HomeMy WebLinkAboutBuilding Plan8'-l" T.O.B.
It
12"
0'-0" = Finished Floor
1
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12 Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" 26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D wood screws with self sealingwasher at 12" O.C. max spacing over ASTM D
(type 2) 30 lb felt underlayment Installed with min. 4' side laps and 6" end (type 2) 30 lb felt underlament Installed with min. 4p side laps and 6" end
laps fastened with corrosion resistant tin caps and with I 5" ring shank nails laps fastened with corrosion resistant tin caps and with 1.25" ring shank Halls
Zspaced G" o.c. at all laps and two staggered rows 12" o.c. field. Attach spaced 6" o.c. at all laps and two staggered rows 12" o In field. Attach
deck to trusses using attachment detail on this sheet deck to trusses using attachment detail on this sheet
12 12
4 SLOPE SLOPE 114
8'-1" T.O.B.
2"
H.
C
5/8" thick light textured
stucco on typical concrete 5/8" thick x 8"w cut O
block construction coral finished stucco bands
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _
O'- O" Finished Floor
5/8" thick x 8"W cut Finish Columns with 5/8" thick light textured Flnlsh Column=-L-U,.�hl
coral finished stucco bands 5/8" thick cut coral stucco on typical concrete 5/8" thick cut a
finished stucco bands block construction finished stucco bands 0gcf
LEFT ELEVATION REAR ELEVATiON
SCALE: 1/4' = 1'-0" ELEVATION N O T E S. SCALE: I/4" = 1'-0"
- Overhangs at i'-O" unless otherwise noted on Roof Plan
ROOF Itch at �f:12 unless otherwise noted Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
p 26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
_ /^ wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 4IIG51.12 A n ( changes to this plan Shall be submitted to the architect (type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D for approval i n w r l t l n g prior t 0 Starting C O n S t r U G t l O n . spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end / I deck to trusses using attachment detail on this sheet
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails - R e t u r n ALL S t u C C 0 Bands Into Window Or D o or .
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detal on this sheet
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb Felt using 8d nails. Substrate
to be 19/32" COX Plgwood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
12 SLOPE �{
SLOPE 4
2"
8'-I" T.O.B. H
12" 5/8" thick x 8"W cut 2"
H. coral finished stucco bandsEl 1:1
H.
3 '
3 5/8" thick x 8"W cut
Z.
coral finished stucco bands
�5/8" thick light textured
stucco on tgplcal concrete
block construction
- - - - - - - - - - - - - - - - - - - - - - - - - 0'-0" = Finished Floor Finish Columns With 5/8" thick light textured
5/8" thick cut coral
finished stucco bands stucco on typical concrete
block construction
RIGHT ELEVATION
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Skylights
Opening
Type
NOA/FL
NUMBEg
Product
Model
Manufacturer
Glees
Attachment method
zSpuation
Date
Design Pressure
of Approved Tests
1,2,3
14
FL# 1"1499.2
Single Hung
Series 185
MI Windows
and doors
q. x 3 tltcona air ppn tion at mex
rom sach corner end L o.c. tharaa7'tar throng �F buck Into eo rd
filled CMU wall maintaining min 2.5" edge distance in strict adherence
to the product a proval.
± 60 par
A
16-0330.02
Overhead
Garage Door
g
Model 824/BII
9'-4" max. width
I6'-0" max height
g
DAB
Hate x rc to concrete rc with s cs mt
Il a5 bar vert. eang e./9' x 6' Hilt, HLC Sleeve Michas at a' o.c.
th 1.25' dui. uaaher amh mra 1' edge do erica. inatell track to back
sing (D 5/IL' a 5%a' full thread leg rcrema m sech bracket mmntmnme
mra or 1.5' edge distance - GC to atrittlg adhere to product approval
raVide l/IL' w ut an idler a us.
10-9-21
+ 50.0/-60.0 sf
p
B
FL# 1LL14.1
Fiberglass
DesignPro/
Smoth Pro
Jeld-Wen
Elco 1/4" dia. tapcon with mrn 1.25" embedment at 3" max
from corners and 11.5" o.c. max thereafter in head and jambs.
+ 50.0 PSF
C
FL# 15332.2
Sliding Glass
g
Door
Series 420
MI Windows
and doors
dia. x cone w enetratian at max.
rom each corner and 'l"'o.c. al &Zile row t9ierearter through
PT Buck into solid filled CMU wall maintaining min 2.5' edge distance
in strict adherence to the product approval.
+ 48.2 PSF
-
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
EExspiration
Date
Design Pressure
of Approved Tests
Mullions
FL# 15353.8
CM-18531
vertical mullion
Mi Windows
and doors
For CMU use (2) 1/4" x 2 3/4' topcona with min 1 1/4" embedment
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
self tapping screws per clip as shown in product approval.
+ 118.9 PSF
1200E
FL# 11651_I2
SY Crimp
Metal Roofing
Gulf Coast Su I
in y
and manufacturing
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws wit self sealingwasher at 12" o.c. max spacing over ASTM D
(t a 2) 30 lb felt underlment installed with min. 4P side laps and 6" end
gP g p
laps fastened inch corrosion lapdto resistant tin cape and with 1c. ring shank Wade
at all late and two staggered rows 12" o.c. rn field. Attach
spaced 6" trusses
deck to trusses using attachment detail on roof plan
- 108.5 PSF
Siding
Stucco on Block
Soffit
FL# 12198.3
Model T4 12" vented
Vinyl Soffit
Kaycan
Install using 2" x 2" battens at G" o.c. screwed to soffit framing using
#8 x 3" wood screws at each truss. Install soffit to battens using
O. 2" dia. x 1.5" Iona rinQ shank nails with / " dia. head.
+
55.0/-35.0 PSF
Hurricane
Panels
Flu 15014.2
24 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13" o.c. at the top
± 45.0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record )
SCALE: 1/4" = 1'-0"
2" x 4" top plate 1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at W' o.c.
base -board ------\ 111 ,2" x 4" P.T. bottom plate
F:RCNT ELEVATION
\ 4" concrete slab with fibermesh
OR
6"xC 410/10 WWM on 6 mill Visqueen
over
clean compacted termite treated
fill
Interior Non -Bearing Partition
nts
Braden t
Braden AIA, PA
Wgnne
Building Corp.
Architects
- Planners
S.E. Coconut Avenue
The
G d Carlton
Telel
(712) 287-8258
r d n
Fax
: (112) 281-8283
Spanish
Lakes
E-mail:
bradenaia comcast.net
St. Lucie County Florida
Stuart. FL
34996 UAAC000032
1=1I-Jr-lr-1,'1
1-MQ
0=0
lri�
ON
E
�F-MIW
SCALE: 1/4" = 1'-0'
--- 5/8" thick x 8"W cut
coral finished stucco bands
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 'I-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: 10 mph ultimate
Mean Roof Height: II'-O" Roof Pitch:4.I2
PY'F-f'0'04TCH
Internal Pressure Coefficient: ±0.18
Subjectabilitg to damage from: Weathering: Negligible Termites:Vern Heavu
Width of Roof End Zone: 3'-4" Wind Speed: 145 mph ultimate
Wind Exposure Classification: C
I
Adjustment factor for Exposure Height: 1.21 x 0.4 = 0.124 ASD design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+0.6WL; 0.6DL+O.610L
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.6/-32.4 psf
Roof Zone: 2. +20.4/-51.0 psf
Roof Zone: 3. +20.4/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET)
5.
f Zone I
WWall all Zone. +35.8/-31.8 paf
WaIIRso
4
Components t Cladding Wind Pressure (NET) on Garage Door. +32.0/-40.3par
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided)
Ea = Roof Zone 2
es
Walls Zone 5
Are Components an Cladding Det� Provided? Yes
END ZONE
Minimum Soil Bearing Pressure: 2,500 psi, Presumptive: X By Teat: psi
This Building Shall Have the Following;
®= Corner Zones
APPROVED SHATTERS: X IMPACT GLASS: BOTH: NEITHER:
Roof Zone 3
ROOF LIVE LOAD: S1 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: J-6- par FLOOR DEAD LOAD: 1O per
JOB ADDRESS:
MODEL: Date Drawn Revisions
5-9-I1
GARAGE Drawn by:
RIGHT C.C.U.
Checked by:
D.R.B.
Sheet Comm #
1. 12-27
OF 5
File Copy
�FLCCR
FL,4N
CRASH POST DETAIL
TYPICAL NOTES: SCALE 114" = 1'-0"
N.T.S.
I. Contractor to verify ALL notes and dimensions prior to
36" high by 4" diameter
steel crash post. Floor
proceeding with work.
Flange With 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements.
graion bolts into
3. ALL Lumber to be used as Beam, Rafters, etc... to have
ala (3/8"t 50 kai steel plate)
a minimum 1,400 P.S.I. fiber stress.
4. No dissimilar metals to touch.
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
%' %2"
ALL Concrete used for vertical filled cells, Cont. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
6. Drywall be leveled and attached to bottom chord
° 2y2"
at ceilings shall
e
5
1.
of trusses with screws per FBC R702.3.
ALL wood in contact with concrete shall be pressure treated.
° °
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10.
Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
II.
Contractor to Provide a 2'-8" wide door at one bathroom for
accessibility requirements. %11 ,%2"
M2-handicap
12.
Lowest finished floor to be set by Governing Building Department
surveyor to set in field.
13.
Separation between residence and garage shall be per FBC R302.6
14.
Door between garage and residence shall be 1-3/4"t 20 min. rated door
Water Heater
15.
Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC
R302.9.1
I6.
Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC
R302.9.2
11,
All exposed attic insulation materials installed on attic floors shall have a critical radiant
Masonry Beam
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
1" x 6" P.T. Buck Walled to
block with case hardened nails
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior to door attachmen
with F.B.C. R316 - see permit info box of code edition
18.
G psum board material shall conform to ASTM C36, C�19, C4-15, C514, C630, C931
C�60, C1002, C1047,C1111, C11718, C1278, C1395, or C139( and shall be installed
according to the following: (FBC R102.3.5)
Dr wall
Thickness
Location
Orientation
Framing
Member
Max. spacing
of fasteners
Nail sizing options for
of drywall into
Spacing
Maximum
installation
wood Framing members
Nails
Screws
2" x min. thickness
Ceiling
Perpendicular
24"
.1"F12"13ga
13/BOIRong with 19/64" head
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
Walls
Either
16"
8"0,080"
dia. x 1 5/8" long with
Direction
15/64" head
OR
G psum board nail 0.080 dia.
x 5/8" with 9/32" head.
Ceiling
Perpendicular
24"
12"
130a 15/8" lloong with 19/64" head
O
0,098" diameter x 1 3/8" long
annular -ringed or dd cooler nail
OR
Walls
Either
16"
8"
I6"
0.092" dia. xx 1 '1/8" long with
Direction
1/4" head
OR
Gypsum board nail 0.0915" dia.
x 11/8" with 19/64" head.
Install SGD thru buck into block with 3/16" tap -con with
1 1/2" penetration at C o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/14" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product ap�ro
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, 4136.l and A137.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1178 and lnstalled I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21_ Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanging smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11661.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(tgpe 2) 30 lb felt underlagment installed with min. 4' side laps and (" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor 1 1 each truss 12 PRE-ENGINEERED TRUSSES
with (IO) IOd x I I/2" nails
( 24" o.c.) supporting Max. 4 �- at 24"o.c. TYPICAL
18101ba. uplift (shop drawings by manufacturer)
Aluminum Drip �7longtgalv.
V'-1/2"
\R-30 blown fiberglass
Edge f Faacia in bottom chord of trusses
drywall with smooth finish
2" x 6" Sub -Fascia Two rows of beam block filled with concrete
and (1) #5 bar Cont. in each row. Substitute
Kagean full o vent vmprecast lintel filled with concrete and (U #5
using I/8" die shank x bar Cont. For bottom row over openings
roofing nails with 3/8".
product approval - see chart sheet #1 1/2" drywall over I" x furringg
strips al 14" o.c. with R4.1 fi-roll
-insulation on typical 8" Block walls
5/8" thick light textured All drywall to be installed per FBC R-702.3.1
stucco on typical concrete 7 and shall meet all pertaining ASTM codes.
block construction � Mortar to be Type "M" only proportioned per FBC R60�.1
and Mortar Jonts shall comp g with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
45 bar vert. w/ qL
30" overlap Fill cell with concrete and
at each filled cell (U #5 bar vert. (typical).
Max. spacing shall not exceed
Wood 48" unless otherwise noted
Base see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"xb" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
"
Grade .r
I1 1-1 III 1 III 1=1 1-1 1=� �_
iI4111I =_ -III III1 1 II=
„Ill 1„11 I 111 - - 114" x 14" Concrete footing
14" with (2) #S bars Cont. and #5
TY F I C ,4 L SECTION transverse bars at 48" o.c.
Scale : 1/2" = l'-O"
Head
fixed door
sliding door
AREA CALCULATIONS
Living A/C =
I4.4�
sq.
ft.
Front Porch =
141
sq.
ft.
Rear Porch =
200
sq.
ft.
Garage ==
321
sq.
ft.
Total Under Roof=
2108
sq.
ft,
2" VTR
JIL
I
I
I
21' VTR
Masterr�� JL
Bath I
2.
Lev. I
2"
Lev.
4" 1 2" VTR
No
shwr.her. To Septic
PLUMBiNG RISER
i" x 6" P.T. Buck nailed to
block with case hardened nails
prior to door attachment
Masonry Wall
Bottom Track Typtcal Flooring
Sill Install SGO thru buck into
block with 3/14" tap -con with
S l 1 d 1 n g Door Detail 11/2" penetration at 6" o.c. max.
from each corner and 20." O.C. max
thereafter at Jambs per product approval) a m b
At Masonry Wall NTS
UjInd ow
ScheduI&
Mark
Size
Rough Open,
Window Description
PRESSURE
ZONE
I.
4'-5%"x 5'-3%8"
54%8"x 63%4"
Single Hung
ZONE 4
2,
6'-2 %a"x 5'-3 %"
15" x 63 %4"
Single Hung
ZONE 4
3.
2'-2" x V-2 1/2"
2l%2'`x 385la"
Single Hung
ZONE 4
4.
4'-5%"x �{'-2'/a"
54%;'x 5�fYa"
Single Hung
ZONE 4
ALL
Windows to be aluminum
windows w/ tint
and mullions per
elevations.
ALL
windows to withstand
pressures In permit info box on
sheet i
ALL
windows in bathrooms to
be tempered
All
rough opening
dimensions
to be verified by contractor
with
manufacturers specs prior to construction
Door Schedule
Mark
Slze
Rough Opening
Door Description
PRESSURE ZONE
A
9'-0" X I'-O"
108" x 84"
Overhead Garage Door
ZONE 4
B
31-0" X 6'-8"
41 %4"x 83%"
Fiberglass Panel - Inswing
ZONE 4
C
6'-0" X 6'-8'°
_14" x 81 %," or' ace :`�"
Sliding Glass Door
ZONE 4
D
2'-0" X 6'-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24" x 81 %2"
E
2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel
F
5'-0" X 6'-8"
Solid Core - Wood
- 6-P4nel - Bi-Fold
G
2'-8" x 6'-8" x 1 %;'
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X 6'-8"
Solid Core - Wood
- 6-Panel
J
2'-6" X b'-8"
Solid Core - wood
- 6--Panel - Bi-Fold
K
2'-8" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified by contractor
With manufacturers specs prior to construction
0
0
0
(14
i
En
N
12" x 12" concrete column block filled
with concrete and (2) #1 bars vert. tied
Into lintels above
Covered Porch
EGRESS
12' - 8"
[DII 111 11011E91 EObo
N
1
1 MASTER
8'-0" to 9'- " A.F.F. BEDROOM
Vaulted Ceiling 8'-0" A.F.F.
Flat Ceiling
CAR AT
Rg0M
1
1
1 19'-8" Rod Shelf
_ I I Vanitg to
v 34 i2„hlgh-
I i 1
N w I I
8'-O" to 9'-8" A.F.I . 2" x t knee -wall -oSET O
Vaulted Ceiling below counter top W p
I
DINING I
I
ROOM 1
9
8"
LRod
aF
a
Shelf
1
2
,r
F-Dw-7
Vanity to be
34 %2"high I
ill -0 3/4 1
9%'4" (41")
I
1
High Wall
KITCHEN
I 1
- - 1-1/2"
O
0`ver�ang =
-
8'-O" A.F.F. I
o
N
Fiat Ceiling -
`o
'-O"
E
Upper ca mats to
4'
extend over Ref.
A T H
I
�en"�
e
_
_
Rod 8 shelf
8'-0" A.F.F.
u V V Flat Ceiling
SECOND
° BEDROOM
O00
ro
v
BATS
N
®
I
W
e
-II Batts eulatia
4"4 Steel
Ballard
,„
.` N_detai qn this
sheet
a$
22" x 54"
if
Ij
Attie Access
Provide auto
l
L_____�
with light I
closer
a a
l
22„
c
`" 6' o„ 4" S GO rip
m Panel
B a
E ERGEN Y
J
I
L°
O � O O
EGRESS
O
if
oo�o oo°
3'-11, O
0
°
COVERED
12" x 12" concre a column block filled
ith concrete and (2) #1 bars vert. tied PORCH
into h tels above
:a
6" '-6"
6'
2"
e
2'-8"
2'-8"
9'-6"
3'-4"
5'-4"
34'-O"
Install windows thru buck into
block with 3/14" tap -con with
1 1/2" penetration at V o.c. max.
from each corner and 20." o.c. max
thereafter at ,lambs and 20" o.c. max.
Exterior race at head and sill per product approval
of wall Buck to be I" x 4" PT
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
block with case hardened nails ON ALL JAMB, HEADER, AND
D e t a I I at W I r d ow s prior to window attachment SILL BLOCK PRIOR TO BUCK
INSTALLATION
NTS
GARAGE
8'-4" A.F.F. O
Flat Ceiling
N
r-----------------i
Block wall in
garage to be
struck block
I I
I I
I I
I
I I
I I
W
D-
N
I
filler
A/C o
v
Meter
Attach buck to block wall with
1/4" dia. Elco conc screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max From each corner thru
Exterior face 2" x 6" PT Buck
of wall
E
varies
151
ALV D
P#8Wood screws thru jamb into buck
at each hinge and 16" o.c. max and
Detail at Door prior to door attachment
NTS
File C opv
STRUCTJRAL NOTE 4:
L
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
BEARING CAPACITY. IF ANY SUB -SOIL, MOCK OR NON -UNIFORM
q.
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
PROPER ENGINEERING DATA FOR DESIGN.
2.
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
IO.
DESIGN LOADS ARE AS FOLLOWS:
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
ROOF (DL+LL) = 41 PSF
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 91
3-
EXPOSURE ="C"
POISON SOIL AND COVER W/ 4 MiL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION,
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 4X6 10/10
IL
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-14, t
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 30'1 STEEL.
WELDED WIRE MESH REINFORCING ON 4 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY).
12.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, SLOCKOUTS, ANCHOR
LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED
5-
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
MACHINE COMPACTED TO A MINIMUM OF 2500 PSI IN AREA OF
13.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
BUILDING CONSTRUCTION
FOOTING: 3"
6.
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
BEAMS: I-I/2"
�•
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
14,
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
15.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF I600 PSI
8.
GARAGE FLOORS TO BE SMOOTH TROWEL FiNISH (SLOPPED PER
14.
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
PSI OF N0.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
FOUND�47CN �=L/4N
17• ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
1. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revlslon
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and 1 45 bar vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings upp to 5'—II" wide.
Provide (2) filled cells on each side Of openings from 6'—O" to 9'—II"
and Provide (3) filled cells on each side of openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
7. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A—Ib and
A-35 specifications. ALL Anchors to be A-301 steel.
`- Provide a minimum of 3" concrete protection at footings and
1-1/211 concrete protection at beams for ALL reinforcing bars.
#5 bar vert. w/
30' overlap -
at each filled cell
G
�I 01DIE
14"
TYPICAL PnnTIN
4" concrete slab with flbermesh OR
VxV 910/10 WWM on 10 mil Vrsqueen over
clean compacted termite treated fill
=1111—III
1.1111—
14"w x 14"d concrete monolithic
footing with (2) #5 bars Cont.
DETAIL
J SCALE 1/2" = 1'-0"
4" concrete slab with fibermesh OR
6 x6 #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
Step per
JD foundation foundation plan
10" (2) #5 bars cant. bottom steel
12"'
DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
12" x 12' concrete column
block filled with concrete
and (2) #1 bars vert. tied
into lintels above
Top of Tooter
14, below finished floor
COLu
Verify house slab
height in field
30"x30"AC concrete
column footing with (4)
#5 bars each way
3
30"
OOTING DETA
SCALE 1/2" = 1'-0"
Thicken edge to 8"x8"
with concrete and
one 45 bar continuous
GRADE
co
SCALE: 1/4" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete,
if soil area is disturbed after Initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termiclde in annular space between sleeve and pipe.
4" concrete slab with frbermesh OR
4"x4" #10/10 WWM on 10 mil Vrsqueen over
clean compacted termite treated fill
=/')=e'I I r—I A = fir- /' � r'�t- n II
SCALE 1/2" = 1'-0"
#5 bar vent. w/
30" overlap
at each filled cell
Adjust curb height
based on gar. floor 4" concrete slab with frbermesh OR
slope. Vx6" #10/10 WWM on 10 mil Vrsqueen over
#5 bar in curb clean compacted/termite treated fill
'% �� t n,_rv- 9 r- r- a'-\
QI E I III
14"w x 14"d concrete monolithic
footing with (2) #5 bars cont.
14"
F Sj GARAGE CURB DETAIL
SCAT
/2" = 1'-0"
2" x 6" PT wood secured with \
3/8"dia. x 4" anchor bolt at 18" o.c.
overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED �,-S
IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MOOPEL,
Filled Cell Masonry Column With One
#5 From Footing To Tie Beam
Conic. Fill To Be 3000 PSI
See Floor Plan For Location
Sinqle Filled Cell Column
NTS
Filled Cell Masonry Column With One
45 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden t Braden AAA, FA
Architects — Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (112) 287-8283
E-mail: bradenaiaacomcast.net
Stuart. FL 34994 #AAC000032
a
v
34'-O"
20'-0"
L°
° I -----00 O° iiii iiii °O OO
— L° I--- — — — —— Or— ----
---
4
°
O
J F1------�
I � — J�
I
Filled cell under
girder above FI I
O
I
4„
O
-
Rear Patio/Slab
I � u1 �to be poured separate -7
from the house
slab.
I o I�
Io
Thicken footing to 1
24"w x 14"d x 24"L
o C I under filled cell FI I
° 9 Q ° under girder bearing.
-
° r — — — —— — — -- — — —__� I
I F I '� t
o
Rear Patio/Slab to
° I be flush with bottom of
't)
sliding door recess. I
I slope 1/2"
uo0
`r
_i
1
�u_
-a 1
4' I
°
_I I
I
-i I
'I
° I
I
IFI to
°
1 32'-8" °
I I
01
4" concrete slab with flbermesh OR I
H.B.
6"xC' #10/10 WWM on 4 mil Visqueen over �O
I clean compacted termite treated fill
I 7
o
°I
FII
I
F-
-il
i
I
' o
FI
4, _ 0"
00 al
i
I FI
/
r W- l 1 4"(0 Steel Ballard I
®filled w/ Concrete
v
°
OI
'J
a
I �°o to
2
11 aQl�1
11 v�N I
uIQ
~=to
I �T"
I I I
�E�
a
r I E,,
o° ° 3
I I ° o.o
_
cn
° I q3 I �-
FI O I
/ / I 0 0 `U '
°
^,
Q�
-*- - U
° i i i 0 ° - �Q
I
a
''
En
I
o
r
I�
r 8 t----_Recess for Fs
°
°� ° —�
--—F-4 --- — — — — ° O Garage Door ° °
°
L-
3 F
®
b
II'-6"
6'-2"
�\12" x 12" concrete column block filled
with concrete and (2) #1 bars vert. tied
into lintels above
LUG( nine Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
FOOTING
SCHEDULE
Mark
Srre
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 12"0
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
F
30"
x 30" x 10D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
8"W
x 8"D
THICKEN SLAB EDGE
WITH I #5 BAR CONTINUOUS
Q14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB a 0'-0"
MODEL: Date Drawn Revisions : Sheet
5-9-11 Comm #
GARAGE Orawn by:
RIGHT C.C.U. 3, 12-21
Checked by:
D.R.B. OF 5
Ile Copy
ROOF SHEETING
ATTACHMENT DETAIL
I.
2.
I Ilr Ii 111 will Nall �JIGG —
Minimum Screw Size
uu Ili iy
= 48 x
ailui rn ,nui i. i-.— •—••�•
2"
3.
Minimum Sheathing Thickness
19/32" COX Plgwood
4.
Use nails or screws
based on
pressure for roof stated
3
in permit info box
on these
plans
for zone
<e
Area
Edge
Field
Fastener
Pressur
Zone 1
6"
6"
Sd ring shank
45 par
Zone 2
4"
6"
8d ring shank
16 psf
Zone 3
4"
4"
8d ring shank
84 psf
** Zone 3a
1 6"
1 6"
48 wood screw
112.5 psf
** Use nails
or screws based on pressure
for
roof stated
in permit
info box on these plans for
zone
3
Concrete
/ Lintel
Column
Verlfy with Plan
12"x 12"
ilumn Block
Reber
Reber 48 Bar Dia.
Min. Overlap
to Lintel Attachment
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steel into continuous
beam block steel.
Provide Cast -Crete =
SUS-OB/OT precast —
lintel set in mortar
Min. 8" Bearing --
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calls for It.
divide PT Buck
.ached per jamb
ails Into filled c
4" Pre -cast
SIII
Filled Cell
11 95 bars with min. 48 bar
rs overlap in filled cell. Tie
ell steel into continuous
steel.
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blockinp to vertleg of
truss with IOd x 1.5' nails at 4" o.c.
Install Simpson MGT into wall using
5/8" dia, threaded rod set min. 12"
into wet beam and (22) IOd nails Into truss
3LOCKING DETAIL
)ER STRAPPING
TER BEARING POINT
NTS
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D type 2 paper backed
wire lath Walled tosubstrate through one layer of
ASTM D TgPe 2 felt paper using ad Walla. Substrate
2
to be 19/32' COX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
ark
Size and
Description
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
Two rows of beam
block filled
with concrete and u5 bar
26 ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5"
wood screws with self sealing washer at 12 o.c. max spacing over ASTM D
BI
continuous in each
row. Hook
Vert. bar over tou bar with
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
#5 90° bend bar
with a 10"
min. Id at to bar.
p p
laps fastened with corrosion resistant tin caps and with 1.25 ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12" c.c. in field. Attach
deck to trusses using attachment detail on this sheet
Additional Precast Lintel
#5 bars
rLEAR
r�:-t; .,` , •• ,, y:,ry ...1.:.r. 9 C
Lintel
Length
Bar
Length
Clear
Span
n n
A
Bars
n
B
Bars
I'-6"
2,43
none
2'-10"
2'-8"
2'-2"
2,43
none
8F8-OBAT 8P8-IB/IT are-IS/2T
4'-0"
3-10"
2'-8"
2,u3
none
Additional
4'-6"
4'-4"
3'-2"
2,#3
none
#5 bars.
'.i i!•'.`
CLEAR
ne Row of "H"
•J` Block Above
5'-4"
5'2"
4'-O"
2,#3
none
2,#4
none
'•
,,Precast Lintel r`a y
4•}::.r;,
6'-6"
6'-4"
5'-4"
2,44
none
1 Additional
'
"
T-O"
6'-2"
2,#5
none
#5 bars
�'----y i`----'�
813I6-IB/IT 8FI6-IB/2T
"
1'-10"
-r-O"
2,45
none
NOTES:
ALL reinforcing steel is grade 60.
I. min. coverage of steel=1.5"
2. min. bearing required a ea. end=8"
3. standard for reinr. ateel=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Window
or Doo
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
"
Bottom
Steel
Size
Top
Steel
Size
Max.
Gravdg
Load
(PLF)
Max.
UpIdL
Loed
(PLF)
Max.
Lateral
Load
(PLF)
L22
2'-2"
3'-6"
SFS-ci
I
#5
3069
1569
1024
1_31
T-6"
4'-0"
BPS-OBAT
I
#5
2561
1343
1L3
L45
4—se
I 5-10"
arS-OB/IT
I
#5
1105
1 909
354
L50
51-0"
1 6'-V
8P8-OBAT
1
#5
1238
1 835
121
L60
6'-8.
1'-4.
8FS-OB/IT
I
#5
1011
127
534
L80
8'-0"
T-4"
8FS-IS/2T
1
45
2
#5
152
591
512
L90
9'-0"
10'-V
8F8-IB/2T
1
#5
2 1*
643
530
401
L90B
9'-0"
10'-6"
81=I6-8/2T
ONE
1
#5
2 #5
1533
1183
401
1-I00
10'-0"
11'-4"
8P8-6/2T
1
#5
2 #5
582
494
452
LIOOB
10'-0"
11'-4"
BFIL-IB/2T
ONE
I
#5
2 tt5
3LL
028
452
L120
12'-O"
13'-4"
8FS-I5/2T
1
#5
2 #5
411
928
324
L120B
IT-O"
13'-4"
81=I6-5/2T
ONE
1
#5
2 1 #5
1015
110
324
L140
14'-0"
15'-4"
8FI6-IB/2T
ONE
1
#5
2 #5
1250
409
259
L160
16'-0"
11'-4"
81=8-I5/2T
I
#5
1 2 #5
300
192
194
L160B
16'-0"
IT-4"
81=I6-I13/2T
ONE
1
#5
1 2 45
960
Soo
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal 4
hurricane anchor at each truss
with (10) IOd x I I/2" Walla
( 29" o.c.) suplft Max.
181016a. up ift �
Aluminum Drip '
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end truss
With (2) 10d I
at each web
Aluminum Drip �� "
\ /
Edge t Fascia
I/2" thick stucco on 3/e" hi -rib lath
attached to horizontal and vertical wood
2"
framing with nails or staples to provide
2" x 6' Sub-Fascl
no Ivan than-3/4" penetration Into
horizontai wood framing and 3/4" penetration
into vertical wood framing members
Kagcan full o vent vinyl sorrit installed
using 1/8" dia shank x 15" long galv.
roofing nails with 3/8' dia. head per
product approval - see chart sheet #I
5/8" thick light textured
stucco on tgpical concrete
12" x 12' concrete column
block construction
block filled with concrete
Varies - see plan
and (2) #1 bars vert. tied
35 bar Yert. w/
into lintels above
thicken edge to Vx8"
30" overlap
with concrete and
at each filled cell
one #5 bar continuous
BEYOND
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Top of footer
IL" below finished floor
Step per foundation plan
a Slope per foundation plan r
W
Poured Concrete or
concrete block wall
Poured Concrete or \
concrete block wall
Concrete Anchors f
Manufacturers Specs
Flush Mounte
W ood
Base
e Anchors Per
Lurers Space
I/9"Max.
utter Detall
Alumm"m Panel
Sizes per manufacturer
- See Tupical Stud Detail
1/e" x 3/32" Wing Nut w/
appropriate washer end spacing
per manufacturer's Details
0)
R
Stud Detail
Stud w/ Die Cast Zinc NTa
Nickel Plated Wing Nut
yr
nts
Brace Gable end
with 2" x 4" SYP #2
art back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEERED WOOD TRUSSES
> ® 24"o.c. TYPICAL
( shop drawings bg manufacturer )
(
c
\R-30 blown fiberglass
in bottom chord of trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) #5 bar cant, in each row. Substitute
precast lintel filled with concrete and (U #5
har cant. for bottom row over openings
1/2" drgwall over I" x furringg
strips at 16" o.c. with R4.1 fi-fall
nsulation on typical 8" Block walls
_ All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
o Mortar to be Type "M" only proportioned per pBC R601.1
and Mortar joints shall comply with FBC R,01.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
Simpson HETA 20
hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. uplift
Strap
truss to wall using Simpson
MGT
with
5/8" dia.
threaded rod with min 12"
embedment
into
beam either wet set or in
epoxy
with
(22)
ETA 2c�j
IOd nails into truss. Add
truss leg per detail on
blocking
this sheet
to
IRS "Ir-1
11
10
wo
I
WAAFAMFAAr
FEN
1
9. ma
11400
{a
e3
=3
L
+r
X
�
�
r
OU
N
m
w4_r.0
w_ 4_
I—
d
L
= 0
N di
aC
N
u
Q
OD
E
_
04
cn m
u
ty
4
L
1 �
Brace Gable end
with 2" x 4" SYP #2 min.
--art back nailed to bottom
of top chords using (2) IOd
nails at each truss
Fill cell with concrete and O L
(1) #5 lbar Vert. (t6pinot ex /4 I �
48" unless notherwise noted ed
see foundation plan notes for — OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
spacing at openings — ROOF PITCH AT +{:12 UNLESS OTHERWISE NOTED ON THIS SHEET
4" concrete slab with fibermesh OR
Vxb" #10/10 WWM on 6 mil Visqueen over — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
/clean compacted termite treated fill — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
O STARTING CONSTRUCTION
III=1 � IIIIIIII=1 I I I=1 I I I1 I 111�=�1 I C I III 1=1 I I I ,III 1—
' 'IIII-IIII=IIII-11�11�11=IIII �I�I �I�I I•,IIII—
III -0
T p[Cal Section at Front Fora
ARCHITECT FOR APPROVAL IN WRITING PRIOR T
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
�nPrl l�n��n �,112v�Y Tn 7211�S C'OMPANY PRIOR TO TRUSS CONSTRUCTION
aI : _ i-v
Braden Braden ,41,4, PA
W(�nne Building Corp.
MODEL:
Date Drawn :
Revisions :
Sheet
Comm #
Architects - Planners�'-9-11
411 S.E. Coconut Avenue
The Grand Carlton
RIGHT GARAGE
drawn b }:
12 — 2
Tel : (172) 281-8258
-
C.C.U.
-
Spanish Lakes
Fax : (172) 281-8283
Checked by:
E—mail: bradenalaocomcast.net
St. Lucre County Florida
D.R.B.
01= 5
1 Stuart. FL 34994 #AAC000032
PANEL
"A"
Poles
BR
Load
Wire
Description
circ#
circ#
Description
Wire
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
1
2
AHU
#10
3.5 kw
30
2
3
4
2
30
4.5 kw
#lo
40 gal. water HTR
5
6
Ran a
#6
12.0 kw
50
2
7
e
1
20
1.8 kw
#12
Pump
9
10
Dr er
#10
5.0 kw
30
2
II
12
1
20
1.5 kw
#12
13
14
Dishwasher
U12
1.2 kw
20
1
1
20
1.5 kw
#12
Microwave
Is
16
Refrigerator
#12
L2 kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
11
is
Recepts
#12
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Recepts
#12
20
1
1
20
1.2 kw
#12
Clothes Washer
21
22
Recepts
912
20
1
1
20
0.81 kw
#12
Garage Door Opener
23
24
Recepts
#12
20
1
1
20
1A kw
#12
25
26
Recepts
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
#12
20
1
1
20
#12
General Lighting
29
30
Recepts
#12
20
1
1
20
#12
General Lighting
31
32
Recepts
912
20
1
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
20
1
I
20
#12
General Lighting
35
36
Bathroom GFI
#12
20
1
1
20
#12
Smoke Detectors
31
38
General Lightng
412
20
1
1
20
#12
Bathroom GPI
39
40
General Lighting
#12
20
1
5 are
41
42
spare
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting, ,(3, .watts sq. ft:)
Small ,Appliance. Circult(s),.„,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
Range .......... .................. ......... ................
.Refrigerator
Microwave
Dish Washer
. Clothes, .Washer ..............................................
......................................
Clothes..Dryer................................................
Water Heater
.Water Pump ..................................................
.Garage Door Opener ....................
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1,200
1,200
1
1,500
1,500
1
1,200
1,200
1
1.200
1,200
1
5,000
5,000
1
1
4,500
4,500
1,800
1,800
1
810
810
Total
Watts
31,415
First 10000 Watts 9100%
10,000
10,000
Remainder 21,415 ®40%
1
O
10,944
Electric Heat or A/C 10,000 645%
1
10,000
10,000
Calculated Load
Watts
30,966
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical S mbcl Legend
S
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Eyeball Recessed
P6
Push Button Switch
,.,-
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
O-
Wall Mounted Light
�c
Waterproof ground fault circuit
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
Fc-m-1
Carbon Monoxide Detector
'�&
Flood Light
Q
Thermostat
m
Electrical Panel
©
Central Vac
IEE�
Electrical Meter
QS
Smoke Detector
M
Ceding Fan
©
Television Jack
Telephone Jack
AC DISC
I A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
SPKR
Speaker Hook -Up
i❑
Intercom
H.B.
Vent thru
Sofi'1t ___
PATIO/SLAB
I
I
GR =AT
RgOM
I
I
I
Center Registers
169 CFM on ceding fan 169 CFM
IOxlOxl I Ox10xl
DINING
ROOM
E
232 CFM
12xbxl
SECOND
BEDROOM
12xl2x8 i �
B/A �-
163 CFM
IOxlOx6
MASTER
BEDROOM
143 CFM
IOxlOx6
x12x9
B/A
��F ------ ----- all
12xl2x9
LOSET B/A
8 CF
r.�
fil
153 CF'
12xl2x1
W'
-
-
A-Acc- ss
I
with
L
- - - - --
t �
COVERED
PORCH
= JUNCTION BOX TO SUPPORT A BAN
O = THERMOSTAT LOCATION
C
B/A = BALANCED AIR
Electric Notes:
SCALE: 1/4" = 1'-0"
I.
2.
Use copper wire only, no aluminum.
Provide and were all required smoke detectors.
li. It is not the Intent of these tans to show ever minor detail
p
3.
Contractor to verifg location of electrical
of construction. The contractor shall furnish and install
service and provider,
all items for a complete electrical system and provide all
4.
ALL paddle fans shall be on a rheostat.
the requirements necessarg for the equipment to be placed in
S.
ALL bath and kitchen receptacles to be GFI protected.
proper working order.
6.
ALL exterior outlets to be WP/GFI protected.
S. All work shall be done 1n accordance with the N.E.C. and
8.
Recessed cans be installed per NFPA requirements.
shall complg with all local codes and ordinances, and shall
8.
AFCI receptacleess are required in all rooms except
meet all standard requirements of the local electric utilit y
Kitchen, Bathrooms, and Garage.
and telephone company.
9.
10.
A/C Return Air Balance Must comply w/ FBC RMI602
A/C Brant Imes that are run thru slabs must be
9. The electrical s stem shall be coin letel and effective)
sleeved in PVC
in
rounded as required b the latest edition of the N.E.C.
9 q y
II.
ALL A/C Equipment shall complg with energg calculation
20. All material shall be new and shall bear underwriters'
12.
All work shall be performed bg a licensed electrical
labels where applicable.
contractor, the completed system shall be fullg operative.
13.
Contractor shall pay for all fees, permits, testing, and
21. All equipment and panel sizes shall be verified before
inspections including blower testing where required.
ordering. The contractor shall provide circuit routings to
14,
All work shall be coordinated with other trades to avoid
suit the Job conditions.
interference with the progress of construction.
15_
All required insurance shall be provided for protection
22. Furnish and install all fixtures as called for on the plans
against the public habilitg and property damage for the
or as selected bg others.
duration of the work.
16.
Contractor shall guarantee all materials and Workmanship
23. All raceways and pipes placed in or through any concrete
free of defects for a period of not less than two years from
slab shall be spaced a minimum of three diameters of the
the date of acceptance or certificate of occupancy, or one
largest conduit or pipe from ang other service.
gear from closing sale of house.
Correction of defects shall be completed without additional
24. All exposed wire below 9'-1" shall be installed in metal EMT
charge and shall include replacements or repair of ang
conduit.
other phase of installation that mag have been damaged.
25 Dryer Vents to be installed per FBC RMIS02
Z
ZV-
___Vent_thru�
Soffit
150 Amp f l kMeter
Panel
GARAGE
r----------------- i
I I
I
I I
I I
I I
I I
I I
I I
I I
I I
I
I I
A/C disc.
#2/0 Aluminum feed
AMP
I '/,• Conduit PANEL
M TE
AHU
2" PVC ( FPL
2" rigid service FPL Bare #6 coppe wire
to #5 cont. rear in slab
ELECTRICAL RISER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
H.B.
Exhaust Duct
Thru Soffit
Wire For
,
Front Post
Light
PATIO/SLAB
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
Install oulet
under disc.
t shown for
clarity
;--LECTF-,,IC/4L PL/4N
SCALE: I/4" = I'-O"
6'-3"
Post Light with
I Photo cell
Attic Venting Calculations FBC 2309.7
Total Attic Space = 212,4 sq. ft.
Venting Ratio I/ISO = 14.16 sq. ft. required
Provide A Continuous Vented Soffit