Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - ROOFING TILESBCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Fac M- O ) r `, ° Product Approval USER: Public User Links I Search I �_ .-'- < = REVIEWEDFOR Product Approval Menu > Product or Application Search > Bopllcation List > Application Detail CODE COMPLIANCE FL # Application Type FL Revvisionision 13 ST. LUCIE COUNTY BOCC Code Version 9/L Application Status Approved �� Z *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Z Z� `�. Q� S3 �✓ Comments Archived FILE COPY Product Manufacturer Boral Roofing Address/Phone/Email 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 (801)380-6091 RobinAnderson@boral.com Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Evaluation Entity Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Anderson Robin RobinAnderson@boral.com Robin Anderson 10701 So. River Front Parkway Suite 300 So. Jordan, UT 84095 (801) 380-6091 robinanderson@boral.com Robin Anderson 7575 Irvine Center Dr. #100 Irvine, CA 92618 (801)380-6091 robinanderson@boral.com Roofing Roofing Tiles Evaluation Report from a Product Evaluation Entity IAPMO Uniform Evaluation Services LLC. QAI Laboratories 12/31/2025 Gary W. Walker P Validation Checklist - Hardcopy Received Standard Year ASTM C1492' 2009 ASTM E108 2016 Product Approval Method Method 1 Option C Date Submitted 11/09/2020 Date Validated 11/10/2020 Date Pending FBC Approval Date Approved 11/18/2020 rummary of Products' 6o,to PagePage'I / 2'� - FL #" - Model; Number.or Name' Description 7849.1 Barcelona - Impact High Profile - Katy, TX Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion.p-df Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pd Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pd 7849 2 : - ` " :Barcelona 900 High Profile=- Lake•Wales, FL ': •••: Limits of Use.. Installation Instructions Approded for use in HVHZ No Approved"for use outside HVHZ': Yes FL7849 R13II EBS-Installtion.pd L7 F849` R13 II Florida High Wind Tile:InAallation Manual - " st Impact Resiant: N%A Design Pressure: N/A 'Other: 6th Edition.R. . Verified By: Gary:W. Walker-40455 Created by Independent Third 'Party Yes Evaluation Reports FL7849 R13 AE UES ER-4.7,pdf 7849.3 Barcelona 900 High Profile - Lathrop, CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion.1df Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pd Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AF UES ER-412.pd 7849 4 Bermuda `_ Flat ,Profile _ Okeechobee, FL'.� . Limits of Use =Approved) for use.in HVHZ No - Approved for. use outsiderHVHZ :Yes -Instal labon,Instructions FL7849 R13AT -EBS-Installation FL7849 R13 II 'florida H:oh'Wind Tile' Installation Manual - 'Impact Resistant: N/A - 6Eh Edition: Design pressure.`N/A Verified By: IAPMO Uniform"Evaluation Service's'LLC. ;Other ° ._. •• Created by Independent Third Party . Evaluation Reports FL7849 R13 AE UES ER 412:.... 7849.5 Cedarlite 600 Flat Profile - Stockton, CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II Cedarlite Madera-Installation.pd Approved for use outside HVHZ: Yes FL7849 R13 II EBS-Installtion.pdf Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Design Pressure: N/A Other: Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports. FL7849 R13 AE UES ER-412.pd -7849 6 ' . Espana /Barcelona -`'High :Profile -Rialto, GA' L mits'of. Use Approeved for use,in HVHZ No Approved for use'outside'HVHZ :Yes Impact Resistant: N/A Design pressure:, N/A Installation. Instructions FL7849 R13"II EBS-Insralltion.p447- FL7849 R13 II Florida High Wind Tile Installatlon Manual 6th Edition: Verified By: Gary W : Walker 40455 Other `: Createdby Independent Third•Party Yes -,. - :: Evaluation`Reports:- "= FL7849 013 AE UES ER-412.pdf 7849.7 Espana / Barcelona High Profile - Henderson, NV Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion.pdf Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pd Impact Resistant: N/A Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.p-df 7849 8: ,Espana 600 / Bar�celona;60& . :. High Profile- Rialto; CA Limits of Use Installation Instructions Approved for use in HVHZ No FL7849 R13 II EBS-Installtion. Approved' for use outside HVHZ. Yes Impact Resistant: N/A ,: ', ;. ,FL7849 R13 - II- Florida High Wind Tile Installation' Manuat - .6th.Edition.pdf' Design Pressure: N/A Verified By: Gary W.% Walker. 40455 :Other • .. ` Created;by.:Independent Third Party::Yes Evaluation Reports. FL7849: R13� AE` UES ER-412.pd� ' 7849.9 Estate "S" Low Profile - Okeechobee, FL Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 iR 3 Ij EBS-Installation.: Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.: Impact Resistant: N/A Design Pressure: N/A Verified By: ICC Evaluation Service, LLC Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.pdt 7849.,10, Galena Spanish S";"' , " High Profile - Okeechobee FL ; Limits of Use Installation Instructions `Approved.for use in HVHZ No _'` FL7849 R13 II" EBS'-Installation.: Approved for use outside;HVHZ:.;Yes FL7849 R13' II Florida High Wind Tile Installafion Manual - 6th Edition.` Impact Resistan' r N/A Design Pressure: N/A :." ,Verified By:-.IAPMO Uniforrrm,EValuation;$ervices LLC.' :.. Other: Created, by Independent Third, Party: Evaluation Reports FL7849 R13 AE UES ER=412.pdf,.. 7849.11 Madera - 700 & 900 Flat Profile - Stockton, CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II Cedarlite Madera -Installation.: " Approved for use outside HVHZ: Yes FL7849 R13 II EBS-Installtion.pd Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition. Design Pressure: N/A Other: Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pd 7849 12 Mission /' Barcelona = High Profile --Phoenix, AZ Limits of Use Approved for. Use m HVH2 ,No Installation Instructions FL7849 "R13- II EBS-Installtion.p Approved for use outside. HVHZ: Yes FL7849 R13 ' II Florida High Wind Tile Installation. Manual - -6th Edit'on.pd " Impact Resistant: N/A Design Pressure:'•N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports. -FL7849 R13 AE UES ER-417: 7849.13 Plantation Flat Profile - Okeechobee, FL Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installation.pdf Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Impact Resistant: N/A Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.pdf 7849 W-' . Saxony, -Country -Shake, Country.' .. "-Flat-Prof le.- Katy, TX, Slate :Count S Iif Shake;, English ; rY_ . p . Thatch, Impact;_-Shake•&Sate Instaliation Instructions . FL7849 R13 iI EBS=Installtion.(�df" FL7849 RQ 11 Florida High Wind Tile_Install 'tlon Manual - 5th :Edition.pc�f Verified By:. ICC Evaluation Service, LLC treated by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.odf 7849.15 Saxony - Shake & Slate Flat Profile - Phoenix, AZ Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installation.pdf Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind The Installation Manual - Impact Resistant: N/A 6th Edition.pd Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.pd 7849.16. -Saxony-',;Shakes Slate; ;Country ,,; Flat Profile:- Denver, CO Slate Split, Old Eriglishjhatch &:,:. ` Impactw. ; Limits: of Use`. Installation. Instructions.`,-: Approved for use in HVHZ. No FL7849 R13. II EBS-Installtion.pdf 'Approved for use outside HVHZ:=Yes FL78-49 Rn II' Florida Hlgh Wind Tile Installation Manual Impact Resistant: N/A- ., ;. 6th Edition.pdf- - _Design Pressures N/A ' Verified'Byr Gay W' Walker 40455 ;Other. Created -by Independent Third.. Party. -Yes Evaluation Reports FL7849 R13 -AE UES ER-412.p�d 7849.17 Saxony 600 - Slate, Shake & Split Shake Flat Profile - Stockton, CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion.odf Approved for use outside HVHZ: Yes FL7849 R13 II Florida Hlah Wind Tile Installation Manual - 6th Edition. Impact Resistant: N/A Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pdf 7849.18 Saxony 600 Slate, Shake.& Split' -Fiat Profile - Rialto' CA, Shake Limits of .Use Installation Instructions Approved for -use in HVHZ No FL7849 R13-II EBS-Installtion:pdf Approved for -use outside HVHZ:: Yes FL7849 R13 II Florida High .Wind Tile Installation Manual- Impact Resistant: NIA ` , 6th Edition.p?d Design Pressure:,N/A, Verified By: Gary.-W. Walker 40455 "Other: = _ Created by Independent Third. Party.: Yes Evaluation Reports FL7849 R13 AE UES ER 412.p 7849.19 Saxony 700 - Shake, Slate & Split Flat Profile - Stockton, CA Shake Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion.pd Approved for use outside HVHZ: Yes FL7849 R13 11 Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edltion.pd Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.p& J849.2.0 Saxony 700 Shake, Slate &-Split• , Flat Profile. - Rialto, CA' Shake., Limits of Use "' Installation Instructions Approvedlor use in HVHZ: •No FL7849= R13 II .EBS-Installtion.12d Approved for use outside HVHZYes FL7849 R13 II Florida High Wind Tile Installation Manual Impact Resistant: N/A -6th Ed4tion.pd Design Presswe' :, N/A Verified By: Gary W:',Walker. 40455 Other Created by.IndependentThird.Party• Yes Evaluatn FL7849,R13RAE-U S'ER 412.: Go to Page + �1 Page 1 / 2,' Back Next' Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ® ® Mg Credit• Safe SeClAr1ty m i-.7I CS' MIMI®D�►DE � MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE (NOA Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 T (786) 315-2590 F (786) 315-2599 www.m iamidade.imWeconomy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product. or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it. shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 21-0107.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 21-0420.06 Expiration Date: 04/26/22 Approval Date: 08/26/21 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This renews a system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Barcelona 900 Length =.17" TAS 112 High profile; interlocking, one-piece, 'S' shaped, Width = 13" Type — la high-pressure extruded concrete roof tile '/2" thick equipped with three nail holes. For direct deck or battened nail -on, mechanically fastened, mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete Width: varies roof pieces for use at hips, rakes, ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BOND Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Touch `N Seal StormBond®2 Two- Two component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive Touch `N Seal StormBond® One One component polyurethane Component Polyurethane Roof Tile foam'adhesive. Adhesive 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. DuPont de Nemours; Inc. DAP Foam, Inc. DAP Foam, Inc. NOA No.: 21-0420.06 Expiration Date: 04/26/22 Approval Date: 08/26/21 Page 2 of 7 i 2.3 SUBMITTED EVIDENCE: Test Agency Redland Technologies Professional Service Industries, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering, Inc. American Test Lab of South Florida PRI Construction Materials Technologies NEMO ETC, LLC Test Identifier 7161-03 Appendix III 7161-03 Appendix II P0402 Letter Dated Aug. 1, 1994 P0631-01 IC-1320-94 Test Name/Renort Static Uplift Testing TAS 102 & TAS 102(A) Wind Tunnel Testing TAS 108(Nail-On) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Physical Properties TAS 112 25-7688-3 TAS 101 (Adhesive Set) 25-7688-10 TAS 101- (Mortar Set) 25-7688-5 Static Uplift Testing TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) 25-7688-4 Static Uplift Testing TAS 102 (4" Headlap, Nails, Clips) 520111-3 Static Uplift Testing 520191-2-1 TAS 101 Calculations Evaluation Calculations RT0617.03-16 COPO-002-02-10 COPO-002-02-02 COPO-002-02-01 2002T0003.01 4c-DPB S-20-LSOTM-01.C.R1 Aerodynamic Multiplier Restoring Moments Due to Gravity TAS 112 TAS 101 TAS 101 TAS 101 TAS 101 TAS 101 Date Dec. 1991 Dec. 1991 Sept. 1993 Aug. 1994 July 1994 Feb. 1995 June 1996 July 1996 June 1996 June 1996 Dec. 1998 March 1999 09/01/16 09/01/16 06/29/16 10/12/2016 10/12/2016 10/12/2016 11/06/20 12/17/20 NOA No.: 21-0420.06 Expiration Date: 04/26/22 Approval Date: 08/26/21 Page 3 of 7 3. LDMTATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may require, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Department of Regulatory and Economic Development — Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 Minimum slope 4/12 for mechanically attached tiles. 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight-W (Ibf) Length-1 (ft.) Width-w (ft.) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Application Barcelona 900 0.286 0.301 Table 3: Restoring Moments due to Gravity - M9 (ft.-Ibf) Tile Profile 2":12" 3":12" 4":12" 6":12" 6":12" 7":12" or greater Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck N/A 7.07 1 N/A 7.00 1 6.19 6.90 6.06 6.76 1 5.92 6.60 5.76 6.42 NOA No.: 21-0420.06 MIAMI•DAD: COUNTY Expiration Date: 04/26/22 Approval Date: 08/26/21 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mr (ft.-Ibf) for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck (min 16/32" plywood) Direct Deck (min. 19/32" plywood) Battens Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail Field Clip) 23.1 23.1 19.0 1-10d Smooth or Screw Shank Nail Eave Clip) 29.3 29.3 24.0 2-10d Smooth or Screw Shank Nails Field Clip) 27.6 27.6 38.6 2-10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 41.8 2-10d Ring Shank Nails' 33.1 48.1 45.2 1. Installation with a 4" the headlap and fasteners are located a min. of 2%" from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mr (ft-Ibf) for Two Paddy Adhesive2 Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 TILE BONDTm Roof Tile Adhesive 193 TILE BONDTm Roof Tile Adhesive 29.34 ICP Adhesives Pol set® AH-160 29.35 Touch'N Seal StormBond®2 666 Touch 'N Seal StormBond® 487 2 3 4 5 6 7 See foam adhesive manufacturer's component approval for installation requirements. Medium paddy weight of 8 grams per paddy of TILE BONDTm Roof Tile Adhesive Medium paddy weight of 10.7 grams per paddy of TILE BONDTm Roof Tile Adhesive Medium paddy weight of 8 grams per paddy of Polyset® AH-160 Medium paddy weight of 8 grams per paddy of Touch 'N Seal StormBond ® 2 Medium paddy weight of 8 grams between tile and underlayment, paddy weight of 4 grams on overlap of tile of Touch 'N Seal StormBond ® one component) NOA No.: 21-0420.06 CMLAMI�-DADE COUNTY Expiration Date: 04/26/22 Approval Date: 08/26/21 Page 5 of 7 IV Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 ICP Adhesives Pol set® AH-160 66.51 ICP Adhesives Pol set® AH-160 38.79 Touch'N Seal StormBond®2 8210 Touch'N Seal StormBond02 6311 TILE BONDT"' Roof Tile Adhesive 5812 8 Large paddy weight of 63 grams of Polyset® AH-160 9 Medium paddy weight of 24 grams of Polyset® AH-160 10 Large paddy weight of 60 grams of Touch 'N Seal StormBond ® 2 11 Medium paddy weight of 30 grams of Touch 'N Seal StormBond ® 2 12 Two paddys combined to form one. Place one 10 gram paddy on the center of the underside of the tile, place a second paddy of 20 grams on the deck. When tile is placed the two paddys combine to create one paddy weight of 30 grams total of TILE BONDTm Roof Tile Adhesive. Table 7: Attachment Resistance Expressed as a Moment - Mr (ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Barcelona 900 Mortar Set10 24.5 13 Seespecific mortar manufacturers Notice of Acceptance 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". No LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 21-0420.06 MIAMI•DAD, COUNTY Expiration Date: 04/26/22 Approval Date: 08/26/21 Page 6 of 7 a PROFILE DRAWING BARCELONA 900 CONCRETEROOF TILE END OF THIS ACCEPTANCE i/8 " NOA No.: 21-0420.06 Expiration Date: 04/26/22 Approval Date: 08/26/21 Page 7 of 7