Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS;1/19/2021 u Florida Building Code Online BCIS Home Login I User Registration Hot Topics Submit Surcharge Stats & Facts Publications I Contact Us BCIS Site Map Links Search I Florida 1r a L s 1ld Product Approval USER: Public User Product Approval Menu > Product or Aonllcatinn Search > ARPlication List > Application Detall FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL5259=R31 Revision 2020 Approved POLYGLASS USA 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 Ext 242 malpert@polyglass.com Maury Alpert malpert@polyglass.com RECEIVED JAN 2 4 2022 St. Lucie County Permitting REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC .3191 zz 2y cJ1 —vS3� TECH REP 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866)802-8017 uspolyglasstechnlcal@polyglass.com QA REP till West Newport Center Drive Deerfield Beach, FL 33442 (888) 410-1375 uspolyglasstechnical@polyglass.com Roofing Underlayments FILE COPY Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2022 Validated By John W. Knezevich, PE ?: Validation Checklist - Hardcopy Received Certificate of Independence FL5259 R31 COI 2020 01 COI NIEMINEN.pdf Referenced Standard and Year (of Standard) standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 https://floridabuilding.org/pr/pr app dtl.aspx7paratn=wGEVXQWtDgvbSgAaZp3Crk2v8`/*2fegOlip3cPzPSPEkchxoaj6Vjgl°/a2bg°/p3d%3d 1/2 1 /19/2021 ' ' Florida Building Code Online FM 4474 2011 FRSA/TRI,"Sixth Edition 2018 UL1897 2015 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method. Method 1 Option D Date Submitted 10/22/2020 Date Validated 10/26/2020 Date Pending FBC Approval 11/01/2620 Date Approved 12/15/2020 Date Revised 12/21/2020 , Summary of Products FL # Model, Number or Description Name 5� 259._1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-622.5 Installation Instructions FL5259 01 II 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- 1131.pdf Verified By: Robert Nleminen PE-59166 Created by Independent Third Party: Yes other: 1.) The design pressure in this application relates to one particular underlayment system for use in tile roof systems. Refer to ER Section S.B.3 for other Evaluation Reports FL5259 R31 AE 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R31.pdf. Created by Independent Third Party: Yes systems and associated maximum design pressures. 2.) Refer to PR Section 5 for other limits of use. 8ac!: 'Next contact Us :: 2601 Blair Stone Road, Tallahassee FL 32390 Phone: $50-487-1824 The State of Florida is an AA/EEd employer.Copyright 2007-2013 State of Florida.:: Privacy staternent :: Accessiblllty Statement r: Reiund Statement Under Florida iaw, email addresses are public records. If you do not want .your .e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions„please contact 850.487.1395. *Pursuant to section 455.275(1), Florida Statutes, effective October.1, 2012, licensees licensed under Chapter 455,'F.S, must provide the Department with an email address if they have one. The emalls provided may be used for official communicationwith the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Acceptsi E: -av®- . Credit Card' Safe https:Mloridabuilding.org/prlpr app_dti.aspxlparam=wGEVXQwtDgvbSgAaZp3Crk2vSa/"2fegOlip3cPzPSPEkchxo6j6Vjgl %2bg%a3d%3d 2/2 ONEMO I etc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category:" U nd a rlayme nt Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS': `Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2015 1507.1.1 / R905.1.1 Material standard ASTM D226 2009 1507.1.1,1507.2.4, 1507.2.9.2 / Material standard ASTM D1970 2015 R905.1.1, R905.2:8.2 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507,11.2 / R905.11.2 Material standard ASTM D6163 2015 1507.11.2 / R905.11.2 Material standard ASTM .D6164 2011 1507.11.2 / R905.11.2 Material standard ASTM D6222 2011 1507.11.2 / R905.11.2 Material standard ASTM D6509 2015 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date Entity Examination "' Reference Date ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST.6049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017 ERD (TST 6049) Wind Uplift 11176.06.02 01/16/2603 ERD (TST 6049) TAS 103 PLYG-SC12115.08.17 08/08/2017 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) TAS 103 PLYG-SC13035.08.17 10/31/2017 ERD (TST 6049) ASTM D1970 P5110.04.07-1 04/11/2007 FM (TST 1867) Wind Uplift 3004091 01/12/2000 ERD (TST 6049) Wind'Uplift P9260.03.08 08/21/2008 [CC-E5 (EVL'2396) IBC Compliance ESR-1697 04/01/2019 ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 M-D (CER 1592) HVHZ Compliance NOA 17-0614.22 07/06/2017 ERD (TST 6049) Tensile Adhesion P31030.1109.1 11/30/2009 MTI (TST 2509) ASTM D4798 JX201-17A 04/01/2008 ERD (TST 6049) Wind Uplift P11030.11:09.2 11/20/2009 NEMO (TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/2018 ERD (TST 6049) ASTM D4977 P11030.11.09-3 11/30/2009 NEMO (TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019 ERD (TST 6049) ASTM D1970 P33360.06.10 06/25/2010 NEMO (TST 6049) ASTM D6163 45•PLYG-18-002.01.19-A 01/24/2019 ERD (TST 6049) TAS 103 P33370.03.11 03/02/2011 NEMO (TST 6049) ASTM D6222 4S-PLYG-18.0012.05.19-C 05/20/2019 ERD (TST 6049) Tensile Adhesion P33370.04.11 04/26/2011 NEMO (TST 6049) ASTM D1070 4j-PLYG-I9-SSUDL-OO.A 09/10/2019 ERD (T5T,6049) ASTM D1970 P37300.10.11 10/19/2611 NEMO (TST 6049) TAS 109 AS-PLYG-18-004.10.19-13 10/08/2019 ERD (TST 6049) TAS 103 P40390.08.12-1 08/06/2612 MEMO (TST 6049) TAS 103 4S-PLYG-18-004.10.19.1 10/08/2019 ERD (TST 6049) Tensile Adhesion P40390.08.12.2 08/07/2012 NEMO (TST6049) TAS 103 4S-PLYG-18-604.30.19-1. 10/09/2019 ERD (TST 6049) Tensile Adhesion C41420.09.123 09/11/2012 NEMD (TST 6049) TAS 103 4j-PLYG-19-SSUDL-01.A 10/10/2019 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 MEMO (TST 6049) TAS 103 4S-PLYG-18.004.12.19-F 12/18/2019 ERD (TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO (TST 6049) TAS 103 4j-PLYG-I9-SSUDL-02,A 01/02/20M ERD (TST 6049) Wind Uplift P1738.02.07-92 04/29/2013 NEMO (TST 6049) ASTM D1970 4S-PLY6-18-004.01.20.H 01/14/2020 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 NEMO (TST 6049) ASTM D1970 4S-PLYG-18-004.01.20.K 01/14/2020 ERD (TST 6049) ASTM D6164 P37590.03.13-3A 05/06/2013 NEMO (TST 6649) TAS 103 4S-PLYG-18-004.01.20.A 01/16/2020 ERD (TST 6049) ASTM D6509 P37590.03,13-1-R1 06/26/2013 NEMO (TST 6049) ASTM 06164 4S-PLYG-18-004.01.20.B OV16/2020 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 NEMO (TST 6049) ASTM D6222 45-PLYG-18-602.12.19-K-Ri 01/07/2020 ERD (TST 6049) ASTM D4601 P45940.09.13 09/04/2013 NEMO (TST 6049) TAS 103 PLYG-SC15855.05.20.A 05/29/2020 ,ERD (TST 6049) Wind Uplift' P11751.05.03-R1 11/26/2013 NEMO (TST 60491 TAS 103 4j-PLYG-20-5SUDL-01 07/06/2020 ERD (TST-\6049) Wind Uplift P11781.11.03-R1 11/26/2613 NEMO (TST 6049) ASTM D6222 4q-PLYG-I9-SSMB8-05.A 07/23/2020 ERD (TST 6049) 30/90 physicals P45270.05.14 05/12/2014 NEMO (TST 6049) ASTM D4798/D1623 41-PLYG-I9-SSUDL-05.A 09/10/2020 ERD (TST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 NEMO (TST 6049) ASTM D1970 4j-PLYG-20-SS0DL-05.A 09/30/2020 ERD (TST 6049) Tensile adhesion 6020.09.14-6 09/08/2014 NEMD (TST 6049) TAS 103 4j-PLYG-20-S5UDL-05.0 09/30/2020 ERD (TST 6049) Tensile adhesion P46520.10.14 10/03/2014 NEMO (TST 6049) TAS 103 4j-PLYG-20-SSUDL-11 09/30/2020 NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R27 Certificate of Authorization #32455 71" EDITION (2020) FBC NON-HVHZ EVALUATION f1.5259-1131 Polyglass Roof Underlayments Revision 27: 09/30/2020 Page 2 of 17 4.15 4.16 4.17 4.18 4.19 4.20 4.21 (ONEMOletc. PRODOcT r • Product Material Standard Plants) Description Polystick IR-Xe ASTM D1570 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforcedi with an aggregate surface Polystick MTS Plus ASTM D1970 FL, NV, Nominal 66-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 PA, TX membrane, glass fiber reinforced, surfaced with polyolefinic film surface Polystick MU-X ASTM D19701 FL, NV, PA . Nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface Polystic0T Ma ASTM D1970 FL, PAi TX Nominal 60-mil thick rubberized'asphalt waterproofing FRSA/TRI 09-18 membrane with a 190 g/M2 polyester fabric surface Polystick TU P FRSA/TRI 09-18 FL, PA, TX Nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface Polystick TU Plus ASTM D1970 FL, PA, TX Nominal'80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane, glass fiber reinforced; witha polyester fabric surface Polystick XFR ASTM D1970 NV, TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane; glass fiber reinforced, surfaced with a textured film surface 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LL"C nor Robert:Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guldance'unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance "with FBC.requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include :evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use offoam plastic insulation. 5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. I Polystick MU-) has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. NEMO ETC,'LLC. Evaluation Report P12060.02.09-R27 Certificate of Authorization #32455 7TH EDITION (2016) Fat NON-HVHZ EVALUATION FL5259-1131 •Polyglass Roof Underlayments Revision 27:09/30/2020 Page 4 of 17 ONEMOjetc. 5.6 Allowable Roof Covers: TABLE.1:' ;R00F,C0VER`0PTIONS' Asphalt Clay and Concrete Tile Metal Slate or Wood (I507.3) Slate -Type Underlayment Shingles Shingles Mechanical Adhesive- Panels Shingles Shingles Shakes (1907.9) (15oz2) Attach Set (1507.4) (1507.5) , (1507.7) (1507.8) Yes Yes Yes Yes Yes Yes Yes Yes Elastobase (Alternate to (as Base Sheet. (as Base Sheet, (Alternate to (Alternate to (Alternate to (Alternate to D226, (Alternate to D226, D226, Type II) See 5.8.3) See 5.83) .D226, Type II) . . D226, Type II) D226, Type II) Type II) Type li) Yes Yes Yes Yes Yes Yes Yes Yes ElastobaseP (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Altemateto (Altemateto (Alternate to D226, (Alternate to D226, D226, Type II) See 5.8.3) See 5.8.3) D226, Type ll) _ D226, Type Iq D226, Type II) Type II) Type ll) Yes Yes Polyglass Base No (as Base Sheet, (as Base Sheet, No No No No No See S.8.3) See 5.8.3) .. Yes Yes Polyglass G2 Base No (as Base Sheet, (as Base Sheet, No No No No No See 5.8.3) See 5.6.3) Elastoflex 56 G No Yes Yes No No No No No (See 5.6.1) Elastoflex S6 G FR No Yes No No No No No No Yes Yes HydraGuard Dual Pro Yes No No Yes Yes Yes ((oint strips, 1507.1.1.3 (joint strips, 1507.1.1.9 /R905.1.1.3) /R905.1.1.3) Yes Yes HydraGuard Tile Pro Yes Yes Yes (See 5.6.1) Yes Yes Yes (Jolntstrips, 1507.1.23 (Joint strips, 1507.1.1.3 R905.1.1.3) / R905.1.1.3) Mule -Hide SA-APP Cap Sheet No Yes Yes No No No No No (See 5:6.1) Mule -Hide SA-APP Cap Sheet (FR) No Yes Yes No No No No No (See 5.6A) Polyflex G No Yes Yes No No No No No (see 5.6.1) Polyflex G FR No Yes No No No No No. No Polyflex SA P No Ye's Yes No No No No No {see S:G.i} Polyflex SA P FR No Yes Yes No No No No No (Se 5.Yes Yes Polystick IR-Xe Yes No No No No Yes j)aint strips, 1507.1.1.3 (Joint strips, 1507.1.1.3 /R905.1.1,3) /R905.1.1:3) Yes Yes Polystick MTS Plus Yes Yes No Yes Yes Yes (joint strips, 1507.1.1.3 aointstrips, 15pz1.1.3 R905.1.1.3) Yes Yes PolystickMUX Yes No No Yes Yes Yes bointstrips, 15D7.11.3 Gointstrips, 1507.1.1.3 /R905.1.1.3) /R905.1.1.3). Yes Yes PO(T!stlek3TUM2Xm� No e6.1) Yes Yes NO (Jolntstrips, 1507.1.1.3 ijointstrips, 1507.1.1.3 (s / R905.1.1.3) / R905.1.1.3) Yes Yes Yes Polystick TU P No Yes (See 5.6.1) No No No (joint strips, 15D7.1.1.3 Qoint strips, 1507.1.1.3 R905.1.1.3)Yes Yes Yes PolysfickTU Plus Yes Yes (See56.1) Yes Yes Yes (Joint strips, .1507.1.1.3 (joint strips, 1507.1.1.3 / R905.1.1.3) / R905.1.1.3) Yes Yes Polystick XFR Yes Yes No Yes Yes Yes (jointstrips,1507.1.1.3 (Joint strips,1507.1.1.3 • / R905.1.1.3) / R905.1.1.31 NEMO ETC, I.I.C. Certifcote of Authorization p32455 7TR EDITION (2020) FBC NON-HVH2'EVALUATION Polyglass Roof Underlayments Evaluation Report P12060.02.09-R27 FL5259-R31 Revision 27: 09/30/2020 Page 5 of 17 NEMO I etc. 5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations. TABLE 1At:ALLOWABLE:UNDERLAYMENT/TILE=ADHESIVE'COMBINATIONS2 Underlayment Adhesive Florida Product Approval Polystick TU Max or Polystick TU Plus DAP Foam "Touch 'n Seal StormBond Roof Tile Adhesive' FL14506 HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick Dupont "Tile Bond'"" Roof Tile FL22525 TU Plus Adhesive' Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA- ICP Adhesives and Sealants APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, „ Polyset® AFI-160 FL6332 Polystick TU P or Polystick TU Plus Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA- ICP Adhesives and Sealants APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, "PolysetO RTA-1" FL6276 Polystick TU P or Polystick TO Plus 5.7 Allowable Substrates: TABLE 27 :SUBSTRATE OPTIONS FOR'ADHERED.UNDERLAYNIENTS" Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) HydraGuard Dual Pro, (Optional) ASTM plywood, OSB, Southern Yellow Pine or Huber Engineered HydraGuard Tile Pro, Polystick IR- Deck / D41 Woods "ZIP System" Panels ASTM D41 structural concrete Xe, Polystick MTS Plus, Polystick sheathing MU=X, Polystick TU Max, self- ASTM C1289 Type II Cla5s.1 polyisocyanurate, ASTM Polystick TU P, Polystick TU Plus, adhering Insulation (Optional) ASTM C1289Type Vpolyisocyanurate- composite, DensDeck Polystick XFR, Mule -Hide SA-APP D41 or WB-3000 Prime or SECUROCK Gypsum -Fiber Roof Board Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR)t Polyflex SA P or ga"s Sheeti;. N/A ASTM D226, Type R felt, Elastobase, Elastobase P or Mule- P.olyflex P FR Hide Nail Base Deck ASTM D41 structural concrete Insulation (Optional) ASTMDensDeck Prime or SECUROCK Gypsum -Fiber Roof Board 'Elastoflex S6 G or Elastoflex 56 G hot asphalt D41 FR ASTM D226, Type Il felt, Elastobase, Elastobase P, Mule- Base Sheet N/A Hide'Nail Base or Polyglass G2 Base Deck ASTM D41 structural concrete Insulation (Optional) ASTM DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board torch- Polyflex G or Polyflex G FR applied D41 Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass Base Sheet N/A G2 Base or Polyglass Base 2 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1127 certifcate of Authori2ation #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27: 09/30/2020 Page 6 of 17 OMEMO I etc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically "attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: •, FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition; Appendix A, Table 1(for Two - Ply Asphalt Applied Hot Mop Underlayment) . or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to,underlayment systems that ate not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet, or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -52.5 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to.meet project requirements to satisfaction of Authority Having Jurisdiction. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all 'OSB joints Base Ply: Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or PolystickTU Plus, self -adhered. #2 Maximum Design Pressure ==90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TO Max, Polystick TO P or PolystickTU Plus; self -adhered. C #3 Maximum Design Pressure = 97.5 psf: Deck: Min. 15/32-inch ;plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga: x l%" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet.project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS Plus, self=adhered. Underlayment: Mule -Hide SA-APP CapSheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or ;Polystick TO Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y4,' ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-Inch o.c. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R27 certificate of Authorization #32455 7T" EDITION (2020) FBC,NON-HVHZ EVALUATION FL5259-R31 Polygim Roof Underlayments Revision 27: 09/30/2020 Page 7 of 17 (NNEMOletc. #5 Maximum Design Pressure = -135 psf: Deck: Min. 15/32-inch plywood to meet project requirements. to satisfactionof.Authority HavingJurisdiction. Primer: (Optional)' PG100 or ASTM 641 \ Base Ply: (Optional) Polystick MTS Plus, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P.or Polystick TU Plus, self -adhered. #6 Maximum Design_ Pressure = -315 psf: Deck: Structural concrete to meet project'requirements to satisfaction of Authority Having Jurisdiction. Primer: P6300 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or-Polystick TU Plus, self -adhered. #7 Maximum Design Pressure = -622.5 psf: Deck: Structural concrete to meet project requirements to satlsfaction.of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex S6 G, applied in full mapping of hot asphalt or Polyflex G, torch -applied. #8 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design. Pressure of -45 psf. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the :selected assembly,shall meet or exceed at least the Zone 1 design pressure determined .in accordance with FBC 1609'or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure,criteria. Commonly used methods are ANSI/SPRI W01, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an,asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29'(February 2020) for enhancements. #9 Maximum Design Pressure = -30.0 psf*: Deck: Min. 15/32-inch.OSB to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide sA-APP Cap sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #10 Maximum Design Pressure =-37.5 psf*: Deck: Min.15/92-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base,(poly-film top surface) Fasteners: 11 ga. x 1.25-inch long x 1=inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch, o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus; self -adhered. #11 Maximum Design Pressure = -37.5 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base'Sheet: One (1) or two (2) layers ASTM D226, Type II felt. Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap. nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, LLC. Evaluation Report P12060.02.09-R27 Certificate of Authorization #32455 77H EDITION (2020) FBC NON-HVHZ,EVALUATION FL5259-1131 Polyglas4 Roof Underlayments Revision27: 09/30/2020 Page 8 of 17 ONEMOletc. #12 Maximum Design Pressure = -45 psf`: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga, x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8Anch diameter tin caps Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering Underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-'APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #13 Maximum Design Pressure = -45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type 11 felt Fasteners: 11 ga. x 1.25-inch long x3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 97inch o.c. at the 2-inch wide side laps and 9-inch o.c, at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt. 414 Maximum Design Pressure = -45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #15 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly-fllm top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (optional) Polystick MTS Pius, self -adhered. Underlayment:. Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P'or Polystick TU Plus, self -adhered. #16 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps. 5pacingi 6-inch o.c. at'the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt. 417 Maximum Design Pressure = 45.0130: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #18 'Maximum Design :Pressure = -52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. attwo (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, LLC. Evaluation Report 1312060.02.09-1427 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVH2 EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27: 09/30/2020 Page 9 of 17 ONEMO I etc. #19 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) 'Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-Inch wide side laps and .6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or PolystickTU Plus, self -adhered. #20 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface -for hot=asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full Mopping of hot asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure = -60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction. of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex 56 6, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #22 Maximum Design Pressure = -60 psf: Deck: Min: 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12'Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch:o.c. at the 4-inch wide side laps and 12-Inch o.c. attwo (2) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch:applied. #23 Maximum DesignPressure = -60.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail. Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the-3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule-Hide'SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered. #24 Maximum Design Pressure = -60.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1,.OSB sheathing to meet.project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c, at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt. #25 Maximum Design Pressure = -60.0 psf: Deck: APA rated, 7/16 CAT, 0.419 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. NEMO ETC, LLC. Evaluation Report P32060.02.09-R27 Certificate bfAuthorization #32455 f" EDITION (2020)'FBC NON-HVH2 EVALUATION F1.5259-1131 Polyglass Roof Underlayments Revision 27: 09/30/2020 Page 10 of 17 ONEMOletc. #26 Maximum Design Pressure = -67.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch-applled underlayment) Fasteners: '12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6"G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #27 Maximum Design Pressure = -67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, OSB •sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or,Mule-Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per .plate installed 180°'into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Primer: (Optional) PG100 or ASTM D4.1 primer applied to stress plates. Base Ply: (0ptional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU :P or Polystick TU Plus, self -adhered. #28 Maximum Design Pressure = -67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180` into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c, at the 4-inch wide side laps and 12-inch o.c. at,two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #29 Maximum Design Pressure = -67.5 psf: Deck: APA ratedi 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied". #30 Maximum .Design Pressure = -75 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use.of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HO with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), TrufastHD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or torch-applled or Polyflex G, torch -applied. #31 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hat-asph"alt or torch -applied cap or poly -film surface for'torch-applied cap) Fasteners: Simplex MAXX Cap fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #32 Maximum Design Pressure = -90 psf: Deck: Min. 1S/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch:applied cap) Fasteners: OMG #12 Standard Roofgrip or CMG #14 Heavy Duty with OMG 3" Round .Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt or.Polyflex G, torch -applied. NEW ETC, I.I.C. Evaluation Report P12060.02.09-R27 Certificate of Authorization #32455 7T" EDITION (2620) FBC NON-HVH2 EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27: 09/30/2020 Page 11of17 1 ONEMOletc. #33 'Maximum Design.Pressure = -90 psf: Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing! 6-inch o.c: at the 4-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex 96 G, applied in full mopping of hot asphalt. #34 Maximum Design Pressure = -96 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: 'Polyglass 62 Base or Polyglass Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" GalValume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-Inch o.c. at four (4) equally spaced 'staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #35 Maximum Design Pressure = -90.6 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -,Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #36 Maximurn Design Pressure= 90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: IElastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #37 Maximum Design Pressure = -90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c, at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #38 Maximum Design Pressure = -97.5 psf: Deck: Min.19/32=inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase,or Mule -Hide Nall Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, LLC, Evaluation Report P12060.02.09-R27 Certificate ofAutharization #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass RoofUnderiayments Revision 27: 09/30/2020 Page 12 of 17 (NNEMOJetc�. #39 Maximum Design Pressure = -97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PDlystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #40 Maximum Design Pressure = -97.5 asf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, 056 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the-4-Inch wide side laps and'6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastaflex S6 G, applied in full mopping of hot asphalt. #41 Maximum Design Pressure = -97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase br Polyglass Base Fasteners: Simplex MAXXCap Fasteners Spacing: 6-inch o.c: at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #42 Maximum Design Pressure = -105 psf: Deck: Min. 15/32Anch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o:c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. 'Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #43 Maximum Design Pressure = 405.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1,'0SB sheathingto meet project requirements to'satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-Inch o.c, at three (3) equally spaced staggered center rows. Primer: PG100 cir ASTM A41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APPCap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #44 Maximum Design Pressure = 405.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathingto meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the .width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1127 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVH2 EVALUATION FL52S9-R31 Polyglass Roof Uriderlayments Revision 27: 09/30/2020 Page 13 of 17 ONEMO I etc. #45 Maximum Design Pressure = -105.0 psf: Deck: APA rated, 7/16 CAT, 0A18 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6=inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied: #46 Maximum Design Pressure = -112.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdictlon. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c. at the 4-inch wide side laps'and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS Plus, self -adhered Underlayment: Mule -'Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #47 Maximum Design Pressure = -120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrlp or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. ° Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or.Polyflex G, torch -applied. #48 Maximum Design Pressure = =120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12.DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch ox. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #49 Maximum Design Pressure.=-127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (11 screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #50 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c, at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #51 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or PDlyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch b.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R21 Certificate of Authorization #32455 '7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27: 09/30/2020 Page 14 of 17 ONEMO I etc. 5;9 Exposure Limitations: TABLE I. EXPOSURELIMITATIONS Underlaytnent Prepared Roof Cover Installation Type Maximum Exposure (days) Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base Mechanically attached 30 Polystick IR-Xe or Polystick MU-X Mechanically attached 90 HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR Any type (per Table 1) 180 Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR Adhesive -set tile roof system 180 Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in' direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE- SLIPPAGE LIMITATIONS FOR DIRECT -DECK Tim.INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Staging Slope Elastoflex S6 G or 56 G FR Flat or Lugged 6-tile stack (4 over 2) Prohibited without battens HydraGuard Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS Plus Flat 6-tile stack (4 over 2) 5:12 Lugged- 6-tile stack (4 over 2) 4:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polystick XFR Flat or Lugged Prohibited Without battens Prohibited without battens NEMO ETC, LLC. Evaluation Report P12060.02.09-R27 certificate ojAuthorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F15259-1131 Polyglass Roof Underlayments Revision 27: 09/30/Z020 Page '15'of 17 NMEMO I etc. 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the 'Limitations set forth in'Section 5 heroin and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and':prime the substrate'(if applicable)'. 6.3 Elastobase,11astobase Pi' or.Mule-Hide 4'alk9ase: 6.3.1 Non -Tile Applications: Shall be installed in compliance withrequirements for `an approved mechanically attached .underlayment (ASTM D226, Type 11) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex 56 G FR in hot asphalt or PolyflexG or Polyflex G FR, torch applied. Roof cover. limitations are those are those associated with the top -layer, uriderlayrnent, as set forth in Table 1. 6.3.2 Tile Applications: 6.3.2.1' .Elastobase (poly -film top), Elastobase P (poly -film top) and 'Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU.Plus, PolystickXFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or PolyflexG FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table .1. Refer to Section 5.8.3.2 herein for attachment requirements'. 6.3.2.2 EIaastobase (sanded-top)and Elastobase P (sanded-top)e are limited to use as a mechanically attached base sheet in the'?WO- PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and 'Clay Roof Tile Installation Manual, Sixth Edition, followed by Elastoflex S6 G, Elastoflex 56 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380); asphalt -applied or Polyflex G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. • When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6 G, Elastoflex S6 G.FR or FBC Approved Mineral Surfaced -Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 or Section 5.8.3.2 herein for attachment requirements. • When Elastobase (sanaed-top) or Elastobase P (sanded -top) is followed by torch -applied Polyflex G or Polyflex G FR, refer to Section 5.8.3.2 herein for attachment requirements. 6.4 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule-Hide.SA-APP Cap Sheet, Mule -Hide SA=APP Cap Sheet' 11),.Polyflex SA,P, Polyflex SA'P,FR,-Polystick,IR-Xe,,Polystick MTS-Plus, Polystick MU-X, Polystick TU Max, Polystick TU P; Polystick-TU Plus -or. Polystick XFR: 6.4.1 General: All seal -lap seams (selvage laps) must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile"Pro, align the edge of the top sheet to the end of the glue pattern (the Sheet will overlap the fabric). View of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1127 certificate of Authorization #32455 T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27: 09/30/2020 Page 16 of 17 . . s ON EMO I etc. 6.41 Non -Tile Applications: Shaft be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) :in FSC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1'or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type;ll felt, Elastobase, Elastobase P or Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.3 Tile Applications (excludes HydraGuard Dual Pro Polystick lR-k and Polystick MU-X): Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in .FRSA/TRi Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile'staging limitations. 6.4.4 Multi -Ply Underlavment Systems',- Polystick MTS Plus or Polystick XFRfollowed by HydraGuard Tile Pro, Polyflex SA'P,'Polystick-MTS Plus, Polystick MU=X, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use 'under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TO P or Polystick TU Pius is allowable for use under adhesive -set tile systems. Limits of use are those • associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlaymentsystem is desired. 6.5 . Elasto#lex S6 G or Ela"stoflex 56 G FR: " 6 .5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the 'Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, and the manufacturer's installation;instructions. Refer to Section 5.8.2'and 5.8:3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. :6.6 Polyf1ek,G.drPo1yf1exG"FR: 6.6:1 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind "Concrete and Clay 'Roof Tile Installation Manual, "Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging'limitations. As required by the Building Official: or Authority Having Jurisdiction to properly.evaluate the installation of this product. Contact the named CIA entity for rhanufacturing'facilities covered'by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified.material standards: 'UL LLC—.CtUA9625;'(414) 248-6409; Karen.buchmann@ul.com END OF EVALUATION REPORT - NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R27 Cerripcote of Autharization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass.Roof Underlayments Revision 27: 09/30/2020 Page 17 of 11