Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProduct Approval UnderlaymentsVMS
BCIS Home I Log In I User Registration I Hot 7bpics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search
Florida
�
`„I Product Approval
USER: Public User
utrre da,:�a
t. rr:.irJ' ecrram
Product Approval Menu > Product or Application Search > Application List > Application Detail
64. +•4
FL #
FL2569-R23
x
Application Type
Revision
Code. Version
2020
Application Status
Approved
Comments
Archived C
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
memathieu @soprema. ca
Authorized Signature Marc -Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819)478-2400 Ext3327
memathieu @soprema. ca
Quality Assurance Representative
Jean -Francois Cote, Ph.D.
Address/Phone/Email
1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Category 'File COPY
Roofing
Subcategory
Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
0 Validation Checklist - Hardcopy Received
Certificate of Independence FL2569'R23 COI 2021 01 COI NIEMINEN.2df
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D4601 2012
ASTM D4798 2011
FM 4474 2011
FRSA/TRI Sixth Edition 2018
TAS 103 2020
UL1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
07/29/2021
Date Validated
08/03/2021
Date Pending FBC Approval
08/09/2021
Date Approved
10/12/2021
Date Revised
02/04/2022
Summary of Products
FL #
Model, Number or Name.,-
�,:
2569 1, �� -
Sop rema%8of7Unde`�raymentsdfo' ,
Selftadheeing roof}underlayments u `
"
use (n FB0HVFiZ iunsiiictloris :
it � x � " - * ' �? R
Limits oftJse ,r - --
Installation Instructions`ARpP
for use f6 HVHZ Yesiu xirl x �7, �, r
Aroved for use,'outside'HVHZ Nli -'
FL2569 f1i23 IT�2023 07 .29 F NAC'ER.tSOPREMA HVHZ FL2569-
R23 z�;+ia�
Impact -Resistant. N/A
pdf
Verified By Robert Nieminen PE 59166
'Design Pressure N/A''` Fn� fit.,+r } y _
5ifor
Created by Independent Third Party: Yes
Otter 72i3fer to ER Sectlorr Limits ofaUser
' --
Evaluation^,Reports
GAF`
-�
FL2569 R23 021 07'w22 FIN7kL ER SOPREMA HVHZ FL2569-
R23 df —c_-.
-Created by'3ndepelident Third -Party- Yet
2569.2
Soprema Roof Underlayments for
Self adhering roof underlayments
use in FBC non-HVHZ jurisdictions
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2569 R23 II 2021 07 29 FINAL ER SOPREMA NON -
HVHZ FL2569-R23.gff
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nleminen, P.E. PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.)
Evaluation Reports
The design pressure noted herein pertains to
FL2569 R23 AE 2021 07 29 FINAL ER SOPREMA NON-
HVHZ FL2569-R23.pd
underiayment systems used beneath the roof systems.
Refer to ER Section 5.8.3 for details.
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. CCopyria t 2007-2013 State of Florida, :: Privag,Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic
mail to this entity: Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
1W-191 OW71 500-1. M
Credit ..
SecurityM is rR rcS•
NS
ENGINEER EVALUATE
SOPREMA, Inc.
1640 rue Haggerty
Drummondville, Quebec J2C 5138 Canada
(819) 478-2400
TEST
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
CONSULT
Evaluation Report 3m-SOPC-2I-FBCER.A-Rl
FL2569-R23 (HVHZ)
Date of Issuance: 04/19/2021
Revision 1: 07/29/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code, High Velocity
Hurricane Zone sections noted herein.
DESCRIPTION;- SCIPREMA Roof Underfayments,for.use in FBC HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of
our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s),
the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report
relative to updated Code requirements with each Cade Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
Nsw1:,
a The facsimile seal appearing was authorized by Robert Nieminen, P.E.
on 07/29/2021. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
©2019 NEMO ETC, LLC
MEMO I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: SOPREMA Roof Underlayments, as produced by SOPREMA, Inc., have demonstrated compliance with
the following sections of the 7th Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions
of Use set forth herein.
Section ;,
=Pro a ,. ,.
Standard,.
Year
TAS 110
Material standard
ASTM D1970
2015
TAS 110
Material standard
ASTM D4601
2012
TAS 110
Material standard
TAS 103
2020
TAS 110
Accelerated Weathering
ASTM D4798
2011
-Entity -
.Examination
Reference`'
Date '-
ERD (TST6049)
TAS 103 (MS)
S43530.02.14-1-R1
02/21/2014
ERD (TST6049)
ASTM D1970 (QC)
S44870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (MS)
S44870.04.14-4
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
540540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
ASTM D4798
SOPC-SC8520.04.14
04/27/2015
NEMO (TST6049)
ASTM D1970 / TAS 110 (QC)
SOPC-SC8970.08.15-R1
04/25/2018
NEMO (TST6049)
Tile Slippage
4S-SOPC-18-002.09.18
09/21/2018
NEMO (TST6049)
ASTM D4601(MS)
4q-SOP-I9-SSMBB-01.A
03/11/2019
NEMO (TST6049)
ASTM D4601(OH)
4q-SOP-I9-SSMBB-01.B
03/11/2019
NEMO (TST6049)
ASTM D4798/1)1970 (OH & MS)
45-SOPC-18-002.05.19.A
05/31/2019
NEMO (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW-I9-SSLAP-01.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-20-SSUDL-01.A
01/07/2021
NEMO (TST6049)
ASTM D1970 (MS)
4j-SOPC-2I-SSUDL-01.A
04/19/2021
PRI (TST5878)
ASTM D1970 (MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
NEMO
Traceability
FBC Cross -Listing
07/28/2021
UL, LLC (QUA9625)
Quality Control
MLA File No. R16814
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
UL, LLC (QUA9625)
Quality Control
Florida BCIS
Current
M
4.1
4.2
4.3
4.4
PRODUCT
Product
Material'' Standard
Plants)
Description. '.
LASTOBOND TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric surfaced, SBS
TAS 103
modified bitumen roof underlayment
SRS TopShield DEFENDER TU
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric surfaced, SBS
FRSA/TRI 09-18
modified bitumen roof underlayment
Tri-Built S/A HT TU
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric surfaced, SBS
Underlayment
TAS 103
modified bitumen roof underlayment
LASTOBOND Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS modified
bitumen roof underlayment available in two widths; 36 and
45 inch
NEMO ETC, I.I.C. Evaluation Report 3m-SOPC-2I-FBCER.A-RI
Certificate ofAuthoriration #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ)
SOPREMA Roof Underlayments Revision 1: 07/29/2021
Page 2 of 7
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
4.17
4.19
OMEMO etc.
PRODucT DESCRIPTION:
Product
Material"Standard
Planf(s)
Description
RESISTO SA SMOOTH PLY 40
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS modified
bitumen roof underlayment
LASTOBOND Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof underlayment
LASTOBOND Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS modified
bitumen roof underlayment available in two widths; 36 and
45 inch
LASTOBOND Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof underlayment
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof underlayment
LASTOBOND Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced, SBS
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
LASTOBOND Smooth Seal HT
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced, SBS
Wadsworth, OH
modified bitumen roof underlayment
Tri-Built Smooth HT S/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced, SBS
Underlayment
Wadsworth, OH
modified bitumen roof underlayment
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced, SBS
Smooth Seal HT
Wadsworth, OH
modified bitumen roof underlayment
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced, SBS
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
TRI-BUILT Sand-R SA Shingle
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced, SBS
Underlayment
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
PrimeSource Grip -Rite Eave
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced, SBS
& Valley Protector
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
SRS TopShield ICE & WATER
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced, SBS
DEFENDER
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH.,-,...., r
RESI5T0 let 4R4,""
A$TM D197�0 t3`
Drum ond6ille;QC
. MSSmodified
self. a'dheriltg gl Ss, at retnfoiced, and; surfaced, SBS'!i
brtutnen
;cry
fulfport;
"
roof underlayment
T
Wa S'o 6o
---
MODIFIED SOPRA-d `
ASTM D4601, Type II
Gulfport, MS
Fiberglass reinforced, SBS modified asphaltic base sheet
Wadsworth, OH
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance
unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance
with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I413CER.A-111
Certificate'ofAuthorization #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ)
SOPREMA Roof Underlayments Revision 1: 07/29/2021
Page 3 of 7
MEMO I etc.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam
plastic insulation.
5.5 SOPREMA Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE I: ROOF COVER'OPTIONS
f8C Seetionr
TAS110(S10j, ,:
PAS US
TA5230(S23J,, .
RAS 118,119 & 120
RA5133'
TA5110(SII) .'
RAS 130 '
Clay and -Concrete' Tiler-.
.
Underla ment --
y
Asphalt
Shingles
Mechanical 1 Adhesive
=
Metaf .
Slate'or Slate"
Type
Wood .
Attach .Set,
Shingles;,
LASTOBOND TU HT, SRS TopShield
DEFENDER TU, Tri-Built S/A HT TU
Yes
Yes
Yes
Yes
Yes
Yes
Underlayment
See 5.6.1
LASTOBOND Shield, Pro HT-N, RESISTO SA
SMOOTH PLY 40
Yes
No
No
Yes
Yes
Yes
LASTOBOND Shield HT, Pro HT-S
Yes
No
No
Yes
Yes
Yes
EnviroShield
Yes
No
No
Yes
Yes
Yes
LASTOBOND ECO, RESISTO LB1236, TRI-
BUILT Sand-R SA Shingle Underlayment,
Grip -Rite Eave & Valley Protector,
Yes
No
No
No
Yes
Yes
TopShield ICE & WATER DEFENDER,
RESISTO LB1244
LASTOBOND Smooth Seal HT, Tri-Built
Smooth HT S/A Underlayment, Grip -Rite
Yes
No
No
Yes
Yes
Yes
Smooth Seal HT
5.6.1 Adhesive -set the is limited to use of the following underlayment / tile -adhesive combinations.
TABLE 1A:ACLOWABLE,UNDERLAYMENT/TILE-AUHESIVE'COMBINATIONSl '
Underlayment `, ,
Adhesive .. -
Florida ProductApp`rovaF
LASTOBOND TU HT, SRS TopShield DEFENDER
TU, Tri-Built S/A HT TU Underlayment
Dupont "Tile BondTM' Roof Tile Adhesive"
FL22525
ICP Adhesives and Sealants "Polyset® AH-160"
NOA 20-1124.07
I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval far Overturning Moment Resistance Performance.
NEMO ETC, I.I.C. Evaluation Report 3m-SOPC-2I-FBCER.A-R1
Certljicote ofAuthorizotion #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ)
SOPREMA Roof Underlayments Revision 1: 07/29/2021
Page 4 of 7
O.MEMO I etc.
5.7 Allowable Substrates:
TABLE 2 `SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS .
Substrates (designed to. meet wind loads for project) "
'Underlayment _
Application
Type:,.:?rimer
Matdrial(s)
LASTOBOND Shield, LASTOBOND Pro HT-N,
Deck
ASTM D41
structural concrete
RESISTO SA SMOOTH PLY 40, LASTOBOND
Insulation
(Optional) Elastocol Stick Zero
Dens Deck Prime or SECUROCK
Shield HT, LASTOBOND Pro HT-S,
Gypsum -Fiber Roof Board
EnviroShield, LASTOBOND TU HT, SRS
TopShield DEFENDER TU, Tri-Built S/A HTTU
Underlayment, LASTOBOND ECO, RESISTO
self-
LB1236, TRI-BUILT Sand-R SA Shingle
adhering
Underlayment, Grip -Rite Eave & Valley
Base Sheet
(Optional) Elastocol Stick Zero
ASTM D226, Type II felt
Protector, TopShield ICE & WATER
DEFENDER, RESISTO LB1244, LASTOBOND
Smooth Seal HT, Tri-Built Smooth HT S/A
Underlayment or Grip -Rite Smooth Seal HT
LASTOBOND TU HT, SRS TopShield DEFENDER
TU, Tri-Built S/A HT TU Underlayment,
Existing sand -surfaced, glass -fiber
RESISTO LB1236, TRI-BUILT Sand-R SA Shingle
self-
Existing
RESISTO EXTERIOR PRIMER
surfaced, mineral -surfaced or
Underlayment, Grip -Rite Eave & Valley
adhering
substrate
film -surfaced roof underlayment*
Protector or TopShield ICE & WATER
DEFENDER
*Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a
question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, RESISTO
LB1236, TRI-BUILT Sand-R SA Shingle Underlayment Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact
RESISTO technical support.
5.8 Attachment Limitations:
Refer to Section 6
5.9 Exposure Limitations:
11ABLE3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Mawmum
InstallationTyge
Exposure(days),'
LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite
Mechanically attached
30
Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244
LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield
HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT
Mechanically attached
90
S/A Underlayment or Grip -Rite Smooth Seal HT
LASTOBOND TU HT, SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment
Mechanically attached or
adhesive -set tile roof system
180
NEMO ETC, I.I.C.
Certificote of Authorization H324SS
7TH EDITION (2020) FBC HVHZ EVALUATION
SOPREMA Roof Underlayments
Evaluation Report 3m-SOPC-2I-FBCER.A-R1
FL2569-R23 (HVHZ)
Revision 1: 07/29/2021
Page 5 of 7
O.N EMO I etc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck the roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4, TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE:INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope : -
Flat
Max. 30-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Double -tile stacking method, as shown below 6:12
LASTOBOND TU HT,
SRS TopShield
DEFENDER TU, Tri-Built
S/A HT TU
Lugged
Underlayment
Ow
6.1 SOPREMA Roof Underlayments shall be installed in accordance with SOPREMA published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3
6.3.1
Approved Assemblies:
Deck Type 1t.; " UVood;-Non=Insulated `
Deck Description: Min.19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. .
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a staggered grid -pattern between the overlaps.
Cap Ply: LASTOBOND TU HT, SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment, self -adhering
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
NEMO ETC, I.I.C. Evaluation Report 3m-SOPC-2I-FBCER.A-R1
Certificate ofAuthorizotion #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2S69-R23 (HVHZ)
SOPREMA Roof Underlayments Revision 1: 07/29/2021
Page 6 of 7
MEMO etc.
6.3.2 Deck Type 1:Wood, Noh-lnsulate,'d' `
Deck Description: Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch D.C.
in a staggered grid -pattern between the overlaps.
Cap Ply:
LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT,
LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT
TU Underlayment, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite
Smooth Seal HT, self -adhering.
Surfacing:
FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood
shakes or wood shingles.
6.3.3
Deck Type 1:`,.
_
."Wood; Non lnsulated�
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a staggered grid -pattern between the overlaps.
Cap Ply:
LASTOBOND ECO, RESISTO LB1236, TRI-BUILTSand-R SA Shingle Underlayment, Grip -Rite Eave & Valley
Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244, self -adhering.
Surfacing:
FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4
herein for products and production locations having met codified material standards.
UL LLC—QUA9625; (414) 248-6409; Karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, I.I.C. Evaluation Report 3m-SOPC-2I-F6CER.A-R1
Certiyleote of Authorizotion #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ)
SOPREMA Roof Underlayments Revision 1: 07/29/2021
Page 7 of 7