Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Alford Family LLC Builder Name: Street: TBD N. 45th Street-1431-801-0073-000-8 Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL, 34946 Permit Number: Owner: Alford Family LLC Jurisdiction: St. Lucie County DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Typeg1636.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block- Int Insul, Exterior R=4.1 1431.30 ftz b. Frame -Wood, Adjacent R=11.0 205.33 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 11. Ceiling Types (1511.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1511.00 ftz 6. Conditioned floor area above grade (ftz) 1511 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. NIA R= ftz 7. Windows(219.6 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Laundry R ftz 6 80 a. U-Factor: Sgl, U=1.05 219.58 ftz SHGC: SHGC=0.25 b. U-Factor: N/A ftz 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEER:16.00 c. U-Factor: N/A ftz SHGC: Area Weighted Average Overhang Depth: 3.761 ft. 14.Heatingsystems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Electric Tankless Cap:1 gallons 9. Floor Types (1511.0 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 1511.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 16. Credits CF, Pstat Glass/Floor Area: 0.145 Total Proposed Modified Loads: 53.58 PASS Total Baseline Loads: 53.96 1 hereby certify that the plans and specifications covered by Review of the plans and O�1$E S'r this calculation are in compliance with the Florida Energy specifications covered by this rr Code. calculation indicates compliance with the Florida Energy Code. ti n+nr'�•�; -'='.-"�,O PREPARED A-0 1-1 Before construction is completedDATE: this building will be inspected for4i"" compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energ o e. WE'C¢� OWNER/A T: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (11402.4.1.2). 12/29/202012:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMAKY t;HI=k:KLIS I Kt=PUK I PROJECT Title: Alford Family LLC Bedrooms: 3 Address Type: Street Address BuildingType: User Conditioned Area: 1511 Lot # Owner Name: Alford Family LLC Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: TB N. 45th Street -14 Permit Office: St. Lucie County CrossVentilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34946 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1511 14203.4 SPACES Number Name Area Volume Ntchen Occupants Bedrooms InfillD Finished Cooled Heated 1 Dining 119 1118.6 No 0 1 Yes Yes Yes 2 Kitchen 156 1466.4 Yes 1 1 Yes Yes Yes 3 Bedroom 3 168 1579.2 No 0 1 1 Yes Yes Yes 4 Great Room 307 2885.8 No 2 1 Yes Yes Yes 5 Master Bedroom 225 2115 No 2 1 1 Yes Yes Yes 6 WIC1 30 282 No 0 1 Yes Yes Yes 7 WIC 2 25 235 No 0 1 No Yes Yes 8 M Bath 91 855.4 No 0 1 Yes Yes Yes 9 Bedroom 2 177 1663.8 No 0 1 1 Yes Yes Yes 10 Laundry 63 592.2 No 0 1 Yes Yes Yes 11 Foyer 63 592 No 0 1 Yes Yes Yes 12 Bath 2 45 423 No 0 1 No Yes Yes 13 Hall 42 394.8 No 0 1 No Yes Yes FLOORS # FloorType Space Perimeter Perimeter R-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Dining 22 ft 119 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulatio Ktchen 13 ft 156 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulatio Bedroom 3 33 ft 168 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulatio Great Room 15 ft 307 ft2 ---- 1 0 0 12/29/202012:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PedmeterR-Value Area JoistR-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio Master Bedroom 29 ft 225 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulatio WIC 1 5 ft 30 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulatio WIC 2 1 ft 25 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulatio M Bath 7 ft 91 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 2 12 ft 177 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Laundry 9 ft 63 ft2 ---- 1 ' 0 0 11Slab-On-Grade Edge Insulatio Foyer 7 ft 63 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio Bath 2 1 ft 45 ft2 ---- 1 0 0 13Slab-On-Grade Edge Insulatio Hall 1 ft 42 ft2 ---- 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Compositionshingles 1637 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.62 ATTIC Area RBS IRCC V # Type Ventilation Vent Ratio (1 in) 1 Fullattic Vented 150 1511 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac TrussType 1 UnderAttic(Vented) Dining 30 Batt 119ft2 0.1 Wood 2 UnderAttic(Vented) Kitchen 30 Batt 156ft2 0.1 Wood 3 UnderAttic (Vented) Bedroom 3 30 Batt 168 ft2 0.1 Wood 4 UnderAttic (Vented) Great Room 30 Batt 307 ft2 0.1 Wood 5 Under Attic (Vented) Master Bedroom 30 Batt 225 ft2 0.1 Wood 6 UnderAttic (Vented) WIC 1 30 Batt 30 ft2 0.1 Wood 7 UnderAttic (Vented) WIC 2 30 Batt 25 ft2 0.1 Wood 8 UnderAttic(Vented) MBath 30 Batt 91ft2 0.1 Wood 9 UnderAttic (Vented) Bedroom 2 30 Batt 177 ft2 0.1 Wood 10 Under Attic (Vented) Laundry 30 Batt 63 ft2 0.1 Wood 11 UnderAttic (Vented) Foyer 30 Batt 63 ft2 0.1 Wood 12 UnderAttic (Vented) Bath 2 30 Batt 45 ft2 0.1 Wood 13 Under Attic (Vented) Hall 30 Batt 42 ft2 0.1 Wood 12/29/202012:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space 1 N Exterior Concrete Block- Int Insul Dining 4.1 12 0 9 5 113.0 ft2 0 0 0.4 0 2 W Exterior Concrete Block- Int Insul Dining 4.1 10 0 9 5 94.2 ft2 0 0 0.4 0 3 W Exterior Concrete Block- Int Insul Kitchen 4.1 13 0 9 5 122.4 ft2 0 0 0.4 0 4 E Exterior Concrete Block- Int Insul Bedroom 3 4.1 7 0 9 5 65.9 ft2 0 0 0.4 0 5 S Exterior Concrete Block- Int Insul Bedroom 3 4.1 12 0 9 5 113.0 ft2 0 0 0.4 0 6 W Exterior Concrete Block- Int Insul Bedroom 3 4.1 14 0 9 5 131.8 ft2 0 0 0.4 0 7 N Exterior Concrete Block- Int InsulGreat Room 4.1 15 0 9 5 141.3 ft2 0 0 0.4 0 8 N Exterior Concrete Block- Int InsuMaster Bedro 4.1 14 0 9 5 131.8 ft2 0 0 0.4 0 9 E Exterior Concrete Block- Int I nsuMaster Bedro 4.1 15 0 9 5 141.3 ft2 0 0 0.4 0 10 E Exterior Concrete Block- Int Insul WIC 1 4.1 5 0 9 5 47.1 ft2 0 0 0.4 0 11 E Exterior Concrete Block- Int Insul M Bath 4.1 7 0 9 5 65.9 ft2 0 0 0.4 0 12 E Exterior Concrete Block- Int Insul Bedroom 2 4.1 12 0 9 5 113.0 ft2 0 0 0.4 0 13 W Exterior Concrete Block- Int Insul Laundry 4.1 9 0 9 5 84.8 ft2 0 0 0.4 0 _ 14 S Exterior Concrete Block- Int Insul Foyer 4.1 7 0 9 5 65.9 ft2 0 0 0.4 0 15 W Garage Frame -Wood Laundry 11 7 9 4 65.3 ft2 0.23 0.4 0 16 W Garage Frame -Wood Bedroom 2 11 15 9 4 140.0 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S insulated Foyer None .39 5 11 8 47.3 ft2 2 W Wood Laundry None .39 2 8 6 8 17.8 ft2 WINDOWS Orientation shown istheentered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 1.05 0.25 Y 15.0 ft2 2 It 0 in 1 ft 4 in None None 2 W 2 Metal Low-E Single Yes 1.05 0.25 Y 15.4 ft2 2 ft 0 in 1 ft 4 in None None 3 S 5 Metal Low-E Single Yes 1.05 0.25 Y 30.8 ft2 2 It 0 in 1 ft 4 in None None 4 N 7 Metal Low-E Single Yes 1.05 0.25 Y 48.0 ft2 6 ft 0 in 1 ft 4 in None None 5 N 8 Metal Low-E Single Yes 1.05 0.25 Y 48.7 ft2 6 ft 0 in 1 It 4 in None None 6 E 9 Metal Low-E Single Yes 1.05 0.25 Y 30.8 ft2 2 It 0 in 1 ft 4 in None None 7 E 11 Metal Low-E Single Yes 1.05 0.25 Y 15.4 ft2 2 ft 0 in 1 ft 4 in None None 8 E 12 Metal Low-E Single Yes 1.05 0.25 Y 15.4 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 462 ft2 462 ft2 21 ft 9.4 ft 11 12/29/2020 12:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000358 1420.3 77.92 146.29 .1155 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # SystemType Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 30 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Laundry 0.95 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None fta DUCTS / --- Supply --- V # Location R-Value Area --- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 80 ftz Attic 20 ftz Default Leakage Laundry (Default) (Default) 1 1 TEMPERATURES Programabl[eThermostat: Y Heating H Jan H Feb HX Mar [ I Jan Feb Mar Ceiling Fans: Apr May Apr may lXl Jun Jun lXi Jul Jul LXAug Sep Oct Nov � Aug ri Sep Ot €X� Nov Dec H DecVenting 12/29/2020 12:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ThermostatSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ftz Off 0.3 Dining Default(8lbs/sq.ft. ftz ft 0.3 Kitchen Default(8lbs/sq.ft. ftz ft 0.3 Bedroom 3 Default(8lbs/sq.ft. ft2 ft 0.3 Great Room Default(B lbs/sq.ft. ftz ft 0.3 Master Bedroom Default(8lbs/sq.ft. ftz ft 0.3 WIC 1 Default(8lbs/sq.ft. ftz ft 0.3 WIC 2 Default(8lbs/sq.ft. ftz ft 0.3 M Bath Default(8lbs/sq.ft. ftz ft 0.3 Bedroom 2 Default(8lbs/sq.ft. ftz ft 0.3 Laundry Default(81bs/sq.ft. ftz ft 0.3 Foyer Default(81bs/sq.ft. ftz ft 0.3 Bath 2 Default 8lbs/s .ft. ftz ft 0.3 Hall 12/29/202012:13 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Alford Family LLC Builder Name: Street: TBD N. 45th Street-1431-801-0073-000-8 Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34946 Permit Number: Y U Owner: Alford Family LLC Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extende' Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. . HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids coverI between fire sr)r*nkler e d wallso s a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 12129/202012:13 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. TBD N. 45th Street - 1431-801-0073-000-8, Fort Pierce, FL, 34946 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows- Description a. U-Factor: Sgl, U=1.05 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A New (From Plans) 10. Wall Type and Insulation Detached a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 3 d. N/A 11. Ceiling Type and insulation level No a. Under Attic (Vented) 1511 b. N/A Area c. N/A 219.58 ftz 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH: Laundry ftz 13. Cooling systems ftz a. Central Unit ftz 3.761 ft. 0.250 Area ftz 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1511.00 ftz b. N/A R= ftz c. N/A R= ftz 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code omph t features. Builder Signatur Date: 3 Address of New H e: !, City FL Zip:���Q �L Insulation Area R=4.1 1431.30 ftz R=11.0 205.33 ftz R= ft2 R= ftz Insulation Area R=30.0 1511.00 ftZ R= ftZ R= ftz R ftz 6 80 kBtu/hr Efficiency 30.0 SEER:16.00 kBtu/hr Efficiency 27.0 COP:1.00 Cap: 1 gallons EF: 0.95 CF, Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/29/2020 12:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1