Loading...
HomeMy WebLinkAboutProduct Approval UnderlaymentsVMS BCIS Home I Log In I User Registration I Hot 7bpics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search Florida � `„I Product Approval USER: Public User utrre da,:�a t. rr:.irJ' ecrram Product Approval Menu > Product or Application Search > Application List > Application Detail 64. +•4 FL # FL2569-R23 x Application Type Revision Code. Version 2020 Application Status Approved Comments Archived C Product Manufacturer Soprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON -US 00000 (819)478-2400 memathieu @soprema. ca Authorized Signature Marc -Etienne Mathieu memathieu@soprema.ca Technical Representative Marc -Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville, NON -US 00000 (819)478-2400 Ext3327 memathieu @soprema. ca Quality Assurance Representative Jean -Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888) 811-3145 jfcote@soprema.ca Category 'File COPY Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/21/2023 Validated By John W. Knezevich, PE 0 Validation Checklist - Hardcopy Received Certificate of Independence FL2569'R23 COI 2021 01 COI NIEMINEN.2df Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D4601 2012 ASTM D4798 2011 FM 4474 2011 FRSA/TRI Sixth Edition 2018 TAS 103 2020 UL1897 2015 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/29/2021 Date Validated 08/03/2021 Date Pending FBC Approval 08/09/2021 Date Approved 10/12/2021 Date Revised 02/04/2022 Summary of Products FL # Model, Number or Name.,- �,: 2569 1, �� - Sop rema%8of7Unde`�raymentsdfo' , Selftadheeing roof}underlayments u ` " use (n FB0HVFiZ iunsiiictloris : it � x � " - * ' �? R Limits oftJse ,r - -- Installation Instructions`ARpP for use f6 HVHZ Yesiu xirl x �7, �, r Aroved for use,'outside'HVHZ Nli -' FL2569 f1i23 IT�2023 07 .29 F NAC'ER.tSOPREMA HVHZ FL2569- R23 z�;+ia� Impact -Resistant. N/A pdf Verified By Robert Nieminen PE 59166 'Design Pressure N/A''` Fn� fit.,+r } y _ 5ifor Created by Independent Third Party: Yes Otter 72i3fer to ER Sectlorr Limits ofaUser ' -- Evaluation^,Reports GAF` -� FL2569 R23 021 07'w22 FIN7kL ER SOPREMA HVHZ FL2569- R23 df —c_-. -Created by'3ndepelident Third -Party- Yet 2569.2 Soprema Roof Underlayments for Self adhering roof underlayments use in FBC non-HVHZ jurisdictions Limits of Use Installation Instructions Approved for use in HVHZ: No FL2569 R23 II 2021 07 29 FINAL ER SOPREMA NON - HVHZ FL2569-R23.gff Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nleminen, P.E. PE-59166 Design Pressure: +N/A/-150 Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) Evaluation Reports The design pressure noted herein pertains to FL2569 R23 AE 2021 07 29 FINAL ER SOPREMA NON- HVHZ FL2569-R23.pd underiayment systems used beneath the roof systems. Refer to ER Section 5.8.3 for details. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. CCopyria t 2007-2013 State of Florida, :: Privag,Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mail to this entity: Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 1W-191 OW71 500-1. M Credit .. SecurityM is rR rcS• NS ENGINEER EVALUATE SOPREMA, Inc. 1640 rue Haggerty Drummondville, Quebec J2C 5138 Canada (819) 478-2400 TEST NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 CONSULT Evaluation Report 3m-SOPC-2I-FBCER.A-Rl FL2569-R23 (HVHZ) Date of Issuance: 04/19/2021 Revision 1: 07/29/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code, High Velocity Hurricane Zone sections noted herein. DESCRIPTION;- SCIPREMA Roof Underfayments,for.use in FBC HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Cade Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 Nsw1:, a The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 07/29/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC MEMO I etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: SOPREMA Roof Underlayments, as produced by SOPREMA, Inc., have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section ;, =Pro a ,. ,. Standard,. Year TAS 110 Material standard ASTM D1970 2015 TAS 110 Material standard ASTM D4601 2012 TAS 110 Material standard TAS 103 2020 TAS 110 Accelerated Weathering ASTM D4798 2011 -Entity - .Examination Reference`' Date '- ERD (TST6049) TAS 103 (MS) S43530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970 (QC) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) 540540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) ASTM D4798 SOPC-SC8520.04.14 04/27/2015 NEMO (TST6049) ASTM D1970 / TAS 110 (QC) SOPC-SC8970.08.15-R1 04/25/2018 NEMO (TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018 NEMO (TST6049) ASTM D4601(MS) 4q-SOP-I9-SSMBB-01.A 03/11/2019 NEMO (TST6049) ASTM D4601(OH) 4q-SOP-I9-SSMBB-01.B 03/11/2019 NEMO (TST6049) ASTM D4798/1)1970 (OH & MS) 45-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021 NEMO (TST6049) ASTM D1970 (MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021 PRI (TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 NEMO Traceability FBC Cross -Listing 07/28/2021 UL, LLC (QUA9625) Quality Control MLA File No. R16814 12/10/2015 UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020 UL, LLC (QUA9625) Quality Control Florida BCIS Current M 4.1 4.2 4.3 4.4 PRODUCT Product Material'' Standard Plants) Description. '. LASTOBOND TU HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, SBS TAS 103 modified bitumen roof underlayment SRS TopShield DEFENDER TU ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, SBS FRSA/TRI 09-18 modified bitumen roof underlayment Tri-Built S/A HT TU ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, SBS Underlayment TAS 103 modified bitumen roof underlayment LASTOBOND Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch NEMO ETC, I.I.C. Evaluation Report 3m-SOPC-2I-FBCER.A-RI Certificate ofAuthoriration #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 2 of 7 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.19 OMEMO etc. PRODucT DESCRIPTION: Product Material"Standard Planf(s) Description RESISTO SA SMOOTH PLY 40 ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment LASTOBOND Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch LASTOBOND Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH LASTOBOND Smooth Seal HT ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Wadsworth, OH modified bitumen roof underlayment Tri-Built Smooth HT S/A ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Underlayment Wadsworth, OH modified bitumen roof underlayment PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Smooth Seal HT Wadsworth, OH modified bitumen roof underlayment RESISTO LB1236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH TRI-BUILT Sand-R SA Shingle ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Underlayment Gulfport, MS modified bitumen roof underlayment Wadsworth, OH PrimeSource Grip -Rite Eave ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS & Valley Protector Gulfport, MS modified bitumen roof underlayment Wadsworth, OH SRS TopShield ICE & WATER ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS DEFENDER Gulfport, MS modified bitumen roof underlayment Wadsworth, OH.,-,...., r RESI5T0 let 4R4,"" A$TM D197�0 t3` Drum ond6ille;QC . MSSmodified self. a'dheriltg gl Ss, at retnfoiced, and; surfaced, SBS'!i brtutnen ;cry fulfport; " roof underlayment T Wa S'o 6o --- MODIFIED SOPRA-d ` ASTM D4601, Type II Gulfport, MS Fiberglass reinforced, SBS modified asphaltic base sheet Wadsworth, OH 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I413CER.A-111 Certificate'ofAuthorization #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 3 of 7 MEMO I etc. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 SOPREMA Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE I: ROOF COVER'OPTIONS f8C Seetionr TAS110(S10j, ,: PAS US TA5230(S23J,, . RAS 118,119 & 120 RA5133' TA5110(SII) .' RAS 130 ' Clay and -Concrete' Tiler-. . Underla ment -- y Asphalt Shingles Mechanical 1 Adhesive = Metaf . Slate'or Slate" Type Wood . Attach .Set, Shingles;, LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment See 5.6.1 LASTOBOND Shield, Pro HT-N, RESISTO SA SMOOTH PLY 40 Yes No No Yes Yes Yes LASTOBOND Shield HT, Pro HT-S Yes No No Yes Yes Yes EnviroShield Yes No No Yes Yes Yes LASTOBOND ECO, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, Yes No No No Yes Yes TopShield ICE & WATER DEFENDER, RESISTO LB1244 LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite Yes No No Yes Yes Yes Smooth Seal HT 5.6.1 Adhesive -set the is limited to use of the following underlayment / tile -adhesive combinations. TABLE 1A:ACLOWABLE,UNDERLAYMENT/TILE-AUHESIVE'COMBINATIONSl ' Underlayment `, , Adhesive .. - Florida ProductApp`rovaF LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment Dupont "Tile BondTM' Roof Tile Adhesive" FL22525 ICP Adhesives and Sealants "Polyset® AH-160" NOA 20-1124.07 I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval far Overturning Moment Resistance Performance. NEMO ETC, I.I.C. Evaluation Report 3m-SOPC-2I-FBCER.A-R1 Certljicote ofAuthorizotion #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 4 of 7 O.MEMO I etc. 5.7 Allowable Substrates: TABLE 2 `SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS . Substrates (designed to. meet wind loads for project) " 'Underlayment _ Application Type:,.:?rimer Matdrial(s) LASTOBOND Shield, LASTOBOND Pro HT-N, Deck ASTM D41 structural concrete RESISTO SA SMOOTH PLY 40, LASTOBOND Insulation (Optional) Elastocol Stick Zero Dens Deck Prime or SECUROCK Shield HT, LASTOBOND Pro HT-S, Gypsum -Fiber Roof Board EnviroShield, LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HTTU Underlayment, LASTOBOND ECO, RESISTO self- LB1236, TRI-BUILT Sand-R SA Shingle adhering Underlayment, Grip -Rite Eave & Valley Base Sheet (Optional) Elastocol Stick Zero ASTM D226, Type II felt Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, Existing sand -surfaced, glass -fiber RESISTO LB1236, TRI-BUILT Sand-R SA Shingle self- Existing RESISTO EXTERIOR PRIMER surfaced, mineral -surfaced or Underlayment, Grip -Rite Eave & Valley adhering substrate film -surfaced roof underlayment* Protector or TopShield ICE & WATER DEFENDER *Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 5.8 Attachment Limitations: Refer to Section 6 5.9 Exposure Limitations: 11ABLE3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Mawmum InstallationTyge Exposure(days),' LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Mechanically attached 30 Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT Mechanically attached 90 S/A Underlayment or Grip -Rite Smooth Seal HT LASTOBOND TU HT, SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment Mechanically attached or adhesive -set tile roof system 180 NEMO ETC, I.I.C. Certificote of Authorization H324SS 7TH EDITION (2020) FBC HVHZ EVALUATION SOPREMA Roof Underlayments Evaluation Report 3m-SOPC-2I-FBCER.A-R1 FL2569-R23 (HVHZ) Revision 1: 07/29/2021 Page 5 of 7 O.N EMO I etc. 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck the roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4, TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE:INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope : - Flat Max. 30-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Double -tile stacking method, as shown below 6:12 LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Lugged Underlayment Ow 6.1 SOPREMA Roof Underlayments shall be installed in accordance with SOPREMA published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 6.3.1 Approved Assemblies: Deck Type 1t.; " UVood;-Non=Insulated ` Deck Description: Min.19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. . Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND TU HT, SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and Table 4 for tile stagging limitations. NEMO ETC, I.I.C. Evaluation Report 3m-SOPC-2I-FBCER.A-R1 Certificate ofAuthorizotion #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL2S69-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 6 of 7 MEMO etc. 6.3.2 Deck Type 1:Wood, Noh-lnsulate,'d' ` Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch D.C. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT, self -adhering. Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood shakes or wood shingles. 6.3.3 Deck Type 1:`,. _ ."Wood; Non lnsulated� Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND ECO, RESISTO LB1236, TRI-BUILTSand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244, self -adhering. Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC—QUA9625; (414) 248-6409; Karen.buchmann@ul.com - END OF EVALUATION REPORT - NEMO ETC, I.I.C. Evaluation Report 3m-SOPC-2I-F6CER.A-R1 Certiyleote of Authorizotion #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 7 of 7