Loading...
HomeMy WebLinkAboutNOA 20-0813.08FILE COPY REVIEWED FOR REC,Es'����~V�� CO®E COMPLIANCE az c�3 — 0"2 MAR 14 2J22 M AM E T. LUCIE COUNTY BO c MIA 11-DADE COUNTY • 51. Lucie County, p2r1p1t9 ZUC CONTROL SECTION 3r v z 365 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA), wmv.miamidade.eov2Mffdine Lawson Industries, Inc. 8501 NW 90 Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction: RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "SH-7800 (Fin Frame)" Aluminum Single Hung Window. —L.M.I: APPROVAL DOCUMENT -..Drawing No. L7800-0801, titled "Series-7800 Single Hung Fin Frame Impact Window',% sheets I through:4 of 4, dated 03/31/08, with revision E dated 07/31/20, prepared by manufacturer, and signed and sealed by Thomas J. Sotos, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant .LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo; city, state, series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted;herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA willoccur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.18-0911.07 and consists of this page 1 and evidence pages E-1, E-2, E-3 and E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 20-0813.08 Expiration Date: November 06, 2023 Approval Date: October 08, 2020 T10102/20 Page 1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 08-0527.18) 2. Drawing No L7800-0801, titled "Series-7800 Single Hung Fin Frame Impact Window", sheets 1 through 4 of 4, dated 03/31/08, with revision D dated 11/01/17, prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E. (Submitted under NOA No.17-1212.18) B. TESTS 1. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung fin window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI 08-2083, dated 03114/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0527.18) 2. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung fin window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI 08-2084, dated 03/14/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0527.18) 3. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung fin window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI 08-2015, dated 01/15/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA Na 08-0527.18) 4. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung fin window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2016, dated 01/15/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0527.18) Manuel. Perez, P.E. Product xapdftr N Control E0 13.03 NOA No. 2 13.0 Expiration Date: November , Approval Date: October 08, 2020 E-1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBNHTTED UNDER PREVIOUS NOA's (CONTINUED) B. TESTS (CONTINUED) 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum single hung fin window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-07-4324, dated 01/15/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0527.18) 6. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung fin window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI 07-4325, dated 01/15/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0527.18) C. CALCULATIONS 1. Anchor verification calculations and' structural analysis, complying with FBC, dated 05/16/08 and 07/07/08, prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E. (Submitted under NOA No.12-0127.13) 2. Glazing complies with ASTM E1300-04/09 D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Ire. for their "Trosifol® Ultraelear, Clear and Color PVB Glass Interlayers°' dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. �+ Product Control EALM." (NOA No. 20 13. Expiration Date: November , Approval Date: October 08, 2020 E-2 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMTTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6tb Edition (2017) and of no financial interest, issued by manufacturer, dated January 22, 2018, signed and sealed by Thomas J_ Sotos, P.E. (Submitted under NOA No.17-1212.18) 2. Statement letter dated 01/22/18 of the editorial drawing changes issued by Lawson Industries, Inc., signed by Nelson Erazo, 'Senior Design Engineer. (Submitted under NOA No.17-1212.18) 3. Department of State Certification of LAWSON INDUSTRIES, INC. as a for profit corporation, active and organized under the laws of the State of Florida, dated 04/11/14 and filed at the Secretary of State. (Submitted under NOA No. 14- 0908.09) 4. Notification of 'Successor Engineer for manufacturer's NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to the NOA No. 08-0527.18, dated 02/27/09, signed and sealed by Thomas J. Sotos, P.-E. (Submitted under NOA No.12-0127.13) 5. Laboratory compliance letter for Test Reports No. HETI 08-2083, HETI-08-2084, HETI 08-2015, HETI 08-2016, BETI 07-4324 and HETI 07-4325, all issued by Hurricane Engineering & Testing, Inc., dated from 01/15/08 through 03/14/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0527.18) 6. Proposal No. 07-2527 issued by the Product Control, dated 03/29/07, signed by Manuel Perez, P.E. (Submitted under NOA No. 08-0527.18) G. OTHERS 1. Notice of Acceptance No.17-1212.18, issued to Lawson Industries, Inc. for their Series "SH-7800 (Fin Frame)" Aluminum Single Hung Window — L.MI., approved on 02/08/18 and expiring -on 11/06/18. Manuel Perez, P.E. Product Control Mr . NOA No. 20 13. Expiration Date: November 06, Approval Date: October 08, 2020 E-3 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMHT TED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No L7800-0801, titled "Series-7800 Single Hung Fin Frame Impact Window", sheets 1 through 4 of 4, dated 03/31/08, with revision E dated 07/31/20, prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E. B. TESTS 1. None C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Ine. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/08/24. 2. Notice of Acceptance No. 20-0622.01 issued to Eastman Chemical Company (MA) for their "Saflex PVB Clear and Color Glass Interlayers" dated 08/06/20, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC Th Edition (2020), dated August 03, 2020, issued by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. G. OTHERS 1. Notice of Acceptance No. 18-0911.07, issued to Lawson Industries, Inc. for their Series "SH-7800 (Fin Frame)" Aluminum Single Hung Window — L.M.I., approved on 10/11/18 and expiring on 11/06/23. Manuel Perez, P.E. Product Control Ex; r NOA No. 2013.0 Expiration Date: November 06, Approval Date: October 08, 2020 E-4 34375' WINDOW FIN FRAME WIDTH ot2 S1LS. ANCHORS II I]/16'1�.- 412 S.M.S. ANCHORS CA) 7 PER FRAME HEAD O.L. 1 (A) 4 PER FRAME HEAD fB> 4 PER FRAME SILL 1 L A� (B) 4 PER FRAME SILL fC) 6 PER FRAME JAMB 6' 6. (C) 6-PER FRAME JAMB J O a A ' Mox. D.L.O. Width to, a 48 11 16 / ao a a WINDOW FIN FRAME WIDTH WINDOW FIN FRA14E WIDTH 1��14J2S 14.123' Nit 4 PER AMC PERF.RH➢R9 114423' 23 A A' (A)) 4 PER FRAAXE SILL IFL- E (C) 6 PER FRAME JAMB r6' A D /� �/ 4,9 0 a lax. D.LO. Width e7a� ^� 14 zso w 48 11 16 B 14s00• .�1— w r // / J n /'/�,,`F'(y/I / •ern � 14.500' - i 1 � A 40123' 40123' 46123'^ 32.12Y VINDDV BUCK VI➢TH UN -EQUAL LITE RADIUS 32 WINDOW BUCKWIDTH UN -EQUAL LITE 32A2Y--- WINDOW BUCK WIDTH EQUAL LITE ELEVATION ELEVATION ELEVATION SERIES-7800 SINGLE HUNG IMPACT WINDOW — FIN FRAME General Notes: 1.) THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE (2017-6th Edition & 2020-7th Edition) INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ) AND ASTM 1300-98. THIS PRODUCT IS IMPACT RESISTANT, 2.) 2 X WOOD BUCKS SHALL BE INSTALLED AND ANCHORED SO THAT THE BUILDING RESISTS THE SUPERIMPOSED LOADS IN ACCORDANCE WITH REQUIREMENTS OF F.B.C. & TO BE REVIEWED BY BUILDING OFFICIAL. 3.) ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS, ANCHORS ON ALL WINDOW SIZES ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER (O.C.). 4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE TO BE ENGINEERED ON A SITE SPECIFIC BASIS, UNDER SEPARATE APPROVAL AND TO BE REVIEWED BY BUILDING OFFICIAL. 5.) WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS TYPES TABULATED HEREIN (SEE SHEET #3). 6.) WINDOWS ARE QUALIFIED FOR USE WITH DOUBLE GLAZE LAMINATED INSULATED GLASS TYPES TABULATED HEREIN (SEE SHEET y3). 7.) SEE SHEET 3 FOR LOCK DETAILS & OPTIONS. B.) SEE SHEET 3 FOR GLAZING DETAILS & OPTIONS AND DESIGN PRESSURES, 9.) WOOD OPENING SHALL BE PROTECTED WITH AN APPROVED MOISTURE RESISTANT WEATHERBARRIER (BY OTHERS), PRIOR TO WINDOW INSTALLATION. (SEE SHEET #1 FOR DETAIL) t0.) MATERIALS: INCLUDING BUT NOT LIMITED TO STEEL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF FLORIDA BUILDING CODE. it.) EXT. & INT. FALSE COLONIAL MONTINS ARE OPTIONAL & AND ARE APPLIED W/ SILICONE EXTERIOR OTHERS (TYPJ EXT. GRADE BACK BEDDING WINDOW INSTALLATION NOTES: TO BE APPLIED BEHIND 1. THE WINDOW OPENING MUST BE PROTECTED WITH A WINDOW FRAME FIN BY INSTALLER (TYPJ CODE APPROVED FELT OR MOISTURE/WEATHER BARRIER, APPROX 12WIDE THROUGHOUT ENTIRE PERIMETER OF THE WINDOW MOUNTING FIN. (NOT BY LAWSON INDUSTRIES) E. THE WINDOW FRAME FIN TO BE BACK -BEDDED W/ AN EXT. GRADE CAULK THROUGHOUT THE ENTIRE PERIMETER OF FIN BY WINDOW INSTALLER (TYP.) 3. THE EXPOSED EXT. PERIMETER OF THE WINDOW FRAME TO BE SEALED W/ AN APPROVED EXTERIOR GRADE CAULK BY OTHERS (TYP.) FRAME FIN EXT. GRADE PERIMETER CAULKING NOT BY 'LAWSON INDUSTRIES' TO BE APPLIED BY OTHERS (TYPJ WINDOW INSTALLATION DETAIL PRODUCT REVISED as eomplginoo with the Florida Building Co NOA-No. 20.0813.08 Ex iretlon Date 1/00/2023 Byn LLd Mlem ede ProduarCO rol - 100 b 10 M M 1 r t° Nato O C1 N O z d z Go2It. _j!w e�tetlt�r3(r°Ois (.I 0 O ; tW- It, S5�' 4~1 Gam:' Gn EXPOSED WINDOW FRANC FIN TO — BE PROTECTED WITH AN APPROVED MOISTURE / WEATHER BARRIER THROUGHOUT ENTIRE PERIMETER OF FIN BY OTHERS (TYP•) O HEAD � O ^fib n$ N EXTERIOR SILL EXTERIOR GRADE PERIMETER CAUL 012 SMS or WS W/ 1 1/2' MIN. WOOD EMBEDMENT (TYPJ ALL WOOD FRAMING ENGINEERED SEPARATE t. TO BE REVIEWED BLDG. OFFICIAL MR) �r L SHIM PACED Al (TYP.) RADIUS HEA NOTE LANCHORS TO BE #12 SMS OR WD• SCREW WITH A MINIMUM OF 1 1/2' PENETRATION INTO MEDMENT (TYPJ WOOD, ( REFER TO WINDOW ELEVATIONS ON e 1 FOR MAX. ALLOWABLE ANCHOR SPACING) n 00 wDD FRAMINGSHEET INEEREO SEPARATELY 0 BE REVIEWED WHIN THE CAP BEFWEEN THE WINDOW FRAME AND o C G OFFICIAL (iYPJ THE BUCK IS 1.FS3 THAN 1/8'. SHIMS ARE NOT REQUIRED. of of c E i t N M 12 SMS or WS W/ 1 1/2' MIN. WORD EMBED 2 BY 4 MIN. LAMINATED GLASS SEE ELEVATION FOR WOOD BUCK FASTENER SPACING r,P'� [ 4 \,/ C 18 LA NATED GLASS CLEAR SILICONE ADHESIVE 4 dl HN C I 1/4' SHIM GAP BEDDING COMPOUND SHIM SPACE 1i2• W E (TYP.).;.� 23 INTERIOR • :ti yr 20 .�'�•' Caa) ,�•: • ] G - - - H RFTERIOR (e[o•) 11 12 12 GLAZING SEALANT x�: 7m; <MM ,_ _— + EXPOSED WINDOW FRAME FIN TO� O BE PROTECTED WITH AN APPROVED MOISTURE / WEATHER HARRIER JAMB TKR13UGHDO ENTIRE PERIMETER OF FIN BY OTHERS (T' (TYP•) 2 BY 4 MIN. WOOD BUCK ��j — N 12 SMS or WS W/ 11/2• NIN. WOOD EMBED SEE ELEVATION FOR GRADE CAULKING WINDOW FRAMEBUCK (MAX) 54 3/8' WINDOW FRAME FIN (MAX.) 11/B• ■ s • s o m JAMB PRODUCT REVISED mD comp naa with the Floridc BulWlnp odc NOA-No. 20.0813.08 Fx IMlon Date( 1/08 2023 BIn Mlam ada ProduaYCo rol .r° •Fie rE� 'rg �+v ':•G) .: ^�• ;UI to i; -: 7800 FIN IMPACT SINGLE HUNG WINDOW - EQUAL LITE j WINDOW Glass Glass Glass Glass GIs ss DIMENSIONS Type "I" Type "2" Type "3" Type "4" Type sv 1 13 1 18.125 1 37.375 1 60 1 60 1 46 1 46 1 60 1 18.125 I H32 1 25.5 1 25 1 60 1 60 1 46 1 46 1 60 1 7800 FIN IMPACT SINGLE HUNG - VIEW WINDOW WINDOW Glass Glass Glass Glass Glass MENSION9 Type "1" Type "2 Type "3" Typo "4" Type "S" 60 1 60 1 46 1 46 1 60 1 ILH35 - 4 25.5 1 62 1 60 60 60 1 60 1 48 1 46 1 60 1 H36 - 4 1 25.5 1 73.25 1 60 1 60 1 23 1 36 1 37.375 1 60 1 60 1 46 1 46 1 60 11 24 - 2 1 36 1 49.625 1 60 1 60 1 46 1 46 1 60 1 59-5 35 5/.125 I 6U 6U 1 46 415 1 6U cv— I ov vc I vv I vv 'w n 5 36 62 60 60 46 46 60 25-4 36 62 60 60 46 36 73.25 60 60 46 46 60 26 - 4 36 73.25 60 60 46 52 52.125 25 60 60 46 46 60 26 - 45 36 73.25 60 60 46 33 52.125 37.375 60 60 46 46 60 26 - 5 36 73.25 60 60 46 54 52.125 49.625 60 60 46 46 60 34-2 52.125 49.625 60 60 46 3 -5 52.125 57.125 60 60 46 46 60 34-3 52.125 49.625 60 60 46 5 1 52.125 1 62 1 60 60 46 46 60 35 - 3 1 52.125 1 62 60 60 46 46 1 52.125 1 73.25 1 60 60 46 46 60 35 - 4 52.125 1 62 60 60 46 36-4 52.125 73.25 60 60 46 N®te: (a) WINDOWS WITH GLASS TYPES '4 & 5' INSTALLED ABOVE 36-45 52.125 7325 60 1 60 1 46 30FT.IN THE HVHZ, THE I.G. EXTERIOR LITE SHALL BE TEMPERED. 36-5 52.125 73.25 80 60 46 8 kNGDwTH G4(x) 0,125' ANN. B HS, GLASS (OUTBOARD) G2 G3 (NOT QUALIFIED FOR SMALL MISSILE IMPACT) (xx) 0.125' TEMPERED GLASS (OUTBOARD) '(QUALIFIED FOR SMALL MISSILE IMPACT) G5GLA21HG nEPTH 23 I— LAMINATED GLASS CO POSITION -Type 1 h Type 2 INSULATED LAMINATED GLASS COMPOSITION Tne 4 Tax CLL99 DISCRIMON DRTAD. LAIDN=Z DIISCRIMON nu CLUB DRSCR MON DnM' IAWATR DDSCRMON 1 1/8' NEAT-STRENGHTENED GLASS = e -- t- TROSIFOL PVB 1 1/6' ANNEALED GLASS 00. CCU 0090' PLASTIC INTERLAYER1Q =- or E 0➢90' PLASTIC DNERLAYER �° SAFLEX PVB br 1/e' NEAT-STRENGHTENE➢ GLASS 1 67�a 8- SAFLEX PVD 3 1/B• ANNEALED GLASS = _ E..ti Ch06.41 Ca 4 1/4' INSULATED AIR SPACE 5 1/8' ANNEALED GLASS I o0�v INSULATED LAMINATED GLASS COMPOSITION e 6 CTPAI GLASS DDSCRIPTICN DRTAM LAUMMMTS DSSCRDMCN t 1/8• HEAT-STRENGHTENE➢ GLASS z M' PLASTIC INTERLAYER 3 1/8• HEAT-S7RENGHTENE➢ GLASS TROSIFDL PVB by, Laminate Twe9 & Gpti0II9 4 1/4' INSULATED AIR SPACE KurAruy AAtrke Inc 1) Trosiiol PVB by: Kuraray America Inc. S ve• NEAT-STRENGNTEHEO GLASS l 2) Satlex PVB by: Eastman Chemical Company GLAZING DETAILS, OPTIONS AND DESCRIPTION f' LAMINATED GLASS COMPOSITION - e 3 O1A99 DSBCBIP170N DBTAa. WIINATE DESCIDPnON = _ _ _ - ::. SAFLC% PVB br we' eoaMan cho z�o1 co. t vs• AHNEnLto GLAss 0,090' PLASTIC INTERLAYER Ire• ANNEALED eLAss 60 ji h 26 t M 00 � M 10 G I 5 mom 6 s25 21 LOCK (LATCH AND WEEP) OPTIONS I. BOTH EXTRUDED ALUMINUM AND PLASTIC LIFT ® I HANDLE LOCHS ARE QUALIFIED FOR USE ON ALL WINDOWS. W I 2. BOTH DIN CAST AND NYLON CAM LOCLC9 ARE � � QUALIFIED FOR USE ON ALL WINDOWS. a I 3. ONLY TWO (2) LOCKS ARE REQUIRED PER EACH 1 VENT. � Q PRODUCT REVISED its CompWin with the Florida Building adi NOA-No. 20.0819.08 Ex Iratlon oats !08 20 3 B Mlam ads Praduaf'Co rol 1v 1 I I Ia 1 -' j •N N 0 �0 - �� OFRAME HEAD L-7801 FRAME SILL FIXED MEETING RAIL L-7704 FRAME JAMB L-7803 O LJ -' I FRAME TOP CORNER / I I 1 — .— -I �!/ w VENT INTERLOCK RAIL VENT BOTTOM RAIL VENT JAMB RAIL .O .. cILL L-7705 L-7706 L-7707 O O O FRAME BOTTOM CORNER t11374--,VENT TOP CORNER �gE2 VENT SPRING LATCH GLAZING BEAD GLAZING BEADGLAZING HEAD L-7639 L-7708 L-7711 L-4204 O17 —II— 050 A50 I ASO T O VENT aniro 1.013 —.391 �- L� _vgjJT BOTTOM CORNER •1 .115J .698 773! T73— j *.411 I FRAME & SASH CORNER DETAILS BILL OF MATERIALS ITEM PART y REQD. DESCRIPTION REMARKS I L-7801 I 1 FIN FRAME HEAD 6063-T6 ALUMINUM 2 L-7802 1 FIN FRAME SILL 6063-T6 ALUMINUM 3 L-7803 2 FIN FRAME JAMB 6063-T6 ALUMINUM 4 L-7704 1 FRAME FIXED MEETING RAIL 6063-T6 ALUMINUM 5 L-7705 I VENT MEETING (TOP) RAIL 6063-T6 ALUMINUM 6 L-7706 1 VENT BOTTOM (LATCH) RAIL 6063-T6 ALUMINUM 7 L-7707 2 VENT JAMB (SIDE) RAIL 6063-T6 ALUMINUM 8 1 L-7708 JAS REQ'D. GLAZING BEAD ( 3/8' ) 6063-T5 ALUMINUM 9 FS-006 JAS REQ'D. FRAME ASSEMBLY SCREWS H8 X 3/4' P.H. PHILLIPS 10 FS-040 AS READ, INSTALLATION SCREWS 012 X 1 1/4' F,H./PHIL. 11 L-7531 AS REQ'D. BULB VINYL WTS'P 1/4' DIA, BULB #3033 12 PWS-003 AS REQ'D, FIN SEAL WEATHERSTRIP 187'x,230- 13 PWS-005 AS REQ'D, FIN SEAL WEATHERSTRIP .187'x,350' 14 PWS-009 AS REQ'D. FIN SEAL WEATHERSTRIP ,187'x,310' 15 HC-024-1 2 SELF ADHESIVE PILE PAD 1/4' X 1 1/2' 16 L-7711 JAS REQ'D. GLAZING BEAD 6063-T5 ALUMINUM 17 L-4204 AS REQ'D, GLAZING BEAD 6063-T5 ALUMINUM 18 L-7723 1 SASH BALANCE CAM/GUIDE 42 X VENT) 19 L-7725 2 RIGID VINYL SASH STOP (2 X FRAME) 20 L-7727 2 BLOCK 8 TACKLE BALANCE BSI Balance Systems 21 L-7539 2 VENT EXTRUDED LATCH (2 X VENT) 22 L-7523 2 VENT LATCH SPRING (I x LATCH) 23 ISM-5731 AS REQ'D. GLAZING SILICONE SM-5731 24 w 2 Laminated Glass SEE GLAZING DETAILS 25 HC-057-1 2 VENT MOLDED LATCH MOLDED NYLON 26 HC-558-1 2 VENT SWEEP LATCH MOLDED NYLON 27 ■ 2 FRAME SILL FOAM GASKET SELF ADHESIVE 28 HC-026-1 1 SCREEN FRAME 6 MESH 29 L-7730 1 IPRODUCT LABEL 30 rt 2 1 Assembly Joint Gasket AT FRAME SILL 31 SM-5504 AS REQ'D, JOINT SEALANT SM-5504 32 ■ AS REQ'D, PERIMETER ACRYLIC CAULK OSI POLYSEAMSEAL PRODUCT REVISED as comp In0 wNh the Florid Building odi ivoa-Na. 2o•oe�3.oe Bx Intlon Dsto 1/06/2023 Byl Mirm radr. ProduoxCo roi