Loading...
HomeMy WebLinkAboutPermit WorksheetPERMIT NUMBER Installer, �'Q. k. License i — Address of home �� t being installed Manufacturer Length x width x NOTE: If home is a single wide fill out one half of tho blocking plan if home Is a triple or quad wide sketch in remainder of home I understand Lateral Arm Systems cannot be used on anylhome (new or ed) where the sidewall ties exceed 5 1t4 in. Installer's initials Typical pier spacing 2' 1 lateral -: iERMIT WORKSHEET ptigc 1 0.' 21 r New Home ❑ Used Home Home installed to the Manufacturees Installation Manual Home is installed in accordance with Rule 15-0 Single wide [] Wind Zone II (] Wind Zone III L Double wide PCInstallation Decal # n Triple/Quad 0 Serial # G �1 ff � ����I A�,Q PIER SPACING TABLE FOR I ICFn WnRAC:0 Load Footer bearing size 16' x 16' 18 1/2' x 18 1/2- 20- x 20' 22' x 22' 24' X 24' 26' x 26- capacity (sq in) (256) (342) - (400) (484)' (576)' (676) 1000 s 3 4 5 8' 1500 s 4 6 6 7 8 2000 s 6 2500 sf 7 6 3000 st 8 g 8 8 8 3500 psi 1 8 g g 8 ' intp-mrant"I f- Q.J. Irr,_a .. PIER PAD SIZES I-beam pier pad size j(1Y2_ Y'2Z4( 2 Perimeter pier pad size Other pier pad sizes (required by the mfg. ) Draw the approximate locations of marriage wall openings 4 foot or greater. Use this ` symbol to show the piers. POPULAR PAD SIZES I - • Ir;Y7L1 6 Ifififif+�.rtryz��MK Uilm filCL�iL�.1i[:�ta. A i�ilf►�!i►�.�IP�wa, 10- List all marriage wall openings greater than 4 foot MWJAM and their pier pad sizes below. - Opening Pier pad size ANCHORS y"�'i1� 4ft L�5fl w ous �% i/� Y Z7 Y� FRAME TIES Im Aft, Aft Mh within 2' of end of home spaced at 5' 4" oc CO NT OTHER TIES Longitudinal S ap!llzg Device S Number Manufacturer Siciewall Longitudinal Stabillzinnal � Device w/ L `rail Arms MarriageLongituds wall Manufacturer Shearwall J 'PERMIT NUMBER POCKET PENETROMETER TEST The pocket penetrometer tests are rounded wn to psf or check hereto declare 1000 lb. soil without testing. X X X POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the tooter. 3, Using 50015. increments, take the lowest reading and round down to that increment. X X X TORQUE PROBE T The results of the torque probe test is Inch pounds or check here if you are declaring 5' anchors without testing . A test showing 275 inch pounds or less will require 5 foot anchors. Note: A state approved lateral arm system is being used and 4 It, .anchors are allowed at -the sidewall locations. I understand 5 ft anchors are required at all centerline(tie points where the torque test reading is 275 or less and where the Mobile home manufacturer may requires anchors with 400 apacity. installer's initials ALL TESTS MUST BE PERT RMED BY A LICENSED iNSTALLER Installer Name \J_Iba 1 ICE t"xA Date Tested CQ— 1 "t D Electrical :bnnect electrical conductors betilsen multi -wide units, but not to the ma' po - ource. Thls-inoludes the bonding wire between must -wide units. Pg. onnect all sewer drains to an existing sewer tap or septic to k�~ onnect all potable water supply piping to an axis ' ater meter, water tap, or other tdependent water supply systems. Pg. PERMIT WORKSHEET Site Preparation Debris and organic material removed _ Water drainage: Natural Swale page 2 of 2.' I Other Floor. Type Fastener. Lengtf It Spacing: � (lt�t� ) Walls: Type Fastener. Length. 'I Spacing: Roof: Type Fastener, Length: '� Spacing: i For used homes a mi . 30 gauge, 8" wide, galvanized meta strip will be centered over the peak of the roof and fastened with gals. roofing nails at 2" on center on both sides of the centerlinb. Gasket (wmtherprooting requirement) 1 understand a properly installed gasket Is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. Installer's initials. Type gasket vimm Installed: Pg. �t, _ Between Floors Yes YJ triiLj„p�/ Between Walls Yes _ Bottom of ridgebeam Yes er roonn he b rd wil ePo Ynottco r taped, Yes P_ . nit ' s tnurer's specifications. Yes re him Ins ed allow intrusion of rain water, Yes Skirting to be installed. Yes t/r'No Dryer vent installed outside of skirting. Yes ✓WA Range downflow vent installed'outside.of skirting. Yes - WA Drain lines supported at 4 foot intervals. Y Electrical crossovers protected. Yes+ Other: Installer verifies all information given with this permit worksheet is accurate and true based on the Installer Signature ! �f'�L� Date�� D_