HomeMy WebLinkAboutREVISIONV.I.F. NO (1) #5 BAR VERT IN CONC. FILLED ",BE*AMAND AND EPDXY IN TO EXISTING BONEXIST. FOUNDATION W/CELL W 6" CONCRETE PA EW STARTER CELL. GROU (IF NOT SOLID) OR DRILL AND EPDXY #5 REBAR INTO EXISTING ' MU WALL, MIN. 12" EMBEDMEN (TYP) EXISTING 12"Dx18"W FOOTING FILLED CELLS WITH (1) #5 MAX. AT 4' O.C." WITH 2 #5 CONT. V.I.F. DOWEL INTO EXISTING CONCRETE LINTEL o I 0 24 O.C. SEE DETAILS /A4.0 V.I.F. MIN. 12" EMBEDMENT \ y � 1 POUR SOLID FOR NEW WINDOW SILL. NEW 12"Dx18"W FOOTING WITH (2) #5 CONT. V.I.F. T NEW STARTER CELL. GROUT (IF NOT SOLID) OR DRILL AND EPDXY #5 REBAR INTO EXISTING CMU WALL, MIN. 12" EMBEDMENT <� (TYP) 0 24" O.C. SEE DETAILS 4/A4.0 I I I I I ' • i 'I � 3 OPEN I I I STRUCTURAL PLA SCALE : 1 /4" = 1'-0" CONCRETE -- -- ----------� ---- ---- — t II II I I G.C. TO VERIFY EXISTING LIGHTS Y, I I irJ II II ELECTRICAL PLAt 2 SCALE : 1 /4" = 1'-0" INN gig EXISTING LINTEL OR BOND BEAM V.I.F. -ADD NEW FILLED CELL ON EITHER SIDE OF NEW OPENING. DOWEL INTO FOUNDATION AND BOND BEAM (1) #5 BAR VERT. IN CONC. FILLED CELL DOWEL AND EPDXY W 6" MIN EMBED INTO EXIST./NEW FOUNDATION AND BOND BEAM GROUT (IF NOT SOLID) OR DRILL AND EPDXY #5 REBAR INTO EXISTING CMU WALL, MIN. 6" EMBEDMENT (TYP) 0 24" O.C. PROVIDE MORTAR JOINT BETWEEN NEW AND EXISTING BLOCK (TYP.). NOTE: EPDXY SHALL BE HILTI HIT-HY200 OR EQUAL. ° n° a d. P' P NOTE: CONTRACTOR TO FIELD VERIFY ROUGH OPENING SIZES. I N G I NFILL DETAIL .0; SCALE 1" = 1'-0" DRILL AND EPDXY #5 REBAR INTO EXISTING SLAB, MIN. 6" EMBEDMENT (NEW)F 024" O.C. ON EACH SIDE OF TIN 16"Wx12"D FOOTING (2) #5 CONT 1'-6" 5 E FOOT G DETAIL SC LE : 1" = 1'-0" F1 FrTRIrAI KFY =@ DUPLEX OUTLET 45 SWITCHED DUPLEX OUTLET GFI =@ DUPLEX OUTLET ( Ground Fault Circuit Interrupter ) AR =@ DUPLEX OUTLET ( Arc Fault Circuit InterrupterP.B) -o' PUSH BUTTON SWITCH -( SWITCH -9 3 WAY SWITCH 4 4 WAY SWITCH LIGHT FIXTURE RECESSED LIGHT FIXTURE VP RECESSED LIGHT FIXTURE (VAPOR PROOF) CEILING FAN U �A TELEPHONE s TELEVISION m EXHAUST FAN (�p 220 VOLT OUTLET FLOOD LIGHT ( MOTION DETECTOR TYPE ) OS,D, SMOKE DETECTOR Oc.M.A. CARBON MONOXIDE ALARM (1) #5 BAR VERT. IN CONC. FILLED CELL W/ 10" HOOK 0 "U" BLOCK (SEE FOUNDATION PLAN FOR LOCATION) GROUT (IF NOT SOLID) OR DRILL AND EPO #5 REBAR INTO EXISTING CMU WALL, MIN. 7. EMBEDMENT (TYP) 0 24" O.C. PROVIDE MORTAR JOINT BETWEEN NEW AND EXISTIN BLOCK (TYP.). CONNECTION TO EXISTING CMU. SCALE : 1 /2" = 1'-0" GENERAL ELECTRICAL NOTES 1, ALL WORK SHALL BE DONE IN ACCORDANCE WITH BOTH LOCAL AND NATIONAL ELECTRICAL CODES, 2, ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL PLAN, RISER DIAGRAM, AND LOADS, AND NOTIFY THE GENERAL CONTRACTOR ❑F ANY ERRORS OR DESCREPANCIES PRIOR TO INSTALLATION. 3, ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO MAKE CERTAIN THAT ALL AIR-CONDITIONING POWER AND CONTROL WIRING AND CONDUITS ARE IN THE BID, 4, ELECTRICAL CONTRACTOR IS TO COORDINATE ALL SERVICE REQUIREMENTS WITH THE POWER COMPANY BEFORE BIDDING TO BE CERTAIN THAT ALL WORK NECESSARY TO MEET POWER COMPANY SPECIFICATIONS IS IN THE BID. 5. THE ELECTRICAL CONTRACTOR IS TO SIZE MOST BRANCH CIRCUITS) A MAXIMUM VOLTAGE DROP ❑F 3% IS PERMITTED, 6, SMOKE DETECTORS SHALL BE DIRECT WIRED 120V U.L. 217 APPROVED TYPE WITH AUDIBLE ALARM INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND LISTING. CARBON MONOXIDE DETECTOR(S) TO COMPLY W/ UL #2034-96, 7, ALL APPLIANCE / ELECTRICAL EQ ENT WILL BE PROTECTED AT NAME PLATE RATING AS PER NEC 110.3 & 110,21. 8, ALL ELECTRICAL CIRCUITS THAT SUPPLY THE FAMILY ROOM, DINING ROOM, LIVING ROOM, STUDY, HALLWAYS, BEDROOMS, CLOSETS, AND FOYER SHALL BE ARC -FAULT PROTECTED. 9, ALL 125 VOLT 15 & 20 AMP RECEPTACLES INSTALLED IN DWELLING UNITS SHALL BE TAMPER RESISTANT AS PER NEC 406.11. 10, INTERSYSTEM BONDING REQUIRED AND SHALL COMPLY WITH SECTION 250,94, NEC. 11. GARAGE DOOR OPENER TO BE GFI PROTECTED, 12. ALL EQUIPMENT INSTALLED ❑UTSIDE OR EXPOSED TO WEATHER SHALL BE NEMA TYPE 3R. 13. ALL CONDUCTORS ARE TO BE COPPER, TYPE THHN, UNLESS NOTED ❑THERWISE. 14, SWITCHES SHALL BE OF STANDARD GRADE OF SILENT TYPE. 15, RECEPTACLES SHALL BE 15A AND 120V OF THE GROUND TYPE. I& LIGHTING FIXTURES SHALL BE SELECTED BY THE OWNER. 507 OF THE LAMPS SHALL BE HIGH EFFICACY TYPE. 17. ALL DEVICES SHALL BE SMOOTH TYPE, IVORY COLOR, UNLESS OTHERWISE SPECIFIED. 18. ALL 120V 1-PHASE 15A AND 20A BATHROOM, AND EXTERIOR RECEPTACLES SHALL HAVE GROUND FAULT INTERRUPTER (GFI) PROTECTION WITH EXTERIOR RECEPTACLES OF THE WATERPROOF TYPE. ELECTRICAL CONTRACTOR MAY INSTALL INDIVIDUAL (GFI) IN LIEU OF (GFI) BREAKER WITH SEPARATE CIRCUIT. 19. ARC -FAULT CIRCUIT INTERRUPTER PROTECTION: ALL 120V, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED OR DEVICES IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUN ROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN THE NEC 210.12 (A)(1) THROUGH (6) 20. G.C. TO VERIFY ALL INSTALLATION HEIGHTS ABOVE FINISH FLOOR, 21. BRANCH CIRCUITS SHALL BE IN THIN WALL CONDUIT OR APPROVED ROMEX, 22. ALL FAN VENTING AND ROOF PENETRATIONS SHALL BE BY MECHANICAL CONTRACTOR. 23. EXHAUST FANS IN BATHROOMS (IF USED) SHALL BE RATED AT 1 CFM/SF OF VENTILATED FLOOR AREA. PREPARED FOR1 TH[IMAS DREIER 0 WHOLE HOUSE ENGINEERING 4451 ST. LUCIE BLVD, SUITE 201 FORT PIERCE, FL 34946 CONTACT: 772.409,1003 ENGINEERING(cWHENGINEERING.NET DRAWING NOTICE1 THESE DRAWINGS AND DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF WHOLE HOUSE ENGINEERING, LLC. AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE HOUSE ENGINEERING, LLC. WARNING: DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER WITH ANY QUESTIONS REGARDING DIMENSIONS. ARCHITECTURAL SYMBOLS CONTAINED WITHIN THESE DOCUMENTS ARE FOR GRAPHIC PURPOSES ONLY. SIZE AND LOCATION MAY VARY IN ORDER TO MEET THE MANUFACTURER'S 0 Ryan M REVISION DATE BY REV PERMIT COMMENTS 02/16/2022 JM B INITIAL SET 07/20/2021 JM A PROJECT NUMBER, NAME & ADDRESS: WHE10294 191 TUMBLIN KLING RD FORT PIERG4rFL 34982 vita" 0 7 ?_02j St. Lucie County Permitting SHEET TITLE: DETAILS SHEET NO.: A4.0