-15 1-6-0 3-8.2 3-9-14 8-0-0 Scale = 1:62.3 TOP CHORD MUST BE BRACED BY END JACKS, THIS COMPONENT IS TO BE USED IN ROOF DIAPHRAGM, OR PROPERLY CONNECTED CONJUNCTION WITH A RIGID DIAPHRAGM. PURLINS AS SPECIFIED. 4x4 = THIS DIAPHRAGM MUST BE CAPABLE OF TRANSFERRING ROOF LOADS TO THE GROUND 11 14 WITH NEGLIGIBLE LATERAL DEFLECTIONS. 9 7x10 % 6 17 6x10 4.00 12 4 3x6 19 3 = 13 16 5x 21 10 N1 2 22 23 N N O 29 28 27 26 25 24 3x6 l'I 3x6 = 6x8 = 3x6 = 6x8 —_ 44 = 3x5 = 6x8 = 8-0-0 i 11-1-1 18-6-0 26-0-0 34-1 a-n-n a-t-t 7-d-1F 7-9-0 a-0-0 Plate LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress incr NO BCDL 10.0 Code FBC2014/TP12007 CS1. DEFL. in (loc) I/defl Ud TC 0.90 Vert(LL) 0.10 24-35 >999 360 BC 0.44 Vert(TL) -0.19 24-26 >987 240 WB 0.96 Horz(TL) 0.02 22 n/a n/a (Matrix-M) PLATES GRIP MT20 244/190 Weight: 194 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-7-4 oc puffins. Except: BOT CHORD 2x4 SP M 30 1 Row at midpt 8-21 WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14 REACTIONS. All bearings 0-8-0. (lb) - Max Horz2=179(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 2= 376(LC 8), 27=-1146(LC 8). 26— 1470(LC 8), 22= 646(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=527(LC 13), 27=2197(LC 13), 26=2894(LC 14), . 22=1015(LC 14) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-561/338, 3-5=-306/839, 5-7=-584/1206, 7-8=-584/1206, 8-10= 584/1206, 10-12=-584/1206, 12-13=-584/1206, 13-15=-584/1206, 15-16=-584/1206, 16-18= 584/1206, 18-20= 2121/1203, 20-21= 2121/1203, 21-22=-2176/1197, 4-6= 173/256, 6-9= 134/313, 9-11= 114/371, 11-14= 200/419, 14-17= 102/280, 19-21= 151 /268 BOT CHORD 2-29= 195/591, 28-29=-143/463, 27-28=-143/463, 26-27=-772/440, 25-26=-393/630, 24-25=-393/630, 22-24=-1014/2010 WEBS 3-29= 457/1105, 3-27= 1643/836, 5-27= 769/636, 5-26=-537/346, 13-26=-934/608, 18-26— 2360/1437, 18-24=-782/1690, 21-24— 38/353, 4-5=-618/520, 19-20=-342/310, 14-15=-549/402 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6fh Cat. 11; Exp C; Encl., GCpl=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 376 lb uplift at joint 2, 1146 lb uplift at joint 27,'1470 lb uplift at joint 26 and 646 lb uplift at joint 22. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the puffin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). AD CA Standard WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MfrEKREFERANCE PAGE MII-7473 rev. 10/03,2015 BEFORE USE. ' Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage. delivery, erection and bracing of trusses and truss systems. seeANSi/TPI I Quality Criteria, DSE-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312. Alexandra, VA 22314. Tampa, FL 23610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9680960 M11323 GRA HIP 1 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL r.oqu a Apr I evlo MI nett InOUffirreJ, In.. K'N - i r r . a v I o F.U. c I D:_etC1 cxC3ixVV?huls?ypJyuFU K-Tv7cDbW A91 H DU4W 89cyYx9pg Dz6A_CfDifCdEvySYQq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-3=-54, 21-23=-54, 29-30=-20, 24-29=47(F= 27), 24-33= 20, 3-11=-126(F=-72), 11-21 =-1 26(F=-72) Concentrated Loads (Ib) Vert: 29=-641(F) 24=-641(F) 0 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/012015 BEFORE USE. ' Design valid for use only With MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MITek` Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the 6904 Parke East Blvd. fabrication. storage. delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, OSS-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9680961 M11323 GRB HIP 1 1 Job Reference (optional) Chambers Truss, Foil Pierce, FL i.ovo s Apr iv zv i o Mi T eK mousmes, iu, moo i , r 1 o .0- an i ID:SrRaEyyrgO4M78G4raW BLWyuFUJ-Tv7cDbWA91 HD U4W89cyYxgpiuz4F_CMDifCdEvySYQq r1-0-8-0-0 13.8-0 17.0.0 20-4-0 26.0-0 34-0-0 1-0-0 8-0-03-4-0 -43 —0 5-8-0 8-" 1-" , m 6 5x8 MT18HS = 4X10 = 4.00 12 2x3 14x6 = 2x3 11 3 23 4 5 6 7 24 5x8 MT18HS= Scale = 1:60.1 4x5 — 3x6 II 4x6 _ 6x10 = 6x10 = 4x6 = 3x6 II 4x5 — 8-0-0 13-8-0 20-4.0 26.0-0 34-0-0 8-0-0 5-8-0 6-8-0 5-8-0 8-0-0 0 ', Im a Plate Offsets (X Y)-- f2:0-2-2 Edgel 13:0-5-4 0-2-e1 15:0-3-0 Edge], f8'0-5-4 0-2-81 (9'0-2-2 Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.79 Vert(LL) 0.16 16 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(TL) -0.27 14-16 >912 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress Incr NO WB 0.98 Horz(TL) 0.07 9 n/a n/a BCDL 10.0 Code FB02014ITP12007 (Matrix-M) Weight: 153lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-7-9 oc purtins. BOT CHORD 2x4 SP M 30 POT CHORD Rigid ceiling directly applied or 5-8-1 oc bracing. WEBS 2x4 SP No.3 `Except` WEBS 1 Row at midpt 8-13, 6-13 4-14,7-13: 2x6 SP No.2 REACTIONS. (lb/size) 2=1296/0-8-0, 13=3993/0-8-0, 9=510/0-8-0 Max Horz2=-90(LC 6) Max Uplift2_ 871(LC 8), 13=-2549(LC 8), 9=-369(LC 8) Max Grav2=1479(LC 13), 13=4684(LC 15), 9=563(LC 14) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3514/1878, 3-23— 2062/1226, 4-23— 2062/1226, 4-5=-2062/1226, 5-6=-2062/1226, 6-7=-126512545, 7-24=-1265/2545, 8-24= 1265/2545, 8-9=-692/331 BOT CHORD 2-16= 1655/3336, 15-16=-1676/3398, 14-15=-1676/3398, 12-13=-246/658, 11-12= 246/658, 9-11=-225/595 WEBS 3-16=-402/1155, 3-14=-14311700, 4-14=-847/699, 7-13= 886/720, 8-13= 3505/1836, 8-11= 403/1157, 6-14=-1431/2780, 6-13=-3151/1776 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuit=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6fh Cat. II; Exp C; Encl., GCpi=0.18: MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 871 lb uplift at joint 2, 2549 lb uplift at joint 13 and 369 lb uplift at joint 9. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. I 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3_ 54, 3-8=-131(F= 77), 8-10= 54, 16-17=-20, 11-16=-49(F=-29), 11-20=-20 0 WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MIF7473 rev. 10103MOIS BEFORE USE Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not � a truss system. Before use. the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabricatlom storage, dellvery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSE-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312 Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch I T9680961 M11323 GRB HIP 1 1 1 I Job Reference (optional) Chambers Truss, Fort Pierce, FL LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 16=-641(F) 11=-641(F) IMU 5 Apr 19 2U1 b MI r eK lnauslrles, Inc. man VCr 1 / 1 V:4u:lu Lu i o Page [ I D:SrRaEyyrg04M78G4raW BLWyuFUJ-x5h_QxXowcP45E5KjJTnUMMteNQUjfcMxJyAnLySYQp WARNING - Verily design parameters end READ NOTES ON THIS AND INCLUDED mrrEK REFERANCE PAGE Ml1-7473 rev. 101012015 BEFORE USE. ter. ' Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the appllcablllty of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quailty Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9660962 M11323 J2 MONO TRUSS B 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Apr 19 2016 Mirek industries, Inc. Mon Oct 1 7 10:40:10 2016 Page 1 1 D:xl?zSlzTbJCDII rGPH 1 QukyuFUI-x5h_QxxowcP45E5KjJTnUMM2INYIjuxMxJyAnLySYQp 1.0-0 2.0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) -0.00 7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(TL) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=37/Mechanical, 2=143/0-8-0, 4=21/Mechanical Max Horz 2=67(LC 8) Max Uplift3=-30(LC 8), 2=-131(LC 8), 4=-3(LC 5) Max Grav3=37(LC 13), 2=143(LC 1), 4=29(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Scale =1:7.9 PLATES GRIP MT20 244/190 Weight: 8 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; 13=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 30 lb uplift at joint 3, 131 lb uplift at joint 2 and 3 lb uplift at joint 4. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 10/032015 BEFORE USE. ' Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the 6904 Parke East Blvd. fabricallom storage, delivery. erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, OSS-89 and SCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carlton III with porch T9680963 M11323 J4 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL f.C4u s Apr is zur o Mi 1 ak inausrnes, inc. Won va i r i 0:40. i 0 201 o r„ye 1 I D:PDYLfd_5MdK4MSQTz7ZfRxyuFU H-x5h_WowcP45E5KjJTnUMMOdN W ejuxMxJyAnLySYQp 1-0-0 1 4-0-0 Scale = 1:11.2 3x4 = LOADING (psi) SPACING- 2-0-0 CSI. DE FL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.22 Vert(LL) -0.01 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.17 Vert(TL) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 n/a n1a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight: 14 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=79/Mechanical, 2=229/0-8-0, 4=39/Mechanical Max Horz2=104(LC 8) Max Uplift3=75(LC 8), 2=-171(LC 8), 4=-2(LC 8) Max Grav3=79(LC 1), 2=229(LC 1), 4=60(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; 13=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.16; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 75 lb uplift at joint 3, 171 lb uplift at joint 2 and 2 lb uplift at joint 4. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M/rEK REFERANCE PAGE MY-7473 rev. 10/0=015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not � a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mffek' Is always required for stability and to prevent collapse with possibbe personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 3 1 Z Alexandria, VA 22314. Tampa, FL 33610 Job russ Truss Type Oily Ply 62' Grand Carlton III with porch T9680964 M11323 �J,6 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Apr 19 2016 Mi I ek industries. Inc. peon Oct 1 7 10:40:11 2016 Page 1 I D:tP6jtz_j7xSx_c_Mi4uz9yuFUG-PHEMdHYOgvMOgXH i_10av6FnozSLAWAzhkJnySYOo 1-0-0 6-0-0 Scale = 1:14.8 3x4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.55 Vert(LL) 0.04 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.42 Vert(TL) -0.09 4-7 >790 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014ITP12007 (Matrix-M) Weight: 20 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=120/Mechanical, 2=321/0-8-0, 4=54/Mechanical Max Horz2=142(LC 8) Max Uplift3=-117(LC 8). 2=-218(LC 8) Max Grav3=120(LC 1), 2=321(LC 1), 4=89(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; VUlt=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 117 lb uplift at joint 3 and 218 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. Q WARNING - Verity design parameters end READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MIP7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not � a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the 6904 Parke East Blvd. fabilcatlon. storage. delivery. erection and bracing of trusses and truss systems, seeANSt/TPI I Quality Criteria, DS13--89 and BCSI Building Component Tampa, FL 33610 Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Job Truss Truss Type city, Ply 62' Grand Carlton III with porch T9680965 M11323 J8 MONO TRUSS 20 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 1_" 3x4 = 7.640 a Apr 19 2016 MI I ek Industries, Inc. Mon Uct It 1 U:4U:11 ZUl6 I -age 1 I D:tP6jtz-j7xSx_c_fXi4uz9yuFU G-P H EMdHYQgvMOgXH 1 _10avgTniQSLAW AzhkJnySYQo LOADING (psf) SPACING- 2 0-0 CS'. DEFL. in (loc) Udefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) -0.10 4-7 >972 360 TCDL 7.0 Lumber DOL 1.25 BC 0.78 Vert(TL) -0.27 4-7 >350 240 BCLL 0.0 ` Rep Stress Incr YES WB 0.00 Horz(TL) 0.01 2 n/a n/a BCDL 10.0 Code FBC2014ITP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=164/Mechanical, 2=411/0-8-0, 4=68/Mechanical Max Harz 2=180(LC 8) Max Uplift3=-160(LC 8), 2=-265(LC 8) Max Grav3=164(LC 1), 2=411(LC 1), 4=118(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Scale = 1:17.7 PLATES GRIP MT20 244/190 Weight: 26 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-11-4 oc puriins. SOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 160 lb uplift at joint 3 and 265 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. 0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED mrrEKREFERANCE PAGE 01-7473 rev, 10/0302015 BEFORE USE ' Design valid for use only wllh MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must vedfy the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' prevent Is always required for stability and to prevent collapse with possible personal injury and property darnage. For general guidance regarding the fah-tcat'ion. storage. delivery. erection and bracing of trusses and truss systems, s,eANSI/TP1I Quality Criteria, D-S8-89 and 6CS1 Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 62' Grand Carkon III with porch T968D966 M11323 KJ8 MONO TRUSS 4 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 1-5-0 7.640 s Apr 19 2016 MiTek Industries, Inc. Mon Oct 17 10A0:11 2016 Page 1 I D:Lcg54J?LuEancmZr4Qb7W MyuFU F-PH EMdHYQgvXxjOgXH 1_1 OavAingZSFRWAzhkJnySYQo 113-0 3-11-12 Scale = 1:20.8 3x4 = 5 3x4 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 ` BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2014/TPI2007 CSI. TC 0.26 BC 0.26 WB 0.43 (Matrix-M) DEFL. in Vert(LL) 0.05 Vert(TL) -0.11 Horz(TL) 0.02 (loc) I/deft Ud 7-10 >999 360 7-10 >999 240 6 n/a nta PLATES GRIP MT20 244/190 Weight: 44 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 9-0-4 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=207/Mechanical, 2=482/0-11-5, 6=556/Mechanical Max Horz2=244(LC 8) Max Uplift4=-207(LC 8), 2=-312(LC 8), 6=-277(LC 8) MaxGrav4=250(LC 13), 2=482(LC 1), 6=574(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1090/498 BOT CHORD 2-7= 662/1072, 6-7= 662/1072 WEBS 3-7=0/309, 3-6=-1177/727 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. Il; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) na 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 207 lb uplift at joint 4, 312 lb uplift at joint 2 and 277 lb uplift at joint 6. 7) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used In the analysis and design of this truss. 8) In the LOAD GASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-2= 54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-4= 152(F= 49, B=-49), 8=0(F=10, B=10)-to-5= 56(F=-18, B— 18) ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEKREFERANCE PAGE Mll-7473 rev. 10/03P1015 BEFORE USE Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual buiding component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabricatiom storage. delivery. erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Crilerlo, DS6-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria VA 22314. Tatrpa, FL 33610 Symbols PLATE LOCATION AND ORIENTATION 3/4 Center plate on joint unless x, y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-'/11' - I - For 4 x 2 orientation, locate plates 0-1/& from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Ingtalling & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 2 TOP CHORDS 0 a' O U a- O 0 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek® All Rights Reserved MITek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 ® General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI, 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other Interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design Is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to comber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.