Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NOA 18-0503.06
MIAMD1ADE MIAMI—DADE COUNTY, FLORIDA • PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.2ov/economy Lawson Industries, Inc. 8501 NW 90' Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami —Dade County RER—Product Control Section to be used in Miami —Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product Control Section (In Miami —Dade County) and/ or the AHJ (in areas other than Miami —Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "La Porte" 8'-0" Outswing Glazed Aluminum French Doors — L.M.I. APPROVAL DOCUMENT: Drawing No. FD 2003 Rev G, titled "La Porte —Impact French Out —Swing Door", sheets 01 through 06 of 06, prepared by the manufacturer, dated 12/12/02 and last revised on Nov 21, 2017, signed and sealed by Thomas J. Sotos, P. E., bearing the Miami —Dade County Product Control Section Renewal stamp with the Notice of Acceptance number and Expiration date by the Miami Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitations: 1. See Design Pressure (DP) charts VS door sizes and glazing in sheet 2. See lock option VS DP in sheet 3. 2. See glazing details in sheet 5. For the glazing detail #2 (The 1/8 temp lite is oriented at exterior side in insulated laminated glass make-up). 3. Applicable door egress requirement to be reviewed by Building official LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official: This NOA renews NOA #17-1212.09 and consists of this page 1 and evidence pages E-1, E-2, E-3 and E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P. E. MIAMI-DADE COUNTY NOA No. 18-0503.06 Expiration Date: June 05, 2023 Approval Date: June 07, 2018 Page 1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SU13 IITTED 1. Evidence submitted in previous files 1. Manufacturer's die drawings and sections. (Submitted under previous NOA No.11-0202.03) 2. Drawing No. FD-2003, titled "La Porte —Impact French Out —Swing Door", sheets 01 through 06 of 06, prepared by the manufacturer, dated 12/12/02 with the latest revision "G", dated 04/15/15, signed and sealed by Thomas J. Sotos, P. E. B. TESTS 1. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-11-3201, issued on 01/06/2011, signed and sealed by Candido F. Font, P. E. (Submitted under NOA No.11-0202.03) 2. Test reports on: 1) Uniform Static Air Pressure Test, per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-09 2623, HETI-09 2645, HETI-09-2624 and HETI-09-2646, issued on 10/22/2009, signed and sealed by Candido F. Font, P. E. (Submitted under NOA No.10-0128.04) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202-94 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s HETI-04-1897, HETI-04-1896 A, BETI44-1896 B and HETI-04-1377, issued on 03/08/04 and 03/12/04, all signed and sealed by Rafael E. Droz—Seda, P. E. (Submitted under NOA No. 04 0607. 04) 4. Test reports on: 1) Tensile Test, per FBC, ASTM E-8 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-02—TO95 and HETI-02—T090, issued on 01/13/03, both signed and sealed by Rafael E. Droz—Seda, P. E. (Submitted under NOA No. 03-0219.01) Is aq I. Chanda, P. E. Product Control Examiner NOA No. 18-0503.06 Expiration Date: June 05, 2023 Approval Date: June 07, 2018 E-1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s HETI-02-1253, HETI42-1726, HETI42-1728, HETI-02-1736, HETI42-1742, HETI-02- 1763 and HETI42-1765, issued on 01/14/2003, all signed and sealed by Rafael E. Droz— Seda, P. E. (Submitted under NOA No. 03-0219.01) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC, prepared by the manufacturer, dated 12/12/02 with the latest revised dated 07/02/10, signed and sealed by Thomas J. Sotos, P. E. (Submitted under NOA No.10-0128.04) 2. Glazing complies with ASTM E1300-98/ 04 D. QUALITY ASSURANCE 1. Miami —Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. for their "Kuraray PVB Glass Interlayer", expiring on 12/11/16. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "Kuraray SentryGlas® Interlayer", expiring on 01/14/17. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company (MA) for their "Saflex CP — Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 12/11/18. F. STATEMENTS 1. Statement letter of conformance to, no financial interest and compliance with the FBC 5th Edition (2014), dated 09/02/14, signed and sealed by Thomas J. Sotos, P. E. 2. Statement letter of conformance, no financial interest and compliance with the FBC- 2010 and AAMA 101/ I.S.2-97, dated 01/25/12, signed and sealed by Thomas J. Sotos, P. E. (Submitted under previous NOA No. 12-0127.23) Ishaq 11. Chanda, P. E. Product Control Examiner NOA No. 18-0503.06 Expiration Date: June 05, 2023 Approval Date: June 07, 2018 E-2 Lawson Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS (CONTINUED) 2. Proposal issued by Product Control, dated 07/27/10, signed by Ishaq Chanda, P. E. (Submitted under NOA No.11-0202.03) 3. Laboratory compliance letter for Test Report No. HETI-11 3201, issued by Hurricane Engineering & Testing, Inc., dated 01106111, signed and sealed by Candido F. Font, P. E. (Submitted under NOA No.11-0202.03) 4. Proposal issued by Product Control, dated 03/26/09, signed by Renzo Narciso. (Submitted under NOA No.10-0128.04) 5. Laboratory compliance letters for Test Reports No.'s HETI49 2623, HETI49- 2645, HETI49-2624 and HETI-09-2646, issued by Hurricane Engineering & Testing, Inc., dated 10/22/09, signed and sealed by Candido F. Font, P. E. (Submitted under NOA No.10-0128.04) 6. Laboratory compliance letter for Test Reports No.'s HETI-04-1897, HETI44-1896A, HETI-04-1896B, HETI44-1377, HETI-02—T095, HETI-02—T090, HETI-02-1253, HETI-02-1726, HETI42-1728, HETI-02-1736, HETI42-1742, HETI-02-1763 and HETI-02-1765, issued by Hurricane Engineering & Testing, Inc., dated 01/14/03 and 03/08/04, all signed and sealed by Rafael E. Droz—Seda, P. E. (Submitted under previous NOA No. 05-1116.06) G. OTHERS 1. Notice of Acceptance No. 13-0328.11, issued to Lawson Industries, Inc. for their Series "La Porte 8'-0" Outswing Aluminum French Doors — L.M.I.", approved on 06/06/13 and expiring on 06/05/18. 2. New Evidence submitted. A. DRAWINGS 1. Drawing No. FD 2003 Rev G, titled "La Porte —Impact French Out —Swing Door", sheets 01 through 06 of 06, prepared by the manufacturer, dated 12/12/02 and last revised on Nov 21, 2017, signed and sealed by Thomas J. Sotos, P. E. Note: This revision consist of editorial changes of FBC 17 (6t` Edition) code compliance and update of glazing interlayer. B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). Ishaq 1. Chanda, P. E. Product Control Examiner NOA No. 18-0503.06 Expiration Date: June 05, 2023 Approval Date: June 07, 2018 E-3 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc.(Former E.I. DuPont DeNemours) for the "Sentry Glass ® clear & white interlayer", expiring on 07/04/18. 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America., Inc. for their "Trosifol Ultraclear, Clear and Color PVB Glass Interlayers", expiring on 07/08/19. F. STATEMENTS 1. Statement letter of conformance to FBC 2017 (61h Edition) and "No financial interest" dated 11/17/17, prepared by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. G. OTHER 1. This NOA revises # 14-0908.07, expiring 06/05/18. 3. New Evidence submitted. A. DRAWINGS 1. Drawing No. FD 2003 Rev G, titled "La Porte —Impact French Out —Swing Door", sheets 01 through 06 of 06, prepared by the manufacturer, dated 12/12/02 and last revised on Nov 21, 2017, signed and sealed by Thomas J. Sotos, P. E. Note: This revision consist of "No change". B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS (submitted under file 417-1212.09) 1. Statement letter of conformance to FBC 2017 (6th Edition) and "No financial interest" dated 11/17/17, prepared by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. 2. Lab compliance as part of the test report. G. OTHER 1. This NOA renews NOA #17-1212.09, expiring 06/05/23. Ishaq 1. Chanda, P. E. Product Control Examiner NOA No. 18-0503.06 Expiration Date: June 05, 2023 Approval Date: June 07, 2018 E-4 IMPACT FRENCH OUT -SWING DOOR BILL OF MATERIALS ITEM DRW'G # PART Y REQD. DESCRIPTION REMARKS I L-901 LII-098 1 FRAME HEAD 6063-T6 ALUMINUM 2 L-902 LII-097 1 FRAME SILL 6063-T6 ALUMINUM 3 L-903 LII-090 2 FRAME JAMB 6063-T6 ALUMINUM ' 4 L-904 LII-096 2 SI➢ELITE JAMB ADAPTER 6063-T5 ALUMINUM 5 L-906 LII-092 2 x Panel PANEL TOP 6 BOTTOM RAIL 6063-T6 ALUMINUM 6 L-907 LII-091 1 x panel HINGE STILE 6063-TG ALUMINUM 7 L-905 LII-094 1 x pone( ILOCK STILE 6063-T6 ALUMINUM B L-909 1_I1-095 2 x panel TOP 6 BOTTOM RAIL ADAPTER 6063-T5 ALUMINUM 9 L-911 LII-085 AS REWD. 1/4 ROUND ALUM. BEAD - 7/16' 6063-T5 ALUMINUM 10 L-912 LII-087 AS REQ'D 114 ROUND ALUM. BEAD - 3/8' 6063-T5 ALUMINUM H FD-624-2 L-909 2 x panel HINGE LEAF ASSEMBLY 6063-TS ALUMINUM 12 VVS-001 TP 3286 AS REQ'D. Bulb Vinyl Wts'p: Tenn Plastics, Inc, See Material Composltlan at Sheet 6 13 PWS-001■ AS READ. VTS'P. @ TOP/BOTT, RAILS Schlegel FS - .187'w. X .210'h. 14 PWS-002 ■ AS REIM. WTS'P. @ FRAME HEAD 6 JAMB Schlegel PB - 187'w. X .330'h. 15 . L-910 LII-089 2 x panel STRIKER MOUNTING PLATE 6063-T5 ALUMINUM 16. FD-619 FD-619-1 2 x panel STRIKER PLATE 6063-T5 ALUMINUM 17 F➢-631 1_II-086 AS READ, GLAZING ADAPTER 6063-T6 ALUMINUM 18 HC-001 SF-5502 2 x Panel DELTA FLUSH BOLT (@ TOP 6 BOTTOM OF LOCK STILE) 19 FD-621-2 HC-024/025 I SET DOOR LOCK / DEAD BOLT SET KVIKSET - Series 690T COMHO 20 FD-621-2 HC-024/025 1 SET DOOR LOCK / DEAD BOLT SET SCHLAGE - Series FB350 COMBO 21 FD-621-2 HC-024/025 1 SET IDOOR LOCK / DEAD BOLT SET DEFIANT - Series B31 COMBO 22 ■ FS-035 AS REQ'D. Frame Install Screw - Head (See Notes at sheet 4 of 6) 23 ■ FS-035 AS REQ'I1, IFre.e Install. Screw- Janb/Slit (See Notes at sheet 4 of 6) 24 ■ FS-026 8 FRAME ASSEMBLY SCREW Q12 X 3/4' PH. -PHI. 2S ■ FS-012 AS REQ'D. JAMB ADAPTER SCREW 010 X 3/4' P.H.-PHI. 26 FD-634 LU-171 AS REQ'D. 1/4 ROUND ALUM. BEAD - I1/16' 6063-T5 ALUMINUM 27 ■ FS-043 8 GLAZING ADAPT. ATTACH, SCREW 08 X 1 1/4' FH.-PHI. 28 ■ FS-049 2/Panel Double Rnll Assembly Screw 3/8'x2 1/4' Hex Screw 6 Nut 29 ■ ■ AS REQ'D. NEUTRAL CURE SRIC13NE Schnee -Morehead SM-5731 30 ■ ■ AS REQ'D. NEUTRAL CURE SILICONE ➢aw Corning 899 31 ■ + AS REQ'D. NEUTRAL CURE SILICONE Tremco S-500 32 ■ ■ AS REWD, Laminated Glass see Pg. 5 Dupont - Sentry Glass Plus 33 IN ■ AS REWA Lominated Glass see Pg, 5 Dupont - PVB 34 ■ ■ AS REQ'D. Lanlnated Glass see Pg. 5 Saflex - PVB 35 ■ HC-002 ?/Panel PANEL ASS'Y ALUM, PLATE I WEN 2'x 1/8' (6063-TS ALUM.) 36 HC-004 ?/Pane( Panel Ass'y Full Lenght Rod 3/8'111 -20D Rod, Plate, Flange Nut 37 ■ FS-011 8 HINGE ATTACHMENT SCREW Q10 X 3/4' P.H. / PHI. 38 ■ FS-044 12 SIDELITE ATTACHMENT SCREW #10 X V PH/PHI_ - (l7' CC Max) 39 HC-006 2PP0SOBGI 6/Jamb 1/2' Diu. Hole Plug - Nylon 6-6 MICROPLASTICS - Rockwell M-79 40 HC-007 62PP087BGIII 2/Pant 7/8' Ill.. Hole Plug - Nylon 6-6 MICROPLASTICS - Rockwell M-79 41 a HC-MO I 1/BOLT FLUSH BOLT Sill Plug - Nylon 6-6 SUNCOPLASTICS Inc. Rockwell M-79 42 L-913 LII-096 JAS REQ% 1/8 ROUND FALSE ALUM. MUNTIN 6063-T5 ALUMINUM 43 ■ ■ AS REQ'D. INT FALSE APPLIED MUNTIN 125' X .02Z' STOCK ALUMINUM 44 L-915 FD-623 AS REO'A FRAME HEAD SHEAR PLATE 6063-TS ALUMINUM - 4' long 45 L-916 LII-117 AS REQ'11 FRAME LOW SILL - OPTIONAL 6063-TS ALUMINUM 46 1`13-635 HC-050 1 TWO -POINT FLUSHBOLT LOCK OPTIONAL ( FOR */- 76.0 psf DP) 47 FD-626 FD-626-1 2/Panel FLUSH BOLT GUIDE ALUM. ANGLE 1 1/2'x 1 1/2'x 1/8' At.. 6063-T5 4B 1`11-627 FD-627-1 2/Panel 2-Point Lock Bolt Guide ANGLE 3'x 3'x 1 WEN 1/B' Alun. 6063-T5 49 ■ ■ AS REQ'D. Joint Sealant- White Colored 'Purvis Ca' Super Seal 50 F➢-638 HC- 1 SET LOCK ACTIVE HANDLE 6 TRIMSET ASHLAND aV5201A-A 51 F➢-637 HC- 1 SET MULTI -POINT LOCK ACTIVE ASHLAND QWSIIG-STACTS 52 FD,640 HC- I SET LOCK PASSIVE HANDLE 6 TRIMSET ASHLAND QV5201A-P 53 FD-639 HC- I SET MULTI -POINT LOCK PASSIVE ASHLAND RW5110-STPAS4 54 F➢-641 HC- 2 x panel Multi -Point Lock Holt Guide NYLON 6-6 Rockwell H scale 79 55 ■ FS- 4/Guide Bolt Guide Attachment Fastener 06 x 1/2' P.H/PHIL. 56 FD-642 HC- I K Lock Lock Top Mount Adopter NYLON ADAPTER 57 FD-643 HC- 1 x Lode Lock Batton Mount Adapter INYLON ADAPTER AW)DUCi A&4&w4b s=<oup(yiep with The„ BniaU g Gede At, .N-OS I:aptraties 9s9--n-3 ay_�s 4?I■a iads R'"bill 14� 1/2' Hex Unit Width Sidelite Berme anchor spacing Swing Panel Width as 9M Panel Vldth Al ( 33 13/16' rax.) (35 3/16' rnax. ) 5" Rs R' lap hing p IB SEE O 3 ALTERNATE BOLT DNS AT SHEET f 6 / \ 25' Max. DLO Width J .J. N J / \ f'Q +'N a = Active Inactive m a = L. d ti d3O =a' \2 'gyp S y y X t IB 20 21 6 1/2' m q \ o s a a f� v Sidelite dead -bolt >i f N Q V U 4 \ v a lack se6' 5 Side —� ngDt1BL RAIL❑� B 2 3 / HATE BOLT ite O ON AT 6HEEf (" 1 3 bottom 8' a75 5 3/4 6'6' 6' 6' ANCHOR NOTES: 1. SEE ELEVATION AT S ANCHOR O.C. MAX. SPACING AND LOCATIONS. 2. SEE SHEET 4 OF 6 FOR INSTALLATION FASTENERS TYPES. 3. SAME ANCHOR SPACING ® FRAME HEAD & SILL SHEET .1 QUALIFIES SFAGLE & MULTIPLE PANELS (SEE ELEVATIONS). QUALIFIES UNITS WITH AND WITHOUT SIDELITES MAX FRAME SIZE 145 1/2"w. X 95 3/4"h. OXXO EXT & INT FALSE COLONIAL MUNTIN APPLIED W/SHdCONE. QUALIFIES SINGLE OR DOUBLE BOTTOM RABS MAX DAICLITE OPENING WIDTH = 25" MAX. DAYLITE OPENING HEIGHT = B3 1/8" SEE ELEVATION AT SHRET 1026 FOR MAX ANCHOR SPACING ALL DIMENSIONS SPECIFIED ARE IN INCHES NO HURRICANE SHUTTERS ARE REQUIRED ►AOC11C C REVI6P9 ss mapyla� wily the Fk r ils &aWlny as& Fapl4tl■a Date('^/'ZrrjNeo THOMAS L. SOTOS PROFESSIONAL ENGINEER y�,�r Hy y. y,F C.Qhw FL LIC. 4' 55225 SI. o A9d, Revision Notes: Revised to comply w/ FBC2007 & ad • �G •�S�• �Osya�s Insulated class 01/22/10 Ashland Mult-Paint lock 01/27/11 Revised 4. comply w/ 2010 FBC 9 Revised to comply w/ 2014 FBC it Revised to comply w/ 2017 FBC A E Of : Nelson Erazo nab / 1h, Nelson Erazo °p1/20/ °� �3vI ..e1...L 1 5' •7 __F o.c''FWe po.rie Inac Iva pnneU LpLOg; Same anchor spacing "OXXO" EXTERIOR ELEVATION t frame head & sit, NOTES: 1). THIS PRODUCT IS DESIGNED AS PER FLORIDA BUILDING CODE (2014-Sth EDITION & 2017 - 6th EDITION). 2). GLASS MEETS REQUIREMENTS OF ASTM-E1300 AS PER CHAPTER 24 OF FBC CODE. 3). 1X OR 2x WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOAD TO THE STRUCTURE & TO BE REVIEWED 13Y BUILDING OFFICIAL. 4). ANCHORS SHALL BE AS LISTED. AND SPACED AS NOTED ABOVE AND ON DRAWING DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 5). SEE NOTES ® SHEET 4 OF 6 FOR INTALLATION FASTENERS TYPE. 6). ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL ' LIMITATIONS• 1). MAX. DP = ±86 PSF W/ (4) Surface Bolts & Glass Types A B. C & D. (SEE LOCATION DETAILS 0 SHEET 3 OF 6) 2). MAX. DP = ±76 PSF W/ 2-Point Lock (active)+ (2) Surface Bolts at Inactive 3). MAX. DP = t76 PSF W/ not Sill & must be used where water infiltration is not required or opening is protected by overhang ratio greater than one. 4). MAX. DP = t86 PSF W/ Multi -Point Lock (1-active)+(1-passive) at Inactive dad L /IN S O �,/ MEDLEY,8501 WFLORIDAt33166 JJI((LLNJJD1�7L7�LS66TRIES.�L�IN C�9'. (305) 696-8660 M NUFACTURSR OF QUALI7Y ALUYINUY OWDOUS AND CUSS DOORS NOA em.c Part ewe r.w ral.Port„ s..e"./D_._,. — __ NOA APPROVAL IMPACT FRENCH OOaR 1 OF 6 1� "La Porte" Impact" French Out —Swing Door Ir�on6er. '-'- Nwmear. FO-2003 110 7/8' Max U9i Width Svin SEE ALTERNATE 8 Pnngel Vltlih OPTIONS AT SHEEP C 35 3/16" mGx7 3 .1 6, A Nox.12DL0 id* m II D I, II �D_ ll II �% II II m H I mJ 3 X s' F `3 O�NSFATASHE2EIF 0, "OXO" ELEVATION 145 1/2' Max Unit Width SEE ALTERNATE BOLT Sldellte 3P RONNS AT SHEET $wing Pnnel Width Pnnel Vltlth C 33 13/]6' ( 35 3/16' max, 7 (A L II _ II 25 Max. 111. 0 Width , mom° xA =m � GII II DII /%i% II EII \ II I D II �_ d E a x a co II II II II Active IN ctive I k II o I mA Li 117 H IE- SEE ALTERNATE BOLT -"- OPTIONS AT SHEET 3ot 6 "OXXO" ELEVATION ANCHOR NOTES: 1. SEE ELEVATION AT SHEET 1 OF 6 FOR ANCHOR O.C. MAX, SPACING AND LOCATIONS. 2. FAEE SHEET ,4nP0ES F.B FOR INSTALLATION - 74 I/2/ Mox Unit Width Sldelita "OX" ELEVATION APPROVED CONFIGURATIONS NOTES: 1. ALL ELEVATIONS ARE A GRAPHICAL REPRESENTATION VIEWED FROM THE EXTERIOR SIDE. 2. FALSE COLONIAL MUNTINS ARE APPLIED W/ SILICONE AND ARE AVAILABLE AS OPTIONAL. 3. PANELS ARE AVAILABLE WR OR DOUBLE BOTTOM RAILS.H SINGLE BOTTOM RAIL 4. OUT -SWING DOOR WITHOUT` INSECT SCREEN. © PRODUCT d8M✓ w4b t4 eomplylnQ wFt6 i!s}Ielei BDldtag Gode Aaeptsoce No 18-OSD3. o6 El I.��� I Via°' k*%fttkNWW A. No - 212.0`S ❑p��JJppLL'RA'Q �Osptaeer OoteCJ 19,` iM iTO THOMAS J. SOTOS PROFESSIONAL ENGINEER FL IX.s$ 55225 SLINt Width III ER SUN*/width i/ 3 .106 ATr LT 3 T e 7-1 o e� x = a+ G s°o w Q ig 8mm Fixed iji% �t II E \ 1 '30PRd0 S ATASiiffTLT `OR ONS ATSHEE�f LT 3of 6 "X" ELEVATION "0" ELEVATION "LaPorte" IMPACT FRENCH OUTSWING DOOR - DESIGN LOAD CHART PANEL 11H)TH/BBtGHT A (�IlV�S� NOHBER OF OCRO6S /1� DP GLA93 TYPE "A" k "E" +/-(PSF) PANEL W1DTE TUAL �IN�S� DP ( PSF ) GLASS TYPE •H" +/-(PST) GLASS TYPE 'C• +/-(PST) GLASS TYPE •D• +/-(PSF) NIDTH • HEIGHT • •ID1H . 10 1/4' 16 1/4' 22 1/4' 28 1/4' 30 I/4' 34 1/4' 77' �i5) S ±86.0 II 3/16' ±76.0 +76,0 ±76.0 5 +86.0 17 3/16' ±76.0 ±76.0 ±76.0 5 +86,0 23 3/16' ±76.0 ±76.0 ±76.0 5 ±86.0 29 3/16' +76.0 _+76.0 +76.0 S 286A 31 3/16' t76.0 t76.0 t76.0 5 +86,0 35 3/16' +76,0 +76.0 +76,0 101/4' 16 1/4' 22 1/4' 28 1/4' 30 1/4' 34 1/4' 1 93' •(6) 6 +66.0 It 3/16' +76.0 +76.0 ±76.0 6 +86.0 17 3/16' ±76.0 ±76.0 +76.0 6 +86.0 23 3/16' +76.0 +76D +76.0 6 ±86.0 29 3/16' ±76D ±76.0 ±76.0 6 +86.0 31 3/16' ±76.0 +76.0 ±76.0 35 3/16' +76.0 ±76,0 • 0 PARENTHESIS INDICATES j OF ANCHORS AT FRAME lB�n ouiwmu wue. fib. °'vse Revlsed to oomply w/ FBC2007 &added �� ® 8501 NW 90th St. i F•gtii Insulated Glees o1/2 /10 �L// (((CCP MEDLEY, fLORIOA 33166 •. "r e Ashland Mult-Point Lock 01/27/11 Revised to comply w/ 2010 FBC INI7 T-T IES INC. (305) 696-8660 m Revised to comply w/ 2014 FBC MANfFACTURRR OF QUALITY ALUAUNUY WLNDOWS AND CLASS DOORS Drmu c: .M= Revised to comply w/ 2017 PHC vet c+w.: r.m c utw".Y: s.r LL. rt.,rc SA.rt NOA APPROVAL INPACT FRENCH DOOR 2 OF e OF � "` ' Nelson Erato '11/01Aj19 "La Porte" Impact" French Out -Swing Door �:Y � �� Nelson Erato AWmpm IDnsulro 1nm,a.r - FD-2003 TAPCON W/ MIN EMBED. CITES BELOW FOR SPACING) 2 x (P,T,l WOOD BUCK _-1/4' MAX. SHIM TYP, MULLION Sldetlte 1 1/4' MIN EDGE DI- TYP DL❑ Wlath 14 Panel Width 1 }' MIN EMBED. O O TYP 18 46 Active INTERIOR SIDE UTh700R SIDE Inactive Active Inoct(ve 0 18 / EXTERIOR SIDE J ER mOR SIDS LOCK STaES WITH FLUSH BOLT LOCK STILES WITH TWO —POINT LOCK & FLUSH BOLT INTERIOR SIDE EXTERIOR SIDE 22 tl Slit SILL �,, Helght �•.� "+4 � 1 6' MIN EMBED. INTO • '•�' 3500 PSI CONIC, (TYP.) 1 1/4' 1 /16- LCOEMBEDTAPCON W/ IN (MIN. EDGE GIST.) (SEE SHEET• I OF 6 FOR LOCATION AND SPACING) B2 OPTIONAL — DOUBLE BOTTOM RA! DETAIL PRODUCI It "W40 sa toaPlylaswNh IhelNA�e DaidAg Cde Acceptance Na 1 a153•o6 tspf.06M. Ow 'y ��- MnAdiill! INTERIOR SIDE LOCK STILE Active L'J 1 I /_ 1 V,) Inactive 1 x (P.T.) WOOD BUCK - (SEE NOTE 3, SHEET 1) 4 3 MULLION o JAMB 12 I Sld17ellte Q 12 38 OEXTERIOR SIDE O uox}i0^ UNIT WIDTH 1/4' C2 MAX S -5/16' TAPCON W/ 1 1/e, MIN EMBED. SEE ELEVATION AT SHEET 1 OF 6 FOR SPACING •=• MI un Edge Distance ANCHOR NOTFS: 1. SEE ELEVATION AT SHEET 1 OF 6 FOR Ie F 10 ANCHOR O.C. MAX. SPACING AND LOCATIONS. ale 2- SEE SHEET 4 OF 6 FOR INSTALLATION FASTENERS TYPES. kt0VDCrQrlvl oadp aawit4 Ift61lot"L.' 2 G3 3 Active OPTIONAL BOLT Inactive 0 TOP RAM °�C'd° ptaere No �/?12• 5 �re'J�. 17 D 1 � 1. -� OR SIDE DrfER[aR 9IDE 6' L Active Inactive nar( 5 -Point 0 13 45 OPTIONAL SILL Helghtl .(,'�.�I"•Ie �`�l �'yMIN EMBED, INTO 18 I ' 3500 PSI CONC. (TYP.) OPTIONAL BOLT ® BOTTOM RAIL. 1 1/4' 11/e' MINEMBED.N W/ ( SEE DETAIL E3 FOR MOUNTING LOCATION) (MIN. EDGE DIST.) TWO —POINT WMTI—POINT FLUSH BOLT & • FLAT s 23 MAX. DP - *76 PSF MAX. DP = t86 PSF TWO -POINT LOCK LWTATIONS: DOORS 4 SIDELITES WITH THIS SILL TO BE 95 1/4' MAX, FRAME HEIGHT. OPTIONAL LOCK DETAILS 1). MAX. DP - t86 PSF W/ (4) Surface Bolts & Glass Types A, S, & C. THIS TYPE OF SILL IS LIMITED TO +/- 76.0 psF DESIGN LOAD AND MUST BE USED WHERE WATER INFILTRATION IS NOT REQUIRED OR THE TROMAS I. SO OS 2)• MAX. DP = t76 PSF VI/ 2-Point EXTERIOR OPENING IS PROTECTED WITH AN EXTENDED CEILING OR ROOF PROFES$I GNEBR Lock (active)+(2) Surface Bolts 0 Inactive OVERHANG GREATER THAN OR EQUAL TO THE HE OF THE WALL WHERE THE'DOOR IS LOCATED. �aZ ';s• g��:g•.,• p °o � . -Q(j1 °>+ RevisionNotes: Reviseddto comply w/ FBC2007 &added 4VgV/OWllt//. 8501 NW 90th St �� S ON 66Z2lated 5 laeu Glass 01/21/10 F W MEDLEY, FLORIDA 33166 Aahlead Mnli-Point LoeJc 01/27/11 INDUSTRIES, INC- (305) 696-8560 fir= Revised to comply w/ 2010 FBC to MANUFACIM?RR OF QUALITY ALUMINUM ILNDOTS AND CLdSS DOORS T� �� �+ Revised comply w/ 2014 PRO Revised to w/ 2017 FBC er nv n__. , c1.e; nva cn wv: s.rw w NaA APPflOVAL IMPACT FRENCH DOOR 3 OF 6 CH DOOR 'nii%o1%17 Nelson Braza "LaPorte" Impact" French Out —Swing Door ,��n'PA /^•,1,_ �` �e Nelson Br 01/ 0 12 DATE �_ _ ..to. aan�• Nr.ne.. �'NA FD-2003 Rru4(on L.vtr G 5/16' TAPCON V/ SEE BELOW FOR SPACING INTERIOR SIDE I x (P.TJ WOOD BUCK 1 z (P.T.) VODD BUCK (SEE NOTE 3, SHEET 1) (SEE NOTE 3, SHEET 1)3 �!. 3 + 3 AMB 19 20 21 JAMB :,•� INTERIOR SIDE 3 LOCK STILE `e' p _ LOCK STILE 9 t• 1 �^ 19 20 21 JAMB ' r I 46 29 30 31 6 23 ems' " ;v",.•�=. 46 6 7 9 30 31 Active 36 7 Inactive •'Y' 23 Active F I � 27 17 18 9 10 37 - TYP. ";; •r :' :. 37 9 10 O12 E' 627 1 1/Y O MAY SHIM O O (MIN. EMBEOJ � ,,,, 1EMBED UN WIDTH MIN UNIT WlD1.. EXTERIOR SIDE (TYP.) wz EXTERIOR SIDE —m¢ TYP.' •,:,�` ,.••tt .•. .. , 5/16' TAP... V/ 1 1/2' MIN EMBED. Z SEE NOTES FOR SPACING) 11/4' KIN. EDGE DIST TYP 5/16' TAPCON V/ 11/2' MIN EMBED. SEE NOTES FOR SPACING 19 LOCK STILE 3 20 21 4 MULLION INTERIOR m= U7pp! A SIDE ra; �• 'g 2x P.T WD. BUCK (SEE 1 1/2• MIN. `�• , `' =' 1 x (P.TJ WOOD BUCK 29 30 31 7 46 38 ` NM EMBED TYP 3;,�-� i' 's��g:< NOTE 3 AT SHEET S) ; E17BE0. .. TYP , `•eK +_, - (SEE NO7E 3, SHEET 1) 12 6 •r.• —�,,�71F, --TE Active Sidellte 1 v." MAX. 1 1/q• NpX SHIM TYP. HEAD 4,7 SHIM TYP. HEAD 44 13 A 22 ,t ( 13 22 9 10 12 8 12 A l 8 T E%1EK[OR SIDE 14 SIds'H38 5 AttacSidstithment Screw Acrews H O 5' ( 6 Screws @each 0 e side of jambs, 27 16 - 12 total per sldellte > ' INTERIOR SIDE 9 30 31 50 51 INTERIOR SIDE 52 53 _ 9 10 LAM AT GLASS LO w 3 33 34 s 10 P4 0KC1 116Nt'CFlt/ LOCK STILE w w F- x = _ =EXTERIOR SIDE (� as Mown wRr on l4Af 8016heCod, 56 57 _ w 43 z w 43 Acceptaove No 1 0fd3GG Active 7 7 .~. Z = 42 ¢a = 4 Eaplra/ioa DaLt - 3 Inactive as o INTERIOR SIDE q I 11 By 1,�� l •��ytia�..�� n• lax nc 7111am1 Di16'6'111A1(�lpv 17 � EXTERIOR SIDE _t 17 5 iB 5 EXTERIOR SIDE 13 2 12 13 2 12 THOMAS J. SOTOS PROFESSIONAL ENGINEER FL LIC..1#. s12.26 O23 B 1 23 -L SIU !"��' Hel ht 9 { Sill 'Height SILL SILL 'I • • • '' +• ~-A (MIN. EDGE DIST.) '; MIN EMBED ~ ^' '.i.I k',MIN EMBED. INTO TYP t', ~•� •+�' 3500 PSI CONC. 5/16' ELCO TAPCON •V/ +• (TYP.) 1 1/2' MIN EMBED. 1 1/4• CSEE SHEET 1 OF 6 FOR SPACING) (MIN. EDGE DIST.) — 5/16' TAPCON W/ 1 1/2' MIN EMBED, SEE ELEVATION AT SHEET 1 OF 6 FOR SPACING INTERIOR SIDE LOCK STILE 3 ,. 19 20 27 Active i r I ' (EDGE OIST.) TYP, ` )J5- 12 (NIR EMBFD•) L G2 2 TYP. _ EXTERIOR SIDE 50 51 Q INTERIOR SIDE I Active I EXTERIOR SIDE G3 3 INSTALLATION FASTENERS NOTES: '1X BUCK' MINIMUM REQUIRED FASTENER LENGTH HEAD: 5/16" X 3 1/2" Long TAPCON(-) JAMB: 5/16' X 2 3/4" Long TAPCON(-) MULLIONS: 5/16" X 2 1/4" Long TAPCON(-) 0) TAPCON BY 'ELCO rt e ON" "2X BUCK' MINIMUM REQUIRED FASTENER LENGTH HEAD: 5/16" X 3" Long TAPCON (•) JAMB: 5/16" X 2 1/4 Long TAPCON(-) MULLIONS: 5/16' X 2 1/4" Long TAPCON(') 0I TAPCON BY 'ELCO LO.TRACON" AT SILL' 5/16' TAPCON w/ 1 1/2' MIN EMBED. INTO 3500 PSI GONG MIN. NOTE: ALL FASTENERS W/ 1 1/2' MIN EMBEDMENT 1 1/4' MIN. EDGE DICTANG & 1 /4` M v HIM SPp ANCHOR YIELD STRENGTH Fy-155ksi ANCHOR ULTIMATE STRENGTH Fu=177ksi • ALL TAPCON LENGTHS "L' SPECIFIED ARE MINIMUMS ( SEE ELEVATION AT SHEET 1 of 6 FOR ANCHOR MAX SPACING AND LOCATIONS ) • 1 ' SO •,d' T e�. Revision Notes: Revised to comply w/ FBC2007 k added ` go 9� 8501 NW 90th St. ON iF•.,0 -'j Insulated Glass 01 22 l0 / / 1L/ltlllll IOFp//7Dq// MEDLEY, FLORIDA 33166 •. `s Ashland Mvlt-Poin! Lock 01/27/11 INDUSTRIES, INC_ (305) 696-8660 .Y e Revised to comply w/ 2010 FBC Revised to comply w/ 2014 FBC MANUFACTURER OF QfIALTTY lLWfDJOY II7NDOI13 IKD CLASS DOORS L.u,e Ca r. rns a— Fred CaY NOA APPROVAL v"u s.•(. /Mnd e — sr,..a IMPACT FRENCH DOOR 4 OF 6 1 I: Revised to com 1 w 2017 FRO P 9 / +u0 s.w.a er: Nelson Eraz. n°1 /01/1 11 01/17 "La Porte" Impact" French Out —Swing Door D Al2 Nelson Erazo 01D20 mt.s. AV— R�sA.,: s.�es R.m,Dvr. FD-2003 R.v(.a. r...E G - -'-.• SmELITE ATTACHMENT uWBLE GROVE U' 1/4 SCREVS /R2 AID x 1' RL/PMIL ASSERBLr SOa:VS /2e .. ..� EALED U .12 x 3/4' PM/PRD. J— VFAT ERSTRIP FACE UP -- I 3. 1e 16 Sul ADAPTER- -•--.•..__ D1TOUmR SIDE' FRAME ASSEMBLY DETAIL SIDELITE/JAMB ATTACB1 \CRAARSIDE) ACCESS 51mVN SDd, SEALANT DETAIL (ATE HEADER TO BE SEALED SDULAR TO SILL I/�%„/ I LEFT DOOR VILE DEP1 83TIM LEFT JAMB INTER THRET B/e• HDJGE ATTACI.CNT/ II SCRLyS /3l U RID x 3/1' PH/PHIL IINGE ATTACHMENT )ETAI S AC�SS x aE % / LEFT K14D HNGE LEAF TD DmR W STILE XMIJ. RACHMENT ME% NUT am AIID VASHE '4' PM/PIDL. PANEL ASSEMBLY DETAIL N14 SMS OR SELF DRILLING SCREWS INTO METAL STRUCTURE (SEE NOTES FOR SPACING) I. --J� -O.125 THK. MIN, -{MIN EDGE DIST. (6063-TS MIN) I ALUMINUM TIME MULLION IN' �- - REFER TO APPROVED MIA14I-DADE NOA 1/4' MAX, SHIM TYP. ACCESS MULE COVER 414 SMS OR SELF DRILLING SCREWS INID METAL STRUCTURE ' (SEE NOTES FOR SPACING) --II----12 GA. MIN, DIST, (fy c 36 KSI MIN" �tEJDIE STEEL TUBEOR CDLUITO BE IN CONTACT HH TO BE PLATED DR PA', 1/4' MAX. SHIM TYP, 1 1/4, MIN. 5/16' ELCO TAPCON W/ EDGE1 1/4' MIN EDGE DIST. 5/16' TAPCON W/ I TYP r"'TYP� 1 1/2, MIN EMBED, INTO CONC. 1 1/2' MIN EMBED, (SEE NOTES FOR SPACING) (SEE NOTES FOR SPACING) (CONG TO BE 3 KSI MIN,) •l?.', 2 x (".T.) 11/2 I f/2' WOOD BUCK (SEE GEN. NOTE 03) (MIN ED) • (MIN, EMBED 1/4' MAX. SHIM TYP. L�=11-. NOTE 13PTENAL INSTALLATION DETAILS MAY APPLY TD DOOR FRAME JAMB AND/OR FRAME NEAR FRAME INSTALLATION OPTIONAL (TYP.) SHIM TYP. DETAILS INTERIOR SIDE 17 Glazing Adapter Depth Laminated Glass Typ 1 'tA B" or 'C" by : (see below) a (SEE TABLE V/ CORRESPONDING DETAIL GLAZING TYPE 6 ➢ESCRIPTIOW 1/4 Round 3 33 34 Head g 10 EXTERIOR SIDE GLAZING DETAIL #1 'A' - SENTRYGLASS by- Kuraray America, Inc, 'B' - TROSIFOL PVB by, Kuraray Americo, Inc. 'C' - SAFLEX PVB byi Eastman Chemical Co. INTERIOR SIDE 10 Glazing Adapter*G1&i�ggbBea@d 5/16" Iaminated GlassTypes "D" or "E" 33 34 by(see below) SEE TABLE V/ CORRESPIrBUNGiLAZING TYPE 6 DESCRIPTION)1/4' InsulatedAir Space w/1/8' Temp.Glass INSULATED SPACER 'T_Seal'- Dura Seal S'-Vte Spacer 2G Black - I/4' AI_ SpnCe Pt,Na, 812-25H-357 . EXTERIOR GLAZING DETAIL #2 'D' - SAFLEX PVB byl Eastman Chemical Cc, 'E' - SENTRYGLASS bye Kuraray America, Inc. xIN[S Nam o+3 vLUG— < xa L-IDi2 I v16•I£rn�ns srcn va .PROD1JL1fWMgW44 " a. taasKylapwith *etude d.ldi.g CWC A(eepta.c. ND I D eG LxVinO�n 0-_.A s s ".ram VIIr : ).o� to l¢ o23�i GLAZING TYPE & DESCRIPTIONS .466' O A Laminated Glass bV Dugout - Glass Type "A' rr9m DESCBn'1'SON 1_ DEW 32 1 3/16' Amealed 3/ 6• 400• _ 3 ass• 2 ,090- SentryGlass Interloyer 3 3/16' Annealed .340' 0 A Laminated Glass by Dupont - Class a "B" 1TEY ➢ESORIPTTON ➢ETAn, 99 1/8' Annenletl o9r I j us4r 2 TROSIFOL PVB Interlayer 3 1/8' Annealed .340" 0 A Laminated Glass M Solutia - Glass Type C' rrKH DEScHwnoN II � Brun, 94 1 , uS4C 1 1/8' Heat -Strengthened Gl oss 2 .09V Saflex PVD Irty A yer 3 1/8' Heat -Strengthened Glass GLAZING TYPE & DESCRIPTIONS .340 0 A Laminated Glass by So lu 'a - Glass Type "D rrElt DBSCIUMON nSDAn. 1 I/6' Heat -Strengthened Glass o A. 2 3 .09V Saftex PVB Interlayer 1/8' Heat -Strengthened Glass 4 1/4' INSULATED AIR SPACE 5 1/8' TEMPERED GLASS .340 O A Laminated Glass by Solutia - Glass e E rMd ➢ESCRO-noN BErAn. 1 I/8' Heat -Strengthened Gloss 2 3 .090, SentryGlass InteNayer 1/8' Heat -Strengthened GlassI�B��7CIB- I ' DOW 4 1/4' INSULATED AIR SPACE 5 1/8' TEMPERED GLASS PRODDCf REVMM .�iwitiedw FisAfe ode AaapMace Ne 1 P•P�letiaa BUG G JIG � ee Q PT➢dLiOt to rHOMAS J. SOTOS HINGE ASSEMBLY DETAIL PESSION ENGHIERR 11 #FD-624-2 FL TJC. 55225 C;•'' 904A e: + .'GP i°si Revision Notes: to comply FBC2007 &added RevisedInsulated �,r n v,a r� G///9gN// 8501 NW 90th St. 1: ' ,SF• OS ��' 2/ Inedated Clara 01/22/10 �/gL@'J.LLnlIl1101. VIVpI MEDLEY, FLORIDA 33166 Aahl.nd Melt -point Lock 01/27/11 NDUSTF2IES, INC. (305) 696-8660 O •; * Revised to comply w/ 2010 FBC IFANIVACfURER OF QUALITY ALLWNUAf NZNDOWS AND CLASS DOORS a _ Revised to comply w/ 2014 FBC Dww e(oAc ra•e eTa.r. Asa eee. DaCiv sFIENCH e c — sAe•a Revised to comply w 2017 FRC P y / MCA APPROVAL IMPACT FRENCH DOOR 5 of 6 eJ T ave Nelson Er azo Di /011/17 "LaPorte" Impact" French Out —Swing Door •��� D Nelson Erazo 01/20/12 CIO �•iAl �a°°`~ D~"ate a.ww L.wr -ea16/e n.te. FD-2003 G t/s• GO, ;TEEL BOLT IE 56 B 1 S/2 FLUSH BOLT AND OTWO -POINT LOCK 49 ANGLE GUIDE #FD-627-1 57 ? 3/8' D,D. STEEL BOLT STEEL BOL7 Optional Multi -Point Locks OPTIONAL 48 TWO -POINT LOCK (+/- 66.0 PSI DP) Active Lock Poss1ve Lock LOCK #HC-060 ASHLAND OW5110-STACT5 ASMLAND OW5110-STPA1 76.0 psi DP) cHANDLE"8 TRDdSET -HANDLE 6 TRIMSET 1. 500 L124 1.500 INACTIVE -PANEL FLUSH BOLT 47 ANGLE GUIDE 1 1/2" LONG #FD-625-1 2' 1 1/2' If SIDELITE PANEL ALUMINUM PLATE 35 2" LONG #HC-002 r� � { _1 STAINLESS STEEL BOLT N) Od 9/16' ab. SSS C./- 76.0 psf) b) 3/e• O.D. SSS (./- SU psf) INACTIVE -PANEL 18 FLUSH BOLT #HC-001 .076 -{f- .875 (.062 1.259 I GLAZING ADAPTER #L-930 119 .7 _IF 2.031 ---{ 11 HINGE LEAF #L-908 0.656 1.250 { .045 HALF ROUND 42 FALSE MUNTIN #L-913 --{I-'07 050 I I .460 986 L .9D6 r QUARTER ROUND 26 (11/16') BEAD #FD-634 0601 .726 f^i- .808 QUARTER ROUND 10 (3/8') BEAD #L-912 1 r.076 060 i 835 .656 1 1 .808 -}- OQUARTER ROUND (1/4-) DEAD #L-911 O8 Ial ADAPTER #L-909 Flexible Vtn FPVC Cote oedion-Team plastics Inc. •1. FPJC Black Comoouod No, 7200-75 PHYSICAL ASDM NO. D-ays,"Hardass'A",10- 75 D-27A0 SpariSe Gravity 1.45 D-792 Temik Strenglh,PS[ 1640 D638 Ultimate Fimption % 340.0 D638 Modulus@ 100°/, 9m8a6co PS[ 765.D D638 Impactl3dta.ess 31.0 D-746 -2. FPVC White: Compound No. 7267-75 PHYSICAL ASIMNO. Duometerlfardass"A",10sec 75 D-U40 Specific Gravity 1.45 D-792 Thm0o Slr1APSI 1640 D-08 p U.. Bloagdio4 % 325.0 D638 ax Modulus (�lOD%Flmga6m, PST 765.0 63 D8 1m actBritI.- -30.0 D-746 i-� 3.5 -{ .096 1.750 074 .127 OPANEL HINGE STILE #L-907 �I 4.187 .098 1.750 .075 F, 5.05 { OPANEL LOCK STILE #L-905 I-- 4.500 1. I50 687 ,065 f 11 O FRAME HEAD 1.812 #L -901 1.250 1 .1007,064 �- 4,500 OFRAME SILL #L-902 1.75 -I L750 -I 125 .072 J .065 4.000 LW.O500 i - .100 L612 PANEL TOP & O BOTTOM RAIL #L-906 O FRAME JAMB #L-903 NOTE" I. ALL DIMENSIONS SPECIFIED ARE IN INCHES 2.�ASEE CgELEVATION AT SHEBT 1 OF O FOR uL4 ff0,pJ,MAX. SPACING AND LOCATIONS eap[ylas with 4W nNift as FROnDCTREvISEq idly[ Code ft as Rwilk the M7c+C;le EaphaRoa Base AOW°Qee No 17-/2J2.09 THGRAS J. SOTOS 1 fibe Bole G PROFESSIONAL ENGINERR 4; `51...., `. liw.,,l,� IG4 PL LIC.4 5u225 i6wal tN1 6 a-� -1- to eemPIY A/ 1PBC2007 & added dehlend Mult-Point look 01/27/11 a Revised to comply n/ 2010 PBC Revised to comply w/ 2014 FBC jr m Revised to comply w/ 2017 FRC OF L=' Ito a dOa Nelson Erazo non ON 11/0 Neleon'EYazo Om/-1, r 1.812 -I 066 F -063 21� 4.500 -1 OJAMB ADAPTER #L-904 4.348 -{ I. { 0.o7e Q058 J 4.066 44 FRAME HEAD SHEAR PLATE #L-915 �2.688 .218 100 .500 II----4.5001 45 FRAME LOW SILL #L-916 (-11 NOTE: REFER TO DETAIL '33' AT SHEET p 3 OF 6 FOR ADDITIONAL NOTES AND LIMITATIONS. LA V S ON8501 NW 90th St. MEDLEY, FLORIDA 33166 INDUSTRI S, INC. (305) 696-8660 MOMFACTURRB OF QULUTY ALU"UN SJSDOWS AND CLASS DOQRS wo Qan: Part CTau: Rod Cvf{my; 9wU./Afed�L• - SM.e OA APPROVAL IMPACT FRENCH DOOR 6 OF 6 "LaPorte" Impact" French Out -Swing Door N%eT' FD-2003 IR'a4"_ n L-