HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Alford Family LLC
Builder Name:
Street: TBD N. 45th Street-1431-801-0073-000-8
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34946
Permit Number:
Owner: Alford Family LLC
Jurisdiction: St. Lucie County
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wall Typeg1636.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block- Int Insul, Exterior
R=4.1 1431.30 ftz
b. Frame -Wood, Adjacent
R=11.0 205.33 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftz
11. Ceiling Types (1511.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1511.00 ftz
6. Conditioned floor area above grade (ftz) 1511
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. NIA
R= ftz
7. Windows(219.6 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Laundry
R ftz
6 80
a. U-Factor: Sgl, U=1.05 219.58 ftz
SHGC: SHGC=0.25
b. U-Factor: N/A ftz
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
30.0 SEER:16.00
c. U-Factor: N/A ftz
SHGC:
Area Weighted Average Overhang Depth: 3.761 ft.
14.Heatingsystems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ftz
15. Hot water systems
SHGC(AVG): N/A
a. Electric Tankless
Cap:1 gallons
9. Floor Types (1511.0 sqft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation R=0.0 1511.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
16. Credits
CF, Pstat
Glass/Floor Area: 0.145 Total Proposed Modified Loads: 53.58
PASS
Total Baseline Loads: 53.96
1 hereby certify that the plans and specifications covered by
Review of the plans and
O�1$E S'r
this calculation are in compliance with the Florida Energy
specifications covered by this
rr
Code.
calculation indicates compliance
with the Florida Energy Code.
ti n+nr'�•�; -'='.-"�,O
PREPARED A-0
1-1
Before construction is completedDATE:
this building will be inspected for4i""
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Energ o e.
WE'C¢�
OWNER/A T:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (11402.4.1.2).
12/29/202012:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMAKY t;HI=k:KLIS I Kt=PUK I
PROJECT
Title: Alford Family LLC
Bedrooms: 3
Address Type:
Street Address
BuildingType: User
Conditioned Area: 1511
Lot #
Owner Name: Alford Family LLC
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
TB N. 45th Street -14
Permit Office: St. Lucie County
CrossVentilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type: Detached
FL, 34946
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1511 14203.4
SPACES
Number Name
Area Volume Ntchen Occupants
Bedrooms
InfillD
Finished Cooled
Heated
1 Dining
119 1118.6 No
0
1
Yes
Yes
Yes
2 Kitchen
156 1466.4 Yes
1
1
Yes
Yes
Yes
3 Bedroom 3
168 1579.2 No
0
1
1
Yes
Yes
Yes
4 Great Room
307 2885.8 No
2
1
Yes
Yes
Yes
5 Master Bedroom
225 2115 No
2
1
1
Yes
Yes
Yes
6 WIC1
30 282 No
0
1
Yes
Yes
Yes
7 WIC 2
25 235 No
0
1
No
Yes
Yes
8 M Bath
91 855.4 No
0
1
Yes
Yes
Yes
9 Bedroom 2
177 1663.8 No
0
1
1
Yes
Yes
Yes
10 Laundry
63 592.2 No
0
1
Yes
Yes
Yes
11 Foyer
63 592 No
0
1
Yes
Yes
Yes
12 Bath 2
45 423 No
0
1
No
Yes
Yes
13 Hall
42 394.8 No
0
1
No
Yes
Yes
FLOORS
# FloorType
Space Perimeter Perimeter R-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Dining 22 ft
119 ft2
----
1 0
0
2 Slab -On -Grade Edge Insulatio
Ktchen 13 ft
156 ft2
----
1 0
0
3 Slab -On -Grade Edge Insulatio
Bedroom 3 33 ft
168 ft2
----
1 0
0
4 Slab -On -Grade Edge Insulatio
Great Room 15 ft
307 ft2
----
1 0
0
12/29/202012:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType
Space Perimeter PedmeterR-Value
Area
JoistR-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
Master Bedroom 29 ft
225 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio
WIC 1 5 ft
30 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulatio
WIC 2 1 ft
25 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulatio
M Bath 7 ft
91 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulatio
Bedroom 2 12 ft
177 ft2
----
1
0
0
10SIab-On-Grade Edge Insulatio
Laundry 9 ft
63 ft2
----
1 '
0
0
11Slab-On-Grade Edge Insulatio
Foyer 7 ft
63 ft2
----
1
0
0
12SIab-On-Grade Edge Insulatio
Bath 2 1 ft
45 ft2
----
1
0
0
13Slab-On-Grade Edge Insulatio
Hall 1 ft
42 ft2
----
1
0
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Compositionshingles 1637 ft2
0 ft2
Medium
N
0.6
No 0.9
No 0
22.62
ATTIC
Area
RBS
IRCC
V # Type
Ventilation
Vent Ratio (1 in)
1 Fullattic
Vented
150
1511 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
TrussType
1 UnderAttic(Vented)
Dining
30
Batt
119ft2
0.1
Wood
2 UnderAttic(Vented)
Kitchen
30
Batt
156ft2
0.1
Wood
3 UnderAttic (Vented)
Bedroom 3
30
Batt
168 ft2
0.1
Wood
4 UnderAttic (Vented)
Great Room
30
Batt
307 ft2
0.1
Wood
5 Under Attic (Vented)
Master Bedroom
30
Batt
225 ft2
0.1
Wood
6 UnderAttic (Vented)
WIC 1
30
Batt
30 ft2
0.1
Wood
7 UnderAttic (Vented)
WIC 2
30
Batt
25 ft2
0.1
Wood
8 UnderAttic(Vented)
MBath
30
Batt
91ft2
0.1
Wood
9 UnderAttic (Vented)
Bedroom 2
30
Batt
177 ft2
0.1
Wood
10 Under Attic (Vented)
Laundry
30
Batt
63 ft2
0.1
Wood
11 UnderAttic (Vented)
Foyer
30
Batt
63 ft2
0.1
Wood
12 UnderAttic (Vented)
Bath 2
30
Batt
45 ft2
0.1
Wood
13 Under Attic (Vented)
Hall
30
Batt
42 ft2
0.1
Wood
12/29/202012:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar Belo w
Space
1
N
Exterior
Concrete Block- Int Insul Dining
4.1
12
0
9 5
113.0 ft2
0
0
0.4
0
2
W
Exterior
Concrete Block- Int Insul Dining
4.1
10
0
9 5
94.2 ft2
0
0
0.4
0
3
W
Exterior
Concrete Block- Int Insul Kitchen
4.1
13
0
9 5
122.4 ft2
0
0
0.4
0
4
E
Exterior
Concrete Block- Int Insul Bedroom 3
4.1
7
0
9 5
65.9 ft2
0
0
0.4
0
5
S
Exterior
Concrete Block- Int Insul Bedroom 3
4.1
12
0
9 5
113.0 ft2
0
0
0.4
0
6
W
Exterior
Concrete Block- Int Insul Bedroom 3
4.1
14
0
9 5
131.8 ft2
0
0
0.4
0
7
N
Exterior
Concrete Block- Int InsulGreat Room
4.1
15
0
9 5
141.3 ft2
0
0
0.4
0
8
N
Exterior
Concrete Block- Int InsuMaster Bedro
4.1
14
0
9 5
131.8 ft2
0
0
0.4
0
9
E
Exterior
Concrete Block- Int I nsuMaster Bedro
4.1
15
0
9 5
141.3 ft2
0
0
0.4
0
10
E
Exterior
Concrete Block- Int Insul WIC 1
4.1
5
0
9 5
47.1 ft2
0
0
0.4
0
11
E
Exterior
Concrete Block- Int Insul M Bath
4.1
7
0
9 5
65.9 ft2
0
0
0.4
0
12
E
Exterior
Concrete Block- Int Insul Bedroom 2
4.1
12
0
9 5
113.0 ft2
0
0
0.4
0
13
W
Exterior
Concrete Block- Int Insul Laundry
4.1
9
0
9 5
84.8 ft2
0
0
0.4
0
_ 14
S
Exterior
Concrete Block- Int Insul Foyer
4.1
7
0
9 5
65.9 ft2
0
0
0.4
0
15
W
Garage
Frame -Wood Laundry
11
7
9 4
65.3 ft2
0.23
0.4
0
16
W
Garage
Frame -Wood Bedroom 2
11
15
9 4
140.0 ft2
0.23
0.4
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
insulated Foyer
None
.39
5
11
8
47.3 ft2
2
W
Wood Laundry
None
.39
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown istheentered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Low-E Single Yes
1.05
0.25
Y
15.0 ft2
2 It 0 in
1 ft 4 in
None
None
2
W 2
Metal Low-E Single Yes
1.05
0.25
Y
15.4 ft2
2 ft 0 in
1 ft 4 in
None
None
3
S 5
Metal Low-E Single Yes
1.05
0.25
Y
30.8 ft2
2 It 0 in
1 ft 4 in
None
None
4
N 7
Metal Low-E Single Yes
1.05
0.25
Y
48.0 ft2
6 ft 0 in
1 ft 4 in
None
None
5
N 8
Metal Low-E Single Yes
1.05
0.25
Y
48.7 ft2
6 ft 0 in
1 It 4 in
None
None
6
E 9
Metal Low-E Single Yes
1.05
0.25
Y
30.8 ft2
2 It 0 in
1 ft 4 in
None
None
7
E 11
Metal Low-E Single Yes
1.05
0.25
Y
15.4 ft2
2 ft 0 in
1 ft 4 in
None
None
8
E 12
Metal Low-E Single Yes
1.05
0.25
Y
15.4 ft2
2 ft 0 in
1 ft 4 in
None
None
GARAGE
#
FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
462 ft2 462 ft2
21 ft
9.4 ft
11
12/29/2020 12:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000358
1420.3 77.92 146.29 .1155 6
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
COP:1 27 kBtu/hr 1
sys#1
COOLING SYSTEM
# SystemType
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 16 30 kBtu/hr cfm 0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Electric Tankless
Laundry
0.95 1 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
fta
DUCTS
/ --- Supply ---
V # Location R-Value Area
--- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic 6 80 ftz
Attic
20 ftz Default Leakage Laundry (Default) (Default)
1 1
TEMPERATURES
Programabl[eThermostat: Y
Heating H Jan H Feb HX Mar
[ I Jan Feb Mar
Ceiling Fans:
Apr May Apr may lXl Jun Jun lXi Jul Jul LXAug Sep Oct Nov
� Aug ri Sep Ot €X� Nov
Dec
H DecVenting
12/29/2020 12:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ThermostatSchedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ftz
Off
0.3
Dining
Default(8lbs/sq.ft.
ftz
ft
0.3
Kitchen
Default(8lbs/sq.ft.
ftz
ft
0.3
Bedroom 3
Default(8lbs/sq.ft.
ft2
ft
0.3
Great Room
Default(B lbs/sq.ft.
ftz
ft
0.3
Master Bedroom
Default(8lbs/sq.ft.
ftz
ft
0.3
WIC 1
Default(8lbs/sq.ft.
ftz
ft
0.3
WIC 2
Default(8lbs/sq.ft.
ftz
ft
0.3
M Bath
Default(8lbs/sq.ft.
ftz
ft
0.3
Bedroom 2
Default(8lbs/sq.ft.
ftz
ft
0.3
Laundry
Default(81bs/sq.ft.
ftz
ft
0.3
Foyer
Default(81bs/sq.ft.
ftz
ft
0.3
Bath 2
Default 8lbs/s .ft.
ftz
ft
0.3
Hall
12/29/202012:13 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Alford Family LLC Builder Name:
Street: TBD N. 45th Street-1431-801-0073-000-8 Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL , 34946 Permit Number:
Y
U
Owner: Alford Family LLC Jurisdiction: St. Lucie County
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attics aces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extende'
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed. .
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
coverI between fire sr)r*nkler e d wallso s
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
12129/202012:13 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
TBD N. 45th Street - 1431-801-0073-000-8, Fort Pierce, FL, 34946
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows- Description
a. U-Factor: Sgl, U=1.05
SHGC: SHGC=0.25
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
3
d. N/A
11. Ceiling Type and insulation level
No
a. Under Attic (Vented)
1511
b. N/A
Area
c. N/A
219.58 ftz
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Attic, AH: Laundry
ftz
13. Cooling systems
ftz
a. Central Unit
ftz
3.761 ft.
0.250
Area
ftz
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1511.00 ftz
b. N/A R= ftz
c. N/A R= ftz
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code omph t features.
Builder Signatur Date: 3
Address of New H e: !, City FL Zip:���Q �L
Insulation Area
R=4.1 1431.30 ftz
R=11.0 205.33 ftz
R=
ft2
R=
ftz
Insulation
Area
R=30.0
1511.00 ftZ
R=
ftZ
R=
ftz
R ftz
6 80
kBtu/hr
Efficiency
30.0
SEER:16.00
kBtu/hr Efficiency
27.0 COP:1.00
Cap: 1 gallons
EF: 0.95
CF, Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12/29/2020 12:13 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1